Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹1.7 CrQualified Make: HNE HI PRESS
Model: HNE VARIO 9 CARBON 482 SIR GANGA RAM HOSPITAL SQUARE SHANKAR ROAD CENTRAL DELHI DELHI 110060 | CENTRAL DELHI | DELHI | 110060 | Make: HNE HI PRESS
Model: HNE VARIO 9 CARBON | ₹1.7 Cr | L2 | Qualified |
| 2 | L3₹1.7 CrQualified Make: ORBIT
Model: Make ORBIT Model Orbit-High Performance 9L-E CB 123 MIDC HINGNA NAGPUR MAHARASHTRA 440016 | NAGPUR | MAHARASHTRA | 440016 | Make: ORBIT
Model: Make ORBIT Model Orbit-High Performance 9L-E CB | ₹1.7 Cr | L3 | Qualified MSE |
| 3 | Qualified Make: ASKA
Model: ASKA HIPRESS 9 CARBON-E C 19 20 21 DEV BHOOMI INDUSTRIAL ESTATE PUHANA IQBALPUR ROAD BANTAKHEDI ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | Make: ASKA
Model: ASKA HIPRESS 9 CARBON-E | - | - | Qualified MSE |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
20 Aug 2018, 2:00 pmClosed
watermist and caf fire extinguisher high pressure back pack type Watermist And Caf Fire Extinguisher High Pressure Back Pack Type ( 49 ) Technical Specifications Specification Specification Name Values Allowed Values Genric "Conformity to EN 3-7:2004+A1:2007-0 8 standards " The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 30 clauses (3.2
3.15
4.2
4.3
4.4
4.5
6.1
6.2
6.3
7.1.1
7.1.2
7.2
7.3
7.4
8.1
8.2
9.2
10.1
10.2
10.3
10.4
10.5
10.6.1 & 10.6.2
14.1
14.2
15.2
15.3
16.1
16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily applicable for the complete system The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 30 clauses (3.2
16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily applicable for the complete system Mounting type Backpack - Configuration ( Shall be mounted on a sturdy frame suitably cushioned for comfort
provided with shoulder pads for carrying as a Yes - 1/6 backpack and a handle to be carried by hand. All materials used shall be of fire retardant type. Backpack shall be supplied with two air cylinders.) Model Number as per Accredited Laboratory Test Report to Be declared ASKA HIPRESS 9 CARBON-E - Main Components: Pressure vessel to hold the media with safety valve
compressed air cylinder coupled with a reducer
hose pipes for discharge of water mist media
extinguishing gun. Yes - Constructional Air Cylinder Material Ultralight Carbon composite with PET Liner Ultralight Carbon composite with PET Liner Type of Foam Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55
B233
Spreading coefficient for special AFFF Compound shall be +5 minimum
concentration shall be 6%. Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55
concentration shall be 6%. If special foam mention the composition for special
otherwise put NA Water 96%
1
2-Ethandiol
Fluorinated surfactant < 0.5%
Octylsulfate< 1%
Decylsulfate<1%
Akylpolyglycoside<1% - Commercial Brand Name of the Special foam (fire extinguishing medium) as per accredited laboratory test report wherein higher fire ratings i.e A55
E1000 V (Die Electric Suitability) achieved
to be declared.Write NA if not applicable. ASKA 63A - Characteristics of extinguishing medium Density 1.04 (kg/dm3)
Viscosity 1.35(mm2/s)
2/6 of Special AFFF Compound (manufacturer own specifications) with infrared spectrogram to be furnished.NA if not applicable pH factor 7.8
Refractive index 1.34 at 20 ± 2deg C Pressure Vessel Material & Capacity (Nominal Charge) Ultralite Carbon Composite with PET Liner of 9 liter capacity Ultralite Carbon Composite with PET Liner of 9 liter capacity Minimum wall thickness of pressure vessel (mm) 5 - Extinguishing gun material Stainless Steel - if others Mentions the material for Extinguishing gun
otherwise put NA NA - Extinguishing gun weight (750 grams approx) 750 - Length of EN marked Hose 1.3 meter for backpack system Yes - Weight of fully charged Backpack system between 25kg to 27kg having Corrosion Free Aluminum Alloy vessel and below 20 kg having Ultralite Carbon Composite with PET Liner Vessel for 20 - performance Air Cylinder Capacity (Ltrs) 2 - Air Cylinder pressure (Bar) 300 - High Pressure Type (Dynamic Operating pressure to be tested in the accredited laboratory test report which will be considered as high pressure for as per clause No. 3.15 of EN 3 - 7:2004 + Al: 2007-08 (E) Standard.) ≥ 30 for Aluminium vessel
≥ 35 for Ultralight Carbon composite with PET 37 - 3/6 Liner vessel (Bar) Lancing Distance of Gun : More than 12 meter (meter) 15 - The air hoses shall be suitable for minus 40 deg C to 100 Deg C temperature and EN mark on hose Yes - Minimum operating time in full throttle for aluminium alloy vessel NA - Minimum operating time in full throttle for Ultralight Carbon composite with PET Liner vessel 29 - System shall be designed for maximum operating temperature TS max and minimum operating temperature TS min of 60 deg C or more and 5 Deg C or less respectively and certified by the manufacturer accordingly as per Clause 7.4 of EN 3-7:2004+A1:2007-08 standards as per the accredited test report for backpack system. Yes - Fire Rating 55 A
233B
1000V with Special AFFF Compound as per manufacturer own specn 55 A
1000V with Special AFFF Compound as per manufacturer own specn Certification PED approval as per Directive 97/23/EC Yes - Pressure Vessel shall include a pressure gauge fitted on the vessel (CE Marked from notified body). Yes - No objection certificate (NOC) for Pressure Vessel from Petroleum and Explosives Safety Organization (PESO) Nagpur Yes - Pressure Vessel should Yes - 4/6 have CE Marking from Notified body The air cylinders shall have PESO
Nagpur approval yes - Specific consent of the OEM for the value additions made along with a confirmation that fire ratings of the equipment would not be affected by these value additions. Yes - Test Report No - - Test Report Date - - Name of ILAC/NABL/Central Govt.Accredited Laboratory where Test Conducted - - NOC Letter No. Date of PESO Nagpur for Pressure Vessel - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Abhishesh Rawat 110003
Safdarjung Airport 49 60
411429
GEM/2018/B/58215
watermist and caf fire extinguisher high pressure back pack type
60 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| watermist and caf fire extinguisher high pressure back pack type Watermist And Caf Fire Extinguisher High Pressure Back Pack Type ( 49 ) Technical Specifications Specification Specification Name Values Allowed Values Genric "Conformity to EN 3-7:2004+A1:2007-0 8 standards " The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 30 clauses (3.2 | - | - | - |
| 3.15 | - | - | - |
| 4.2 | - | - | - |
| 4.3 | - | - | - |
| 4.4 | - | - | - |
| 4.5 | - | - | - |
| 6.1 | - | - | - |
| 6.2 | - | - | - |
| 6.3 | - | - | - |
| 7.1.1 | - | - | - |
| 7.1.2 | - | - | - |
| 7.2 | - | - | - |
| 7.3 | - | - | - |
| 7.4 | - | - | - |
| 8.1 | - | - | - |
| 8.2 | - | - | - |
| 9.2 | - | - | - |
| 10.1 | - | - | - |
| 10.2 | - | - | - |
| 10.3 | - | - | - |
| 10.4 | - | - | - |
| 10.5 | - | - | - |
| 10.6.1 & 10.6.2 | - | - | - |
| 14.1 | - | - | - |
| 14.2 | - | - | - |
| 15.2 | - | - | - |
| 15.3 | - | - | - |
| 16.1 | - | - | - |
| 16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily applicable for the complete system The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 30 clauses (3.2 | - | - | - |
| 16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily applicable for the complete system Mounting type Backpack - Configuration ( Shall be mounted on a sturdy frame suitably cushioned for comfort | - | - | - |
| provided with shoulder pads for carrying as a Yes - 1/6 backpack and a handle to be carried by hand. All materials used shall be of fire retardant type. Backpack shall be supplied with two air cylinders.) Model Number as per Accredited Laboratory Test Report to Be declared ASKA HIPRESS 9 CARBON-E - Main Components: Pressure vessel to hold the media with safety valve | - | - | - |
| compressed air cylinder coupled with a reducer | - | - | - |
| hose pipes for discharge of water mist media | - | - | - |
| extinguishing gun. Yes - Constructional Air Cylinder Material Ultralight Carbon composite with PET Liner Ultralight Carbon composite with PET Liner Type of Foam Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55 | - | - | - |
| B233 | - | - | - |
| Spreading coefficient for special AFFF Compound shall be +5 minimum | - | - | - |
| concentration shall be 6%. Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55 | - | - | - |
| concentration shall be 6%. If special foam mention the composition for special | - | - | - |
| otherwise put NA Water 96% | - | - | - |
| 1 | - | - | - |
| 2-Ethandiol | - | - | - |
| Fluorinated surfactant < 0.5% | - | - | - |
| Octylsulfate< 1% | - | - | - |
| Decylsulfate<1% | - | - | - |
| Akylpolyglycoside<1% - Commercial Brand Name of the Special foam (fire extinguishing medium) as per accredited laboratory test report wherein higher fire ratings i.e A55 | - | - | - |
| E1000 V (Die Electric Suitability) achieved | - | - | - |
| to be declared.Write NA if not applicable. ASKA 63A - Characteristics of extinguishing medium Density 1.04 (kg/dm3) | - | - | - |
| Viscosity 1.35(mm2/s) | - | - | - |
| 2/6 of Special AFFF Compound (manufacturer own specifications) with infrared spectrogram to be furnished.NA if not applicable pH factor 7.8 | - | - | - |
| Refractive index 1.34 at 20 ± 2deg C Pressure Vessel Material & Capacity (Nominal Charge) Ultralite Carbon Composite with PET Liner of 9 liter capacity Ultralite Carbon Composite with PET Liner of 9 liter capacity Minimum wall thickness of pressure vessel (mm) 5 - Extinguishing gun material Stainless Steel - if others Mentions the material for Extinguishing gun | - | - | - |
| otherwise put NA NA - Extinguishing gun weight (750 grams approx) 750 - Length of EN marked Hose 1.3 meter for backpack system Yes - Weight of fully charged Backpack system between 25kg to 27kg having Corrosion Free Aluminum Alloy vessel and below 20 kg having Ultralite Carbon Composite with PET Liner Vessel for 20 - performance Air Cylinder Capacity (Ltrs) 2 - Air Cylinder pressure (Bar) 300 - High Pressure Type (Dynamic Operating pressure to be tested in the accredited laboratory test report which will be considered as high pressure for as per clause No. 3.15 of EN 3 - 7:2004 + Al: 2007-08 (E) Standard.) ≥ 30 for Aluminium vessel | - | - | - |
| ≥ 35 for Ultralight Carbon composite with PET 37 - 3/6 Liner vessel (Bar) Lancing Distance of Gun : More than 12 meter (meter) 15 - The air hoses shall be suitable for minus 40 deg C to 100 Deg C temperature and EN mark on hose Yes - Minimum operating time in full throttle for aluminium alloy vessel NA - Minimum operating time in full throttle for Ultralight Carbon composite with PET Liner vessel 29 - System shall be designed for maximum operating temperature TS max and minimum operating temperature TS min of 60 deg C or more and 5 Deg C or less respectively and certified by the manufacturer accordingly as per Clause 7.4 of EN 3-7:2004+A1:2007-08 standards as per the accredited test report for backpack system. Yes - Fire Rating 55 A | - | - | - |
| 233B | - | - | - |
| 1000V with Special AFFF Compound as per manufacturer own specn 55 A | - | - | - |
| 1000V with Special AFFF Compound as per manufacturer own specn Certification PED approval as per Directive 97/23/EC Yes - Pressure Vessel shall include a pressure gauge fitted on the vessel (CE Marked from notified body). Yes - No objection certificate (NOC) for Pressure Vessel from Petroleum and Explosives Safety Organization (PESO) Nagpur Yes - Pressure Vessel should Yes - 4/6 have CE Marking from Notified body The air cylinders shall have PESO | - | - | - |
| Nagpur approval yes - Specific consent of the OEM for the value additions made along with a confirmation that fire ratings of the equipment would not be affected by these value additions. Yes - Test Report No - - Test Report Date - - Name of ILAC/NABL/Central Govt.Accredited Laboratory where Test Conducted - - NOC Letter No. Date of PESO Nagpur for Pressure Vessel - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Abhishesh Rawat 110003 | - | - | - |
| Safdarjung Airport 49 60 | - | - | - |
Exempted
20 Aug 2018
1 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_411429.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .