Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid Value | |
| 2 | L2₹32.9 L+₹63,488 (1.97%)Rejected-AOC | L2 | Rejected-AOC Higher Bid Value | |
| 3 | L3₹33.8 L+₹1.5 L (4.62%)Rejected-AOC 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L3 | Rejected-AOC Higher Bid Value | |
| 4 | L4₹38.4 L+₹6.1 L (19.0%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L4 | Rejected-AOC Higher Bid Value | |
| 5 | L5₹45.5 L+₹13.2 L (40.8%)Rejected-AOC | L5 | Rejected-AOC Higher Bid Value |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
19 Jun 2021, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
REPAIR/REPLACEMENT INCL REWIRING OF DEFECTIVE WIRING, REPLACEMENT OF MCBs, DBs, SWITHCES/SOCKET AND CONNECTED WORKS AT POCKET I / II AND REPAIR/REWINDING OF CEILING/EXHAUST/WALL MOUNTED FANS AND GEYSERS INCL SPARES, OILING, GREASING AND PAINTING
2021_MES_444774_1
8793/GE/33
Open Tender
Civil Works
Item Rate
270 days
CH (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
Yes
GE (AF) BANGALORE
₹84,000
Yes
7 Sept 2021
21 May 2021
21 Jun 2021
21 May 2021
19 Jun 2021
7 Jun 2021
22 May 2021 - 31 May 2021
Amount
Taking down carefully existing unserviceable point wiring with copper/ aluminium conductor cables (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendants, regulators, sockets but excluding light fittings complete and removing retrieved materials and making good the disturbed surfaces of wall, floor ceiling etc., complete all as specified and as directed.
Point wiring complete with 1100 volts grade single core, PVC insulated FRLS cable with multi-stranded copper conductor of size 1.5 sq mm nominal area, passing through heavy grade PVC casing casing 'N' capping/ PVC conduit of suitable size, with all necessary fittings on wall/ roof surfaces, duly earthed with one run of single core PVC insulated FRLS cable with multy stranded copper conductor of size 1.5 sqmm nominal area green in colour as continues earthing wire connected to common earth dolly including 1.6 mm thick fabricated CI/MS sheet terminal box concealed mounting in the wall for mounting switches,switch socket combination, fan regulators etc.covered with 3mm thick electroplated hylam sheet top cover for housing switches, sockets, regulators etc. complete for one light/ fan point controlled by one single pole 5 amps switch/socket including 1 run of 1.5 Sqmm green colour copper cable as continuous earth wire, complete all as specified and directed.
(a)One light point controlled by one single pole 5 Amps switch
(b)One fan point controlled by one single pole 5 Amps switch and regulator
(c )One light points controlled by two Nos of two way 5 Amps switch
(d)One switch socket out let point 5 Amps on independent board
(e)One switch socket out let point 5 Amps on same board with other switches
(f)One bell point controlled by one bell push
Point wiring complete with 1100 volts grade single core, PVC insulated FRLS cable with multi-stranded copper conductor of size 1.5 sq mm nominal area, passing through existing PVC casing casing 'N' capping/ PVC conduit on wall/ roof surfaces, duly earthed with one run of single core PVC insulated FRLS cable with multi stranded copper conductor of size 1.5 sqmm nominal area green in colour as continues earthing wire connected to common earth dolly complete using existing switches,switch socket combination, fan regulators etc for one light/ fan point controlled by one single pole 5 amps switch/socket, complete all as specified and as directed.
(a)One light point controlled by one single pole 5 Amps switch
(b)One fan point controlled by one single pole 5 Amps switch and regulator
(c )One switch socket out let point 5 Amps on independent board
(d)One switch socket out let point 5 Amps on same board with other switches
Point wiring complete with 1100 volts grade single core, PVC insulated FRLS cable with multi-stranded copper conductor of size 2.5 sq mm nominal area, passing through heavy grade PVC casing casing 'N' capping/ PVC conduit of suitable size, with all necessary fittings on wall/ roof surfaces, duly earthed with one run of single core PVC insulated FRLS cable with multy stranded copper conductor of size 1.5 sqmm nominal area green in colour as continues earthing wire connected to common earth dolly including 1.6 mm thick fabricated CI/MS sheet terminal box concealed mounting in the wall , covered with 3mm thick electroplated hylam sheet top cover for housing 15 A switches, 15A sockets including 1 run of 2.5 Sqmm green colour copper cable as continuous earth wire, complete all as specified and directed.
Piano type switch single pole 5 Amps one way 230 volts, complete all as specified and directed
Piano type switch single pole 5 Amps two way 230 volts, complete all as specified and directed
Bell push 5 amps ,230 volts, complete all as specified and directed
Socket outlet 5pin multi purpose 5 Amps flush type, complete all as specified and directed
Socket outlet 5 pin multi purpose 5/15 Amps flush type, complete all as specified and directed
Switch 15A flush type universal pattern 230 v, complete all as specified and directed
PVC ceiling rose 65 x 50 mm surface type with 3 terminals, complete all as specified and directed
Electronic fan regulator socketed step type upto 100 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm, fixed as in repairs, complete all as specified and directed. Make : Anchor/Crompton greevs
Calling bell 230 v single pole fancy type Ding Dong Bell, fixed as in repairs, complete all as specified and directed
LED lamp Adore 10W B22 Cdl Ball Lamp type 6500K, fixed as in repairs, complete all as specified and directed Make- Havells/CG/Bajaj/Philips
Switch socket combination outlet 5 A , 5 pin Flush type, fixed as in repairs, complete all as specified and directed
Socket combination outlet multipurpose 2 in 1 , 5/15 A Flush type, fixed as in repairs, complete all as specified and directed
Straight/angle holder AC 230V, fixed as in repairs, complete all as specified and directed
LED tuberod 20W Glass type with single/double side connection including necessary connection suitable for tuberod, fixed as in repairs, complete all as specified and directed. Make-Havells CRYSTAL1213T8DSTL20WLED865SGLASS equivalent model in CROMPTON/PHILIPS/WIPRO/BAJAJ.
LED tuberod batten with internaly pre-wired, fixed as in repairs, complete all as specified and directed. Make-Havells equivalent model in CROMPTON/ PHILIPS/WIPRO/BAJAJ.
LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, fixed as in repairs, complete all as specified and directed.
LED light fitting, 36 watt 4'x1" , 230v recessed & surface LED 1X4 Flat Panel ceiling light with high performance, commercial grade solution suitable for hospitals including connecting up with twin core flexible copper conductor cable with suitable size, fixed as in repairs, complete all as specified and directed
LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, fixed as in repairs, complete all as specified and directed.
LED lights fitting 1x 22W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, fixed as in repairs, complete all as specified and directed.
LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, fixed as in repairs, complete all as specified and directed.
LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed as in repairs, complete all as specified and directed.
Suspension LED light fitting, 36watt classic styling with cutting edge technology to provide quality illumination and superior optical control. Use of direct/ indirect LED light engines makes it excellent choice for low heightceiling applications and areas where ceiling uniformity and indirect lighting is important (secondarysuspension kit included). including connecting up with twin core flexible copper conductor cable, fixed as in repairs, complete all as specified and directed. Make: Havells Model LICONLP36WLED857SPCGRY or equivalent model in CROMPTON/PHILIPS/WIPRO/BAJAJ.
Round shape 15 watt 220 volts AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, fixed as in repairs, complete all as specified and directed.
Sub main wiring with Two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 10 sqmm in and including heavy grade PVC casing and capping/PVC conduit and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 10 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly, fixed as in repairs, complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
All as per serial item No 28 above but for 2x6 sqmmsqmm copper conductor cable 6 sqmm pvc insulated unsheathed copper earth continuity conductor, fixed as in repairs, complete all as specified and directed.
All as per serial item No 28 above but for 2x4 sqmm copper conductor cable 4 sqmm pvc insulated unsheathed copper earth continuity conductor, fixed as in repairs, complete all as specified and directed.
Sub main wiring with four single core PVC insulated cable with copper conductor multistranded 1100 volts grade 6.0sqmm in and including heavy grade PVC casing and capping/PVC conduit and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly, fixed as in repairs, complete all as specified and directed. Note : One run of earth continuity conductor and four run of copper conductor together taken as one length for measuring unit length.
Sub main wiring with four single core PVC insulated cable with copper conductor multistranded 1100 volts grade 10.0sqmm in and including heavy grade PVC casing and capping/PVC conduit and its accessories with fixing arrangements on surface, wall, floor or ceiling etc including 10 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly, fixed as in repairs, complete all as specified and directed. Note : One run of earth continuity conductorand four run of copper conductor together taken as one length for measuring unit length.
Sheet metal enclosure MCB DB double door type 230v with 4 ways SPN suitable bus bar model, fixed as in repairs, complete all as specified and directed.
Sheet metal enclosure MCB DB double door type 230v with 8 ways SPN suitable bus bar model , fixed as in repairs, complete all as specified and directed.
Sheet metal enclosure MCB DB double door type 230v with 12 ways SPN suitable bus bar model, fixed as in repairs, complete all as specified and directed.
Sheet metal enclosure MCB DB double door type 230v with 4 ways TPN suitable bus bar model, fixed as in repairs, complete all as specified and directed.
Sheet metal enclosure MCB DB double door type 230v with 6 ways TPN suitable bus bar model, fixed as in repairs, complete all as specified and directed.
MCCB 125 Amps fixed thermal fixed magnetic setting, 430 volts, 10KA, 4 pole, fixed as in repairs, complete all as specified and directed.
MCCB 100 Amps fixed thermal fixed magnetic setting, 430 volts, 10KA, 4 pole, fixed as in repairs, complete all as specified and directed.
MCCB 63 Amps fixed thermal fixed magnetic setting, 430 volts, 10KA, 4 pole, fixed as in repairs, complete all as specified and directed.
MCB SP of 05 to 32A,'C' curve, 10KA rupturing capacity, fixed as in repairs, complete all as specified and directed.
MCB SPN of 05 to 32A,'C' curve, 10KA rupturing capacity, fixed as in repairs, complete all as specified and directed.
MCB SPN of 40 to 63A,'C' curve, 10KA rupturing capacity, fixed as in repairs, complete all as specified and directed.
MCB TPN of 63A,'C' curve, 10KA rupturing capacity, fixed as in repairs, complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole 20A MCB ,C curve , 10KA with metal clad top, fixed as in repairs, complete all as specified and directed.
PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable of size 6 Sqmm 1100v grade, fixed as in repairs, complete all as specified and directed.
PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core cable of size 4 Sqmm 1100v grade, fixed as in repairs, complete all as specified and directed.
Taking down the ceiling fans 1200/1400mm at site of any make and servicing of ceiling fan complete with greasing incl refixing the same after servicing checking properly by removing and replaced the unsv parts nut bolts, split pins rubber wheel,necessary threading for rods etc.re-connecting the fans to ceiling rose/connector complete with 23 / 0.0076 " flexible twin core copper conductor cable from fan to ceiling rose/connector (spare parts to be obtained from relevant items) and re-assembling the same with proper accessories and testing, complete all specified and directed.
Taking down the exhaust fans 300/380/450 mm at site of any make and servicing of exhaust fan complete with greasing refixing the same after servicing checking properly by removing and replaced the unserviceable parts nut bolts, pins rubber bushes etc.re-connecting the fans to ceiling rose/connector complete with 23 / 0.0076 " flexible twin core copper conductor cable from fan to ceiling rose/connector (spare parts to be obtained from relevant items) and re-assembling the same with proper accessories and testing, complete all as specified and directed.
Taking down the wall mounted fan at site of any make and servicing of wall mounting fan complete with greasing refixing the same after servicing checking properly by removing and replaced the unserviceable parts nut bolts, split pins etc.re-connecting the fans to ceiling rose/connector complete with 23 / 0.0076 " flexible twin core copper conductor cable from fan to ceiling rose/connector (spare parts to be obtained from relevant items) and re-assembling the same with proper accessories and testing, complete all as specified and directed.
Ball bearing in replacement as per existing for ceing fan/exhaust fan/wall mounted fan, complete all as specified and directed.
Rubber reel insulator of suitable size for ceiling fan with necessary clamp and nut & bolt, complete all as specified and directed.
Capacitor of cap 2.5 MFD, complete all as specified and directed. Make Havells Cat No:QHPCWC5002X5 description 2.5 MFD/440V/PLWW/28X52 or equivalent make CG
Capacitor of cap 3.15 MFD, complete all as specified and directed. Make Havells Cat No :QHPCWC5003X1 description 3.15 MFD/440V/PLWW/28X52 or equivalent make CG
Capacitor of cap 4 MFD, complete all as specified and directed. Make Havells Cat No :QHPCWC5004X0 description 4 MFD/440V/PLWW/28X52 or equivalent make CG
Gun metal bush of size suitable for ceiling fan shaft, complete all as specified and directed.
Rewinding of ceiling fan with super enamel copper wire as per existing size/gauge to achieve the required RPM as per manufacturers design including proper heating varnishing and provision of insulating etc and testing, complete all as specified and directed.
(a) Ceiling fan of size 1200mm sweep
(b) Ceiling fan of size 1400mm sweep
Fan hook on RCC ceiling made by MS plate iron of size 40 x 5 mm and 66 cm length incl no nut bolt with washer of size, fixed as in repairs, complete all as specified and directed.
Rewinding of exhaust fan with super enamel copper wire as per existing size/gauge to achieve the required RPM as per manufacturers design including proper heating varnishing and provision of insulating etc and testing, complete all as specified and directed.
(a) Exhaust fan of size 300mm to 380mm sweep
(b) Exhaust fan of size 400mm to 450mm sweep
Rewinding of wall mounting fan with super enamel copper wire as per existing size/gauge to achieve the required RPM as per manufacturers design including proper heating varnishing and provision of insulating etc and testing, complete all as specified and directed.
(a) wall mounting fan of size 400mm sweep
(b) wall mounting fan of size 450mm sweep
Exhaust fan blade suitable for 450 mm, fixed as in repairs, complete all as specified and directed.
Exhaust fan blade suitable for 300 to 380mm, fixed as in repairs, complete all as specified and directed.
Ceiling fan blade for 1200mm sweep, fixed as in repairs, complete all as specified and directed.
Ceiling fan blade for 1400mm sweep, fixed as in repairs, complete all as specified and directed.
Fan blade for wall mounting fan 400/450mm, fixed as in repairs, complete all as specified and directed.
Spray painting after necessary preparation of surfaces of ceiling fans of any size make complete set by using emery paper and wire brush etc and painting with one coat of synthetic enamel paint including rewriting of MES Number etc., complete all as specified and directed.
Detecting faults at site of ceing fan,exhaust fan,wall mounting fan any type and make in CHAF area under AGE EM CHAF and rectifiying the defects and make functional including replacing of unserviceable defective electrical/spares accessories, complete all as specified and directed. Note :- (i) Rate for any item shall be measured and paid under respective item of schedule (ii) Essential material like, insulation tape,screws and all tools required for carrying out the works and instruments to the detect fault shall be deemed to be included in the quoted rate (iii) The work is of day to day maintenace, required Electricians and Helper has to be attend daily for carryout the above work.
Taking Down and Refixing incl Painting of water heaters (Geysers) of following capacity of any make/model in site with synthetic enamel paint by brush including filling of cavities with fillers one coat after cleaning all dust etc including writing MES numbers etc., complete all as specified and directed for following :-
(a) Water heater 25 litres capacity.
(b) Water heater 50 litres capacity.
(c ) Water heater 80 litres capacity.
Dismantling following unserviceable items/parts from water heaters of any capacity/make/model, supply and fix inreplacement with new items/parts of same capacity/type/model, connecting up and testing, complete all as specified and directed :-
(a)Heating element 1.5 KW capacity AC 230 V and conforming to IS specifications screw/flange type.
(b)Heating element 2.0 KW capacity AC 230 V and conforming to IS specifications screw/flange type.
(c )Thermostat suitable for water heater upto 80 litres capacity.
(d)Indicator lamp any type (red/green)suitable for water heaters upto 80 litres capacity.
(e) Non return valve 15 mm dia size.
(f) PVC connection 15mm size with PTMT nuts of length 300mm for hot water supply.
(g) PVC connection 15mm size with PTMT nuts of length 300mm for cold water supply.
(h) Rubber gasket flat/'O' ring type suitable for water heater
(j)PVC insulated and FR PVC Round Sheathed, Copper Conductor(flexible) industrial cable, 1100 Volts 3 core flexible copper conductor cable of size 2.5 sqmm
(k) Plug top 3 pin 15 amps all as directed..
(l)Pressure release safety valve suitable for geysers upto 80 litres capacity. all as directed.
Old rusted /worn out MS bolts and nuts and grouting 4 nos new MS "T" bolts and nuts in brick walls ( MS bolt size 3/8 " x 6" with washers ) and making good the disturbed surfaces incl plastering , curing etc., fixed as in repairs, complete all as specified and directed.
Geysers from building and taking out the inner container(copper) and repairing the cracks by soldering /gas welding/Tinkering and reassembling the inner container, sealing the gap and refixing in same position of the building and testing, fixed as in repairs, complete all as specified and directed.
Filling with compact packing of glass wool of suitable thickness for water heater of following capacity, complete all as specified and directed.
(a) Water heater 25 litres capacity.
(b) Water heater 50 litres capacity.
Bottom assembly apparatus plate of copper for water heater of following capacity suitable to accommodate Thermostat, Heating Element as existing, complete all as specified and directed.
(a) Water heater 25 litres capacity.
(b)Water heater 50 litres capacity.
Outer body assembly complete with top and bottom for water heater of following capacity, complete all as specified and directed.
(a)Water heater 25 litres capacity.
(b)Water heater 50 litres capacity.
Mounting brackets for Geyser upto 50 litres capacity, complete all as specified and directed
Bib taps cast copper alloy with clutch or butterfly handle screwed for GI pipe 15mm dia chromium plated fency type, fixed as in repairs, complete all as specified and directed.
Stopcock cromium plated screwed down High pressure with crutch or butterfly handle screwed both ends for iron pipe or for union completebib taps cast copper alloy with clutch or butterfly handle screwed for GI pipe 15mm dia, fixed as in repairs, complete all as specified and directed.
Detecting faults at site geysers any type and make in CHAF area under AGE EM CHAF and rectifiying the defects and make it functional including replacing of unserviceable defective electrical/spares accessories, complete all as specified and directed. Note :- (i) Rate for any item shall be measured and paid under respective item of schedule (ii) Essential material like, insulation tape,screws and all tools required for carrying out the works and instruments to the detect fault shall be deemed to be included in the quoted rate (iii) The work is of day to day maintenace, required Electricians and Helper has to be attend daily for carryout the above work.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole 20A MCB ,B curve , 10KA, complete as all as specified and directed.
SB CONSTRUCTIONS
GKR and CO
RRK PROJECTS
Vishwas Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .