Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC | ₹2.5 Cr | L1 | Accepted-AOC L-1 |
| 2 | L2₹2.5 Cr+₹7,713.33 (0.03%)Rejected-Finance | ₹2.5 Cr+₹7,713.33 (0.03%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical CHAIBASA | SARAIKELA KHARSAWAN | JHARKHAND | 831013 | - | - | Rejected-Technical Non Responsive |
| Sl No | Description | Qty | Unit | Ms Gokul Construction L2 | Sutanu Kumar L1 |
|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I. | 238.11 | Cum | 151.82 ₹36,149.86 Lowest | 151.82 ₹36,149.86 Lowest |
| 2.00 | Extra for earthwok in hard soil as per specification and direction of E/I. (Vide classification of soil item - B). | 154.77 | Cum | 15.51 ₹2,400.48 Lowest | 15.51 ₹2,400.48 Lowest |
| 3.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) | 34.81 | Cum | 589.51 ₹20,520.84 Lowest | 589.51 ₹20,520.84 Lowest |
| 4.00 | Providing designation 75B one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. | 319.41 | Sqm | 330.34 ₹1,05,513.9 Lowest | 330.34 ₹1,05,513.9 Lowest |
| 5.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level -1:2:4 (1 Cement : 2 coase sand ( zone-III) : 4 graded stone aggregate 20 mm nominal size) | 34.33 | Cum | 4,598.23 ₹1,57,857.24 Lowest | 4,598.23 ₹1,57,857.24 Lowest |
| 6.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) | 37.41 | Cum | 5,218 ₹1,95,205.38 Lowest | 5,218 ₹1,95,205.38 Lowest |
| 7.00 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. | 37.3 | Cum | 5,110.26 ₹1,90,612.7 Lowest | 5,110.26 ₹1,90,612.7 Lowest |
| 8.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) | 17.58 | Cum | 6,082.45 ₹1,06,929.47 Lowest | 6,082.45 ₹1,06,929.47 Lowest |
| 9.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | 4.06 | Cum | 6,308.87 ₹25,614.01 Lowest | 6,308.87 ₹25,614.01 Lowest |
| 10.00 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. | 69.25 | Cum | 5,244.08 ₹3,63,152.54 Lowest | 5,244.08 ₹3,63,152.54 Lowest |
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
6 Oct 2025, 11:00 amClosed
E.E. BCD, Building Division No.-1, Ranchi
E.E. BCD, Building Division No.-1, Ranchi
Construction of Multipurpose Hall Using PEB (Pre-Engineered Building) at RDC, SDO Residence, Kanke Road, Ranchi
2025_BCD_105155_1
BCD/Div.No.-1, Ranchi/38/ 2025-26
Open Tender
Civil Works - Buildings
Works
90 days
Ranchi
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹5.0 L
Yes
27 Jan 2026
25 Sept 2025
7 Oct 2025
25 Sept 2025
6 Oct 2025
25 Sept 2025
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
Extra for earthwok in hard soil as per specification and direction of E/I. (Vide classification of soil item - B).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
Providing designation 75B one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level -1:2:4 (1 Cement : 2 coase sand ( zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
12mm to 16mm
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with M.S hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/ window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variationin profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Frame size 65 x 100 mm
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 , of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 1200 mm
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I.
Providing and fixing of external wall system on Light gauge steel frame work with outer face cement boards as per standard sizes fixed with self- drilling / taping screws / fasteners @ 60cm c/c of approved make. A groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. The board shall be fixed in a staggered pattern. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. Internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with selfdrilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. (cost of frame work to be paid for separately) Outer face- Outer face having 6mm thick fiber cement board Type A, Category-IV as per IS:14862:2000 fixed on 9mm thick fiber cement board, Type A, Category-IV as per IS:14862:2000 (high pressure steam cured) Inner Face-12.5 mm thick gypsum plaster board conforming to IS 2095:2011 fixed on 8 mm thick fibre cement board of Type B, Category-Ill conforming to IS:14862:2000 (High pressure steam cured)
Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge.
Carriage of Material
Sand Lead 8 Km
Stone Chips Lead 22 Km
Bricks Lead 8Km (1K+7K)
Point wiring in PVC conduit with modular type switch:- Wiring for light point /fan point /exhaust fan point /call point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch ,modular plate, suitable size G.I. box etc.as required. Group B
Twin control point wiring in PVC conduit with modular type switch:- Wiring for twin control light point witch 1.5sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC CONDUIT, 2 way modular, type switch, modular plate, suitable size G.I. box etc .as riquied.
power plug wiring in PVC conduit(2x4sq.mm):-wiringfor light power with 2x4 sq mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit along with 1 Nos. 4 sq. mm FR PVC insulated copper conductor singl core cable for loop earthing as requied.
Circuit/submain wiring in PVC conduit:- Wiring for circuit/submain wiring along with earth with following sizeg PVCinsulated copper conductor,single core cable in surface/recessed PVC conduit as requied.
2x1.5sq mm+ 1x1.5sq mm earth wire
2x2.5sq.mm+1x2.5sq.mm earth wire
2x6.0sq.mm+1x6.0sq.mm earth wire
4x10sq.mm+2x10sq.mm earth wier
TV cable in existing conduit:- Supplying and drawing co-axial TV cable RG-6 grade copper conductore ,PE insulated,with PVC sheath in the existing surface/recessed PVC conduit as required.
S/F PVC conduit:- Supplying and fixing of following sizes PVC counditalong with accessories in surface/recess in including cutting the wall and making good the same in case recessed conduit as required.25mm
S/F Modular type switch/socket:- Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including modular plate us required.
5/6amps,one way switch
15/16 amps, one way switch
5/6 amps,3 pin socket outlet
15/16 amps, 6 pin socket outlet
Tvantenna socket outlet
S/F modular type electronic fan regulator :- sfpplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc,as required.
S/F modular type blanking plate :- supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required.
S/F modular boxes ,base & cover plate :- supplying and fixing following size/ modules G.I. box along with modular base & cover plate for modular switches in recess etc as required
1 or 2 module (78mmx78mmx45mm)
6 module (78mmx205mmx50mm)
S/F light plug point with type accessories :-supplying and fixing suitable size G.I. box with moudular plate and cover in front on surfesh or in recess including providing and fixing 3 pin, 5/6 mps moudular socket outlet and 5/6 mps modular type switch connection, painting etc. us rquoired. (for li
S/F light plug point with type accessories :-supplying and fixing suitable size G.I. box with moudular plate and cover in front on surfesh or in recess including providing and fixing 6 pin, 15/16 mps moudular socket outlet and 15/16 mps modular type switch connection, painting etc. us rquoired.
S/F ceiling roase:- suppliying and fixing 2 pin mps. Ceiling roase on the existing juction box/woon bolck including connection etc. as required
S/F batten holder:- supplying and fixing batten/ angle holder incuding connection etc as required.
ITC ceiling fan:- Installtion, testing and sonnissoning of ceiling, including wiring the down rods of standard length (op to 30cm) with 1.5 sq.mm FR PVC insulated. Copper conducotr, single core cable etc. as required.
ITC exhaust fan upto 450 mm. swee:- Installation of exhaust fan op to 450 mm. sweep in the existing opening, including making the hole to suit the size of the above commissioning etc as required.
S/F s.p. MCB DB:supplying and fixing following way single pole neutral sheet,MCBdistribution board,240 volts,on surface/recess,completewith tinned copper busbar,neutral busbar,earth bar,din bar, detachable gland plate,interconnection,phosphatized and powder painted including earthing etc asrequierd.(But without MCB/RCCB/lsolator)
12way Double door
16way Double door
S/F s.p. MCB DB:supplying and fixing following way three pole neutral sheet,MCBdistribution board,415volts,on surface/recess,completewith tinned copper busbar,neutral busbar,earth bar,din bar, detachable gland plate,interconnection,phosphatized and powder painted including earthing etc asrequierd.(But without MCB/RCCB/lsolator)
6way(4+18),Double door,Horizontal type
8way(4+24),Double door,Horizontal type
S/F 'c' series, S.P. MCB:-Supplying and fixing following, ,240 volts,'c' series,miniature circuut breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections,testing and commissioning etc.asrequied.
6/32amps, single pole
40amps, DP
50/63 amps,TPN
S/F SP MCB blanking:- supplying and fixing single pole blanking plate in existing MCB DB complete etc.as required.
S/F SPN RCCB:- supplying and fixing following rating,double pole (single phase and neutral)240 volts,residualcurrent circuit breaker (RCCB),having asensitivity current upto300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc.as required.63amps
S/F 20amps SPN MCB industrial socket outlet:- supplying and fixing 20amps,240 volts,SPN industrial type,socketoutlet,with 2pole and earth,metal enclosed plug top along with 20amps 'c' series,SP MCCB,in sheetsteel enclosuer,on surface or in recess with chainedmetal cover for the socket outletand complete with connections,testing and commissioning etc.as required.
P/F M.V.danger notice plate:- providing and fixing M.V danger noticeplate of 200mmx150mm,made of mild steet,at least 2mm thick, and vitreous enamelled with on both sides,and with inscrition in single red colour on front side as required.
G.I. Earth pipe eletrode with salt/charcoal:-Erthing with G.I erth pipe 4.5 mtr long,40mm dia inculuding accessories,and providing masonare enclosure with cover plate having locking arrangment and watering pipe etc.with charcoal and salt as required.
S/L 6 SWG G.I. wire in ground:- Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor erthelectrode,including soldering etc.as required.
P/F lighting conductor finial:- providing and fixing of lighting conductor finl,made of 25mm dia 300mm long, G.I. tube, having single prong at top,with 85mm dia 3mm thick G.I. base plate including holes etc .complete as required.
Reverting, sweating and soldering lightning conductor tape:- Revertng, sweating and soldering and copper/G.I. tape (with another copper/ G.I. tape,base of the finial or any other metallic object) as required.
P/F G.I. lighting conductor tape in horizontal run:-providing and fixing G.I. tape 20mmx3mm thick on parapet or surface of wall for lightning condctor complete as required.(for horizontal run)
P/F G.I. lighting conductor tape in vertical run:-providing and fixing G.I. tape 20mmx3mm thick on parapet or surface of wall for lightning condctor complete as required.(fo vertical run)
P/F Testing joint for G.I. lightning condctor:- providing and fixing testing joint, made of 20mmx3mm thick G.I strip, 125mm long, with 4 nose. Of G.I. bolts, nuts. Check nuts and spring washers etc complelte as requied.
MV cable laying upto 25 sq.mm.in ground:- laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV garde of size not exceeding 25sq.mm direct in ground including excavation,sand cushioning,protective covering and refilling the trench etc as required.
Supply, installation, testing and commissioning of of following size ceiling fan 3 blades confirming to IS:- 374:2019 including wiring tne down rods, of standard length (up to 30 cm) with 1,5 FR PVC insulated, copper wire suitable for 230 Volts, 50 Hz, single phase supply etc. complete as required.( BLDC 5 Star (32 Watt) IS:374:2019 (energy efficient fans and two yeas warranty ) (Make & Model nos. of Fans are to be approved by Engineering Incharge & Consultant before procurement.)
Supply of 48" (1200 mm) Sweep Ceiling fan BLDC 5 Star (32 Watt) IS:374:2019 (energy efficient fan. Make :Usha/Crompton/ Havells/GEC.
SITC of 230 mm (9") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :- Polar/Usha/Crompton / Havells.
SITC of following rating recess/surface mounted LED round/square shape Down Light Luminarie with pressure die-cast housing for single phase supply voltage. Luminarie shall be confirm to IS; 10322 part-5/section-2 or IEC 62722 with all necessary accesoreies as required. (100l/w , 5700K Cool white, rated voltage- 220/240V. (LM 79 and LM 80 reports need to be submitted , 50,000 burning hrs, and two years warranty) Make:-Havells/Philips/Bajaj/ Jaquar. Make 0f LED Philips/Osram/Cree/Nichia.
12 W Round Surface Down light
15/16 W Round Surface Down light
Recess Mounting LED Panel [ght 2x2 (36W)
15W COB based round LED light with multiple bem angles (36 Degree)
30W COB based round LED light with multiple bem angles (36 Degree)
SITC of following rating surface mounted LED 4ft Batten tube light fitting suitable for 230V, 50 Hz, single phase supply etc all complete as required. wall mounted LED type batten fitting complete with electronic diver and LED etc. directly on wall including connections with 1.5 Sq. mm FR PVC insulatted copper conductor and earthing the body etc. as requiered. (LM 79 and LM 80 reports need to be submitted , 50,000 burning hrs, and two years warranty) Make:-Havells/Philip/ Wipro/ Jaquar
20/22 W LED Tube Light (4 FT) Batten type.
SITC of LED 2 ft Mirror light with power 8/10W, rated voltage 230W, 50 HZ, aluminium /PC body with running life minimum 30000 hrs. ( LM 79 and LM 80 reports need to be submitted)
Supplying and fixing Surface mounted 9/10 Watt CFL / LED type bulk head e comprising of pressure die casr housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc. directly on wall /ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc as required.
SITC of 4 to 6Watt LED Foot Lamp/LED Step Light cast alluminium body and IP-54, protection
Building Outer Light (45/48W LED) :-Supply, fitting, fixing and testing of building outer lighting luminaire aerodynamically shaped single piece pressure die-cast Aluminum luminaire with high power LEDs as light source and electronic driver (IP65), along with 45/48W LED Lamp, as Energy saving as per drawing prescribed reflector and heat resistant toughened flat glass cover, with 5ft long 40mm dia G.I. pipe with 3 Nos. of iron clamps , anchor nut bolts with double washers as per direction of E/I or consultant as per drawing prescribed reflector and heat resistant toughened flat glass cover (IP-65) and in compliance to IEC Safety Standards. LM 79 and LM 80 reports to be submitted with all accessories. Make:- Havells/Philips- Signify/Bajaj/Jaquar Make 0f LED :- Philips/Osram/Cree/Nichia.
Supply fitting and fixing of PVC/XLPE insulated PVC sheathed heavy duty Al. armoured cable for workingvoltage up to and including1100 Volts confirming to IS 1554 (part-1)Make:- Havells, KEI, Finolex, Polycab.
3.5 Core 25 Sq. mm
3.5 Core 120 Sq. mm
1.1 KV Cable End Termination:-Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required.
3.5 Core 25 Sq. mm. (28mm)
3.5 Core 120 Sq. mm. (45mm)
2.0Tr. 5 Star Split A.C (Inverter Type) IS-1391-part-I
Copper Tube of size 1/4" for aplit ac unit 1/1.5/2/3 Tr capacity including nitride rubber
Copper Tube of size 5/8" for aplit ac unit 1/1.5/2/3 Tr capacity including nitride rubber
5 KVA wall mounted automatic voltage stablizer from range 140V to 280V
Drain Pipe For AC
Outdoor stand for 2.0 Tr Split AC
Installation of PEB (Pre Engineering Building) including design, supply, transportation with erection and finishing excluding wall cladding and civil works -Constructing and framing of steel line with front end and back-end frame as non-expandable rigid frame and Bracing on Roof with Rod/Angle bracing for roof and one side wall. Anchor bolts shall confirm to the physical specification of ASTM A 36M / IS 2062 and having a minimum yield strength of 245 MPa. Roof panels shall be 0.47mm (TCT)(AZ150/70) & 0.50mm (TCT)(AZ150/70) thick profiled bare galvalume or colour coated galvalume steel sheeting respectively. It can be shipped in any length up to 12m. Colour of exterior and interior faces shall be white/grey. Other materials, thicknesses and coating are available upon request. The material shall conform to ASTM A792 and the galvalume coating to ASTM-A792- AZ150. The minimum yield strength of material shall be 550 MPa. For Eave Gutters and Downspouts: Valley Gutter shall be cold rolled from galvanized steel and it shall confirm to the physical specification of IS 513 Grade ‘O’ or Grade ‘D’ and having a minimum yield strength of 240 MPa. Eave Height (m) should be of 6m and Eave gutters shall be box shaped, colour coated, and 0.5mm nominal thickness (26gauge) steel. The outside face of the gutter shall be supported with colour coated 0.5 mm nominal thickness (26 gauges) straps to the eave member at a maximum spacing of 1.2m. The Flashing, Trims, Eave gutters and Down Spouts Pipe is considered in Colour Coated Galvalume. Sheet fasteners All sheeting fasteners are self-tapping metal screws with metal and neoprene washers. All screws shall have hexagonal heads, and made of zinc plated steel. These are specially designed screws in small, medium and large sizes. (HP Make) Flashing and trimming: Flashing and/or trim shall be furnished at the rake, corners, and eaves, framed openings and wherever necessary to provide weather tightness and finished appearance. Colour shall be white for rake and eave flashings as specified by client from one of our standard ranges of colour. Material shall be 26G thick conforming to the physical specifications of ASTM A446 Grade C or equivalent and having minimum yield strength of 50,000 P.S.I. (550 MPa). High Strength bolts shall confirm to physical specification of ASTM A 325M Class 8.8 Type 1 or its equivalent Electro Galvanized to ASTM A 153M Class C and having a minimum yield strength of 830 MPa M.S. Bolts shall confirm to physical specification of ASTM A 307 / IS 1367 Grade 4.6 / 4.8 Type 1. Hot dip Galvanized having minimum yield strength of 400 MPa. Surface Paint Preparation for Structure shall be of Colour Enamel paint on all structure (Berger/Asian) on red oxide primer with sort blasting considered The finishing of all structural members should be done by cleaning them by wire brushing to remove dirt, grease, oil and loose mill scale and given one shop coat of red oxide, air drying, and phenol modified alkyd resin primer / grey primer. Any additional finish painting is not included in scope of supply. Two coats of synthetic enamel paint would be applied at site at the time of Erection. For Roof Sheeting Roof cladding shall conform to the physical specifications AZ 70/150 and having a strength of 550 MPa , Roof Slope 1:10 with Cage ladder (01 nos. for roof access considered) Hi- Rib Profile Sheet should be Bare Galvalume with thickness of 100 MM- Puff Panel Green and sheet Colour Coated – Red and Thickness 0.50 mm. Sky Light Panel roof of Polycarbonate Sheet 2mm and Turbo-vents 600 mm. The design load on the roof should be Dead Load (0.15 KN/m2) and Live Load(0.57 KN/m2) with wind speeds of 39 m/sec, in accordance with as per IS 875 The design building code should conform to the welding code as per AWS. All loads should be applied as per 1996 edition of Low-Rise building Systems Manual by Metal Building Manufacturer's Association (MBMA). All manufacturing dimensional tolerances are in accordance with the requirements of 1996 edition of Low-Rise building Systems Manual by Metal Building Manufacturer's Association (MBMA). The deflection limit is set at Main Frame Vertical (L/180), Main Frame Lateral (EH/100) and Purlins(L/180). The minimum Cold form Thickness Is 1.5 MM & Built-Up Is 5.0 MM.For primary and secondary members: The primary structural framing shall include the transverse rigid frames, lean-to-rafters and columns, interior columns (beam and column frames), bearing frame rafters and corner columns and enwall wind columns. Secondary structural framing including the purlins, girts, eave struts, wind bracing, flange bracing, base angles, clips and other miscellaneous structural members. The specification of structural members should be as follows- Members fabricated from plate or bar stock shall have flanges and webs joined on one side of the web by a continuous welding process and will conform to the physical specifications of ASTM A572 M (Grade 50) Type 1 or equivalent and having min. yield strength of 250/345 MPa. Members fabricated by cold forming process for black steel it shall conform to the physical specifications of ASTM A570 M (Grade 50) or equivalent and having minimum yield strength of 250 MPa; for Galvanized steel it shall conform to the physical specifications of ASTM A653 M SS Grade 340 Class 1, 120 gsm or equivalent and having minimum yield strength of 250 MPa. Members fabricated from hot rolled structural shapes for Beams, Channels & Columns shall conform to the physical specifications of IS 2062 / 1999 Grade B or equivalent having a min. yield strength of 245 MPa; for Tubes it shall conform to the physical specifications of IS-4923 or equivalent having a min. yield strength of 345 MPa; for pipes/ hand rails it shall conform to the physical specifications of IS 1161 – 1979 or equivalent having a min. yield strength of 245 MPa. Area As per Cad Drawing and Manufacturer provided Drawing Rod and angle bracing shall conform to the physical specifications of ASTM A 36 / IS 2062 (or equivalent) and having a minimum yield strength of 245 MPa.
Design,Providing, installation and fixing 12 mm thick Toughened Glass (Glass Make:- Saint Gobain/ Asahi glass India) DOORS upto 2.4 M with all as per required arrangement & proper machine edge finish in angle & fixed in the flooring side with Aluminium 'U' channel . Glass panels to be formed as per approved modules 12 mm thick clear toughened glass edge polished and accurate designed holes to be installed by means of steel fittings of an approved make Saint Gobain / Asahi or equivalent. Including Floor spring (make:- Dorma or equivalent), Lock approved make, Door Handle both side(SS make), all works including labour, wastages, cost of scaffolding, finishing with frosted design film etc. complete.
Providing and fixing Kalinga Stone Marble Flooring 15 mm thick, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.
Supply & Installation of Aliminium system window Make Bari,Cardina lor Equivavalent as per direction of EI Specification as below Frame Construction Depth: 50mm Locking System: Single Point/Multipoint Glass Range: 8 mm Corner Details: 45 degree cut, joint with corner connector Sealing Overlap: 6mm (Sealing with Gasket) Window Height (Max.): 2100mm Window Width (Max.): 1200 mm Finishes: Wood Alloy: 6063 T6 Hardware: BAARI
Providing and fixing PVC Pannel False Ceilling which includes providing and fixing Gl perimeter channels of size 0.55 mm. Thick having one flange of 20 mm and another flange of 30 mm and web of 27 mm along the perimeter of the ceiling, screw fixed to brick wall/ partition with help of nylon sieves and screws, at 610 mm centres. The suspended Gl intermediate channels of size 45 mm.0.9mm thk with two flanges of 15 mm each from the soffit at 1220 mm centres with ceiling angles with ceiling angle of width 25mm x 10mm x 0.55mm thk fixed to soffit with Gl cleat and steel expansion fasteners.
Providing & fixing in position false ceiling at any level with Armstrong calla templock Sound Absorption (NRC) 85 % or equivalent Dune Max Micro look Acoustical Celling Tile 600X600X25MM with silhouette Grid System with framework as per specification with suspenders wherever required complete in all respect. with arrangement of MS work required for hold almost long span span and all scaffolding work required for 17 feet clear height false ceiling from floor.
SITC OF Kühl PLATIN D4 fan
SITC of 4 ton MITSUBISHI Cassete AC Four way Non Inverter Invertor Type Avg 80 Feet Copper pipe and Drainage pipe stand for outer unit do all compete job
Installation of Wall Hung WC With UF Soft Close Seat Cover, Hinges, Accessories Set, Size: 360x585x415 mm OPS-WHT-15951UF
Installation of cistern Single Piece Concealed Cistern Body (Front or Top Actuation) with Floor Mounting Frame, Installation Kit and “P-Type” Drain Pipe Connection Set for Wall Hung WC (without Flush Control Plate) JCS-WHT-2431FP
Jaguar 2 way bib cock antique chrome 35041 m
installation of Jaguar Anti Chrome Health Faucet ACR-573
installation of Jaguar Anti Chrome liquid soap dispenser ACR-1131N
Jaguar vitreous China sinks /wash basin KUS-WHT-35901 Description : Table Top Basin, Size: 595x435x185 mm
Waste coupling ALD-GDS-705L130 Description Waste Coupling 32mm Size Full Thread with 130mm height
Tall boy ALI-ABR-85005B Description Single Lever Tall Boy with 125mm Extension Body Fixed Spout without Popup Waste System with 600mm Long Braided Hoses
Jaguar Angle cock antique chrome 35053 pm
Connection Pipe With Nuts reputed brand
Jaguar Towel Ring antique chrome 1121N
Jaguar Tumbler Holder antique chrome 1141N
Jaguar paper Holder antique chrome 1141N
jaguar control plate antique chrome 852415
SWIVEL MIRROR 630 X 445MM AKP-CHR-35795 Description Swivel Mirror 630 X 445mm Rectangular Shape
Installation of pressure pump of Grundfos brand or equivalent 40 litre capacity with all accessories do all complete job
Installation of Geyser Jaguar 25 Litre ERM-WHT-V025
Lavish Vanity Cabinet 600 m wall hanging single made by Waterproofing material with minimum 5 year warenty do all complete job
Unbranded Floor Drain Traps having Linear Shape (Long drain ) for floor drainage and made up of SS 304
SITC of URS-WHT-13267S Urinal With Sensor Kit, Spreader And Fixing Accessories Set, Size:360X350X710 mm
SITC of Kohler Strive™ 30 inch (76.1 cm) top-/flush-/undermount single-bowl kitchen sin
Add 18 % GST
Add 1% Labour Cess
Ms Gokul Construction (BID ID -680547)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .