Executive Engineer
Executive Engineer (Electrical), Works Organization, Hauz Khas, IIT Delhi, New Delhi - 110016
Supplying and Laying cables and Feeder Pillars at Micro Model in academic area at IIT Delhi.
2020_IIT_570898_1
IITD/WORKS (SP- 3059)/2020
Open Tender
Electrical Works
Works
120 days
IIT Delhi, Hauz Khas, New Delhi
As per tender document
11 documents required · 11 mandatory
₹0
₹46,225
25 Aug 2020
13 Jul 2020
4 Aug 2020
13 Jul 2020
3 Aug 2020
13 Jul 2020
90 days
Amount
Supplying, Installation, Testing & Commissioning of cubical type Feeder Pillar-1 Double Door Outdoor Type suitable for 415V, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with for powder coating for prickling and degreasing in approved shade, having 800 amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears and i/c dismantling of existing panel boards.(Normal Feeder Pillar) Size of Feeder Pillar: 2.52 Sq. Mtr.
INCOMER 1 Nos. 630 Amps. FP MCCB (Type DN3-630D) of 36 KA with inbuilt protection.
MAIN BUS BARS TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec.
1 nos. Digital type Multifunction Meters to show KWH, KVAH, P.F. and Frequency.
3 Nos. phase indication lights LED type with protection MCB.
OUTGOINGS 2 Nos. 400 Amps. FP MCCB of 36 KA with inbuilt protection.
4 Nos. 250 Amps. FP MCCB of 36 KA with inbuilt protection.
Total Panel-I Cubical Type Feeder Pillar AS DESCRIBED ABOVE.
Supplying, Installation, Testing & Commissioning of cubical type Feeder Pillar-2 Double Door Outdoor Type suitable for 415V, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with for powder coating for prickling and degreasing in approved shade, having 800 amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears and i/c dismantling of existing panel boards.(DG Feeder Pillar) Area: 1.8 Sq. Mtr.
INCOMER 1 Nos. 400 Amps. FP MCCB (Type DN3B-400D) of 36 KA with inbuilt protection.
MAIN BUS BARS TPN aluminium bus bars of minimum of 600 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec.
1 nos. Digital type Multifunction Meters to show KWH, KVAH, P.F. and Frequency.
3 Nos. phase indication lights LED type with protection MCB.
OUTGOINGS 4 Nos. 250 Amps. FP MCCB of 25 KA with inbuilt protection.
Total Panel-2 Cubical Type Feeder Pillar AS DESCRIBED ABOVE.
Supplying, Installation, Testing & Commissioning of cubical type Feeder Pillar-3 Double Door Outdoor Type suitable for 415V, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with for powder coating for prickling and degreasing in approved shade, having 800 amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears and i/c dismantling of existing panel boards.(Normal Feeder Pillar) Size: 2.34 Sq. Mtr.
INCOMER 1 Nos. 400 Amps. FP MCCB (Type DN3B-400D) of 36 KA with inbuilt protection.
MAIN BUS BARS TPN aluminium bus bars of minimum of 600 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec.
1 nos. Digital type Multifunction Meters to show KWH, KVAH, P.F. and Frequency.
3 Nos. phase indication lights LED type with protection MCB.
OUTGOINGS 1 Nos. 250 Amps. FP MCCB of 25 KA with inbuilt protection.
2 Nos. 200 Amps. FP MCCB of 25 KA with inbuilt protection.
2 Nos. 160 Amps. FP MCCB of 25 KA with inbuilt protection.
Total Panel-3 Cubical Type Feeder Pillar AS DESCRIBED ABOVE.
Supplying, Installation, Testing & Commissioning of cubical type Feeder Pillar-4 Double Door Outdoor Type suitable for 415V, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with for powder coating for prickling and degreasing in approved shade, having 800 amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears and i/c dismantling of existing panel boards.(Normal Feeder Pillar) Size: 1.6 Sq. Mtr.
INCOMER 1 Nos. 250 Amps. FP MCCB (Type DN1-250C) of 25 KA with inbuilt protection.
MAIN BUS BARS TPN aluminium bus bars of minimum of 300 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec.
1 nos. Digital type Multifunction Meters to show KWH, KVAH, P.F. and Frequency.
3 Nos. phase indication lights LED type with protection MCB.
OUTGOINGS 4 Nos. 160 Amps. FP MCCB of 25 KA with inbuilt protection.
Total Panel-4 Cubical Type Feeder Pillar AS DESCRIBED ABOVE.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 35 sq. mm and upto 95 sq. mm (3.5C x 95 sq.mm)
Above 95 sq. mm and upto 185 sq. mm (3.5C x 120 sq.mm)
Above 95 sq. mm and upto 185 sq. mm (3.5C x 185 sq.mm)
Above 185 sq. mm and upto 400 sq. mm (3.5C x 300 sq.mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Above 35 sq. mm and upto 95 sq. mm (3.5C x 95 sq.mm)
Above 95 sq. mm and upto 185 sq. mm (3.5C x 120 sq.mm)
Above 95 sq. mm and upto 185 sq. mm (3.5C x 185 sq.mm)
Above 185 sq. mm and upto 400 sq. mm (3.5C x 300 sq.mm)
Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium power cable of 1.1 kV grade of following size on cable tray as required.
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) (3.5C x 185 sq.mm)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) (3.5C x 300 sq.mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 95 sq. mm (45mm)
3½ X 120 sq. mm (45mm)
3½ X 185 sq. mm (57mm)
3½ X 300 sq. mm (70mm)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
100 mm dia
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
R. P CONTROLS
Vishram Electrical Works
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .