| Sl No | Description | Qty | Unit | M/S NAASIR ENGINEERING WORKS L1 | M/S KHAN ENGINEERING WORKS L2 |
|---|---|---|---|---|---|
| 1.00 | Providing/fitting of high-quality insulation tape rolls for day-to-day use at various water supply schemes. | 10 | Nos. | 110 ₹1,100 | 105 ₹1,050 |
| 2.00 | Providing/fitting of Polymeric composite Pin insulators (5KV) as a replacement of damaged ones--- For WSS Chuntwaliwar 2nd | 10 | Nos. | 350 ₹3,500 | 355 ₹3,550 |
| 3.00 | Supply, Installation, Testing and Commissioning of Post type Link set assembly complete in all respects for 11KV Power Supply as a replacement of damaged ones---For WSS Khonmoh Ist and WSS Samander Colony. | 2 | Jobs | 6,000 ₹12,000 | 6,100 ₹12,200 |
| 4.00 | Repairs to the 30-HP Starter (C&S Make) by way of providing and fitting of following accessories--- For WSS Tailbal Wangund.
Contactor coil of Range: 250-450 Volts, with 50 Hz frequency of TC make to be fitted to the 63 Ampere Contactor of the Starter.
Thermal Overload relay with a range of 28 to 40 Ampres of TC make and Confirming to IS/IEC 60947-4-1 & IEC60947-4-1
Push Buttons ON/OFF
The job includes fixing of the contactor coil and relay to the system and includes the cost on account of all accessories required for carrying out the said job. Once connected the system is to be tested on load for gauging the performance. | 1 | Comp Job | 8,000 ₹8,000 | 8,100 ₹8,100 |
| 5.00 | Repairs to 30 HP Mug-Starter (L&T Make) by way of providing and fitting of Single-Phase Preventer (Type: Controller SDz5) with the supply voltage of 380 Volts compatible to the Starter. The job includes removal of old damaged Single-phase preventer followed by replacement of the new one. The job further includes checking of all the circuit wiring and necessary repairs if required. The cost on account of all consumables required for carrying out the said job stands included in the scope of work. Once connected the system is to be tested on load for gauging the performance--- For WSS Tailbal Wangund. | 1 | Comp Job | 5,500 ₹5,500 | 5,700 ₹5,700 |
Updated dates
Tender Value
₹30,700
Closing Date
12 Feb 2026, 11:00 amClosed
Executive Engineer JS PHE Mech. Rural Div. Sgr.
Executive Engineer JS PHE Mech. Rural Div. Sgr.
Essential Electro Mechanical Works to Be Carried Out at Various Water Supply Schemes Under the Jurisdiction of PHE Mechanical Rural Sub-Division Srinagar.
2026_PHE_301725_1
PHE/MRD/TS 66 OF 01/2026
Open Tender
Miscellaneous Works
4 days
Srinagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹50
Executive Engineer JS PHE Mech. Rural Div. Sgr.
12 Feb 2026
29 Jan 2026
12 Feb 2026
29 Jan 2026
12 Feb 2026
29 Jan 2026
Providing/fitting of high-quality insulation tape rolls for day-to-day use at various water supply schemes.
Providing/fitting of Polymeric composite Pin insulators (5KV) as a replacement of damaged ones--- For WSS Chuntwaliwar 2nd
Supply, Installation, Testing and Commissioning of Post type Link set assembly complete in all respects for 11KV Power Supply as a replacement of damaged ones---For WSS Khonmoh Ist and WSS Samander Colony.
Repairs to the 30-HP Starter (C&S Make) by way of providing and fitting of following accessories--- For WSS Tailbal Wangund. Contactor coil of Range: 250-450 Volts, with 50 Hz frequency of TC make to be fitted to the 63 Ampere Contactor of the Starter. Thermal Overload relay with a range of 28 to 40 Ampres of TC make and Confirming to IS/IEC 60947-4-1 & IEC60947-4-1 Push Buttons ON/OFF The job includes fixing of the contactor coil and relay to the system and includes the cost on account of all accessories required for carrying out the said job. Once connected the system is to be tested on load for gauging the performance.
Repairs to 30 HP Mug-Starter (L&T Make) by way of providing and fitting of Single-Phase Preventer (Type: Controller SDz5) with the supply voltage of 380 Volts compatible to the Starter. The job includes removal of old damaged Single-phase preventer followed by replacement of the new one. The job further includes checking of all the circuit wiring and necessary repairs if required. The cost on account of all consumables required for carrying out the said job stands included in the scope of work. Once connected the system is to be tested on load for gauging the performance--- For WSS Tailbal Wangund.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_978934.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid