Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.83Accepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹47.9 L+₹9,392 (0.20%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹45.8 L
EMD Value
₹91,660
Closing Date
26 Dec 2024, 5:30 pmClosed
NAVIN KUMAR
ED - Gurgaon
special repair to E.I. in admin block and technical block and special repair of transformer in Govt. Polytechnic Uttawar in District Palwal
2024_HRY_417403_1
20247A40FBEF A086 450E 8759 7D15B32FB520664BAR
Open Tender
Civil Works
Works
120 days
UTTAWAR
2 documents required · 2 mandatory
₹5,000
₹91,660
Yes
1 Jul 2025
16 Dec 2024
27 Dec 2024
16 Dec 2024
26 Dec 2024
16 Dec 2024
16 Dec 2024 - 17 Dec 2024
Amount
Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 48" (1200mm)
COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS Wiring only in 1.5 sqmm PVC insulated copper conductor cable for LIGHT/FAN/Call bell point in existing conduit pipe and MS boxes including cost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connector etc. Group B
Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch etc complete as required Group B
Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required Group B
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)
1 run of Size 4 Sqmm(1/2.24mm)
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work.PVC pipe of 25 mm dia.
FITTING AND ACCESSORIES Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Switch 5 amp. on existing sheet.
Wall socket 5 amp on existing sheet.
Call bell 220/230 volts musical type
Bell push
Bakelite angle/straight button holder large size.
Socket size rotary step type Electronic regulator for A.C. ceiling fan
Supply and Fixing Bakelite sheet on existing MS/GI/wooden/PVC box etc including fixing with brass screws and washers. 5 mm thick
Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.
Providing and fixing outdoor duty Ply of 8 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required
Replacement of a fan condenser complete with connections and testing etc. 2 to 3.5 mfd
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required.
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. Triple pole MCCB 200 to 250 Amp, 25 KA
4 pole MCCB 125 to 160 amp, 25 KA
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)
TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
40 amp to 63 amp. Double pole
40 amp to 63 amp. MCB's Four Pole
DISMANTLING Dismantling old wiring points ( Recess wiring or partly recess partly surface system , recess Conduit and box not to be dismantled ) including necessary repairs to wall etc. Light, fan or call bell Point including circuit/sub main wiring Wall socket point including circuit/submain wiring
Wall socket point including circuit/submain wiring
EARTHING AND LIGHTENING ARRESTOR Earthing with G.I. earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
Extra for using salt and char coal/coke for pipe earth electrode as required.
Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
Supplying and laying 25mm x 3mm G.I. strip at 0.5 P.mtr. below ground as strip earth electrode including soldering etc. as required.
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
Supply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work. 1.5 sqmm
S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
Providing & erection/ laying of PVC/ XLPE insulated underground aluminium conductor underground cable loose in existing pipe or trenches complete in all respect with necessary connection upto the entire satisfaction of engineer in charge of the work. 16 Sq mm 4 core (Arm.)
35 Sq mm 3.5 core (Arm.)
Providing & erection/ laying of PVC/ XLPE insulated underground aluminium conductor underground cable on surface/ existing cable tray complete in all respect with necessary connection upto the entire satisfaction of engineer in charge of the work 16 Sq mm 2core (Arm.)
Supply and erection of PVC round sheathed multicore annealed bare copper conductor cable 1100 volts grade in pipe of suitable size excluding cost and erection of pipe complete in all respect upto the entire satisfaction of Engineer in charge of the work 1.5 sq.mm 2 core copper wire
Supply and erection of 150 watt LED floodlight made up of pressure die cast aluminum housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. System efficacy ≥ 110 LPW 10KV SPD included including erection of same on pole/ parapet with necessary nuts & bolts and making necessary connection of same complete in all respect.
Supply and erection of 90 watts LED streetlight made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 Protection including erection of same on pole with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge.
Supply, Erection, testing and commissioning of Transformer-500 KVA 11/0.433 K. V.3 Phase-50 cycles copper wound outdoor type as per latest IS specification efficency level 3 confirming to IS 1180 and IS 2026 with losses at 50% load 1354W, 100% load 3909 W duly laid on existing foundation at site of work, along with petty works required up to the entire satisfaction of the Engineer-in-charge of work as per detailed specification given as under: No. load voltage ratio 11/0.433 K V. No. of Phase = 3 Frequency cycles = 50HZ Type- double wound core type copper wound Cooling = ONAN Duty = Outdoor Vector group/ISS-DYN 11 Tapping on HV Compensation +5.0% To-10% in steps of 2.50%. Temperature rise (oil/Res = 0C) 40/45 C Attitude= upto 1000metres above M.S.L. Fitting/Accessories Provided. Bucholez relay with alarm and trip contact. OFF LOAD TAP CHANGER Externally hand operated. Oil conservator with Filling hole & cap. Plain oil level guage with minimum Level marking. other specifications as per other specifications as per DNIT in PDF. Operating handle
Supply, installation, testing and commissioning of HT panel 1 way RMU type (1 VCB + 2 loadbreak switches) outdoor type Make ABB/Siemens/ Schneider complete upto the entire satisfaction of the Engineer - in - Charge as per specification as under :- with standard protection devices VACCUM CIRCUIT BREAKER Vacuum circuit breaker 12kV, 630A Bushings outside cone interface C for connection of external busbar Manometer Stored energy mech. For manual operation, with trip coil open Control voltage, trip coil 24 V DC as per other specifications as per DNIT in PDF.
Supply, installation, testing and commissioning of APFC panel complete upto the entire satisfaction of the Engineer - in - Charge as per specification as under :- APFC PANEL (200KVAR) 200KVAR Automatic power factor correction panel in 12 steps (25 KVAR x 6 + 10 KVAR x 4 + 5KVAR x 2) consisting of following 320Amps 433V 3P 50KA Manual Fixed Type Moulded Case Circuit Breaker (MCCB) with Thermal mangetic based release for over current and magnetic short circuit as incomer to APFC Panel (with TMA release) (Make: ABB /Siemens/ Schneider/L&T) = 1 no. as per other specifications as per DNIT in PDF. FAN for heat dissipation & cooling of capacitor bank = 1 no.
Servicing/ overhauling of 500 KVA Transformer with new oil complete the job in all respect upto entire satisfaction of Engineer - in- Charge as per following work :- Complete service / overhauling, Oiling and Greasing work New Oil top-up 600 ltr. As BDV value is very down Transformer coil, R-Y Rewinding Installation of new Breather set complete with silica Gel Complete Paint work of 500 KVA Transformer Loading, unloading and Freight charges for Transformer work Comlete Transformer Earthing work as per norms
Repairing / Servicing of LT panel with complete maintenance complete the job in all respect upto entire satisfaction of Engineer - in- Charge as per following work :- Complete service / overhauling, Oiling and Greasing work Complete LTp anel paint work Installation of voltmeter, Amp. Meter, R-Y-B Indicators All 3 ACB (Air circuit Breaker) repairing Complete Testing and checking of LT panel Complete LT panel earthing as per norms Supply of 4 pole 3 nos. 250A MCCB Make L&T, Schneider, C&S Supply of 4 nos. 250A 4 pole Manual Changeover without enclosure Make L&T, Siemens, C&S
Repairing / Servicing of capacitor bank 1 work complete the job in all respect upto entire satisfaction of Engineer - in- Charge as per following work :- Servicing/ overhauling, oiling and greasing work Complete LT panel paint work Testing & checking of complete LT panel Continuity checking of control cables, power cables overload relay functional checking, dooor limit switch function Regulator functional checking (manual & auto) Power fuse links failure checking Checking door interlocking with breaker
Buyback cost of old 500 KVA Transformer
Buyback cost of old HT panel
Buyback cost of old capacitor bank
KKM Engineering Solutions Pvt. Ltd. (BID ID -1189410)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .