| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-Finance GROUND FLOOR MATTA COMPLEX GENERAL POST OFFICE M A LINK ROAD MUNWARABAD SRINAGAR JAMMU AND KASHMIR 190001 UDYAM JK 21 0020925 | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹24.9 L | L1 | Accepted-Finance Responsive |
| 2 | L2₹29.6 LAccepted-Finance | ₹29.6 L | L2 | Accepted-Finance Responsive |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
| Sl No | Description | Qty | Unit | Health Imaging Pharmaceuticals L2 | Helpline Medical Systems L1 |
|---|---|---|---|---|---|
| 1.00 | Fully digital, whole body Color Doppler Ultrasound machine with Touch Penal Facility | 1 | complete job | 29,55,000 ₹29.6 L | 24,90,000 ₹24.9 L |
| 1.01Should be top of the line and State of the Art fully digital portable ultrasound machine with provision for Doppler examinations • It should be suitable for abdominal, Obstetrics, Gynecological, Cardiac Vascular, Thoracic, Transcranial, • Musculoskeletal, Urological, Small Parts, for adults andpediatric patient. • Multiple preloaded as well as user configurable application presets should be available. • The system should have advanced measurement, manual and automatic for all applications. • The system should an integrated high resolution TFT / LCD of minimum 21” (flicker free images) or more. • System should have multi gesture touch panel of > 13 inches • The system should have image storage space 500GB or more • The system should have minimum 200000 or more digital processing channels and 256 or more grey shades. • The system should have scanning depth to be 30 cm or more. • The system to have a dynamic range of 250 decibels or more. • System should support transducer technologies like phased array, convex, linear, endocavity, micro convex and 4D volume etc. • All transducers should be lightweight digital phased array broadband type transducers. • System should have 3 active port and should have electronic switching ability between the transducers without the need of manual disconnection • Should be supplied with Threetransducers (one each): 1. Convex electronic phased array transducer: 2-6 (+/-1) MHz for abdominal imaging. 2. Linear transducer: 6-15 (+/-2) MHz for vascular and small part imaging. 3. TV/TR probe 4 -10 MHz for OB/ GYN, Transvaginal and Transrectal 4. Adult Cardiac Probe 1-4 MHz for Cardiac Applications | |||||
| 1.02• System should have online scan assistant • System should have DICOM 3.) connectivity • System should have capability of real time automatic Doppler calculations • Convex. TV/TR and linear transducers shall have detachable reusable biopsy guides for different gauge needles • The system should have a frame rate of at least 1500 frames per seconds (fps) in B mode and more than 600 fps in Color mode. • System should have line density more than 900 • System should have Li Rad option inbuilt in the system • System should have B- flow • System Should have strain Elastography • System should have LGC • System should be upgradable to Auto ef and stress echo • System should dynamic tissue optimization • System should be upgradable to real time 3D/ 4D imaging • Should have capability to scan large organ ( upto 60 cm) in a stretch • System should have Cross beam imaging for better organ visualization • Should have TVI, AMM and IMT for Cardiac scanning • System should onboard tutor for learning and enhancing the technical skill for patient scanning Scan coach. • The system should have an ergonomic full alphanumeric soft keys keyboard with easy access scans control and trackball or touchpad. | |||||
| 1.03• The Systems should have cine loop review facility of not less than 400 sec/300000 inages. • The system should have the facility of digital storage and retrieval of B/W and colour image data. • System should have AI enabled auto labelling feature for RUQ • Provision for USB port and LAN transfer of data should also be present. • The system shall support the all DICOM functionality, Storage, Print, and Work List, also ready to connect toPACS. • The system should have more than 500 user defined presets • Imaging modes of Real time 2D, Colour, Pulsed wave, Continuous Wave and Power (energy) Doppler, Anatomical M-Mode should be available. • The system should have boot up time not more than 2 min • The system should have doppler velocity range from 0.1 cm / Sec – 1000 cm/ Sec • Controls for 2D mode: Total gain, depth, TCG, dynamic range, acoustic power output. • Controls for Colour Doppler: PRF, colour gain, position and size of ROI, steering of ROI, colour maps and colour invert. • Measurements for 2D mode: Multiple distances, area and volume. • Measurement for Doppler modes: Stenosis quantification in area percentage, Diameter, PSV, EDV, means, PI, RI, acceleration time and index. Automatic and manual measurements and display of pulsed Doppler calculations should be possible. • Unit should function with 200-240 V, 50 Hz AC, 5-amp power outlet power requirement to be specified • System should have both Triplex and Duplex display and a wide range of probes, increases system versatility and adaptability to our clinical needs. • | |||||
| 1.04System should be upgradable to Enhanced Needle Tracking,Panoramic Imaging and 3D software in future. • System should have capability to compare the current exam to the previous exam • System should have continuous optimization the images when scanning different tissues • System should have onboard contextual reference tool • System should have Lateral gain compensator • System should have probe check and e-Delivery features • The unit should beUnited States Food and Drug Administration (USFDA) approved. • System should have capability of probe check built in the machine • System should have capability for Voice comment recording during scanning • System should be able to connect with end firing linear probe with frequency 5- 10 Mhz • Additional Items Required 1. 3KVA Online UPS with 3Hr Backup 2. Color Printer 3. Thermal Printer 4. Isolation Transformer 5. Automatic Servo Stabilizer The whole system supplied should carry 3 Years Warranty. No deviation on specifications will be acceptable. Compliance sheet to be attached to the tender without any deviation. Configuration list to be attached properly mentioning Make and model of the equipment. Brochures and all required certificates to be attached in the tender. Proven service center in the valley from more than 5 Years. | |||||
| 2.001. Note:- The rates quoted by the bidder/s shall be final and inclusive of taxes, carriages of all materials (Mechanical/Manual) and all extra charges till the Installation, Testing of equipment/s is complete in all respects. | |||||
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
29 Mar 2025, 1:00 pmClosed
DSW-SKUAST-K
shalimar
Procurement of Fully digital, whole body Color Doppler Ultrasound machine with Touch Penal Facility Under Development Grant at Medical Unit, Main Campus Shalimar, SKUAST-K.
2025_SKUST_274719_2
E-NIT02of2025
Open Tender
Laboratory and scientific equipment
3 days
main campus shalimar
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Assistant comptroller
₹30,000
11 Dec 2025
22 Mar 2025
29 Mar 2025
22 Mar 2025
29 Mar 2025
22 Mar 2025
Amount
Fully digital, whole body Color Doppler Ultrasound machine with Touch Penal Facility
Should be top of the line and State of the Art fully digital portable ultrasound machine with provision for Doppler examinations • It should be suitable for abdominal, Obstetrics, Gynecological, Cardiac Vascular, Thoracic, Transcranial, • Musculoskeletal, Urological, Small Parts, for adults andpediatric patient. • Multiple preloaded as well as user configurable application presets should be available. • The system should have advanced measurement, manual and automatic for all applications. • The system should an integrated high resolution TFT / LCD of minimum 21” (flicker free images) or more. • System should have multi gesture touch panel of > 13 inches • The system should have image storage space 500GB or more • The system should have minimum 200000 or more digital processing channels and 256 or more grey shades. • The system should have scanning depth to be 30 cm or more. • The system to have a dynamic range of 250 decibels or more. • System should support transducer technologies like phased array, convex, linear, endocavity, micro convex and 4D volume etc. • All transducers should be lightweight digital phased array broadband type transducers. • System should have 3 active port and should have electronic switching ability between the transducers without the need of manual disconnection • Should be supplied with Threetransducers (one each): 1. Convex electronic phased array transducer: 2-6 (+/-1) MHz for abdominal imaging. 2. Linear transducer: 6-15 (+/-2) MHz for vascular and small part imaging. 3. TV/TR probe 4 -10 MHz for OB/ GYN, Transvaginal and Transrectal 4. Adult Cardiac Probe 1-4 MHz for Cardiac Applications
• System should have online scan assistant • System should have DICOM 3.) connectivity • System should have capability of real time automatic Doppler calculations • Convex. TV/TR and linear transducers shall have detachable reusable biopsy guides for different gauge needles • The system should have a frame rate of at least 1500 frames per seconds (fps) in B mode and more than 600 fps in Color mode. • System should have line density more than 900 • System should have Li Rad option inbuilt in the system • System should have B- flow • System Should have strain Elastography • System should have LGC • System should be upgradable to Auto ef and stress echo • System should dynamic tissue optimization • System should be upgradable to real time 3D/ 4D imaging • Should have capability to scan large organ ( upto 60 cm) in a stretch • System should have Cross beam imaging for better organ visualization • Should have TVI, AMM and IMT for Cardiac scanning • System should onboard tutor for learning and enhancing the technical skill for patient scanning Scan coach. • The system should have an ergonomic full alphanumeric soft keys keyboard with easy access scans control and trackball or touchpad.
• The Systems should have cine loop review facility of not less than 400 sec/300000 inages. • The system should have the facility of digital storage and retrieval of B/W and colour image data. • System should have AI enabled auto labelling feature for RUQ • Provision for USB port and LAN transfer of data should also be present. • The system shall support the all DICOM functionality, Storage, Print, and Work List, also ready to connect toPACS. • The system should have more than 500 user defined presets • Imaging modes of Real time 2D, Colour, Pulsed wave, Continuous Wave and Power (energy) Doppler, Anatomical M-Mode should be available. • The system should have boot up time not more than 2 min • The system should have doppler velocity range from 0.1 cm / Sec – 1000 cm/ Sec • Controls for 2D mode: Total gain, depth, TCG, dynamic range, acoustic power output. • Controls for Colour Doppler: PRF, colour gain, position and size of ROI, steering of ROI, colour maps and colour invert. • Measurements for 2D mode: Multiple distances, area and volume. • Measurement for Doppler modes: Stenosis quantification in area percentage, Diameter, PSV, EDV, means, PI, RI, acceleration time and index. Automatic and manual measurements and display of pulsed Doppler calculations should be possible. • Unit should function with 200-240 V, 50 Hz AC, 5-amp power outlet power requirement to be specified • System should have both Triplex and Duplex display and a wide range of probes, increases system versatility and adaptability to our clinical needs. •
System should be upgradable to Enhanced Needle Tracking,Panoramic Imaging and 3D software in future. • System should have capability to compare the current exam to the previous exam • System should have continuous optimization the images when scanning different tissues • System should have onboard contextual reference tool • System should have Lateral gain compensator • System should have probe check and e-Delivery features • The unit should beUnited States Food and Drug Administration (USFDA) approved. • System should have capability of probe check built in the machine • System should have capability for Voice comment recording during scanning • System should be able to connect with end firing linear probe with frequency 5- 10 Mhz • Additional Items Required 1. 3KVA Online UPS with 3Hr Backup 2. Color Printer 3. Thermal Printer 4. Isolation Transformer 5. Automatic Servo Stabilizer The whole system supplied should carry 3 Years Warranty. No deviation on specifications will be acceptable. Compliance sheet to be attached to the tender without any deviation. Configuration list to be attached properly mentioning Make and model of the equipment. Brochures and all required certificates to be attached in the tender. Proven service center in the valley from more than 5 Years.
1. Note:- The rates quoted by the bidder/s shall be final and inclusive of taxes, carriages of all materials (Mechanical/Manual) and all extra charges till the Installation, Testing of equipment/s is complete in all respects.
Health Imaging Pharmaceuticals (BID ID -2352264)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_847309.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid