Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹20.6 L+₹5,944 (0.29%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | L3₹21.0 L+₹43,461 (2.12%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹22.7 L+₹2.2 L (10.8%)Rejected-AOC | L4 | Rejected-AOC OK | |
| 5 | L5₹27.7 L+₹7.1 L (34.8%)Rejected-AOC | L5 | Rejected-AOC OK |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
25 Nov 2020, 6:00 pmClosed
SHRI MAHAVIR SINGH, IDSE
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD
REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION AND ITS CONNECTED WORKS OF DAD AREA, CDA AND THEIR SUB UNITS, HANUMAN TEMPLE AREA UNDER AGE EM (SOUTH) OF GE (S) SECUNDERABAD
2020_MES_390074_1
GE (S)/SEC/TOKEN - 33 OF 2020 - 21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Secunderabad
For Enlisted contractors class D and above category b (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for eligible class along with EMD
5 documents required · 5 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹60,000
Yes
13 Jan 2021
26 Oct 2020
27 Nov 2020
26 Oct 2020
25 Nov 2020
12 Nov 2020
27 Oct 2020 - 10 Nov 2020
Amount
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed by Engg in Charge
Taking down carefully by unscrewing from boards/outlet boxes, fittings such as lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings etc for refixing at site in original position (when found serviceable in all respects complete) Note: Supply and fix of any consumable items will be measured and paid seperately
Disconnecting and removing the MCB DBs from any height ,stripping out the fitting for examine replacement of US spare parts, reassembling, refixing in original position including minor repairs for the smooth functioning and testing complete all as specified and as directed by Engg in Charge
M&L for attending, repair and rectification of any type of internal elect supply complaint viz light point/fan point/5/15 Amps switch socket/Submain wiring/MCBs/DBs on 230V/415V system along with necessary T&P, safety devices as per site requirement and as directed by Engr-in-Charge. Note : 1. The contractor shall detail/depute his supvr/electrician to receive the complaints from the concerned complaint cell and rectify the same on the given day alongwith necessary manpower and T & P as required. After completion of the complaints attended, the docket /slips shall be handed over to the concerned complaint cell. 2. The cost of the stationery such as complaint register and docket book shall be deemed to be included in the rate quoted.
M & L for Point wiring with 1.5 Sq mm copper conductor single core PVC insulated FRLS 1100 Volts multistranded drawn through and including rigid PVC conduit surface/concealed as required at site and conduit accessories of suitable dia medium grade in existing MS boxes duly cleaned as per existing site covered with new suitable sheet 3 mm thick for fixing switches / sockets/ regulators etc including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for One light/fan point controlled by one, one way switch 5 amps, SP complete all as specified and as directed
All as per Sl item No 5 here in before, but for One light point controlled by two 2 - w a y s w i t c h 5 amps, SP
All as per Sl item No 5 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Sl item No 5 here in before, but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Sl item No 5 here in before, but for One Bell point controlled by one, bell push
All as per Sl item No. 5 here in before, but for using 4 Sqmm single core copper conductor cable of multistranded PVC insulated FR 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 4 Sq mm copper conductor PVC insulated cable as earth continuity conductor
All as per Sl item No. 5 here in before, but for wiring drawn through PVC Casing and Capping, but for One light/fan point controlled by one, one way switch 5 amps, SP
All as per Sl item No. 11 here in before, but for One light point controlled by two 2 - w a y s w i t c h 5 amps, SP
All as per Sl item No. 11 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Sl item No. 11 here in before, but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Sl item No. 11 here in before, but for One Bell point controlled by one, one way switch 5 amps, SP
All as per Sl item No. 11 here in befor, but for using 4 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FR 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 4 Sq mm copper conductor PVC insulated cable as earth continuity conductor
M & L for Point wiring in concealed conduit complete all as specified with 1100 volts grade 1.5 sqmm PVC insulated FRLS, multistraded copper conductor conforming to IS:694:1990 with ISI marking (For Phase, Neutral and Earth) in and including Non mettalic PVC rigid conduit medium grade with ISI mark of size 20 mm dia with all accessories concealed in wall/ceiling/roof etc, for fixing modular switches, sockets fan regulators etc of suitable modules and earth wire to be connected to common earth dolly all as specified and directed for the following :Note : Modular cover plate with frame, flush box and modular switches will be inclusive of rate quoted.
All as per Sl item No 17 here in before, but for One light point controlled by two 2 - w a y s w i t c h 5 amps, SP
All as per Sl item No 17 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Sl item No 17 here in before, but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Sl item No 17 here in before, but for One Bell point controlled by one, bell push
All as per Sl item No. 17 here in before, but for using 4 Sqmm single core copper conductor cable of multistranded PVC insulated FR 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 4 Sq mm copper conductor PVC insulated cable as earth continuity conductor
S & F switch piano single pole flush type 5 amps, 230 volts.
S & F switch piano single pole flush type 15 amps, 230 volts.
S & F switch piano single pole Modular switch 1 way 6 Amps, 1 Module
S & F switch piano single pole Modular switch 1 way 16 Amps, 1 Module
S & F Switch piano two way flush type 5 Amps capacity 230 volts.
S & F switch piano Modular switch 2 way 6 Amps, 1 Module
S&F bell push 5 A flush type
S&F Modular Bell Push 6A, 1 Module
Supply and fix socket outlet modular type multipurpose 2/3 Pin, 6 amps, 230 volts combined 2 Module
Supply and fix socket outlet modular type multipurpose 3/5 Pin, 6/16 amps, 230 volts combined 2 Module
Supply and fix socket outlet flush type multipurpose 2 in 1, 3 Pin, 5 amps, 230 volts all as specified
Supply and fix socket outlet flush type multipurpose 2 in 1, 3 Pin, 5/15 amps, 230 volts all as specified
S & F switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1 230 Volts all as specified.
S & F switch socket combination 5 in 1 multipurpose 3/5 pin 5/15 amps flush typewith complete all as specified.
S & F Modular ceiling fan regulator stepped socket size (modular) suitable to work on 230 volts complete all as specified, 2 Module
S & F electronic type regulator stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified.
S&F buzzer working on 230 volts AC Supply
S&F bell ding dong working on 230 volts AC Supply
S & F lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings
S & F wall mounted LED batten of 09 watt with LED Lamp, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete all as specified and directed by Engg-in-Charge. Make : Havells Cat Part No Lumiline Plus BS10WLED865SPCSS/Luker cat Part No LT5M10/HPL cat Part No HLPT51510CW.
S & F wall mounted box type LED batten of 18/22 watt with LED Lamp, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete all as specified and directed by Engg-in-Charge . Make : Havells Pearl Batten Cat Part No LHFYBPNIA1W022/Lukar Cat Part No LLTS1/HPL cat Part No HLPLEDT8PC18CW.
S & F Security Lights of 1x15 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all as specified and directed by Engg-in-Charge. Make : Havells Endura Pearl cat Part No SL15WLED757SASYTOPC/ Lukar Cat Part No LST15/HPL cat Part No HPLLEDSL1560E.
S & F Security Lights of 1x25 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all as specified and directed by Engg-in-Charge. Make : Havells Cat Part No Endura Pearl SL25WLED757SASYTOPC/Lukar Cat Part No LST24/HPL Cat Part No HPLLEDSL2560E.
S & F 10 Watt surface mounted downlight with white powder coated polycarbonate housing and pressure diacast , heat sink having high efficiency and all as specified and directed by Engr-in-Charge
S & F 18 Watt surface mounted downlight with white powder coated polycarbonate housing and pressure diacast , heat sink having high efficiency and all as specified and directed by Engr-in-Charge
M & L bracket made out of GI pipe of 40/50 dia medium grade not less than 1.2 mtr long and fixed on walls with 2 nos MS clamps made out of MS flat of suitable size thick complete with MS nuts, bolts and washers etc bent to required shape complete all as specified and directed by Engg-in-Charge
S & F 24 watt recess softline luminaire (1x1) suitable for armstrong/grid ceiling with high brightness white LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal and all as directed by Engg in charge. Make : Havells Cat Part No PLR15WLED8575/Lukar Cat Part No LNPS24/HPL Cat Part No LEDPN30E(CW)
All as per Sl item No 49 here in before, but 2x2 fittings of 45 watts. Make : Havells Cat Part No Venus Neo HE 2x2PLR42WLED857MOD/ Lukar Cat Part No LKM2245/HPL Cat Part No HLPLEDCR040CW.
S & F 10 watt bulk head luminaire suitable for outdoor with high brightness giving glare free light and all as directed by Engg in charge. Make : Havells Rugby NEONFT Cat Part No 10W LED 860 SSYMT0PC/Lukar Cat Part No LBKOUSL04/HPL Cat Part No HLPLEDBHIOW(CW)
S & F MCB SP 6 to 32 Amps 240 volts for fixing on MCB DB's all as specified.
S & F MCB SP 32 to 63 Amps 240 volts for fixing on MCB DB's all as specified
S & F MCB SPN 16 to 32 Amps 240 volts for fixing on MCB DB's all as specified
S & F MCB SPN 40 to 63 Amps 240 volts for fixing on MCB DB's all as specified
S&F MCB Four pole, 415 volts suitable for fixing in MCB DB of capacity 63 Amps including removing the existing US one and making good the distrubed surface to match with the existing surface.
S&F MCB Four pole, 415 volts suitable for fixing in MCB DB of capacity 100 Amps including removing the existing US one and making good the distrubed surface to match with the existing surface.
S & F sheet metal enclosure MCB DB SPN 4 way with 200 amps rated bus bar 240 volts double door with locking system complete all as specified
All as per Sl item No 58 here in before, but SPN 8 way DB
All as per Sl item No 58 here in before but SPN 12 way DB
S & F Horizontal type TPN DB 4 way made out of CRCA sheet housing duly powder coated & confirming to IS 13032, IS 8623, BS 5486 completen all as directed by Engr-in-Charge.
S & F Vertical type TPN DB 4 way double door with incoming as MCCB TP 415 volts AC 3 phase 50 Hz with fixed magnetic setting for current rating of 100 Amps 16 KA (MCCB TP confirming to IS 13947 (P-2) IEC:947) made out of CRCA sheet housing duly powder coated & confirming to IS 13032, IS 8623, BS 5486 complete all as directed by Engr-in-Charge.
S & F Single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) all as specified and directed
S&F MCCBs 415V,25KA, 100 amps 3 Pole suitable for DB including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface.
All as per Sl item No 64 here in before, but 63 Amps, 10 KA
M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.
All as per Sl item No 66, but 2 runs of single core 6 sqmm and one run of single core 6 sqmm as earth continuty conductor Note : For Sl item No 66 to 67: Two runs of cable, one run of earth wire and one run of PVC conduit will be measured as one unit
All as per Sl item No 66, but 2 runs of single core 4 sqmm and one run of single core 4 sqmm as earth continuty conductor through existing conduit
All as per Sl item No 66, but 2 runs of single core 6 sqmm and one run of single core 6 sqmm as earth continuty conductor through existing conduit. Note :- For Sl item No 68 to 69: Two runs of cable, one run of earth wire in existing conduit will be measured as one unit
Fixing only LED tube of 18/20/22 Watts. Note: LED tube will be issued under Sch "B" free for fixing only.
Supply and replace of CFL Lamps 36 Watts retrofit type
Supply and replace of FTL 14 Watts Slim T5 lamp
Supply and replace of FTL 28 Watts Slim T5 lamp
Supply and replace of LED retrofit tube rod domestic 18 watts
Supply and replace of CFL Ballast 36 Watts
Supply and replace Ballast copper wound 36/40 Watts suitable for FTL 36/40W
Supply and replace Ballast electronic slim 18/20 Watts suitable for FTL 18/20W
Supply and replace Ballast Electronic slim 28 Watts suitable for T5
Supply and replace Ballast Electronic slim 14 Watts suitable for T5
Supply and replace BALLAST Electronic suitable for FTL fitting 1x36 watts
Supply and replace Electronic Driver for LED Light of 36 watts
Supply and replace Electronic Driver for LED Light of 24 watts
Supply and replace Electronic Driver for LED Light of 12 watts
Supply and replace Starter 40/36/ 20Watts,230 Volts
Supply and replace Bi pin holder suitable for 40 / 28 Watts tubes(pin & screw type)
Supply and replace CFL holder suitable for 2/4 Pin for 9 to 36 Watts
Supply and replace Fan condenser 2.5 mfd
Supply and replace fan condenser of 3.15/4.00 Mfd
Supply and replace split pins/lock pins for ceiling fans
Supply and replace MS Clamp with rubber bushes, bolts & nuts for ceiling fan along with lock pin complete all as specified and as directed
M & L for repairs to copper inner container like denting, soldering, brazing, leak testing and reassembling of any Ltrs capacity water heater (Geyser) complete all as specified and as directed.
Supply and replace Geyser element 2000 watts of any type
Supply and replace Thermostat
Supply and replace Indicator bulb 230 v suitable for any make and colour.
Supply and replace PVC Cold/Hot water connection pipe 45 cms long 15 mm dia
M & L Rewinding of burnt ceiling fan of 1200 / 1400mm sweep motor with supper enameled copper wire of suitable size including replacement of sealed bearing and shaft of any make, type, model incl transportation complete all as specified and directed by Engineer -in-charge.
M & L Rewinding of burnt Exhaust fan of 225 / 300mm sweep motor with supper enameled copper wire of suitable size including replacement of sealed bearing and shaft of any make, type, model incl transportation complete all as specified and directed by Engineer -in-charge.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed
Supply and replace PVC Round blocks
Supply and replace PVC Dummy sheets circular type of 4"
Supply and replace PVC Dummy sheets circular type of 6"
Supply and replace Rigid PVC casing & capping 20/25 mm wide
Supply and replace PVC rectangular box (Gang box) with 5 Amps switch socket
Supply and replace PVC rectangular box (Gang box) with 5/15 Amps switch socket
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate).
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earting etc as required 4mm dia galvanised iron or steel wire
Supply and fix/lay GI pipe 15 mm dia med grade for protection of earth continuity conductor
Supply and replace PVC wire of Flexible cord with copper conductor multistanded of twin core 23/0.198
Supply and replace PVC insulated FRLS copper wire of size 1.5 sq mm multistranded 1100 volts grade
Supply and replace PVC insulated FRLS copper wire of size 2.5 sq mm multistranded 1100 volts grade
Supply and replace PVC insulated FRLS copper wire of size 4.0 sq mm multistranded 1100 volts grade
Supply and replace PVC insulated FRLS copper wire of size 6.0 sq mm multistranded 1100 volts grade
Supply and replace Service wire twin core of 10.0 sq mm multistranded 1100 grade
Supply and replace 85W CFL lamps
Supply and replace 36W CFL lampms
Supply and replace Plug top 5 Amps 3 pin 250 Volts
Supply and replace Plug top 15 Amps 3 pin 250 Volts
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of andings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
Supply and replace pressed steel terminal boxes of size 4" x 4", 1.6 mm thick, MS duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement and as directed by Engr-in-Charge.
Supply and replace pressed steel terminal boxes of size 5" x 7", 1.6 mm thick, MS duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement and as directed by Engr-in-Charge.
Supply and replace pressed steel terminal boxes of size 6" x 8", 1.6 mm thick, MS duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement and as directed by Engr-in-Charge.
Supply and replace pressed steel terminal boxes of size 8" x 10", 1.6 mm thick, MS duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement and as directed by Engr-in-Charge.
Supply and replace pressed steel terminal boxes of size 10" x 12", 1.6 mm thick, MS duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement and as directed by Engr-in-Charge.
Supply & Fix energy efficient ceiling fan 1200 mm sweep copper winding, double ball bearings, five star rating and connecting up including down rod of suitable length as per site requirement and provn of three core flexible copper wire of size 23/0.0076 from ceiling rose to ceiling fan
SUN LIGHT HOUSE
gsrinivasarao
The Deccan Engineering and Refrigeration Company
M/S B.SHRAVAN KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .