Driller-in-Charge. BMSD(D)
Office of the Driller-in-Charge. Bankura Mechanical Sub-Division (Drilling). P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102
Rectification of L.T. MCC CUM PDB Panel at Belatikri Water Supply Scheme, Block-Sarenga under Bankura Mechanical Division, P.H.E. Dte.
2026_PHED_5073822_3
WBPHED/BMSD(D)/NIeT- 01 OF 2026-2027
Open Tender
Electrical Work/ Equipment
Item Rate
20 days
Ailakundi
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,000
Yes
24 Sept 2026
24 Sept 2026
7 Oct 2026
24 Sept 2026
5 Oct 2026
24 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Fault Finding of L.T PDB cum MCC panel (630Amp incommer Switchgear, 4nos 75kw Stardelta Starters Capacitors bank and other items by the engaiging skilled electrician from panel manufaturer including transportation lodging fooding charges at Site as per direction of EIC | 1 | LS | -148 | - |
| 2 | Dismantling and takenout of Existing (defective one ), with its cables, Nuts & Bolts, cleaning of SPD flashing unit, cleaning of PLC chamber, cleaning of PLC chamber, cleaning of relay flashing in CT Feeder, Incomer portion the space making necessary arrangements for fitment of supplied items with supplying CTC etc as per direction of EIC | 1 | L.S | -147 | - |
| 3Supply delivery of following items | |||||
| 3.01 | Digital type Cl 0.5, LCD display, Restricted Multifunctioning meter, RS-485 Power and energy: measurement, display and recording of three power and corresponding energy parameters simultaneously in W/Wh, VA/ VAh and VAR/ VARh.
Model- METSEEM6436HCL10RS for SCHNEIDER Make. | 1 | Each | -145 | - |
| 3.02 | Microprocessor Based Analog type ECOR with display EOCR-SSD- (0-30)Amp
Model- EOCRSSD-30S (3-30)A, 24-240v AC/DC, with display, Make: Schneider | 9 | Each | -144 | - |
| 3.03 | Digital EOCR Without Communication
Current Range- 0.5A-80A
Control Voltage- 100VAC-220VAC
Without Ground Fault Protection, Window Hole
Microprocessor Based EOCR-3DM2- 0-80A
Model- 3DM2-WRDUWZ (100~240V Window connection)
Make: SCHNEIDER | 2 | Each | -143 | - |
| 3.04 | Over Voltage/Under Voltage Relay, Supply Voltage: 240 VAC (Nominal), 3 Phase (4-Wire) or 1 Phase, DPDT - Double Pole Double Throw, Time Delay (ON): Selectable 0.5 to 15 seconds, Protection Features: Under Voltage (UV), Over Voltage (OV), Single Phasing Preventor (SPP - Phase Loss), Phase Sequence, and Neutral Loss, 5 A at 250 VAC / 28 VDC, Power Consumption: 5 VA (Max.)
Model- MG73BH, Make: GIC | 1 | Each | -142 | - |
| 3.05 | TPN SPD Unit, 40KA, Type-2 (Class II) AC Surge Protection Device, 3P+N (Three Phase + Neutral), Rated Operational Voltage: 400V / 440V AC, Protection/Safety Rating: IP20, Operating Temperature: -40°C to +85°C, Maximum Discharge Current: 40kA (8/20 µs) waveform, [AU SPD (Type 2) – 4 Pole40kA]
Model- AUSP023PN40D, Make: LK | 1 | Each | -141 | - |
| 3.06 | Analog AC Ammeter, Size- 96 mm X 96 mm, Moving Iron (MI) / Ferromagnetic, CT-Operated (../5A or ../1A secondary), Operational Temperature: -10°C - +55°C, Make: AE | 1 | Each | -140 | - |
| 3.07 | Red Lamps, Green Lamps, Yellow Lamps, Rated voltage 230 V AC, 50/60Hz, Temperature- −25°C to +65°C
Model- EPLR240A, EPLG240A, EPLY240A, Make: ESBEE | 4 | Each | -139 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 28.02 MB
Tendernotice_2.pdf
PDF • 1.11 MB
BOQ_5162050.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .