Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC 38 BAGUIATI ROAD KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹41.1 L+₹2.3 L (6.00%)Rejected-Finance ROOM NO B 111 PART III GANESH MURTINAGAR CAPT PRAKASH PETHE MARG CUFFEPRADE CALABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹42.0 L+₹3.2 L (8.32%)Rejected-Finance PO CHANDL PS BISHNUPUR DIST SOUTH 24 PGS PIN 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹42.3 L+₹3.5 L (8.91%)Rejected-Finance TIORKHALI MAHESHGANJ NADIA | NADIA | NADIA | WEST BENGAL | 790804 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹43.5 L+₹4.7 L (12.1%)Rejected-Finance 72 A ABINASH CHANDRA BANERJEE LANE KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹37.3 L
EMD Value
₹74,520
Closing Date
31 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VIVEK TANENIA
GARRISON ENGINEER (CENTRAL) KOLKATA T37 NAPIER ROAD HASTING KOLKATA 700022
PROVN OF 40XWALL MOUNTING FANS IN OR LIVING BLDG NO P-44
2023_MES_613147_1
8620/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
KOLKATA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (C) KOLKATA
₹74,520
Yes
18 Mar 2024
10 Aug 2023
1 Sept 2023
10 Aug 2023
31 Aug 2023
26 Aug 2023
10 Aug 2023 - 25 Aug 2023
Amount
Demolition of cement concrete (Un-reinforced) in ground floor and paving nexc 15cm thick above or below GL complete all as specified and directed.
Demolition of brick work or stone masonary built in cement mortor including all quoins & jambs etc. complete all as specified and directed.
Surface Excavation not exc. 30 Cm deep and ave. 15 Cm deep and getting out in Soft/Loose Soil, complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth round, in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
M&L Hardcore of gauge not exc. 63 mm, broken stone aggregate deposited, spread andlevelled in layers n exc. 15 Cm thick, watered and rammed to a True Surface, complete all as specified and as directed.
M&L Moorum/red bajri filling in floors or pavings , laid in lyers 30 cm in thick spread , levelled and rammed including watering complete all as specified and directed by Engr-in-charge.
M&L Plain Cement Concrete type C-1, (1:3:6) (40mm graded crushed stone aggregate) as in Coping bed plate,hold fast etc,block benching,channeling slightly rounded or chamfered angle and throating including form work and finishing all exposed faces of cement concrete complete all as specified and as directed.
M&L Plain cement concrete (1:4:8) type D-2, using 40mm graded aggregate as in foundation and other similar location complete all as specified and as directed.
M&L RCC (Nominal Mix) 1:2:4 type B-0 (Using 12.50 mm graded stone aggreagate) as in coping ,benching etc., complete all as specified and as directed.
M&L Pre-cast Reinforced Cement Concrete type B1(1:2:4) using 20 mm graded crushed stone aggregate) as in Cover Slab of Man Holes, Septic Tanks, chulla hoods and similar articles etc., set in Cement Mortar 1:4 including necessary forms, moulds, etc., complete all as specified and as directed. NOTE : Reinforcement shall be measured and paid separately under relevant Item.
Cutting chase, pinning in making good to facing where required and pointing in CM 1:3 to end or edges of landing steps, cills, sunshades, shelves, lintels etc. and cutting chase for concealed water pipe etc. and making good cutting not exc 10Cm girth.
M&L fly ash bricks pulverizes using class 'A 'old size bricks straigth or curved on plan exc 6m mean radius built in CM (1:6) cmplete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to fe 410-S.complete all as specified and as directed.
M&L Steel Work in Tubular Post/Trusses hollow section including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-4923 grade YSt.-240 complete all as specified and as directed.
S&F Plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming toFe-410-W (Gde-E- 250 quality -B) complete all as speci-fied and as directed.
M&L Mild Steel Screw Bolts (machine made) 16mm to 20mm diameter of neck and length of bolt exc 15 Cm and not exc. 22.5 Cm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, fixed with self tapping screw complete all as specified and directed.
M&L for 150mm thick plain cement concrete type C-2 (1:3:6) (Using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
M&L for 150mm thick plain cement concrete type D-2 (1:4:8) (Using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, complete all as spcified and directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, complete all as spcified and directed.
M&L Rendering 15mm thick in Cement Mortar (1:4) on fair faces of brick work or concrete surface of wall using water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified and as directed. (NOTE:-WPC shall be measured and paid separately)
M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed.
Supply and Laying Steel Water Tubing 15mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed.
S&F Gun Metal Globe/Gate Valve 15 mm dia (bore) with Iron Wheel Head screwed both Ends for Iron Pipes and fixed-in-repairs, complete all as specified and as directed.
M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan /call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 4.0 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 4.0 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan /call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
S&F Switch socket combination multipurpose 2 in 1, 3 pin 5 & 15 Amps 230/240 volt flush type as in repair complete all as specified and as directed.
S&F Switch piano, flush type, SP, one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawn into rigid non metalic PVC concealed conduit of size 25 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 6.0 Sqmm conductor as main wire and one run of 6.0 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawn into rigid non metalic PVC concealed conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 4.0 Sqmm conductor as main wire and one run of 4.0 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
S&F AC starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewired including taking down of old UNSV one complete as specified all as directed by Engr-in-charge.
Supply install testing and commissioning of water cooler fully stainless steel electric driven single phase having approx storage and nominal cooling capacity 150/150 ltrs complete all as specified and as directed by Engr in charge Make voltas blue star
Supply and fixing automatic stablizer for water cooler to protect against voltage fluctation complete all as directed by Engr in charge. Make mikroteck automatic voltage stabilizer smart EMR(130V-295V) Cat No SKU:899-251-2013 or equivalent in V guard/godrej/ whirpool/voltas
S&F Wall mounted fan AC single phase 240 V of size 450 mm sweep metal body and blade, powder coated metalic finishes complete all as directed and specifed.
M/S SRINIVASA CONSTRUCTION
UNITED ENGINEERS
SHEIKH ENTERPRISE
MS HORIZEN
HYDROTEC
KWALITY CONSTRUCTION
SRI BHOOMIJ INFRAPROJECTS & SERVICES LLP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .