| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.5 L+₹3.1 L (11.0%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹32.9 L+₹4.5 L (16.1%)Rejected-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L3 | Rejected-AOC L3 | |
| 4 | L4₹35.7 L+₹7.3 L (25.9%)Rejected-AOC RZ D 29A GALI NO 05 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-AOC L4 | |
| 5 | L5₹37.3 L+₹9.0 L (31.6%)Rejected-AOC WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-AOC L5 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
8 Jul 2023, 6:00 pmClosed
GE Bharatpur
Kanjoli line Bharatpur
Repair to LT external electric supply LT cables LT OH lines, LT Panels and connected works at RMS Dholpur under GE Bharatpur
2023_MES_602465_1
8261/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RMS Dholpur Under GE Bharatpur
As per NIT
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹60,000
Yes
26 Jul 2023
10 Jun 2023
10 Jul 2023
10 Jun 2023
8 Jul 2023
26 Jun 2023
12 Jun 2023 - 24 Jun 2023
Amount
Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft diintrigrated rock complete all as specified and directed.
Excavation in trenches, n. exc 1.5 Mtr wide and exc 1.5 Mtr in depth for pole and getting out in soft soft diintrigrated rock complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified and directed.
Supply & spread unwashed dry river sand for sand cushioning for covering the under ground cable in trenches complete all as specified and directed. (Note :- Punning thickness shall be measured.)
M&L for cable protection cover with sub Class`B` bricks old size laid dry, flat perpendicular across the cable in trenches complete all as specified and directed.
M/L for taking out Unsv U/G cable PVC insulated armoured PVC sheathed Al. Conductor, LT cable of any size complete all as specified and directed.
10 to16 sqmm
25 to 50 sqmm
70 to 95 sqmm
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:-
95 Sqmm 3.5 core
70 Sqmm 3.5 core
50 Sqmm 3.5 core
25 Sqmm 4 core
16 Sqmm 4 core
10 Sqmm 2 core
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable of 3 core 95 Sqmm with stranded copper conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole complete all as specified and directed.
S&F in repair on existing location including taking out of existing MCCBs of following capacity :-
MCCB 415 volts thermal magnetic release adjustable type 400 Amps 04 pole 50KA
MCCB 415 volts thermal magnetic release adjustable type 250 Amps 04 pole 36 KA
MCCB 415 volts thermal magnetic release adjustable type 200 Amps 04 pole 36 KA
MCCB 415 volts thermal magnetic release adjustable type 160 Amps 03 pole 36 KA
MCCB 415 volts thermal magnetic release adjustable type 100 Amps 04 pole 25 KA
MCCB 415 volts thermal magnetic release adjustable type 63 Amps 04 pole 25 KA
S & F or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable old pipe on poles/walls under road crossing of size 50mm bore complete all as specified and directed.
M&L for road cutting in 300mm width & 450mm depth & repair to existing with bitumen premixed incl 150mm WBM complete all as specified and as dirceted
M&L for LT cable fault rectification upto 240 sqmm X 3.5/4 core by using Fault locator machine to detect fault and rectify the same incl T&P & items ie lugs,tape etc complete all as specified and directed by Engr-in-charge.
M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of following size after detaction of fault location .Make:3 M,Denson or equivalent complete all as specified and directed. Note: Earth work and returning filling which require in above job will be measured and paid seperataly.
25 Sqmm to 50 Sqmm
70 Sqmm to 120 Sqmm
Complete paint removing from surface of Panel box and M & L for 02 coats of painting with approved colour of synthetic enamelled paint over a coat of red oxide primer for size of Panel boxes from all in & out side incl angle iron frame work min 04 Sqm area of sheets including angles canopy and legs etc complete all as specified and directed. Note: Permission to shutdown of electric supply to the panel to be taken from MES before commencement of work.
Material and labour for renewal of Chemical Earthing complete with copper earth plate electrode of size 60x60cmx3mm thick buried directly in ground (earth pit should not less than 4 mtr deep below normal ground level ) with top edge of the plate not less than 2.95 mtr deep below normal ground connected to and included copper earth strip 50mmx 6mm by means of copper bolts nuts check nuts and washer returning and filling the pits with excaviated vsoil mixing with charcoal 250 kg crystal salt 200 kg magnisiun sulphate of 100 kg and vegitable soil all around the plate up to 350 mm above from top edge of plate and balence portion filling with excaviated soil in layers not exc 25 mm thick 25 mm bore galvanised iron medium grade watering pipe up to top of plate 50mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil pcc pit with cover ,funnel,with wire mesh complete all as specied and directed. Note (i) Quoted rate shall be deemed to include for earth strip with protection pipe up to 7.5 M length
M&L for cement concrete 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foudation,fillinf and mass concrete complete all as specified and directed.
Demolition of old PCC and M&L for cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal of poles/ coping including necessary formwork, fair finishing to exposed surfaces using extra cement complete all as specified and directed.
M&L for disconnection of LT panel incl LT cables of size upto 120Sqmm X 3.5/4core from existing foundation and reconnection with same panel after taking necessary corrective action to lift the panel height incl excavation and taking down existing cable with loop, providing new AL lugs and cable gland of appropriate size,insulation tape etc to restore electric supply incl necessary iron work to modify height of existing LT panel upto 1.2 Mtrs above existing level incl necessary welding work,nuts & bolts and 2 coat of paint with existing color over one coat of primer and required necessary PCC work complete all as specified and directed by Engr-in-charge. Note: PCC shall be measured & paid separately under respective item.
Supply and fixing in replacement of Lithium base Energy efficient integrated Solar street light of 32 watt in single FRP body duly polyurethane coating (Camouflage color), encases with monocrystalline solar PV panel of 65-67Wp,lithium battery 11.1/12.8V,33.0 AH with inbuilt BMS,IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminium reflector for better light distribution ,CRI>70, color temp 5700K-6500K Microcontroller based charge controller cum driver,automaticdimming function(First 04 hrs at full brightness & rest of the time at lower light level with PIR motion sensor), Dusk to dawn operation,suitable to working temp (-) 10C to (+) 55C ,weight not more thatn 16-18 Kg with adjustable MS clamp suitable for pole/wall mounting etc complete all as specified and directed. Make: AXXON/HAVELLS/PHILLIPS/CG Protections: Short circuit, overload,Reserve polarity and battery protection.Firm should provide vital parametres Test report from NABL accredited lab and should be of made in India with CE & ROHS complaint. (Excavation & earth work shall be measured separately)
S&F in replacement new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 60 watts (Surge protection of the light should be 10 KV )with suitable drivers etc and connecting with 4.0 sqmm aluminium solid conductor PVC insulated twin core weather proof cable etc, fixing to wall / pole with and including bracket made out of GI pipe of 40mm dia light grade not less than 1.5 mtr long, bent to shape, fixed to Pole/Wall in any position with flat iron clamps of size 40 x 6mm complete all as specified and directed. Make:- Crompton / Philips/Bajaj/Havells.
Trimming/prunning and removing of tree branches or any other forein objects from LT /HT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system complete all as specified and directed. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. (iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering and stringing the ACSR conductor etc.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type and including bracket of 40mm dia and clamp of 40x 6mm complete and including pipe 40mm light grade of 1.5mtr lenth complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
dismantling of old UNSV ACSR conductors M&L for stringing ACSR conductor LT Over Head line in Gundrai feeder 2 to 6 runs of weasel/Mink with permissible sag as per IS rules etc complete all as specified and directed by Engineer in Charge.
Dismantling of corroded out and broken Cross arms and M&L for cross arms, bracings, supports, clamps and back plates etc fabricated from structural steel section incl nuts bolts and washers, welding, bending, cold or hot, drilling holes for bolts, in any shape complete all as specified and directed by Engineer in Charge
M&L insulator shackle type porcelaine vitreous white/green or brown in colour incl one MS galvanised spindle , iron washers and iron nut bolts of size 100mm hieght , 115mm dia, section of straps 31 x 05mm, for 1100 volts grade complete all as specified and directed by Engineer in Charge. Make:Jaypuria
M&L insulator pin type porcelaine vitreous white/green or brown in colour incl one MS galvanised spindle , iron washers and iron nut bolts of size 100mm hieght , 65mm dia for 1100 volts grade complete all as specified and directed by Engineer in Charge. Make: Jaypuria
taking out old UNSV plate earthing any type Material and labour for bore well earthing with the help of mechanical boring machine of 150mm dia 30mtr depth, supply and fix 150 mm bore , UPVC pipe 6 kg/sqcm rating, 06 mtr long with the help of suitable size clamp with nut bolt and washer -01no including charcoal dust, salt fill in bore well for achieve earth conductivity less than 1 ohm. M&L for covering of bore well mouth with PCC (1:2:4) type B-1/Brick masonry pit of size 45x45x45 cm complete and give the mimimum earth test result below 1 ohm complete all as specified and directed by Engineer-in-Charge. Note :- (i) The earth pit shall be refilled by boulders free from vegetable soil. (ii) Earthing shall be tested by contractor in presence of Engr-in-charge. Record shall be maintained.Payment shall be admissible only after satisfactory test results. (iii) GI pipe electrode and GI strip shall be measured & paid separately.
Supply & lowering of GI tubing 50mm dia medium grade in incl necessary fittings for lowering in borewell of depth upto 30 mtr and providing necessary holes in pipe to achieve good earth conductivity complete all as specified and directed.
S&F GI Strip 32x6mm fixed on wall or buried in ground or any other indicated situation complete all as specified and as directed Note:- Extra GI strip consider for borewell earthing which for existing earthing location
M/S MAKHIJA TRADERS
Vijay Electricals
SHREE RAM BUILD TECH
imran construction company
Ayushmat Contractors
NAVEEN TRADERS
Rahul Enterprises
M/s M M BAHL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .