Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC 34 1 TILAK NAGAR KOLKATA 700040 | KOLKATA | KOLKATA | WEST BENGAL | 700040 | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.1 L+₹1.4 L (5.41%)Rejected-Finance 13 RAMLAL MUKHARJEE LANE P O KHAGRA P S BERHAMPORE DIST MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | L2 | Rejected-Finance L2 | |
| 3 | L3₹28.0 L+₹2.2 L (8.66%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance L3 | |
| 4 | L4₹30.7 L+₹4.9 L (19.1%)Rejected-Finance 1 AJC BOSE ROAD KOLKATA 700 020 | KOLKATA | KOLKATA | WEST BENGAL | 700020 | L4 | Rejected-Finance L4 | |
| 5 | L5₹31.0 L+₹5.2 L (20.4%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
28 Nov 2020, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE KNED PWDTE
OFFICE OF EE KNED PWDTE P5 CIT Road 2nd Floor Moulali Kolkata 700 014
Electrical renovation of Auditorium hall at Centenary Building 2nd Floor of Calcutta University College street Campus EI work including installation of different type luminaries
2020_WBPWD_305340_1
WBPWD/EE/KNED/NIT-17 of 2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
CALCUTTA UNIVERSITY
Please refer Tender documents.
3 documents required · 3 mandatory
₹76,000
8 Mar 2021
14 Nov 2020
1 Dec 2020
14 Nov 2020
28 Nov 2020
14 Nov 2020
120 days
Amount
Dismantling of the existing damaged main switch, SPNDB, switch boards, old fans, old tube fittings, power plugs,GI pipe, computer boards, cables, damaged wiring etc including MS clamp by cutting wall & mending good the damages and deposited to University store with well manner.
S & F 415V, 8 Way Double Door VTPN DB (Legrand make Cat No. 607914/L&T/Crabtree) on wall by iron angle and mending good the damages to original finish including interconnection with suitable size of cu. Wire and and nutral link of provision fo earthing attachment consisting with S & F 1 No. 160 A 4 pole MCCB ,8Nos. 63A TP MCB.
S & F double door powder coated cable end box suitable for 8 way VTPN DB with IP-42/43 protection on angle iron frame on wall incl. earthing attachment as per GS.
S & F double door 8 wayTPN MCBDB with IP-42/43 protection concealed in wall incl.S & F 1no.415V 100 A four pole isolator as incomer & 24 nos. 16-32A SP MCB as outgoing incl. inter connection with suitable size cu.wire & mending good the damages to original finish.(Legrand make cat no.607717/L&T/Crabtree )
S & F double door powder coated cable end box suitable for 8 way HTPN DB with IP-42/43 protection on angle iron frame on wall incl. earthing attachment as per GS. (Make: Legrand/L&T/Crabtree)
S & F 240 V 6-10A per way (12+2) way SPN MCB DB with SS encloser Double door with 1no. 40 A DP isolater as incommer & 12 nos. SPMCB ( C curve ) as outgoing on angle iron frame on wall as per G.S. (Legrand Make. Cat no. 607712/L&T/Crabtree)
Supply & Laying 1.1 KV grade 4 core 95 sq mm PVC/A Al. cable (Gloster/KEI/Havells/Polycab) incl S & F 2x10 SWG GI wire as Earthing through following process as per direction of EIC.
On wall/surface by saddling
Supply & Laying 1.1 KV grade 4 core 70 sq mm PVC/A Al. cable (Gloster/KEI/Havells/Polycab) incl S & F 2x10 SWG GI wire as Earthing through following process as per direction of EIC.
On wall/surface by saddling
Supply & Laying 1.1 KV grade 4 core 300 sq mm PVC/A Al. cable (Gloster/KEI/Havells/Polycab) incl S & F 2x8 SWG GI wire as Earthing through following process as per direction of EIC.
On wall/surface by saddling
S &F compression type gland complete with brass gland, brass ring etc. incl. finishing the ends by crimping method as per GS.
For 4 core 95 sq mm PVC/A Al. cable
For 4 core 70 sq mm PVC/A Al. cable
For 4 core 300 sq mm PVC/A Al. cable
Supplying and fixing 240/415 V, 6-32 Amp SPMCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand/Crabtree/L&T/ABB)
Supplying and fixing 240/415 V, 40 Amp DPMCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand/Crabtree/L&T/ABB)
Charge for dismantling 2+8 way double door Horizontal SPN MCB DB with all accessories & Fixing only the same at different location ; to be concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection & provision for earthing attachment as per direction of EIC .
Charge for dismantling 4 way double door Horizontal TPN MCB DB with all accessories & Fixing only the same at different location ; to be concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection & provision for earthing attachment as per direction of EIC .
Supplying and fixing 415V, TPN SFU openexecution in existing SS enclosure/cubical with nutsbolts etc incl. S & F 3 nos. DIN type HRC fuse asper rating. 250 Amp (Make-L&T,ABB,Siemens)
Distn. wiring in 1.1kV Gr. 4x16 sqmm + 2x10sqmm (from VTPN DB to TPN DB) [2x16sqmm+1x10sqmm in each 25mm pipe, i.e. 2 parallel 25mm size PVC rigid conduit to be laid] single core stranded 'FR' PVC insulated & unsheathed Cu wire in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as reqd. as per direction of EIC at Corridor from Panel to TPN DB.
Supply, Delivery,Testing & Commissioning of Cubical type floor cum wall mounted LT panel (CPRI test is mandetory) of suitable dimension (1900 mm x 1800 mm x 450 mm ) comprising of the following electrical accessories fabricated from 50x50x6 mm MS angle frame and 16 SWG CRC Sheet power coated (Seven tank process) with necy. Welding incl painting with 2coats of Synthetic Enamel paint over 1 coat of RO primer( only for angle iron) as per GS. Base should be made of MS C Channel on suitable size. INCOMING:- S & F 415V 250 A TPN Switch disconnector fuse unit open execution type (L&T/Legrand/SIEMENS) with 3 Nos din type fuse link -- 02 no. CHANGE OVER:- S & F 415 V TPN on load Change over 400 Amp capacity open execution type (L&T/Legrand/SIEMENS)-1 no BUSBAR:- 500V Grade 4 nos ,600 Amp capacity tinned Copper bus bar of size 2 X 40x 5 mm,length 900 mm each having for Phase and N in Sheet metal box (16 SWG) with hinge type door with locking arrangement with telescopic screw - 1 set EARTHING:- 40x6 mm running earth bar with terminals at bottom side of the panel.
OUT GOING:- a) S & F 415V 125A TPN Switch disconnector fuse unit open execution type (L&T/Legrand/SIEMENS) with 3 Nos din type fuse link - 4 no. b) S & F 415V 63A TPN Switch disconnector fuse unit open execution type (L&T/Legrand/SIEMENS) with 3 Nos din type fuse link - 4 nos
CABLE ALLEY:- Cable alleys on both sides for out going connection are to be made incl. S & F suitable 12 nos of Brass Studs type connector on insulated chair having current carrying capacities as per the out going switches rating. Inter connection with the M S & Stud connectors is to be made with suitable size stranded copper wire as per the switch rating as specified in Interconnection.
INTERCONNECTION:- Inter connection is to be made same with 25 x 6 copper bar between 4 no 125 A main switch to busbar, 16sq mm stranded flex copper cable(Make-KEI) in between 4 nos 63A TPN SFU to busbar, & metering circuit with 1.5 sq mm single core stranded FR PVC copper wire with proper copper socketing & taping. Ferul connection and socketing is mandetory for every connection.
READING ARRANGEMENT:- a) S & F Multifunction Meter (Make-L &T Cat No-WL4410210000,/Legrand/SIEMENS) ---2 no b) 1000A/5A CT Coil ( Kappa Make) -- 3 nos c) LED type indicating lamp ( R Y B ) (Indicator plate is Mandetory for every SFU and Change over, busbar) -- 15 nos d)8:x6" size Danger Board --- 2 no. e) 6 Amp (Make Legrand/L&T/SIEMENS) SPMCB --- 3 nos
Installation of above mentioned panel on concreat flat base with all necessary arrangements as per direction of EIC. Making hallow brick wall foundation and brick soiling for installation of the cubical panel on that brick foundation incl. plastering and net cementing the wall and floor as per direction of EIC.
Distbn. wiring in 1.1 kV grade 2x1.5 sq.mm. single core stranded FR PVC insulated & unsheathed cu.wire (Finolex/KEI/Havells) in 20 mm dia PVC rigid conduit (Precision-M/polycab/AKG/Harsh) with 1x1.5 sq mm cu wire for ECC to light/fan/ call bell/exhaust fan pts.with moduler type switch (Havells coral/Crabtree/ Legrand) fixed on moduler GI.Box complete with cover plate and 3 Nos. cu.bar as per G.S..
Avg. run -12 mtr
Avg run -10 mtr
do -do- to 6A 3pin moduler type plug socket and 6A switch on 4 module GI switch board incl. interconnection. (on board)
S & F 240V,1 no. 6/16A Plug socket with 1 no.6/16A moduler type switch (Legrand/cabtree/havells) on wall incl.S&F 4 module GI box & cover plate incl.making necy.Connection by PVC cu wire as required.
S & F 240V,2 nos. 16A Plug socket with 2 nos.16A moduler type switch (Legrand/cabtree/havells) on wall incl.S&F 6 module GI box & cover plate incl.making necy.Connection by PVC cu wire as required.
S & F 240V,3 nos. 16A Plug socket with 3 nos.16A moduler type switch (Legrand/cabtree/havells) on wall incl.S&F 6 module GI box & cover plate incl.making necy.Connection by PVC cu wire as required.
Distribution wiring in 1.1 KV grade following single core stranded FR PVC insulated & unsheathed cu wire (Havells/KEI/Finolex)in 20 mm dia PVC rigid conduit (Precision/polycab/Harsh) incl necy fittings as reqd.
2x6+1x4 sq mm
2x4+1x2.5sqmm
2x2.5+1x1.5 sq mm
2x1.5+1x1.5 sq mm
Supply & Fixing of downlight 21/25 watt,240 volt AC,50Hz, having CCT 5700 K/4000 K, CRI >= 80 ,luminous efficacy=100 lumen per watt (minimum) and digital dimming capacity by DALI driver 25 watt for each luminaris,as per direction of EIC with 5 years replacement warranty. Make-, Havells ENDURA NEO DL REC RD 25 watt, or similar Make- Philips/Crompton.
SITC of DALI Ballast Dimming Actuator for atleast 90 nos LED based dimmer light (mandetorily digital actuator) with group or sub group or individual control (all these three facilities are needed), 2 pcs stage curtain control,phone and voice command scene control with intrigation of light and curtain (mainly used for cultural function mode/lecture mode/presentation mode), logic automation module used for timer based solution, suitable power supply module,advance DLP touch panel,panel power interface,3 module GI box, atleast 44 module GI Box,63 Amp four pole "C" series MCB (Legrand/Havells/ABB),TP+N type surge protector (Havells/Simens/ ABB),DP MCB, CAT 6 E LAN cable(as per location)(Polycab/Finolex) as per direction of EIC with 5 years replacement warranty. Make-Havells/Philips/Crompton.
S & F circular LED,35 watt(CDL/WW),240 volt, industrial luminaires having IP 66 protection suspended from ceiling with all accessories incl. interconnection as per direction of EIC (Crompton make cat no SUPRA I, LWV12-35-CDL-CPC/Phillips / Surya/Havells)
S&F 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board as to GS .
S&F 230V 400mm (16") Sweep heavy duty metal body wall bracket fan (Make : crompton/EPC/orient/havells) 1350 rpm silent in operation with S&F wooden base plate fixed on wall by 4 nos. steel fastener with nut, bolt & washer for fixing the wall bracket fan as per direction of EIC .
S&F 230v,1*20w single 4ft industrial box type luminaire with CRCA body with pre-coated in white & pre-wired for LED tube including 20w LED tube light with Aluminium Heat Sink body & inbuilt driver 20(Make-Crompton/Philips/Havells) on wall by 2 nos L-type M.S.clamp/wooden block,3 nos hole in each, M.S. fastner nuts & bolts etc.as per GS.
S&F 230v,2*20w twine 4 ft industrial box type luminaire with CRCA body with pre-coated in white & pre-wired for LED tube including 20w LED tube light with Aluminium Heat Sink body & inbuilt driver for LED tube (Make-Crompton/Philips/Havells) by L-type M.S.clamp,2 nos E.I conduit, M.S. fastner nuts & bolts etc.as per GS.
S & Fixing of 12 watt,240 volt, CDL/WW beam angle adjustable LED,round shape downlight with electronic driver with necessary inter connection and earthing attachment,as per GS and as per direction of EIC. (make- Havells-SPARKLEPROADJDLR12W830MOD40DWHTNEEM & LEDDRIVER15WS OR similer to philips or crompton)
S & Fixing of 18 watt,240 volt, CDL/WW slim LED,round shape downlight with electronic driver with necessary inter connection and earthing attachment,as per GS and as per direction of EIC. (make- Havells-EDGEPRORDDLR18WLED840S OR similer to philips or crompton)
S & Fixing of 3 watt LED inground light WW/ NW ,240 volt,50 HZ, IP 65 or 67 with suitable mounting box with electronic driver with necessary inter connection and earthing attachment,as per GS.(Make-Philips OR similer to Havells or crompton)
S & Fixing of 3 watt LED step light WW/ NW ,240 volt,50 HZ, IP 65 or 67 with suitable mounting box with electronic driver with necessary inter connection and earthing attachment,as per GS.(Make-Philips OR similer to Havells or crompton)
S & Fixing of 18 watt,240 volt, CDL/WW slim LED, square shape downlight with electronic driver with necessary inter connection and earthing attachment,as per GS and as per direction of EIC. (make- Havells-EDGEPROSQDLR18WLED840S OR similer to philips or crompton)
S & Fixing of 12 watt,240 volt, CDL/WW slim LED, round shape downlight with electronic driver with necessary inter connection and earthing attachment,as per GS and as per direction of EIC. (make- Havells-ENDURAHODLR12WLED840MOD OR similer to philips or crompton)
S & Fixing of 34 watt,240 volt, CDL/WW panel LED 2ft X 2 ft, square shape panel light with electronic driver with necessary inter connection and earthing attachment,as per GS and as per direction of EIC. (make- Havells-PLUTONEO2X2PLR34WLED857S OR similer to philips or crompton)
S & Fixing of 11 watt,240 volt, CDL mirror light with electronic driver with necessary inter connection and earthing attachment,as per GS and as per direction of EIC. (make- Havells OR similer to philips or crompton)
S & Fixing of 10 watt,240 volt, CDL bulkhead LED, light with electronic driver with necessary inter connection and earthing attachment,as per GS and as per direction of EIC. (make- Crompton-LBHP-10-CDL OR similer to philips or Havells)
S & Fixing of 18 watt,240 volt, CDL/WW intregated 4 ft LED batten light with electronic driver with necessary inter connection and earthing attachment,as per GS and as per direction of EIC. (make- Havells-LUMILINEPLUSBS20WLED865SPCSS OR similer to philips or crompton)
Supply and Fixing of LED operated (12" X 6") Transparent acryllic sheet made 'IN/OUT' board with engraved & aching letters and hanging facility by steel chain
Supply and fixing of 1 ft ,240 volt,5 or 6 watt,CDL/WW LED luminaire with electronic driver with necessary interconnection and earthing attachment as per GS and as per direction of EIC.(Make-crompton (LDL-05-CDL/WW or philips or Havells)
S&F 300mm(12") dia AC exhaust fan(Heavy duty) after cutting holes in the wall & mending good the damages by smooth cement finish incl. S&F louver shutter and making necy.Connections as reqd. (Make-EPC/Crompton/USHA)
S & Fixing of 18 watt,240 volt, CDL/WW round surface type LED, light with electronic driver with necessary inter connection and earthing attachment,as per GS and as per direction of EIC. (make- Havells-Endura Neo HeDL Surface OR similer to philips or Crompton)
Finishing the ends of the following cables & Cu wire by solderless socket, Tapes, anti corrosive paste. etc.
For 4 X 16 sqmm + 2 X 10 sq mm
For 2x6+1x4 Sqmm Cu Wire
2x4+1x2.5sqmm cu wire
For 2x2.5 +1x1.5 Sqmm Cu Wire
For 2x1.5+1x1.5 Sqmm Cu Wire
Supply and Fixing of LED operated (8" X 6") Transparent acryllic sheet made 'ENTRY' or 'EXIT' board with engraved & aching letters and hanging facility by steel chain
Supply and Fixing of 24 watt LED strip light of Different colour(as directed by EIC) with electronic driver which is highly suitable for cove lighting with minimum 20000 hrs long life.(Make-Philips/Havells/Crompton)
Supply and Fixing of 18 watt LED recess mounted round light of CDL/WW (as directed by EIC) with electronic driver with necessary inter connection and earthing attachment,as per GS and as per direction of EIC. .(Make-Philips/Havells/Crompton)
S & F of half round strong alluminium channel (3") on floor by suitable screw as per direction of EIC.
Painting Block Letters or Digits within a circle/square as required,with ”Black Japan” paint of approved make & brand, the size of letters and digits as given below Size of each letter-15 mm
S & F (Hot Dip) strips 25 mm x 6 mm thick for vertical run on wall for equipment earthing of Lift with existing post insulator spaced not exceeding 500 mm apart incl. mending good the damages to building work.
S & F (Hot Dip) strips 25 mm x 6 mm thick for parapet / roof/ horizontal run/ plinth surface on wall for equipment earthing of Lift with existing post insulator spaced not exceeding 500 mm apart incl. mending good the damages to building work.
Earthing with 50 mm dia GI pipe 3.64 mm thick X 3.04 mtr. Long and 1 x 25 x 6 mm GI (Hot Dip) strips(4mtr.) long 13 mm dia X.80mm long GI nut, bolt, Washer incl. S & F 30 mm dia GI/ HD PVC pipe protection (1 mtr.) long to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mtr. below the ground level.
Excavantion of soft soil for install. Of earth, electrode and filled incl. ramming the same properly.
S & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.(each 0.5 mtr)
Treatment of soil by using salt& charcoal or coke for pipe earthing
Hiring charges for scaffolding arrangement incl dismantling at the end of work and carriage for LC installation of vertical run.
S & F masonry inscription pit for earth station shall be approx 0.56 M x 0.56 M(1' - 10" x 1'-10") outside dimensions and approx 0.45 M(1'-6") deep when completed.Having 5"thick cement brick work with 1st class bricks in cement moetar (6:1) both inside and outside plastered 19 mm (3/4") thick both inside & outside and top shall be provided with R.C.C. cover fixed flush with ground surface. All the excavations shall be dully back filled, dressed and rammed.
S & laying 40 mm dia GI pipe protection in UG Trench, different drain for 25 mm x 6 mm GI Flat.
Making solderd joint between GI stripes and air terminal and other metallic objects incl. supplying of jointing materials with two nos 8 mm dia and 3/4 th length nut bolt of same matrerials with contact grease and painting with 2 coats of bituminous paint.
BHATTACHARYYA ENTERPRISE
ALPHA ELECTRICALS
INDIAN CON
Electromech Engineers Co-Operative Society Ltd.
RIDDHI (INDIA)
T.D.K. ENTERPRISE
Messrs HI- Q - ENTERPRISE
C. CHOWDHURY AND CO
stage.html
html • 0.07 MB
technical_572341.pdf
PDF • 0.56 MB
techsummary_572341.pdf
PDF • 0.56 MB
finance_572341.pdf
PDF • 0.56 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_572341.pdf
PDF • 0.44 MB
NIT_17_Lighting_Solution.pdf
PDF • 0.43 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .