Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC AT PO CHANDIPUR BALASORE 756025 | BALASORE | BALASORE | ODISHA | 756025 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹28.8 L+₹3.5 L (14.0%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹29.2 L+₹4.0 L (15.7%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹29.7 L+₹4.5 L (17.7%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | Rejected-Technical SHOPING COMPLEX CHANDIPUR BALASORE 756025 | BALESHWAR | ODISHA | 756025 | - | Rejected-Technical Not Approved by TIA |
Tender Value
₹23.2 L
EMD Value
₹46,400
Closing Date
17 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Chandipur
GE I R and D Chandipur, Post- Chandipur, PIN-756025
REPAIR MAINTENANCE OF CENTRAL AND PACKAGE TYPE AC PLANTS AT LAUNCHING AND TECH AREA OF ITR CHANDIPUR
2021_MES_415690_1
8605/CDP
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandipur
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
Yes
GE I R and D Chandipur
₹46,400
Yes
26 Mar 2021
23 Jan 2021
18 Feb 2021
23 Jan 2021
17 Feb 2021
11 Feb 2021
60 days
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.
M & L for dismantling and taking out unserviceable and defective parts of compressor of chiller Units of Central type AC Plants of capacity 30 TR VOLTAS make , Model No-M-65 after disconnecting the discharge & suction line removal of necessary electrical connection etc. Dismantling compressor body complete and carry out the repair work as per the following :- (a) Repairs to crank shaft, connecting rod, piston, piston pin valve plate by remetaling, cutting/grinding and polishing as required and by supply and replacing all spare parts with new one as required and directed. (b) Repairs /fixing by replacing of all new discharge and suction reeds, big end and small end bush, all bearing, all piston rings, capillary drier cum filter with new one all as specified and directed . (c) Repairs/fixing by replacing of all new kinds of gasket, washers, spring made of Nylon/ Tuflon sheet/ rubber/fibre sheet as required with new one and all as directed. (d) Repair of Oil pump kit by , dismantling and cleaning, greasing oiling along with new gasket all as required and directed. (e) M & L for Repair/replacement of old u/s copper pipe line as per existing size and shape when found leaking/damage at the time of leak check including necessary flairing, brazing as required and replacement of end fittings made of copper including brass flange nuts, brass dead cap and brass pipe as per site requirement and as directed.( Note : - The cost of new Copper pipe is also included in the same job ) (f) Supply and fix in repair of all u/s rusted bolts, nuts and washers of any kind/made of any metalical/any size and shape as per site requirement with new one all specified and directed. (Note :- The cost of all types/sizes of new nuts , bolts and washers are included in the same job. (g) After the repair work re-assembling the plant and check for leak in system with the help of Nitrogen gas. in case of any leak is detected the repair is to be carried out without any extra cost nitrogen/refrigerant gas. (h) After leak repair release Nitrogen and charge with refrigerant gas and testing to be carried out. Note : The cost for Nitrogen gas for Leak test, Charging/top up of Compressor oil and refrigerant gas (R-22) and necessery spares will be measured & Paid separately against ser Items No-2 to 13 and ser items No-22 to 26 of this schedule.
Supply only Suction reed as per existing make and model .
Supply only Discharge reed as per existing make and model.
Supply only Main Bearing as per existing make and model
Supply only Thrust Bearing as per existing make and model
Supply 0nly Piston Pin as per existing make and model.
Supply only Piston as per existing make and model.
Supply only Piston Ring as per existing make and model
Supply only Discharge and Suction Pin as per existing make and model.
Supply only Compressor oil ring
Supply only Supply Valve and Discharge Valve spring
Supply only unloader sleves as per existing make and model
Supply only Gasket Set as per existing make and model
M &L for Carrying out cleaning and de-scaling of iron deposited in condenser shell and tube and outside of the shell and tube of condenser by using chemical suitable for Descalling for the condensor unit of the compressor with the help of monoblock pump set , recommended by manufacturer manual of the respective plant by using suitable cleaning brush and others cleaning materials complete for Capacity 3x26TR Central type Scroll chiller AC Plant of Blue Star make at PP Buildings in ITR tech area ,and all as specified and directed by Engr - in charge.
All as per item no-14 here -in-before but Central type Ac plant of capacity 3x27.5 TR of ACCEL make at TIC (Knowledge Centre) Buildings in ITR Tech Area and all as specified and directed by Engr - in - Charge
All as per item no-14 here -in-before but Central type AC plants of capacity 3x40 TR of Carrier make at TTD Buildings in ITR tech area and all as specified and diredted by Engr - in chagre
All as per item no- 14 here -in-before but Central type AC Plants of capacity 3x 30 TR of VOLTAS make at AC Magzine Buildings in ITR Tech Area and all as specified and directed by Engr - in charge.
All as per item no-14 here -in-before but Central type AC Plants of capacity 3x35 TR of Carrier make at New MPO Buildings in ITR Tech area and all as specified and directed by Engr - in charge.
All as per item no-14 here -in-before but Central Type AC Plant of capacity 3x75 TR of Blue Star make at 06 Building in LC-III area ITR and all as specified and Directed by Enge - in charge.
All as per item no-14 here -in-before but Central Type AC Plant of capacity 3x90 TR of Blue Star make at Control Centre Building in ITR tech area , and all as specified and Directed by Enge - in charge.
All as per item no-14 here -in-before but Central Type AC Plant of capacity 2x70 TR of Blue Star make at RADAR Building in ITR Tech Area , and all as specified and Directed by Enge - in charge.
Pressure testing / leak arresting , vaccuming with dry nitrogen gas at the maximum pressure of 300 to 400 PSI / oil charging, incl replacing the unserviceable strainers all as required and testing complete for the Central type AC plant of capacity 25 to 40 TR Capacity at various locations/buildings of ITR tech area and LC area and all as specified and directed by Engr - in charge . Note :- (I) Refregerant Gas R-22/407/410/403 and strainers will be measured and paid seperately under suply only items (II) The Nitrigen gas pressure should be not less than 350 PSI during Leak arresting of the plants and it will hold the same pressure upto 24 hours and vaccum pressure should not be less then (-30 micron Pressure) during the Vaccuming of plants.
Pressure testing / leak arresting , vaccuming with dry nitrogen gas at the maximum pressure of 300 to 400 PSI / oil charging, incl replacing the unserviceable strainers all as required and testing complete for the Central type AC plant of capacity 50 to 90 TR Capacity at various locations/buildings of ITR tech area and LC area and all as specified and directed by Engr - in charge . Note :- (I) Refregerant Gas R-22/407/410/403 and strainers will be measured and paid seperately under suply only items (II) The Nitrigen gas pressure should be not less than 350 PSI during Leak arresting of the plants and it will hold the same pressure upto 24 hours and vaccum pressure should not be less then (-30 micron Pressure) during the Vaccuming of plants.
Pressure testing / leak arresting , vaccuming with dry nitrogen gas at the maximum pressure of 300 to 400 PSI / oil charging, incl replacing the unserviceable strainers all as required and testing complete for the Package type AC plant of capacity 5.5 TR to 16.5 TR at any location/building of ITR tech area and LC area and all as specified and directed by Engr - in charge . Note :- (I) Refregerant Gas R-22/407/410/403 and strainers will be measured and paid seperately under suply only items (II) The Nitrigen gas pressure should be not less then 350 PSI during Leak arresting of the plants and it will hold the same pressure upto 24 hours and vaccum pressure should not be less then (-30 micron Pressure) during the Vaccuming of plants.
Supply only for Recharge/Top up refrigerant R- 22 (Mefron) or equivalent in Central type AC Plants of various capacities complete all as directed .
Supply only for Recharge/Top up refrigerant R- 410/413/407C or equivalent in various type of Package/Central type AC Plants of various capacities complete all as directed .
Supply and charging/top up of Compressor Oil in various Central type AC plants, Suitable for existing central AC Plants Type : HPL-68 or equivalent as per existing sample (Make : SERVO/INDIAN OIL or equivalent as approved)
M&L for dismantling and overhauling of condenser/Chiller water pump set of capacity 15 HP, dismantling pump and motor separately, removing the burnt out winding from slots and rewinding the same by existing size and gauge of super enamalled copper wire including varnishing, heating, repairing the insulating materials, repalcing bearings, bushes and remetalling the shaft including and repairing the pump , including replacing the gland packing , bearings and all rusted nuts and bolts, washers and remetaling the Impeller of suitable size and bore for lifting the water from source and reassembling the motor and pump with gland packing includings painting of pump amd motor assembly complete with two coats of super enameled paints over one coats of red oxide, fixing the motor & pump at its position and connecting the suction and delivery water pipe and testing under working conditions, complete all as specified and directed.
All as per item No.28 here- in- before but of capacity 12.5 HP squirrel cage induction motor with pumpset of suitable capacity. (Make-Siemens/CG/Kirloskar/Beacon or any others make )
All as per item No.28 here- in- before but of capacity 10 HP squirrel cage induction motor with pumpset of suitable capacity. (Make-Siemens/CG/Kirloskar/Beacon or any others make
All as per item No.28 here- in- before but of capacity 7.5 HP squirrel cage induction motor with pumpset of suitable capacity. (Make-Siemens/CG/Kirloskar/Beacon or any others make
All as per item No.28 here- in- before but of capacity 5 HP squirrel cage induction motor with pumpset of suitable capacity. (Make-Siemens/CG/Kirloskar/Beacon or any others make
All as per item No.28 here- in- before but of capacity 3 HP squirrel cage induction motor with pumpset of suitable capacity. (Make-Siemens/CG/Kirloskar/Beacon or any others make
All as per item No.28 here- in- before but of capacity 1/1.5/2 HP squirrel cage induction motor with pumpset of suitable capacity. (Make-Siemens/CG/Kirloskar/Beacon or any others make
M&L for repair and servicing to squirrel cage induction motor 3 phase 415V, 12.5 HP Kirlosker make or any others make by dismantling of motor from the pump set removing the stater/rotor separately, cleaning, varnishing, heating and drying re-erecting, aligning with the pump, testing, including replacing the bearing and bush, polishing and re-metalling the shaft including necessary heat treatment. Reassembling the motor and pump with new gland packing, supply and fix new gland nuts, bolts, with gland mounting nuts & bolts washers complete , painting the motor and pumps with two coats of synthetic enamel paint after preparing the surfaces all as directed by Engineer-in-charge. fixing the motor & pump on their own base and connecting the suction and delivery water pipes and testing with proper working condition complete all as directed .
All as per item No 35 above but induction motor of capacity 10.0 HP with pumpset of suitable capacity.
All as per item No 35 above but induction motor capacity 7.5 HP with pumpset of suitable capacity.
All as per item No 35 above but induction motor capacity 5.0 HP with pumpset of suitable capacity.
All as per item No 35 above but induction motor capacity 3.0 HP with pumpset of suitable capacity.
All as per item No 35 above but induction motor capacity 2/1.5 HP with pumpset of suitable capacity.
Supply Fabricate and fixing of MS angle/MS plate/flat/rod for cooling tower frame, CT fan base, cooling tower ladders, and all supports made out of suitable size along with welding/MS nuts, bolts and washers, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted one ,all as specified and directed by Engineer-in-Charge
M&L for spray painting to complete chilled water type Central Air Conditioning plant of 3X30 TR capacity at AC Magazine Building, including complete chiller unit, compressor, motor, condenser refrigerant pipe, water pipe, chilled water pipe line, cooling tower, LT panel board complete plant with two coat of synthetic enamelled paint including preparation of surfaces and as per colour code all as specified and directed by Engineer - in - charge . Make :- Asian paint or any others equivalent paints
All as per item No. 42 above but for 3X 27.5 TR chiller type AC Plant at TIC (knowledge Centre) Building of ITR Chandipur
All as per item No. 42 above but for 3X 26 TR chiller type AC Plant at PP Building at ITR Chandipur.
All as per item No. 42 above but for 3X 90 TR chiller type AC Plant at Control centre at ITR Chandipur.
All as per item No. 42 above but for 2X 70 TR chiller type AC Plant at Control centre at ITR Chandipur.
S&F in repair power contactor of model no. 3 TS - 32 and capacity not less then 32 Amps and a coil voltage of 220 Volt along with NO and NC. (Make: Siemens / L&T or equivalent in others as per existing make and model.
S&F in repair power contactor of model no. 3 TS- 33 and capacity not less then 33 Amps and a coil voltage of 220 Volt along with NO and NC. (Make: Siemens / L&T or equivalent in others as per existing make and model.
S&F in repair Line monitoring Relay of model - 3T- 404-2A and all as per existing make and model for a coil voltage of 220 Volt along with NO and NC. (Make: Siemens / L&T or equivalent in others as per existing make and model.
S&F in repair power contactor model no. ML 3 for AC circuit with AC Coils voltage 220 Volt ,over load relay 10-25 Amps ( Cat No.- SS90721,and 2NO+2NC front mounted block. (Make- L&T or equivalent as approved)
S&F in repair electronic timer 3-30 sec ,5 A,24 volt AC (Cat No.HODT2COZ of GE or equivalent)
S&F in repair power contactor model no. MNX 25 for AC circuit with AC Coils voltage 220 Volt ,over load relay 25-45 Amps. (Make:Cat No.-CS94110 - L&T )
S&F in repair power contactor model no. ML 1.5 for AC circuit with AC Coils voltage 220 Volt ,over load relay 10-25 Amps (Cat No.- SS91851KOOO,and 2NO+2NC front mounted block. (Make- L&T or equivalent as approved )
S&F in repair of single phase preventer 40 Volts in balance VSP II.(Make-Minilec)
S&F in repair power contactor model no. MNX - 12E 4 pole 10 Amps for AC circuit with AC Coils voltage 220 Volt , Make L&T
S&F in repair power contactor model no. MNX-12 4 pole 10 Amps for AC circuit with AC Coils voltage 220 Volt , Make L&T
S&F in repair oil seal, O ring, carbon bushing of shaft of central Type AC Plants compressor of 27.5 TR capacity . (Make-ACCEL, model-SMC-8-65 or equivalent as approved)
All as per item No. 58 here in before but 30/35 TR capacity. ( Make-VOLTAS/ACCEL)
Supply and fixing in repair - MCCB 4 pole 250A 36 KA - in LT panel boards / feeder pillar boxes including disconnecting and removing existing from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement. Make all as specifed and as directed by Engr-in-charge.
Supply and fixing in repair - MCCB 3 pole 200A 36 KA - in LT panel boards / feeder pillar boxes including disconnecting and removing existing from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement. all as specifed and as directed by Engr-in-charge.
S&F MS pipe 200 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings including taking down old MS pipe for Central AC Plant (Make : Tata steel/Jindal steel)
S&F MS pipe 150 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings including taking down old MS pipe for Central AC Plant (Make : Tata steel/Jindal steel)
S&F MS pipe 100 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings including taking down old MS pipe for Central AC Plant (Make : Tata steel/Jindal steel)
S&F MS pipe 80 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings including taking down old MS pipe for Central AC Plant (Make : Tata steel/Jindal steel)
S&F Ratational moulded polyethene PVC tank of cap 2000 ltrs for use as makeup water tank for cooling Tower (cylendrecal vertical with closed top) hoisted and fixed in position of made on iron frame / faricated works incl fitting complete all as specified and directed at site.Make :- Sintex/
S&F in repair V Belt (A-52) for compressor motors ,CT fan motors, and blower motors (Make-FENNER/PALYP/Dunlop/Continental) or equivalent in others make
All as per Item No-67 above but for B-84 V belt.
All as per Item No.67 above but for B-86 V belt.
All as per Item No.67 here-in-before but for C-105 V belt.
All as per Item No.67 here-in-before but for SPA-1120 V belt.
All as per Item No.67 here-in-before but for B - 79 V belt.
All as per Item No.67 here-in-before but for B - 71 V belt.
Supply and fixing in repair AHU Filter as per sample suitable for Air handling Unit of Central AC Plant of capacity 3x27.5TR capacity of 53.34 cm x 46.99 cm x 5.08 cm as per existing make and model and all as specified and directed by Engr - in Charge.
Supply and fixing in repair AHU Filter as per sample suitable for Air handling Unit of Central AC Plant of capacity 3x27.5TR capacity of size 60cm x 60cm x 4.5cm as per existing make and model and all as specified and directed by Engr - in Charge.
S&F in repair butterfly valve of 200 mm dia valve PN-1 with ISI marked including gasket, nut bolts . (Make : Upadhaya/ Kirloskar or any others equivalent
S&F in repair butterfly valve of 150 mm dia valve PN-1 with ISI marked including gasket, nut bolts . (Make : Upadhaya/ Kirloskar or any others equivalent
S&F in repair non Returning Valve of 100 mm dia valve PN-1.6 with ISI marked including gasket, nut bolts washers and connected accessories for proper fixing and all as sopecified and directed by Engr - in charge . (Make : Upadhaya/ Kirloskar or any others equivalent
S&F in repair butterfly valve of 65 mm dia valve PN-1.6 with ISI marked spindle including gasket, nut bolts . (Make : Upadhaya/ Kirloskar or any others equivalent
S&F in repair entering water temperature(EWT) sensor suitable for 26 TR/30TR scroll type AC Plant.(Make: Blue star and Voltas as per existing model ).
S&F in repair leaving water temperature(LWT) sensor suitable for 26TR/30 TR scroll type AC Plant.(Make: Blue star and Voltas as per exixting model).
Supply and fixing of of PVC Fills of size (600x300x150mm), blue colour, sutable for any type of cooling tower of central air conditioning plant
S&F in repair Safety valve 300 PSI of copper material suitable for 25 TR t0 90 TR capacity Central/package type AC plant( as per existing make and model)
S&F in repair thermometer 0-06 suitable for 25 TR t0 90 TR capacity Central/package type AC plant( as per existing make and model)
S&F in repair Pressure gauge of maximum 20 Kg/Cm2 of pressure suitable for 25 TR t0 90 TR capacity Central/package type AC plant( as per existing make and model)
Supply and fix in repairs LED indication Lamps for R,Y,B Phase Make : Suman Electric or equivalent in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model.
Supply and fix in repairs Push Button Switches (Red and Green, in Colour) Make : Suman Electric or equivalent in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model.
Supply and fix in repairs Ammemeter analog type range above 100A below 300A Make : Suman Electric or equivalent in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model.
Supply and fix in repairs Voltmeter Analog type range upto 600Volts Make : Suman Electric or equivalent in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model.
Servicing and Maintenance including minor repairs and making in serviceable condition of the package type AC Plants of 5.5/7.5/11.0/16.5 TR capacity comprising of all minor parts and machineries including charging of R - 410/407/22 Gas and when ever required repair and maint of compressor and blower motor Air filters de-humidifying coils lt control pannels , PCB, ducts and accessories of all gauges and meters and keeping in perfect working condution all as specified and directed by the Engr-in-charge .Note : Leak test,refrigerant Gas will be measured and paid seperately under relevent items of schudle if any required .
S&F in repair three phase Control PCB for package type AC plant of 5.5 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair three phase Control PCB for package type AC plant of 7.5 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair three phase Control PCB for package type AC plant of11.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair three phase Control PCB for package type AC plant of16.0 TR Capacity, (suitable for Blue Star Make) , all as specified and directed by Engr - in - Charge.
S&F in repair Air sensor for package type AC plant of 5.5/7.5/11.0 TR Capacity, (suitable for Blue Star and volras Make) , all as specified and directed by Engr - in - Charge.
S&F in repair Coil sensor for package type AC plant of 5.5/7.5/11.0 TR Capacity, (suitable for Blue Star and Voltas Make) , all as specified and directed by Engr - in - Charge.
Supply and fixing in repair 4 Core 10 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for connection of package/central type AC plant.
Supply and fixing in repair MCB TPN 63 Amps for connection of package/central type AC plant as main incommer
Supply and fixing in repair MCB TPN 40 Amps for connection of package/central type AC plant.
Supply and fixing, V belt of suitable sizes for 5.5TR capacity Package type AC plant blower motor . Make : FENNER/Dunlop
Supply and fixing for V belt of suitable sizes for 7.5 TR blower motor Make : FENNER/Dunlop
Supply and fixing for V belt of suitable sizes for 11.0 TR blower motor Make : FENNER/Dunlop/continental
Supply and fixing for V belt of suitable sizes for 16.5 TR blower motor Make : FENNER/Dunlop
S&F in repair of refillable type drier filter suitable for Central type AC Plant of capacity 26/27.5 /30/35 TR capacity. (Make: Voltas/carrier/Accel)
Supply and fixing in repair , Compressor of capacity 7.5 TR capacity suitable for Package type AC Plants including taking down existing one and all as specified and directed by Engr - in Charge.
M & L for replacement of U/S Canvas cloths heavy duty of package/centraltype AC plants and properlly fasterners with suitable size bolts and nuts and washers between the ducts and dumpers of the plants and all as directed by the Eng-in-charge
Supply and fixing Flow swithch 25 mm dia suitable for 26 TR central AC plant all as specified and directed by engr in charge .
Supply and fixing GI tubing medium grade 40 mm bore with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple etc and all as required at site.
Supply and fixing GI tubing medium grade 25 mm bore with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple etc and all as required at site.
Supply and fixing GI tubing medium grade 20 mm bore with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple etc and all as required at site.
S&F in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of sizes 40 mm bore including taking down the unserviceable existing ones.
S&F in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of sizes 25 mm bore including taking down the unserviceable existing ones.
S&F in repairs gun metal gate valve ISI marked with iron wheel head, screwed both ends for iron pipe of sizes 20 mm bore including taking down the unserviceable existing ones.
Supply and fix in repair PVC Ball valve ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed for 40mm bore (minimum wt 690 gms). Make :- Prayag ISI marked High Pressure (HP)
Supply and fix in repair PVC Ball valve ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed for 25mm bore (minimum wt 455 gms). Make :- Prayag ISI marked High Pressure (HP)
Supply and fix in repair PVC Ball valve ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed for 20mm bore (minimum wt 210 gms). Make :- Prayag ISI marked High Pressure (HP)
jlenterprise
KRISHNA ENTERPRISES
M/s R.C REFRIGERATION
Bidder Name
DS ENTERPRISES
KRISHNA ENTERPRISES
M/s R.C REFRIGERATION
jlenterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .