Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC 282 SADAR BAZAR JHANSI 284001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹40.1 L+₹1.1 L (2.87%)Rejected-Finance WARD NO 4 NEAR MASZID BHATTAGAON DISTT JHANSI 284001 UTTAR PRADESH | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹40.8 L+₹1.8 L (4.74%)Rejected-Finance 00 BHUSAR FARM KE PASS K K PURI NANDANPURA JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹41.5 L+₹2.6 L (6.67%)Rejected-Finance | L4 | Rejected-Finance Not become lowest bidder |
Tender Value
Refer Docs
EMD Value
₹90,600
Closing Date
5 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Major Deepak Kumar
Garrison Engineer Jhansi
SPL REAIRS TO BLDG NO T-07 OTM ACCN OF 269 MED REGT (SP) UNDER GE JHANSI
2021_MES_473427_1
GE/JHA/TOK/46 OF 2021-2022
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender document
7 documents required · 7 mandatory
₹500
Yes
GE Jhansi
₹90,600
Yes
25 Nov 2021
7 Sept 2021
7 Oct 2021
7 Sept 2021
5 Oct 2021
21 Sept 2021
60 days
Amount
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar and removing rubbishes off the premises complete all as specified and directed.
Demolition cement concrete unreinforced in ground floor and paving n exc 15 cm thickness (below or above ground level) and removing rubbishes off the premises complete all as specified and directed.
Taking down cement or cement lime plaster any description including racking out joints, hacking for key, scrubbing down with water etc and removing rubbishes off the premises all as directed
Taking down chowkhats or frames with shutters (wihtout taking off shutters from the frame) exc. 1.5 sqm and nexc. 4 sqm.
Demolition of brickwork ,stone/boulder masonry, build in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete and removing rubbishes off the premisesall as specified and directed.
M&L brick work with fly ash lime bricks (FALB) conforming to IS 12894 size 230x110x75 mm, (strength M-10), straight or curved on plan to any radius in half brick thick walls built in cm (1:4) complete all as specified and directed.
M&L brick work with fly ash lime bricks (FALB) conforming to IS 12894 size 230x110x75 mm, (strength M-10), straight or curved on plan exc 6m mean radius built in cm (1:6) complete all as specified and directed.
Rendering 15mm thick on fair faces of brick work or concrete surface to be finished even and rough in CM 1:6 complete all as specified and direcetd.
Rendering 15mm thick on fair faces of brick work or concrete surface to be finished even and rough in CM 1:4 complete all as specified and direcetd.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets
M&L 200 long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
M&L 300mm long alluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
S&F 150mm brass handles, cast type, polished bright complete all as specified and directed
M&L for 25 thick PCC (1:2:4) in floors etc using 20mm graded aggregate .
M&L for vitrified ceramic coloured tiles, joint free, 10 mm thick ( square / rectangular) area of each tile exceeding 0.18 sqm but n. exc 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match and including over 15mm thick screed/ bedding layer in CM (1:6) complete all as specified and directed.
All as per item No 15 here-in-above but in skirting over and including 10 mm thick rendering in CM (1:4).
M&L for factory made polyurethane coated, chequered cement concrete tiles of any colour 30 cm x 30cm x 25 mm thick, set & jointed and pointed in neat cement slurry mixed with grey cement and pigments, over and including 15 mm thick bedding layer in CM (1:6) for receiving tiles, complete all as specified and directed by the Engineer in Charge.
M&L cement concrete 1:3:6 using 20mm graded stone aggregate as in floor.(Thickness as reqd at site)
Complete removal of existing treatment from wall and preparing the undecorated surface of wall and applying two coats of oil bound distemper with a coat of alkali resistent primer over a coat of chalk whiting all as specified.
Preparing new surface of wall and applying two coats of oil bound distemper with a coat of alkali resistent primer over a coat of chalk whiting all as specified.
S&F Fe 410-W (Gde E-250) quality A for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled holes for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also fastening and fixing complete all as specified and directed
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks, (stay) heavy for large gates, hook and plintle hinges,large hasps and staples, chains hand made sliding bolts, clamp, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar samll articles confirming to Fe-290 Gde-E-165 complete all as specified and directed
S&F of factory made 35 mm thick flush doors, solid core construction, with block board core and pre-lamination on both sides, complete all as specified and directed by Engineer in Charge.
S&F 2nd class hard wood 35mm thick Glazed and skelton shutters open reabted and prepared to receive glass/gauge etc (without sash bars), edges of framing plain,chamfered of rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters complete all as specified and directed
S&F 125mm size Butt hinges, medium weight, cold rolled mild steel and fixed.
S&F mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate complete.
S&F 150mm mild steel pressed handles, oval type stove enamelled black complete all as specified and directed
S&F Galvanised mild steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples.
S&F 300mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed
S&F 200mm length mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed
Preparation of new surfaces wooden of any description not other described over 10cm width or grith and applying two coat of synthetic enamel paint over a coat pink primer.
Preparation of new surfaces steel of any description not other described over 10 cm width or grith and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
M&L for complete removal of existing treatment by brushing, washing, rubbing down, scraping, watering and applying two coat of Cement base paint over and including one coat of cement based primer, complete all as specified and directed by the Engineer in Charge.
M&L for preparation of new plastered surface and applying two coat of cement base paint over and including one coat of cement based primer, complete all as specified and directed by the Engineer in Charge.
M&L Screed bed or bedding layer of mortar 20mm thick for laying floor finishes in cement mortar 1:6
M&L for Machine cut kota stone slab flooring 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
M&L for box type steel window with 80x40x1.25 mm MS tubular frame with side hung shutters (double shutter for glass and gauze) without sash bars jointed together with and including grill using 12 mm square bar @ 10 cm C/C including box type hinges with steel handle and steel peg stay complete glazing bars doweled and welded complete all as specified as directed. Note:- (a) The Glass / gauze shell be measured and paid separately. (b) Side hung Z-Section shutter shall be of size 20mm x 20mm x 25mm and 3 mm thick.
S&F of exposed frame false ceiling system with GI powder coated grid consisting of interlocking arrangement of main T runner of 15mm size, suspended at 1200mm c/c and cross T runner of 15mm size suspended at 600 mm c/c supported by 4mm dia GI wire from roof/slab/truss including wall/perimeter runner/channel of 15mm zise with and including 4mm thick pre-painted non asbestos fiber reinforced cement board (E-board), designer type of size 595x595mm, duly fixed in ceiling frame work, complete all as specified and directed
Dismantling of asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings
S&F Pre-Painted galvalume aluminium zinc coating GI based trapezoidal profile steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa of grade AZ-150 as in roof covering /cladding to wall fixed with self tapping screws as specified (Make- Everest/TATA/ Jindalsteel
S&F Pre-Painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa of grade AZ-150 as in roof covering /cladding to wall fixed with self tapping screws as specified (Make- Everest/TATA/ Jindalsteel
S&F rolled mild steel in roof trusses (framed) trussed purlins crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle channel or flat sections) incl distance pieces, cleats etc.
Dismantling timber scantling 40 sqm and over in section and any position in framed work , all as specified
S&F of 3mm thick sheet glass ordinary quality glazing with oil putty or beads in square n. exc 0.5 Sqm in each pane complete all as specified and directed by the Engineer in Charge.
S&F of 3mm thick figured glass, pin head type and glazing with oil putty in square n. exc 0.5 Sqm in each pane complete all as specified and directed by the Engineer in Charge.
M & L for 75 mm thick PCC 1:2:4 Type B2, using 40 mm graded aggregate as in plinth protection, laid in atternate panels not more than 3mtr in length laid to slope 1:30 including forming joints 10mm wide upto fall depth of PCC and filled with bitumen mastic (1:3), complete all as specified and directed by the Engineer in Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG, with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass /GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-
One light point controlled by one switch
One ceiling fan controlled by one switch and one regulator
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per srl item No.48 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
M&L for Circuit/submain wiring alongwith earth wire 2 runs x 6 sqmm + 1 run x 6 sqmm with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
All as per srl item No. 50 here-in-before but 2runsX4 Sqmm +1runX4Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
Notes for item No. 48.00 to 51.00 (i) Quoted rate shall deemed to incude the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & caping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing caping may be used in that portion. (iv) Make of conduit : AKG/Polycab/Kalinga/Precision/Modi/Atul (v) Make of Copper wires: Finolex/Polycab/Havells/V-Guard/KEI/Gloster
S&F, Switch piano type, single pole, one way, 6 amps, 240 volts, complete all as specified and directed. Make: :Havells(Reo) /Goldmedal /SSK /GM
S&F, Socket, two-in-one, 5 pin, 6 Amp, universal type, 240 volts, complete all as specified and directed. Make: :Havells(Reo) /Goldmedal /SSK /GM
S&F, Switch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed. Make: :Havells(Reo) /Goldmedal /SSK /GM
S&F, Socket, 6 pin, 6/16 Amp, multipurpose 240 volts, complete all as specified and directed. Make: :Havells(Reo) /Goldmedal /SSK /GM
S&F, angle holder, metal cased, bakelite body, 240 volts, complete all as specified and directed. Make: :Havells(Reo) /Goldmedal /SSK /GM
Supply and fix electronic fan regulator in 5 steps, 240V, 50Hz complete all as specified and directed. Make: :Havells(Reo) /Goldmedal /SSK /GM
S&F, Ceiling rose, three terminals, bakelite body, 240 volts, complete all as specified and directed.Make: :Havells(Reo) /Goldmedal /SSK /GM
S & F 7 W White LED retrofit lamp suitable for B-22 holder base with polycarbonate diffuser and aluminium heat sink. Make: :Havells(Reo) /Goldmedal /SSK /GM
Supply and fix LED batten box type with CRCA sheet steel body pre-wired suitable for and including provision of 1x20/22Watt (4 feet) retrofit LED tube with PC body and connecting up with twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge.Make: Havells / Bajaj / Wipro / Philips /Osram
Supply and fix LED building security light fitting 25 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP 65degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed by Engineer-in-Charge..Make: Havells / Bajaj / Wipro / Philips /Osram
S&F, in replacement of bulk head light fitting including 5W retrofit LED lamp and making all electric connections complete all as directed. .Make: Havells / Bajaj / Wipro / Philips /Osram
Supply and fix modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.
Supply and fix MCB distribution board, TPN, 4 way 415 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separetely.
All as per srl item No. 65 here-in-before but SPN 08 way,
S& F MCB TPN 63 Amp, 10 KA, 'C' curve, 430 V, 50 Hz
All as per srl item No. 67 here-in-before but SPN 40 Amp 230 Volt.
All as per srl item No. 67 here-in-before but 6 to 32 Amp, Single Pole 230 Volt.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed, 16 sq mm 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc including taking down existing service cable of any description complete all as specified and directed. Make: Havells /Polycab /Univarsal/Gloster/Asian Cable/RPG
M&L for High density polyethylene pipes (HDPE) 50mm dia of pressure rating 6 kgf/cm2 laid in trenches/floors/duct or fixed on walls /pole for cable protection complete all as specified and directed. Make: Finolex / Kisan / Prince / Tirupati /Supreme / Jain Irrigation Sys
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of cable and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
M&L for Tubes, 'Light grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors of 50 mm bore.
Supply and fix in replacement of customized Fan clamp made out of 3mm thick MS flat bent to required shape as per site requirement fixed with suitable size of number of nuts, bolts & washers etc suitable for fixing down rod including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan of any size carefully, sealing cable end, dismantling blades and removing fan and blades to store for servicing including supply, replacing bearings/bushings, capacitor and terminal connector including capacitor holder suitable for any model of existing fan, Painting of ceiling fans complete, with one coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc and Hanging ceiling fan in its existing or new location and connecting up including provision of 3core flexible copper conductor cable 0.5 sqmm from ceiling rose or connector to fan and testing for satisfactory functioning complete all as specified and directed by Engineer-in-Charge.
M/s JS Constructions
A K ENTERPRISES
M/S Kesav Dev Agarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .