EE(E) C-II
O/o EE(E)C-II, 33 kV ESS, Netaji nagar, new Delhi
SITC of 11 kV VCB HT Panels, Battery Charger, Battery Bank, Earthing and Allied works for proposed Electric sub-station at ICPS Building, 3 Nyaya Marg, New Delhi
2025_NDMC_282734_1
NIT No. 07/2025-26/EE (C-II) E
Open Tender
Electrical Works
Percentage
Nyay Marg
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.8 L
Yes
Palika kendra
26 Feb 2026
19 Dec 2025
20 Jan 2026
19 Dec 2025
20 Jan 2026
19 Dec 2025
29 Dec 2025
Supply of 11kV, 630 A VCB switchgear panels for incomer feeder, as per Technical Specifications.
Supply of 11kV, 630 A VCB switchgear panels for Bus coupler with Bus riser, as per Technical Specifications.
Supply of 11kV, 630 A VCB switchgear panels for Outgoing feeder, as per Technical Specifications.
Cartage, Installation, Testing and Commissioning of 11 KV HT VCB Panel complete in all respect as per site requirement. [ I/C-02 Nos, O/G=04 Nos, B/C=01 No]
Supply, Installation, Testing and Commissioning of Maintenance free type Earth Grid as per specifications to deliver earth result not exceeding 02 Ohms, consisting earth electrode (s), Copper bonded Earth Strip and hardware for interconnection of earth electrodes, earth enhancing material (conductive concrete), complete in all respect.
Supply, installation, testing, and commissioning of real-time earthing measurement device to display earth pit resistance in ohms along with Local Alarm generation for threshold breach with provision of setting alarm values. The system should have Modbus RS485 port for provision of future SCADA integration & Communication.
Supply & fixing of copper bonded MS strip having size 50x6 mm for connection of earthing from earth grid to equipment, as per Technical Specification.
Providing & Fixing of 65 mm GI Pipe from earth grid to equipment (as required) including connection with nut, bolt, spring washer excavation and refilling as required, complete in all respect as per site requirement.
Supply, installation, Testing and commissioning of free standing, Dual Float Cum Boost Charger for Ni-Cd battery (partial Recombination Type) as per Technical Specification, complete in all respect as per site requirement. Input Voltage:230 V (1Ph AC) Output Nominal Voltage: 110 V DC, Capacity 60AH
Supply, installation, Testing and commissioning of Ni-Cd battery bank (partial Recombination Type) as per Technical Specification, complete in all respect as per site requirement. Nominal Voltage:110V Rating: 60AH
Providing and Fixing of synthetic insulating mat 2.5 mm thickness and 01 Mtr width suitable for 11 kV HT Panel board ISI marked having di-electric strength 45 kV, confirming to IS 15652(latest), complete in all respect as per site requirement.
Supplying and laying of ISI marked XLPE insulated, sheathed, armoured, copper conductor of size 2.5 sq.mm/10 C control cable for working voltage upto 1.1 kV in recess/on surface/in G.I. pipe/cable trays etc from energy meter box to HT panel complete in all respect as per site requirement. Make: Plaza/Havells/Finolex/RR Cable/KEI/Polycab
Supplying and laying of ISI marked PVC insulated ,sheathed, armoured, copper conductor of size 2.5 sq.mm/4 C control cable for working voltage upto 1.1 kV in recess/ on surface/ in G.I. pipe/cable trays etc from Battery Charger to HT panel, complete in all respect as per site requirement. Make: Plaza/Havells/Finolex/RR Cable/KEI/Polycab
Providing and Fixing of Meter Box for 3 phase energy meter of suitable size along with Test Terminal Block (TTB) fabricated from 1.6 mm MS sheet duly powder coated including Providing and fixing Bakelite sheet of suitable size with locking arrangement, complete in all respect as per site requirement.
Supplying and Fixing Fire Extinguisher CO2 (4.5 Kg) complete in all respect as per site requirement.
Supplying and Fixing Fire Bucket complete in all respect as per site requirement.
Supplying and Fixing of First Aid Box complete in all respect as per site requirement.
Supplying & fixing of ESS Name Plate in 3mm ACP (Aluminium Composite Panel) sheet with pasting digital ECO Vinyl Paint reflective component of size 3 X 2 Feet along with Aluminium frame, complete in all respects as per the site requirement.
Supplying and Fixing of First Aid Chart/Shock treatment chart, laminated in wooden frame and complete in all respect as per site requirement.
Supplying and fixing of caution board (1x1 feet) complete in all respect as per site requirement.
Design, Supply & fixing of Single Line Diagram of ESS in Glass/Polycarbonate Frame of size (2 Feet X 2 Feet) on wall with nut bolts etc. with provision of removable Drawing sheet complete in all respect as per the site requirement
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.33 MB
NIT07.pdf
Tender Documents • 2.32 MB
BOQ_373700.xls
BOQ • 0.32 MB
SignedIP.pdf
PDF • 2.74 MB
DATE.pdf
PDF • 0.36 MB
Corri.pdf
PDF • 1.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .