| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹31.4 L+₹2.6 L (8.88%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹33.0 L+₹4.1 L (14.2%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L3 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹92,500
Closing Date
7 Jul 2021, 6:00 pmClosed
GE (EAST) MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
SPL REPAIR FOR REPLACEMENT OF BER E/M PLANT PROVN OF 03 PHASE ELECTRIC CONNECTION WITH CHANGE OVER SWITCH FOR FIP MACHINE OF BLDG NO T89 BAHADURGARH PROVN OF GEYSERS AND EXHAUST FANS IN JCOS/OR MD ACCN FAFA AT PRATAP PARK AND OD COMPLEX JCOs/OR MESSE
2021_MES_447996_1
8200-1216/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (EAST) MATHURA
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (EAST) MATHURA
₹92,500
31 Jul 2021
3 Jun 2021
9 Jul 2021
3 Jun 2021
7 Jul 2021
25 Jun 2021
3 Jun 2021 - 30 Jun 2021
Amount
Supply, fixing and commissioning (Five star rated) suitable for 8 bar pressure, water heater (Geyser) storage type 25 liters capacity, 230 Volts, 50 Hz, vertical type, outer ABS rust free body, glass lined inner steel walled tank, grouting of studs in wall in cement mortar (1:3) including clamps, nuts, bolts, washers and provision of two numbers flesible hot water PVC connection heavy duty 450mm long with brass nuts, complete all as specified and directed.
S&F Sub main two single core PVC copper conductor unsheathed wire multi stranded 2.5 sqmm in through concealed PVC conduit not less than 20 mm dia including 2.5 sqmm copper conductor single core wire connected by common earth all as specified. (Note :- Three run of 2.5 sqmm cable & 20mm PVC Conduit shall measured as one unit length).
Supply and Fixing modular metal sunken box suitable for fixinng 3 module switch and socket flush into wall complete all as specified and directed by Engineer-in-charge.
Supply and Fixing modular white plate with cover suitable for fixinng 3 module switch and socket complete all as specified and directed by Engineer-in-charge.
Supply and Fixing one way modular switch 16 Amp, one module suitable for 230volts AC complete all as specified and directed by Engineer-in-charge.
Supply and Fixing modular socket 16 Amp, two module , 3 pin suitable for 230volts AC complete all as specified and directed by Engineer-in-charge.
Supply, installing, commissioning and testing, hi wall split type Air Conditioner of nominal capacity 2.0 TR (Dual mode Hot & cold, inverter type, withstand any climatic condition and delever precision cooling up to 0.1 C with the option of the both hot and cool, with dual rotor inverter compressor and copper compressor, suitable for working on 230 volts, single phase,50 HZ supply and 4 star energy rated complete including cutting of wall providing stand for outdoor unit and making good disturbed surface of wall etc and remote operation complete all as specified and directed Make:- Hitachi/Carrier/Daikin/Blue star Note:- Rate are included in quoted by contractor for following items are as under:- (a) Fixing the cooling unit with grouting nuts, cutting groove to wall for gas pipe & water drainage pipe (b) S&F PVC Pipe 15/20 mm dia transparent flexible heavy duty for water drainage pipe of required length at site. (c ) Insulation of both the copper pipes with insulating material and covering the complete pipe with PVC casing & capping of size 75x75 mm/ reqd size of mechanical protection of copper pipe complete. (d) Charging of correct qty of refrigerant gas after necessary brazing/fixing of both the outdoor/indoor unit and testing complete on load to obtain 18 degree Celsius temperature at specified amps. (e) M&L for provision of shed for outdoor unit made of MS sheet 2.0mm thick and MS angle 40x40x6mm of reqd size including applying two coats of synthetic enamel paint over a coat of red oxide primer and necessary PCC works as site requirement complete all as specified and directed. (f) All other connected civil work & other misc work reqd for installation of split AC for proper functioning as directed by EIC.
S & F wall mounted type line-Voltage Stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and speed of correction 8 volt per second complete all as specified and directed. Make : V-guard/Microtex/AE/CG.
Supply and Fixing Desert cooler, electric driven motor with copper winding,speed 1400 RPM ,single phase, having nominal air flow capacity of 4000 CUM per hour , steel body 22 SWG complete all as specified and directed. Make :- Can star/Crompton/Symphony
M & L for point wiring for independent socket point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated FRLS , unsheathed multi strand copper conductor cable FR-LS cable 1.5 sqmm (phase-Red,Neutral-Black,Earth-Green) drawn into and including concealed rigid non metallic PVC Conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and sunken GI pressed steel terminal boxes covered with 3 mm thick phenolic laminated top sheet cover white for 6 Amp multi purpose switch socket on independent board all complete as directed.
S&F switch socket combination flush type outlet multipurpose 3 Pin 5 Amp 230 volts AC complete all as specified.
Excavating in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out in soft/loose soil all as specified and as directed by Engr-In-Charge.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified.
Supply and laying un-reinforced precast concrete cable cover class LV type I flat of size 250mm x 150mm x 40mm all as specified factory made ISI marked.
M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. Note:- Measurement shall be taken after gentling punning.
Supply and lay GI tubing, light grade, 50 mm bore dia as cable protection fixed on walls/poles/laid in trenches complete including dismantling corroded GI pipe all as specified and as directed.
Supply and lay XLPE insulated screened PVC bedded galvanised steel strip or wire armoured U/G cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified.
Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0 mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI earth strip of size 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore light grade GI pipe for protection of earth strip and connect to eqpt /LA /panel point with use of Porceline insulator where required, common salt, charcoal dust including provision of earth test Point for earth test complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost all as directed by Engr-in-Charge. (Note: GI strip upto 7.5mm length from earth electrode shall be deemed to be included in unit rate).
M & L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia medium grade) and its all accessories complete concealed in wall incl cutting & chases( making good all to the disturbed surfaces as per existing) including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour complete all as specified in current SSR Part-I & II & directed by the Engineer-in-Charge , as described below:-
a) One exhaust fan point controlled by one way Modular switch 5 amp complete.
All as per item No. 21 but for 3 pin / 5 pin 16 Amps Modular sockets outlet with 2.5 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent complete all as specified and as directed .
Supply and Fixing ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified.
Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete all as specified.
Supply and Fixing Modular switch 16 Amp single pole one way,1 Module all as specified.
M&L for Modular metal flush box 1 Module including modular white cover with frame all as specified and directed.
M&L for Modular metal flush box 3 Module including modular white cover with frame all as specified and directed.
Supply and Fixing Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete all as specified.
Supply and fix exhaust fan made of sturdy engineering plastic 250 mm sweep alongwith louvers/front grill complete suitable to work on AC, single phase, 230 volts, copper winding, 50 Hz supply and including connecting up with twin core twisted flexible copper conductor cable of suitable size 0.75 Sqmm, Including supply and fixing plywood not more than 1x1 mtr on existing surface with all required accessories to fix exhuast fan on existing surface including making good and finished properly all as specified and directed by Engr-in-charge.
Supply and fix exhaust fan, steel body 450 mm sweep alongwith louvers/front grill complete suitable to work on AC, single phase, 230 Volts, 1400 RPM , copper winding, 50 Hz supply and including connecting up with twin core twisted flexible copper conductor cable of suitable size 0.75 Sqmm, complete all as directed by Engr-in-charge.
Supply and Fixing water heater storage type, copper inner tank, electric, heating element upto 2 KW, capacity 50 Ltrs BEE 5 star rated complete with all accessories.
Supply ,laying, jointing and testing only of GI tubing medium grade 15 mm bore with all fittings laid in trenches/wall (including cutting and chasing) & making good all to disturbed surfaces as per existing complete all as specified and directed.
S&F Stop valve, cast copper alloy, fancy type, chromium plated with long shank and cup (connected type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for fixing GI pipe size 15 mm dia.
Supply and fix Cock, bib, cast copper alloy with crutch or butterfly handle, chromium plated, screwed down For size 15 mm (1/24”) dia pipe.
Cutting holes for air ducting of exhaust fan in circle / square shape or as per site requirement into or through concrete walls built in cement mortar of superficial area exc 400 sq.cm but n.exc 0.10 sq.m to a depth of 30cm including making good in cement mortar 1:3 or cementconcrete M-15 grade (Nominal mix) using 20mm graded stone aggregate as required and rubbish off the premises.
Supply, fixing, installing testing and commissioning silent/containerzed diesel engine driven generating set complete to give an out put of 5 KVA at AC 415 Volt, 50 Cycles per second, 3 phase, 4 wire supply with power factor 0.8, 1500 RPM diesel engine and alternator mounted on common base plate, anti vibration rubber mounting pad (AVM Pads "B" series) complete in all respect with and including accessories and components as specified below including sound proof integral accoustic enclosure for 05 KVA Gen sets ECO friendly and as per Ministery of Environment, forests notification 17 May 2002 complete including, emergency stop button, illumination inside canopy, Temperature sensor for high temp safety, exhaust fan etc complete as per IS 4722 AMF type with relay panel for automatic starting on mains failure complete.
(a) Diesel driven Engine(Prime mover) Multi cylinder vertical/horizontal, 4 stroke cycle,suitable for 5 kva alternator, water cooled confirming to BSS -649 rated for continuous running diesel engine suitable to devolpe matching BHP at 1500 RPM as per latest ISS/BSS,capable of taking 10% over load for any one hour in any 12 hour running complete with and including following accessories:- (i) Fuel Filter (ii) Governor (iii) Complete battery set with lead & lugs as recommended by manufacturer. (iv) Lubricant oil cooler. (v) Lubricant oil filter. (vi) lubricant oil Pump. (vii) Digital oil pressure guage. (viii) Any other parts as presicribed by manufacturer for making it functional. (ix) Battery charging alternator of suitable capacity. (x) Dry type air filter. (xi) MS Chanel fabricated frame rigidly welded suitable for reciving the diesel engine and alternator and anty vibration pads. (xii) Coupling guard. surface, floor mounted with suitable angle iron supports. (xiii) Exhaust pipe fully extended to exhaust gases out side the aquastic enclosure including silencer and necessary insulation lagging with minimum 12mm dia asbostes rope. (xiv) Fuel tank of sheet steel and of capacity for 12 hours running on full load with inlet and outlet connection,filling cap,drain valve,air vent,calibrated scale on outer surface,floor mounted with suitable angle iron supports. (xv) Digital type RPM Meter. (xvi) self starter on suitable size (xvii) Turbo charger. (xviii) in line monoblock. (xix) Fuel pump. (xx) digital type coolant temprature guage. (xxi) self starter with auto electric start accessories. (xxii) Engine saftey low lubricant oil pressure and high coolant temprature. (xxiii) operating manual. (xxiv) Test certificate.
(b) Alternator;- 5 KVA at 0.8 PF self excited regulated with fast response thyristor type,3 phase 50hz,415 volts,1500rpm, 4 wire alternator,screen protected drip proof free from commutation proble,continous rating confirming to BS-649 complete with automatic voltage regulator out put voltage regulated between +/- 1% of set volts from no load to full load with following accessories. (i) Universal type energy meter -01 No (ii) under/over voltage relay-01 nos
(iii) frequency meter digital type -01 nos (iv) Digital electronic timer-01 Nos (v) indicating lamp LED base with toggle switches-01 set of three (vi) KWH meter three phase digital type -01 Nos (vii) PF meter three phase digital type -01 Nos (viii) Test of Gen set as specified in PS (ix) ON LOAD change over switches 415 volts sheet metal enclosure 4 pole of suitable capacity (c ) FOUNDATION:- Complete as per manufacture desigen with anty vibration pads including necessary excavation,earth work,returning filling,sand cushioning, grouting in foundation etc. (d) ACOUSTIC ENCLOSURE:- supply and install of acoustic enclosure suitable for 5 KVA dg set as under. (i) Fabricated out of CRCA sheet of suitable thickness as per manufacture design.polyster based powder coated internally and externally with lockable type door handle .All nuts and handles shall be zinc coated. (ii) The doors are gasketed with EPDM gaskets (iii) sound proofing with high quqlity rock wool/mineral wool/foam proofing confirming to is 8183 of 50mm thickness and density at 96kg/M3 coverd with fiber glass cloth and per forated powder coats sheet specially designed allenuators (sound controller) at air entry and exit of the container noice level shall be not exceed 75db at 1 meter distance as per CPCB norms.
(iv) Adequate ventilation to meet air requirment for combustion and heat removel with provision of blower. (V)Emergency stop push button out side the container. (vii) Provn of light inside the canopy providing of FTL 1x20 watt with wiring and control switch. (E) MOUNTING ARRANGMENTS:- Prime mover and alter nator shall be mounted on skid mounting type base frame fabricated from ISMC channel or in sheet metal providing comman bed for engine and alternator directly coupled togther the base frame has provn for grouting on foundation bolt as well as fixing on vibration mounting provision is made in base frame for tilting arrangments of DG Set as recomended by manufacturer the base frame shall have provision for mounting of aquastic enclosure . the base frame to have provision of lifting hook for convenent lifting of complete se i.e along the canopy engine and alternator. (F) AMF PANEL:- AMF control panel out door type made out of MS sheet of 3.15 mm thick with duly powder coated & mounted on angle iron frame made out of size 50x50x6mm, 90 cm high consisting of the following accessories :- (i) Aluminium busbar of 63 Amp for three phase and of 40 Amp for neutral. (ii) MCCB TPN 415 volts 40 Amp. 16 KA adjustable type ---02 Nos (incomings for Main & DG set ) (iii) Change over switch four poles 415 volts, 50Hz AC of capacity 40 Amp front operated.--02 Nos (For bypass arrangement)
(iv) Power contactor Three poles 415 volts, for suitable ratings ---- 02 Nos.(For DG & Main) (v) Under/ over voltage relay 415 volts --02 Nos (For DG & Main) (vi) AC Timer 230 volts AC with 2NO+ 2NC --01 Nos (vii) DC Timer 12/24 volts DC --01 Nos (viii) Engine star relay 12 volts DC --01 Nos (ix) Step down transformer 230/12-24 volts --01 Nos (x) Rectifier of suitable rating --01 Nos (xi) LED Indicating lamp cluster type set of three in RED/BLUE/ GREEN colour. ---- 02 Sets ( For DG & Main) (xii) LED Indicating light for DG & Main ---- 02 Nos (xiii) LED Indicating light for battery charger ---- 01 Nos (xiv) Digital multifunction meter with volmeter (0-500V), Ampmeter (0-250) & frequency meter ---01 Nos (xv) CT coil 200/5Amp --- 03 Nos (xvi) Digital type DC volt meter (0-30V) --- 01 Nos. (xvii) Digital type DC Ammeter (0- 15A ) ---01 Nos. (xviii) Trickle/ Boost switch ---01 Nos (ixx) Auto/ Manual switch ---01 Nos (xx) Start/ stop push buton ---02 Nos (xxi) Digital type frequency meter ---01 Nos (xxii) Control relays ---01 Set (xxiii) Over load relay ---01 Nos (xxiv) Hooter 12 V DC--01 Nos (xxv) Control MCB SP 6 Amp 230 V --- 06 Nos (xxvi) Grouting of panel 60cm above GL, embedded in PCC (1:2:4) using 20 mm graded stone aggregate up to 30 cm complete.
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supplying, transporting to site, erecting and fixing in true vertical position of steel tubular swaged pole, 9 metres long, type 410, SP-31, with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc & including painting with two coats of aluminium paint over and including one coat of aluminium oxide primer and two coats of bituminous paint inside and outside of bottom portion which embedded in concrete upto 1.80 m height of pole and including fixing of 6" width reflection paint in alternate coloured on pole and marking pole Nos with black synthetic enamel paint complete all as specified and directed. Note:- Excavation and earth work, PCC etc shall be measured and paid for separately under respective items of BOQ.
M & L for cement concrete PCC M-7.5 grade (Nomianl mix) using 40mm graded crushed stone aggregate as in pole foundation and like complete all as specified and directed.
M & L for cement concrete PCC M-10 grade (Nomianl mix) using 20mm graded crushed stone aggregate as in pole coping and like complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core.
S & F of circuit main wiring for junction box to street light fitting of size 1.5 Sqmm 3 core, PVC insulated and PVC round sheathed multistranded copper conductor flexible industrial FRLS cable, 1100 V grade, confirming to IS:694:1990 & including fixing arrangement complete all as specified and directed. Note :- Cost of Necessary tools and plants such as ladders, hydra for connection to street light fittings etc shall be deemed to be included in the unit rate quoted.
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burred in ground vertically earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4.0 sqmm dia by means of GI nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate upto 5 mtr and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion.
Supply, installing, commissioning and testing of LT Panel factory made CPRI approved outdoor type, cubicle type, floor mounted complete with aluminum bus bar, 4 wire, 3 phase, 200 Amps comprising of following:- (a) MCB 16 Amp Four Pole of rating 10 KA – 01 Nos for incoming (b) MCB 10 Amp TPN of rating 10 KA – 01 Nos for out going (c) Timer switch TP 20 Amps -01 No (d) Onload change over switch four pole16 Amps - 01 No (e) Digital Ampere meter 0-200 Amp – 01 No (f) Digital Voltmeter 0-500 V - 01 No (g) Indicating lamp RYB - 01 set
Material and labour street light fitting bracket made out of 40mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall with and including two sets of clamps made out of flat iron of size 50 x 6 mm with bolts, nuts and washers complete.
Supply and fixing junction box out door type of external dimensions 250 mm x 200 mm x 105 mm, single door type hinged with locking arrangement front operated, 3 phase and neutral bus bar including connecting the incoming/out going cables with nuts, bolts etc complete. Make - Cat part No GSJB of syntax or equivalent in Hensel/RMW
S&F MCB 6 Amp to 20 Amp SP capacities 'C' series 10KA rupturing capacaity complete all as specified and directed. Make:-Havells/Anchor/Legrand/ABB
Ms Kamal Kant Agarwal
Unnati Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .