Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹47.4 L+₹2.8 L (6.30%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹48.2 L+₹3.6 L (8.00%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹48.6 L+₹4.0 L (9.01%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹49.2 L+₹4.6 L (10.4%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹44.8 L
EMD Value
₹89,580
Closing Date
27 Nov 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
ADDITION / ALTERATION TO BUILDING No.130 AND CONFERENCE HALL IN CCG AT DMRL HYDERABAD AND CERTAIN SANCTION WORKS UNDER GE(I) RND KANCHANBAGH
2023_MES_627305_1
GE I KBAGH TOKEN 88 OF 2023 2024
Open Tender
Civil Works
Item Rate
240 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹89,580
Yes
29 Jan 2024
7 Nov 2023
29 Nov 2023
7 Nov 2023
27 Nov 2023
21 Nov 2023
7 Nov 2023 - 14 Nov 2023
Amount
ADDITION / ALTERATION TO BUILDING No 130 AND CONFERENCE HALL IN CCG AT DMRL HYDERABAD
Providing and laying 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size derived from natural sources) in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level
Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:6 complete
Providing Half brick masonry with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in super structure above plinth level up to floor V level in cement mortar 1:4
15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete .
Providing and laying cement concrete in retaining walls, return walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, sunken floors etc up to floor five level excluding the cost of centering shuttering and finishing :- (i) 1:2:4 (1 cement : 2 coarse sand ( zone -III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources )
M&L PCC 1:2:4 ( 1 cement : 2 manufactured sand derived from Recycled concrete aggregate (RCA) up to 25 % : 4 graded stone aggregate 20 mm nominal size recycled concrete aggregate (RCA) up to 25 %)
Reinforced cement concrete work in suspended floors, roofs slab supported on walls having slope up to 15 o above plinth level up to floor five level, excluding cost of shuttering finished and reinforcement with 1 : 1 1/2 : 3 ( Zone -III) derived from natural sources complete
Centering and shuttering including strutting, propping etc and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilever
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level :- (i) Thermo - Mechanically Treated bars of grade Fe- 500D or more
Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window cills, facias and similar locations of required size, approved shade , colour and texture laid over 20mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joint treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to edges to give high gloss finish etc complete at all levels (i) Granite stone slab colour black, cherry / ruby Red , area of slab up to 0.50 Sqm
Providing edge moulding to 18mm thick granite stone counters, Vanities etc, including machine polishing to edge to give high gloss finish etc complete as per design approved by Engr -in-charge
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling CP brass/ stainless steel screws, all complete as per architectural drawings and the directions of engr -in- Charge. (Glazing, paneling and dash fasteners to be paid for separately) :- (i) For fixed portion powder coated aluminium ( minimum thickness of powder coating 50 micron)
M&L for Aluminium shutters of doors, windows & ventilators powder coated aluminium ( minimum thickness of powder coating 50 micron) including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required ( Fittings shall be paid for separately)
Providing and fixing anodized aluminium grill ( anodized transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design / pattern with approved standard section and fixed to the existing windows frame with CP brass / stainless steel screws @ 200mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodized aluminium standard section around the opening all complete as per direction of Engr -in- Charge
Proving and fixing glazing in aluminium door, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings and the directions of Engineer-in-charge:- (i) With float glass panes of 5mm thickness ( weight not less than 12.50 Kg/ Sqm)
S&F 12mm thick both side prelaminated particle board to aluminium door, partition complete all as specified
Providing and fixing aluminium powder coated 50 micron thickness round shape handle of out dia 100mm with SS screws etc complete as per direction of Engr-in-charge
Providing and fixing aluminum extruded section body universal type hydraulic door closer ( having brand logo with ISI , Is : 3564, embossed on the body, door weight up to 36 to 80 kg and door width from 701 to 1000mm) with double speed adjustable with necessary accessories and screws etc complete
Providing and fixing brass 100mm mortice latch and lock with 6 levers without pair of handles ( best make of approved quality) for aluminium door including necessary cutting and making good etc complete
Cement concrete 1:2:4 ( 1 cement ; 2 coarse sand : 4graded stone aggregate 40mm nominal size ) in pavements, laid in required slope and camber in panels as required including consolidation finishing and tamping complete
Steel work in built up tubular hot finished welded type tubes ( round, square or rectangular hollow tubes etc) trusses etc including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer including welding and bolted with special shaped washers etc complete
Providing and fixing steel work in gratings, frames, guard bars, ladders, railing, brackets, purling, gates and similar works welded in built up sections / frames work, including cutting, hoisting, fixing in position and applying priming coat of approved steel primer using structural steel as required
Providing and fixing 0.56mm aluminium color coated profile with centre to centre pitch of 175mm , depth of 46mm, top crest width of 41mm, bottom valley width of 80mm overall profile width of 1144, cover width 1050mm at all height, levels and locations colour finish aluminium alloy roofing sheets of alloy IS designation 31500, temper H x8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance.
Providing and fixing of percolated / mill finish aluminium ridges plain ( 500 -600mm) pre- coated colour or mill finish aluminium roofing accessories in 0.71mm thickness , alloy 31500 (IS designation) (Aluminium alloy (AA) 3004 (ISO designation) for colour coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15- 18 microns using self drilling/ tapping SS screws of size 6 x 50mm with washer complete
Providing and fixing 12.5mm thick tapered edge Glass reinforced Gypsum board conforming to IS : 2095 (Part 3) : 1996 false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from MS sheet and galvanized with zinc coating of 120gms/ sqm ( both side inclusive ) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm at 1200mm centre to centre, one flanges fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x,50mm of required length with nut & bolts of required size , Gypsum board of 12.5mm thick with white paper layer on face side of size 600 x 600 mm as directed
Distempering Two or more coats on new work with Ist quality acrylic distemper , having VOC ( Volatile Organic Compound) content less than 50 grams / liter of approved brand and manufacture of required shade and colour complete as per manufacturer's specification
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface
Finishing wall with Acrylic smooth exterior paint on old work ( two or more coats applied @ 1.67 ltr/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 kg/ 10 Sqm of required shade complete
White washing on new work ( three or more coats) with lime to give an even shade
Removing white, colour wash and existing treatment by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc complete
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping , sand papering and preparing the surface smooth including necessary repairs to scratches etc complete
Providing and laying Double charge vitrified tiles size 600 x 600mm in floor in different size ( thickness to be specified by the manufacturer ) with water absorption less than 0.08 % and conforming to IS : 15622 of approved brand & manufacturer, in all colors and shade , laid on 20mm thick cement mortar 1:4 jointing with grey cement slurry @ 3.3 kg/Sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Providing and laying vitrified tiles in different sizes ( size of tiles 600 x 600 mm) ( thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colors & shade , in skirting, riser of steps , over 12mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg / Sqm including grouting the joint with white cement & matching pigments etc complete
Dismantling doors, windows and clerestory windows ( steel or wood) shutter including chowkhats, architrave, holdfasts etc complete and stacking within 50 meters lead :-
providing and fixing pressed steel door frames conforming to IS: 4531, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25mm, or base ties of 1.60mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre- treatment of the surface as directed by Engineer -in- Charge :- (i) Profile 'E' fixing and adjustable lugs with split end tail to each jambs
Providing and fixing ISI marked 35mm thick flush door shutters including ISI marked stainless steel butt hinges with necessary screws flush door shutters conforming to IS : 2202 (Part -I) decorative type, core of block board construction with frame of Ist class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters
Providing and fixing ISI marked MS pressed butt hinges 100 x 58 x 1.90mm bright finished with necessary screws etc complete
Providing and fixing aluminium tower bolts 150 x 10mm, ISI marked, anodized ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc complete
Providing and fixing aluminium handles 125mm , ISI marked , anodized ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc complete
Providing and fixing aluminium sliding door bolts 300 x 16mm , ISI marked anodized ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nut and screws etc complete
Providing and fixing aluminium Twin rubber stopper hanging floor door stopper, ISI marked, anodized ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade , with necessary screws complete
Providing wood work second class teak work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing 18mm thick both sides pre laminated cement bonded wood particle board as per IS : 15786 : 2008 of approved brand and shade with suitable full threaded steel screws etc in partitions, boxes, shelves, racks and cupboard , kitchen cabinet under kitchen counter etc all complete as per direction of Engr-in-charge.
Providing and fixing IInd class teak wood 50 x 20mm wooden moulded beading to door and windows frames, support to shelves with iron screws, plug and priming coat on unexposed surface etc complete
Providing MS continuous (piano) hinges of flap overall width 35mm, ISI marked IS : 3818 finish with nickel plating and fixing with necessary screws etc complete all as directed.
Painting two or more coat on new wood work with synthetic enamel paint of approved brand and manufacture to give an even shade
Painting on new steel surface ( two or more coats ) including a coat of approved steel primer ( red oxide primer) with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
Dismantling aluminium / gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable materials and stacking of serviceable materials within 50 meters lead as directed by engr -in- charge
Making the opening in brick masonry for door/ window/ clerestory window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba / rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer -in-Charge
S&F venetian blinds (vertical type) of 100mm wide straps with all fittings (to be matched with existing patters) & taking down old venetian blinds complete all as specified and as directed.
Providing and placing on terrace ( at all floor levels) polyethylene water storage tank, 2000 ltr capacity Is: 12701 marked , with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing PTMT ball cock of approved quality , colour and make complete with Epoxy coated aluminium rod with LP / HP HD plastic ball :- (i) 20mm nominal bore 120mm long , weighing not less than 198 gems
Providing and fixing gun metal gate valve 20mm nominal bore with CI wheel of approved quality ( screwed end) complete
Providing and fixing GI pipes 15mm dia nominal bore complete with GI fittings and clamps i/c making good the walls etc concealed pipe including painting with anti corrosive bit mastic paint cutting chases and making good the wall
Providing and fixing 20mm dia nominal bore GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc
Providing and fixing white vitreous china laboratory sink with CI brackets, CP brass chain with rubber plug, 40mm CP brass waste and 40mm CP{ brass trap with necessary cap brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required :- (i) Size 600 x 450 x 200mm
Random rubble masonry with hard stone in superstructure above plinth level and up to floor five levels, including leveling up with cement concrete 1:6:12 at window cills , ceiling level and the like in cement mortar 1:6 complete
E/M portion (Internal)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required One light point controlled by one way modular switch 6 Amps
All as per item No.58 above one ceiling fan point /Exh fan point controlled by one 5 Amps one way switch and regulator
All as per item No.58 above one 3 pin 5 Amps switch socket outlet point on independent board
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No.4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. outlet. 15 amps, independent:-
Supplying and fixing PVC batten/ angle holder including connections etc. as required
S&F LED light fitting 1x20 W, 4ft Extruded aluminium batten suitable for surface mounting complete
Supply & fix LED down lighter, fully diffused recessed mounted 2'x2', 30 W, 6500K, with high transitive diffuser suitable for indoor complete
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. for single pole
S&F MCB SPN 240 Volts 40 Amps complete
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc.of 100A capacity
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
Supplying and fixing 40 A, 415 V, TPN Industrial type socket outlet, with 3 pole and earth, metal enclosed plug top along with 40 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. of 8 way double door complete.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) for 8 way (4 + 24), Double door
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required for 2X 6 sq. mm + 1 X 6 sq. mm earth wire
All as per item No.72 above but 4 x 6 sq. mm + 2 x 6 sq. mm earth wire
All as per item No.72 above but 4 x 10 sq. mm + 2 x 10 sq. mm earth wire
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground ( earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip of 25x4mm (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5, connected to earthing test point all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber and RCC 1:2:4 type B1 cover 40 mm thick, with 8 mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 40 mm dia GI light grade pipe for earth lead protection, 20 mm dia GI light grade pipe for watering , water funnel, testing point etc., complete all as specified and testing on completion.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed by Engr-in-Charge.
Supply & fix Ceiling fan 230 volts single phase 1200 mm sweep, 340RPM, 210CMM air delivery suitable for wall mounting
Supply & fix Exhaust fans 230 volts single phase 300 mm sweep, with louvers complete suitable for wall mounting
Supply & fix Wall mounted fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting
E/M portion (AC)
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ionizer and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 2.0 TR complete all as directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ionizer and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as directed.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required for 2 x 4 sq. mm + 1 x 1.4sq. mm earth wire
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5KVA
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4KVA
Supply, laying, testing and commissioning in trenches/ ducts, fixed on walls/panels of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100, volts grade, cross-sectional area 35 Sqmm 3.5 core complete
PROVISION OF SPECIAL REPAIRS TO COOLING APPLIANCES AGAINST BER AT RCMA(MATERIAL).
Supply and install inverter type hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ionizer and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TR with brackets and including with all connections as per site requirement complete. Make : Voltas/Blue star/Daikin/Lloyd
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA
PROVISION OF EARTHING FOR BOTH THE X-RAY BAGGAGE SCANNER MACHIN LOCATED AT DMRL & ATC
M&L for Earthing complete with copper plate 60×60cm ×3mm thick electrode and 20×3mm copper strip, buried directly in ground (earth pit not less than 2.7 meters using as earthing lead deep below ground level) with top edge of the plate not less 'than 1.5 meters below normal ground level, connected to copper earth strip of size 25x5mm by means of bolts, nuts, check nuts and washers of galvanized ironer steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as directed.
Supplying and laying 25 mm x5 mm copper strip at 0.50 meter below ground as strip as strip earth electrode, including connection/terminating with nut,bolt,spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced as 50 mm
PROVISION OF PERMANENT SECURITY POST AT RCMA (MAT) HYDERABAD (B/R Portion)
Excavation work in ordinary soil by mechanical means ( hydraulic excavator) / manual means in foundation trenches or drains ( not exceeding 1.5m in width or 10 sqm on plan) incluindg dressing of sides and ramming of bottom lift upto 1.5m incluindg getting out the excavated soil and disposal of surplus excavated soils as directed within a lead of 50 mtr
Providing and laying 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size derived from natural sources) in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolanna / Ordinary Portland / portland slag cement admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete , to improve durability and workability without impairing strength including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engr-in- Charge for the following graded or concrete all works upto plinth level . Concrete of M-25 grade with minimum cement content of 330 Kg/ Cum for beam, lintel
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolanna / Ordinary Portland / portland slag cement admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete , to improve durability and workability without impairing strength including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engr-in- Charge for the following graded or concrete all works above plinth level upto floor V level. concrete of M-25 grade with minimum cement content of 330 Kg/ Cum for beam, lintel
Centering and shuttering including strutting, propping etc and removal of form for Foundations, footing, bases of columns etc
All as per item no. 95 above but Lintels, beams, plinth beams, girders, bressumers and cantilever
All as per item no. 95 above but Columns, pillars, piers, Abutments, post and struts
All as per item no. 95 above but Suspended floors, roof, landing, balconies and access platforms
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level :- Thermo - Mechanically Treated bars of grade Fe- 500D or more
Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo - Mechanically Treated bars of grade Fe- 500D or more
Steel reinforcement for RCC work ready to use "cut and bend" rebars of approved make from factory / workshop to construction site including placing in position and binding all complete above plinth level . Thermo / Mechanically Treated bars of grade Fe- 500D or more
Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:4 complete
15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete .
15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete .
6mm thick cement plaster 1:3 ( 1 cement : 3 fine sand) on ceiling surface finished with a floating coat of neat cement and thick coat of lime wash on top of ceiling when dry for bearing of RCC slabs and beams
Distempering Two or more coats on new work with Ist quality acrylic distemper , having VOC ( Volatile Organic Compound) content less than 50 grams / litre of approved brand and manufacture of required shade and colour complete as per manufacturer's specification
Finishing wall New work ( Two or more coats applied @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 Sqm with 100 % premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489 : 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade ( Company Depot tinted ) with silicon additives
White washing on new work ( three or more coats) with lime to give an even shade
Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window cills, facias and similar locations of required size, approved shade , colour and texture laid over 20mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joint treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to edges to give high gloss finish etc complete at all levels (i) Granite stone slab colour black, chery / ruby Red , area of slab upto 0.50 Sqm
Providing edge moulding to 18mm thick granite stone counters, Vanities etc, incluidng machine polishing to edge to give high gloss finish etc complete as per design approved by Engr -in-charge
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling CP brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engr -in- Charge. (Glazing, paneling and dash fasteners to be paid for separately) :- (i) For fixed portion powder coated aluminium ( minimum thickness of powder coating 50 micron)
M&L for Aluminium shutters of doors, windows & ventilators powder coated aluminium ( minimum thickness of powder coating 50 micron) including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required incluindg the cost of EPDM rubber/ neoprene gasket required ( Fittings shall be paid for separately)
Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design / pattern with approved standard section and fixed to the existing windows frame with CP barss / stainless steel screws @ 200mm centre to centre incluidng cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per direction of Engr -in- Charge
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings and the directions of Enginer-in-charge:- (i) With float glass panes of 5mm thickness ( weight not less than 12.50 Kg/ Sqm)
Providing and laying ceramic glazed floor tiles of size 300 x 300 mm or more ( thickness to be specified by the manufacturer) of !st quality conforming to IS : 15622 of approved make in colours and shade except white ivory, Grey, fume Red Brown, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 Coarse sand) , jointing with grey cement slurry @ 3.3 Kg/ Sqm incluidng pointing the joints with white cement and matching pigment etc complete
Making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20mm nominall size derived from natural sources) of 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand , including necessary excavation, levelling & dressing & finishing the top smooth.
Returning filling in trenches incl spreading,levelling , watering & well ramming in layers n.exc 25 CM thick
Supplying and filling in plinth / under floor with sand under floors including watering, ramming, consolidating and dressing complete
Supplying , filling, spreading and spreading hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and leveled in layers not exceeding 15 cm thick, watered and rammed to a true surface.
Disposal of building rubbish / malba/ similar unserviceable, dismantled or waste materials by mechanical means, incluidng loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer -in- charge beyond 50m initial lead for all leads incluidng all lifts involved.
Demolishing brick work in cement mortar manually / by mechanical means includng stacking of serviceable materials and disposal of unserviceable materials within 50 meter leads as per direction of Engr -in- Charge
Demolition R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable materials within 50 metres lead as per direction of Engineer -in- Charge
PROVISION OF PERMANENT SECURITY POST AT RCMA (MAT) HYDERABAD (E/M Portion)
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required for 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as require One light point controlled by one way modular switch 6 Amps
One light point controlled by one way modular switch 6 Amps
One ceiling fan point controlled by one 6 Amps one way switch and regulator
One 3 pin 6 Amps switch socket outlet point on independent board
One 3 pin socket outlet 6 Amps on the same board with other switches.
S&F modular type switch 16 A, 230V, AC Supply , ISI marked complete
S&F modular type switch 6 A, 230V, AC Supply , ISI marked complete
S&F modular type Socket 16 A, 230V, AC Supply , ISI marked complete
S&F modular type Socket 6 A, 230V, AC Supply , ISI marked complete
S&F modular fan step type regulator two module
S&F Ceiling rose ,3pin, 5amps ISI marked , 230V, AC Supply , ISI marked complete
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit along with 1 No. 4 sq. mm FRLS PVCinsulated copper conductor single core cable for loop earthingas required. outlet. 15 amps, independent:-
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, with in built sensor based smart LED auto dimmable batten, made form power coated extruded aluminium housing, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
Supply & fix ceiling fans complete with blades down rods electronic regulator and accessories , 230 volts single phase 1200 mm sweep min air delivery 210 CFM with service value complete all as specified and directed.
Earthing complete with GI earth plate electrode 600x600x6mm buried directly in ground vertically to a depth of not less than 2.7mtr below ground level than 1.5mtr below ground level connected to GI 4mm wire by means of bolts washers etc made out of GI earth strip will be protected by galvanized iron pipe medium grade 15mm bore up to main distribution board/main switch including necessary excavation and earth work PCC 1:3:6 type CI (using 20mm graded stone aggregate) RCC cover 1:2:4 type B1 including necessary reinforcement etc complete all as show electric plate No.3 of MES Such Part-I.,
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required up to 35 Sqmm
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size:-
2 core x 10 Sqmm (from Prop Xmer to prop LT panel )
S&F MCB SPN 240 Volts 32 Amps complete
S&F MCB SP 240 Volts 6 to 32 Amps complete
PROVISION OF CHAIN LINK FENCING,RAIN WATER PIPE & OTHER CONNECTED WORKS IN BUILDING No. 08 & 17 OF DMRL, HYDERABAD. (B/R)Portion)
Excavating post holes upto 0.10 cum, including getting out the excavated soil, then returning the soil as deported in layers not exceeding 20cm in depth, including consolidating and deposited layer by ramming watering etc disposing of surplus excavated soil as directed with in a lead of 50m and lift upto 1.5m in all kind of soil
M&L plain cement concrete type B-2, 1:2:4 ( 40mm graded aggregate ) as in foundations, filling and mass concrete complete
Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc as required in frames, guard bars, ladders, railing, brackets gates and similar work
Providing and fixing mild steel bolts incluidng nuts and washers complete
Providing and fixing angle iron frames for doors, windows and gate of mild steel angle sections of size 50 x 50 x 6mm , joints mitred and welded by angle iron 40 x 40 x 5mm or 40x6mm flat pieces to the existing T- iron frame or to the wall with dash fasteners incluindg fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer all complete as per the direction of Engr-in-Charge
S & F chain link fencing of any type n exc 3.0 kg per Sqm including line wires, any mesh, size and type of standards, rails, straining bolts, etc., including provision of binding wire.
Painting on new steel surface ( two or more coats ) including a coat of approved steel primer ( red oxide primer) with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
Demolishing cement concrete manually / by mechanical means including disposal of materials within 50 metres as per direction of Engr -in- Charge (i) Nominal concrete 1:3:6 or richer mix ( i/c equivalent design mix )
Cement concrete 1:2:4 ( 1 cement ; 2 coarse sand : 4graded stone aggregte 40mm nominal size ) in pavements, laid in required slope and camber in panels as required incluidng consolidation finishng and tamping complete
M&L for rendering 10mm in CM 1:3 over concrete surfaces on RCC roof slab and parapets mixed with WPC @ 3% by weight of cement shall be carried out complete all as specified and directed by Engr-in-Charge. Note : WPC will be measured under separate item of this schedule.
Supply only integral water proofing compound Make :- SCOTT AQUA PROF/Dr. Fixit / Impermo / Cico
Providing and laying APP ( Atactic Polypropylene Polymer ) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non woven polyester matt weight not less than 3.50 kg / sqm consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/ Sqm by the same membrane manufacture of density at 25 C, 0.87 -0.89 Kg/litre and viscocity 70- 160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc and preparing the surface complete. the vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23 C as 650 /450N/5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. softening point of membrane not less than 150C. cold flexibility shall be upto - 2 C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrance. Note:- Approval of authorised applicator shall be obtained from accepting officer before commencement of work
Providing and fixing on wall face 110mm diameter unplasticised Rigid PVC rain water pipes conforming to IS : 13592 type 'A' including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion single socketed pipes complete
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type 'A' incluidng jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion bend 87.5 110mm bend
Demolition R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable materials within 50 metres lead as per direction of Engineer -in- Charge
PROVISION OF CHAIN LINK FENCING,RAIN WATER PIPE & OTHER CONNECTED WORKS IN BUILDING No. 08 & 17 OF DMRL, HYDERABAD. (E/M)Portion)
Supply and install 2 Ton inverter type,5 Star rated AC's with Low Gas Indication, Clean filter Indication, Automatic installation check and turbo cool with Auto cut -off feature complete all as directed. Make: Blue Star / carrier / Hitachi
Supply and fix Voltage stabilizer copper wound for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5KVA
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required for 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
S&F in walls/roofs PVC Pipe 20 mm heavy duty for Condensing water line including making provision for fixing.
S&F in walls/roofs PVC Pipe 20 mm heavy duty for Condensing water line including making provision for fixing.
M&L for insulation only to copper tubing of split type AC of cap 1.5 TR/2.0 TR with heavy duty rubber foam insulation as per existing density and thermal conductivity including packing material, reflector tape and pvc tie complete all as specified and directed. Make- Arm flex / Aero flex / Thermo break
S&F in replacement of flexible type water drain out pipe suitable for indoor unit of split AC as per existing type/model complete all as specified and directed.
Supply only in replacement Copper pipes 1/4 to 1/2" dia, duly insulated with synthetic felt tube, for split / window type Air conditioner / refrigerator / water cooler complete with taking out old unserviceable one
All as per item No.163 above but of size 3/8 to 5/8" dia
Supply only in replacement Brass flair nuts 1/2 to1/4" including taking out old unserviceable one.
All as per item No. 165 above but of size 3/8 to 5/8" dia
Supply and fixing of 2 AC Timer Change over switch for ACs installed at server /equipment room complete all as specified and as directed. Make : Dynamic, Model DIGI 2017
PVC insulated 3 core round flexible copper cable 1100 v grade of size 4.0 sqmm Make:- Plaza/Polycab/Havells/Finolex
PVC insulated 3 core round flexible copper cable 1100 v grade of size 2.5 sqmm Make:- Plaza/Polycab/Havells/Finolex
Anjana corporation
sanjar enterprises
S Anjan Reddy
Venkat Sai Enterprises
MVS ENTERPRISES
SUN LIGHT HOUSE
SRI SAI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .