| 1 | 1₹2.2 LRejected-Finance 1077 SECTOR 16 AND 17 125001 | HISAR | HISAR | HARYANA | 125001 | 1 | Rejected-Finance Rates on lower side | |
| 2 | 2₹2.4 L+₹17,340.88 (7.87%)Rejected-Finance | 2 | Rejected-Finance Rates on higher side |
Tender Value
₹2.0 L
EMD Value
₹4,000
Closing Date
24 Sept 2020, 5:00 pmClosed
Executive Engineer
Provl. Divn. PWD BandR Br., Bhiwani
Renovation of Old Malaria Building 2nd floor in Ch. Bansi Lal General Hospital at Bhiwani in Bhiwani Distt.
2020_HRY_144982_1
Bhiwani_Renovation Old Malaria Building Rs.1.99 la
Open Tender
Civil Works
Works
60 days
Bhiwani
Please refer tender documents
2 documents required · 2 mandatory
₹500
Executive Engineer, Provl. Divn. PWD BandR Br.,
₹4,000
2 Nov 2020
18 Sept 2020
25 Sept 2020
18 Sept 2020
24 Sept 2020
18 Sept 2020
Amount
Dismantling Brick Work, Tile Masonry or Tile Lining and Tile Terracing in cement (8.5(b)
Stripping and stacking slates or tiles of a roof (HSR 8.10)
Removing doors and windows (wooden and steel) with chowkhats by making rece3sses in walls when the walls is not to be dismantlled (HSR 8.18) Doors
Cupboard
Windows
Clear Storey window
Dismantling cement conglemerate / terrazzo floors 25 mm to 50 mm thick without concrete base (HSR 8.26)
Scraping of White wash and colour wash (8.32(a)
Scraping of cement Plaster (8.32) ©
Scraping brick dismantling from brick work in lime or cement (HSR 8.32€
Tile terracing with one layer of tiles, 22.86 cm X 11.43 cm X 3.81 cm laid dry over a layer of mud mortar including grouting with cementsand mortar 1: 3 and top surface to be left clean.(HSR 13.14)
Providing & Fixing PVC Rainwater Pipe 6 kg. pressure of ISI mark in cement mortar during masonry work. (Note:- Reputed make PVC Pipe such as Supreme, Finolex, Prince will be used as approved by Engineer-in-charge. [HSR 13.89]. Note:- The Agency to whom the work is alloted will have to produce original bill/voucher for all quantity in token of proof of purchase of material. (a) 100 mm dia PVC pipe 6 kg. pressure.
Providing & fixing vitrified tiles of size 600mm x 600mm of approved make in flooring, laid in any pattern as specified over base of 20 mm thickcement coarse sandmortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. Note : Tile shall be of premium quality (first quality) of reputed manufacturer like:- NITCO, KAJARIA, SOMANI, JOHNSONS & JOHNSONS, ORIENT (HSR 14.89).
12 mm thick cement plaster 1:5 (HSR 15.6)
Cement Pointing 1:2 flush on flat brick flooring (HSR 15.71)
Providing and Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surface. (Note:- First quality paint of reputed make firm such as Goodlass-Nerolac, Berger, Garware, Jenson, Nicholson, Asian & Shalimar Shall be used as approved by Engineer-in-charge in writing, Drum of paint shall be opened in presence of Engineer-in-charge). (HSR 16.25).
Painting two coats with plastic emulsion paint on walls on new work to give an even shade (HSR 16.30)
Providing and applying two coats white cement based putty over plastered surface and grindling the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labour charges, scaffolding, sundries etc. complete. (Note:- reputed make Putty such as J.K./ Birla shall be used as approved by Engineer-in-charge). (HSR 16.81).
Providing and fixing aluminium gauge work for doors, window with glass panes, aluminium jali + Board in fixed position (NS)
Providing and fixing aluminium gauge work for doors & window vertical with glass panes aluminium sheets door closer, door fitting etc. (NS)
Providing and fixing in position best indian make viterous chinaware sinks with complete fittings as fully described in Item No.30.51 above 600mm x 450mm x 200mm (HSR 30.51+30.52(a)
Providing and fixing GI/ PVC and special (NS)
Providing and fixing in position 15mm i/d C.P. brass bib cocks of best quality (as required by the Engineer-in-charge). [HSR 30.75]. (a) Bib cock long body.
Providing and fixing in position CP brass stop cocks (as approved by the Engineer-in-Charge) 15mm stop cock (HSR 30.76(a)
Recovery items: The rates quoted against recovery items will not be included in the total amount rather it will be deducted while calculating financial statement of the agency. Material obtained from dismantling of existing brick work, bituminous layer and granular layers have been calculated taking assumption that 80% of theoretical material will be retrieved. The dismantled material can used in any of the item for the work after modification (bringing it to required specifications) after approval from employer. In case it is not possible to use this material on the work, the agency can take away this material. This material can be taken away by the agency at the price quoted by the agency but minimum price to be quoted is limited to reserve price as fixed and mentioned as under :-Note: All quantities of the below materials have been worked out on the basis of theoretical quantities laid on this road. However, agency may visit site before quoting rates and assess the extent of retrieved material. There shall be no measurement after actual dismantling and if material after dismantling is found on lesser side, no claim of agency on this score will be entertained and full recovery on the basis of quoted rate and quantity exhibited in the BOQ shall be made. The reserve rates are minimum rates to be used as base for quoting purchase rate by the agency. No rates below the reserve price will be entertained and reserve price will be considered for all purposes in case the agency quotes lesser than reserve price. Bricks 4944 Nos @ 4.00/- Each
Doors 12 Nos. @ 800/- Each
Windows 7 Nos. @ 500/- Each
Clear Storey window Ventilator 15 Nos. @ 500/-
Devraj Garg
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .