Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC | ₹44.3 L Quoted ₹45.5 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹46.1 LRejected-Finance | ₹46.1 L | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹47.6 LRejected-Finance CAMP OFFICE RANGE ROAD CHANDIPUR BALASORE ODISHA 756025 | BALASORE | BALASORE | ODISHA | 756025 | ₹47.6 L | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹47.9 LRejected-Finance 1 1 MEREDITH STREET KOLKATA 700072 INDIA | KOLKATA | WEST BENGAL | 700072 | ₹47.9 L | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹47.9 LRejected-Finance 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹47.9 L | L5 | Rejected-Finance Not Being Lowest |
| Sl No | Description | Qty | Unit | ALLIANCE L1 | M/S T.N.CONSTRUCTION L7 | Rekha Enterprises L2 | ELECTRO COMMERCIAL CO L5 | PODDAR SALES CORPORATION L4 | KRISHNA ENTERPRISES L6 | M/S RAJENDRA PRASAD L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, foundations n. exc 1.5 m wide and n.exc 1.5 m in depth for laying of cables,poles and getting out in soft/ loose soil complete all as specified and as directed by Engr-in-Charge. | 165 | Cum | 140 ₹23,100 | 220 ₹36,300 | 157 ₹25,905 | 210 ₹34,650 | 196 ₹32,340 | 240 ₹39,600 | 260 ₹42,900 |
| 2.00 | Returning, filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed by the Engr-in-Charge. | 98 | Cum | 50 ₹4,900 | 110 ₹10,780 | 80 ₹7,840 | 95 ₹9,310 | 90 ₹8,820 | 130 ₹12,740 | 155 ₹15,190 |
| 3.00 | Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level , not exceeding 1.5 metre above the starting point complete all as specified and as directed by the Engr-in-Charge | 65 | Cum | 20 ₹1,300 | 90 ₹5,850 | 65 ₹4,225 | 75 ₹4,875 | 80 ₹5,200 | 85 ₹5,525 | 130 ₹8,450 |
| 4.00 | Supply and laying of new DWC (double wall corrugated) cable duct pipe, ISI marked, IS 16205 (part 24) : 2017 Part II of outer dia 50 mm and inner dia 39.3 mm with smooth internal and profiled external surface for non pressure underground cables including all connected accessories like coupler, o-ring etc complete all as specified and as directed. | 1,116 | Rm | 100 ₹1.1 L | 175 ₹2.0 L | 120 ₹1.3 L | 110 ₹1.2 L | 175 ₹2.0 L | 135 ₹1.5 L | 125 ₹1.4 L |
| 5.00 | Supply and laying of DWC (double wall corrugated) pipe fittings like coupler, o-ring outer dia 50 mm and inner dia 39.3 mm complete all as specified and as directed. ( Note- Fittings will be executed in existing location & repair portion only) | 210 | Each | 10 ₹2,100 | 15 ₹3,150 | 13 ₹2,730 | 9 ₹1,890 | 9 ₹1,890 | 12 ₹2,520 | 9 ₹1,890 |
| 6.00 | Taking down old unserviceable bricks provided for cable protection of any type and size from the trenches complete all as specified and as directed. | 1,250 | Each | 1 ₹1,250 | 8 ₹10,000 | 3 ₹3,750 | 3 ₹3,750 | 5 ₹6,250 | 4 ₹5,000 | 2 ₹2,500 |
| 7.00 | Cutting chases,pinning in,making good of PCC hard, standing to facing where required , exc.10 cm. but not exc.60 cm girth to ends for laying of cables and making good with old shape and size all as specified and directed. | 50 | Rm | 150 ₹7,500 | 175 ₹8,750 | 165 ₹8,250 | 155 ₹7,750 | 250 ₹12,500 | 165 ₹8,250 | 195 ₹9,750 |
| 8.00 | Cutting Bituminous road in,making good with facing where required and pointing exc.30 cm. but not exc.1.0 mtr. girth to ends laying of cables and making good with old shape and size all as specified and directed. | 40 | Rm | 200 ₹8,000 | 210 ₹8,400 | 217 ₹8,680 | 350 ₹14,000 | 195 ₹7,800 | 219 ₹8,760 | 215 ₹8,600 |
| 9.00 | Supply and laying as in replacement GI tubing light grade 80 mm with all fittings laid in trenches/road crossing/hard standing/drain/along the pole/wall for protection of cable including taking out old GI tubing and making surface in good codition all as specified and directed . | 18 | Rm | 750 ₹13,500 | 760 ₹13,680 | 764 ₹13,752 | 775 ₹13,950 | 780 ₹14,040 | 777 ₹13,986 | 768 ₹13,824 |
| 10.00 | All as per serial item 9 here-in-before but of dia 50 mm complete all as specified and directed by Engr-In-Charge. | 18 | Rm | 500 ₹9,000 | 555 ₹9,990 | 512 ₹9,216 | 510 ₹9,180 | 555 ₹9,990 | 521 ₹9,378 | 524 ₹9,432 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
29 Sept 2025, 6:00 pmClosed
Garrison Engineer
GE (I) R and D Chandipur, Post-Chandipur, PIN-756025
REPAIR REPLACEMENT OF EXTERNAL ELECTRIFICATION DEHYDRATION OF TRANSFORMERS AND REPAIR TO DG SETS WITH CONNECTED WORKS AT BALASORE AND SITE N NILGIRI UNDER AGE BR BALASORE
2025_MES_729824_1
8224/A/E8
Open Tender
Civil Works
180 days
GE (I) R AND D CHANDIPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (I) R AND D CHANDIPUR
₹90,000
Yes
16 Jan 2026
8 Sept 2025
30 Sept 2025
8 Sept 2025
29 Sept 2025
22 Sept 2025
Amount
Excavation in trenches, foundations n. exc 1.5 m wide and n.exc 1.5 m in depth for laying of cables,poles and getting out in soft/ loose soil complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed by the Engr-in-Charge.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level , not exceeding 1.5 metre above the starting point complete all as specified and as directed by the Engr-in-Charge
Supply and laying of new DWC (double wall corrugated) cable duct pipe, ISI marked, IS 16205 (part 24) : 2017 Part II of outer dia 50 mm and inner dia 39.3 mm with smooth internal and profiled external surface for non pressure underground cables including all connected accessories like coupler, o-ring etc complete all as specified and as directed.
Supply and laying of DWC (double wall corrugated) pipe fittings like coupler, o-ring outer dia 50 mm and inner dia 39.3 mm complete all as specified and as directed. ( Note- Fittings will be executed in existing location & repair portion only)
Taking down old unserviceable bricks provided for cable protection of any type and size from the trenches complete all as specified and as directed.
Cutting chases,pinning in,making good of PCC hard, standing to facing where required , exc.10 cm. but not exc.60 cm girth to ends for laying of cables and making good with old shape and size all as specified and directed.
Cutting Bituminous road in,making good with facing where required and pointing exc.30 cm. but not exc.1.0 mtr. girth to ends laying of cables and making good with old shape and size all as specified and directed.
Supply and laying as in replacement GI tubing light grade 80 mm with all fittings laid in trenches/road crossing/hard standing/drain/along the pole/wall for protection of cable including taking out old GI tubing and making surface in good codition all as specified and directed .
All as per serial item 9 here-in-before but of dia 50 mm complete all as specified and directed by Engr-In-Charge.
Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 150 Sqmm 3.5 core as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc including taking down/up existing unserviceable cable complete all as specified and as directed by the Engr-in-Charge.
All as per serial item No 11 as above but of size 120 Sqmm 3.5 core
All as per serial item No 11 as above but of size 70 Sqmm 3.5 core
All as per serial item No 11 as above but of size 50 Sqmm 3.5 core
All as per serial item No 11 as above but of size 35 Sqmm 3.5 core
All as per serial item No 11 as above but of size 25 Sqmm 3.5 core
M&L Cable jointing kit for HT 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185- 240 sqmm including taking down old one complete all as specified and as directed
M&L for heat shrikable type LT Jointing kit for 1.1 KV XLPE cables of size 70-150 sqmm 3.5/4 core straight through joint complete including taking down old one complete all as specified and as directed
M&L for heat shrikable type LT Jointing kit for 1.1 KV XLPE cables of size 25-50 sqmm 3.5/4 core straight through joint complete including taking down old one complete all as specified and as directed
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I (2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
Material and labour in replacement for Galvanised iron strip 32 x 6 mm burried in ground complete all as specified and directed by the Engineer-in-Charge.
M&L for Dyhydration/fltration of Transformer oil including testing of dielectric strength of transformer oil of indoor type transformer, 11KV/433 volt, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete as specified. (Note: i)Transformer oil will be measured & paid seperately.ii) Note : Test certificate shall be submitted before and after filteration for dielectric strength.)
M&L for Removing old burnt Transformer oil and Supply and toping of transformer oil with 50KV di-electric strength complete all as specified.
Supply and fixing of hydrogenated nitrile transformer oil seal, with maximum di electric strength duely tightened with bushings complete to avoid leakage from transformer bushings of various transformer installed at variuos locations under Colaba area all as specified and directed .
M & L for spray painting to indoor/outdoor type, step up/step down transformer installed at different location of Balasore and Nilgiri area after scraping throughly the existing corroded paint/rust, filing of cavaties and applying two coats of heat resistant paint of approved quality of required colour and writing the details such as SM/MES No. etc.of capacity 150 KVA/250 KVA/315 KVA/400 KVA all as per specified and directed by Engr - in - Charge .
Dismantling of Damaged Breather and Supply and fixing in repair of breather with 500 Grams celica gel of indoor type transformer 150 KVA/250 KVA/315 KVA/400 KVA, all as specified and directed by Engineer-in-Charge.
Dismantling of Damaged thermometer and Supply and fixing in repair of thermometer(oil temperature gauge) for indoor type transformer, all as specified and directed by Engineer -in -Charge.
Material and labour for Servicing/Repairing of Transformer by disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4Nos LT bushing and 3Nos of HT bushing including necessary tools and plant for removal of sediments,carbon deposits at bottom of transformer tank, on core,on winding etc cleaning with new transformer oil including cleaning of oil tank and attending leakage problem with oil seal and all gaskets and re assembling complete of capacity Transformer 150 KVA/250 KVA/315/400 KVA ,11KV/433Volt all as specified and directed. (Note : New Transformer oil and spare parts will be measured and paid separatley excluding oil seal)
Material and labour for replacing Burnt out Studs and bushing with nuts (set of three) of any material by providing new copper alloy stud with nut,washers and bushing on HV Side for transformer of capacity 150 to 300 KVA complete all as specified and directed.
Material and labour for replacing Burnt out Studs and Bushing with nuts (set of four) of any material by providing new copper alloy stud with nut,washers and bushing on LV Side for transformer of capacity 150 to 300 KVA complete all as specified and directed.
Dismantlin of old damaged Cooling Fins and Supply and fix in repair cooling fins of transformer of capacity 150 KVA to 400 KVA as per manufacturer's specifications and standard practice complete all as specified and directed.
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolly of rupturing capacity 250/350 MVA, 400/630/800 Amps from location and repair /overhauling and carrying out with the following activities as mentioned below and replacement of unservicable following itmes as and where required complete all as specified and directed by Engineer-in-Charge. (Note: spare parts will be measured & paid seperately.) (i) Inspecting / overhauling of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw,motor cut -off limit switch, butter fly swich assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of tripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Assembling all items/components parts to the respective postion & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete.
Dismantling of Old Damaged/burnt spare parts from VCB and Supply and fixing in repair of following Spare parts suitable for - VCB 11 KV, indoor type of all as specified and directed by Engineer-in-Charge.
Isolating Contacts flat type
Vaccum InterupterVG2
Insulating Rod
Closing coil 110V /24V DC
Tripping Coil 110V /24V DC
Spring Charging Motor 110V-230V AC/DC
Breaker Auxiliary Switch 6NO +6NC
Motor Cut-off switch
Main Drive Shaft assembly
Trip Fork Linkage Assembly
Rachet Wheel
Pin for Rachet
Closing coil assembly without coil
Trip coil assembly without coil
Motor cutt off Lever assembly
Auxiary switch drive Assembly
Buffer for Spring
Over Rid Stop
Over Rid Stop Pin
24 Pin Plu and Socket Assembly
Bus Bar Spout Insulator with CC parts for R Phase
Bus Bar Spout Insulator with CCparts for Y Phase
Bus Bar Spout Insulator with CC parts for B Phase
Circuit Spout Insulator with CC Parts
3 Phase Spout Insulator assembly Bus bar /Circuit side.
Raising and lowering Handle
TNC Switch,16Amps Recom
Ammeter, digital type, DM3110 Schneider
Voltmeter,digital type DM3210 Schneider
Multifunction meter digital typeEM6400NG Schneider
Indicating Lamps24/110V DC LED type
Test and service limit switch
Capacitor type power back up unit with input 119 volt AC, output 110 volt DC, 100 watt continuous with impulse 400 watt
PT fuse, 3.15A.
Fuse link-2A.
S& F battery (12V/180AH) complete all as specified and as directed
T&P for fault finding on HT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including Dismantling of cross arms of MS channel or angle sections etc complete all as directed
M&L for Servicing the existing Gang operated Air Break switch, operated from ground, of capacity 200 / 400 Amps, 11 KV, 3 Pole, including greaasing, replacing worn out/ rusted nuts, bolts, washers, etc. and providing coloured sleaves for jumper connections complete all as specified and as directed.
Taking down unserviceable GOD from existing two/four pole structure and Supply , fix Air Break, Gang operated Triple pole switches/device , mechanically operated, mounted on insulator and steel frame,with operating mechanism of GI tubing 25 mm switable length worked from ground level including locking accessories complete for current rating up to 400 Amps complete with 12 insulators complete all as specified and directed.
Taking down unserviceable lightning arresters from two/four pole structure and supply ,fix lightning arresters expulsion type complete with all fittings, transmission station class,of dischrge capacity 65 Kilo amps complete suitable for 11000 volts complete all as specified and directed.
M&L in repair for expulsion fuse (DO Fuse) single pole 11000 Volts 100 Amps complete all as specified and directed.
M&L for stay assembly complete with accessories as shown in electrical plate No 1 with stay rod 16 mm dia including dismantling the old unsv stay complete all as specified and directed by Engr-in-Charge. Note : Excavation and concreate shall be measured and paid separetly
Supply and install steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410SP-55 (11.0 meter long) and including painting with two coats of aluminium paint over one coat of red oxide and black bituminous paint on the hidden surface in foundation including drilling of holes for fixing of D Iron clamp and holes for continous GI earth wire as required complete including dismantling of old unsv steel poles/ struts any size all as specified and directed
Supply and fixing for Pin type , porcelain, vitreous, white , brown or green insulator including one galvanised mild steel spindle , two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 150 mm height,150 mm dia for 11000 volts grade complete all as specified and as directed.
M&L for disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type , white, brown or green with tension clamps for conductors, working pressure 11000 volts complete as specified and as directed.
M&L for anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete as specified and as directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size
M&L for graded coarse aggregate of nominal size 40 mm well spreading at substations including cleaning of surfaces of sustation complete all as specified and as directed.
M&L for cleaning and painting of substation with two coat of white wash complete as as directed and specified.
Supply and fill Electrolite water for battery use all as specified and directed.
Supply and fill distilled water for Battery use all as specified and directed
S&F in repair of self starter 12 volts duly rewinding & replament all required accessories etc of DG sets capacity from 10 KVA to 63 KVA DG set complete and testing all as specified and directed by Engr in Charge.
Servicing / repairs to DG Set 15 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smoth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Primary & Secondary Fuel Filter Element - 2 Nos (b) Spin on filter Element for lubricating oil - 1 No (c) Kirloskar Oil Premium (Engine oil 15W 40) - 5 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 7.1 Ltr.
Servicing / repairs to DG Set 25 KVA capacity (Make : Kirloskar) by checking all running parameters and adjusting / caliberating for smoth functioning including cleaning of diesel tank and supply and replacing the following items complete (a) Primary & Secondary Fuel Filter Element - 2 Nos (b) Spin on filter Element for lubricating oil - 1 No (c) Kirloskar Oil Premium (Engine oil 15W 40) - 6.5 Ltrs (d) Coolant Make : Valvoline or eqiuvalent - 14.5 Ltr.
Supply and replace 12 Amps charge control unit 12 Volts complete all as specified and directed.
S&F in repair of alternator (battery charger) 14 volts 35 Amps duly rewinding & replament all required accessories etc of DG sets capacity from 10 KVA to 200 KVA DG set complete and testing all as specified and directed by Engr in Charge.
S&F battery lead copper of 50 sqmm as per sample ( Red and Black colour ) and taking down old U/S battery lead all as specified and directed by Engr in Charge.
S&F battery terminal positive marking /negetaive marking of brass of existing size and taking down old U/S battery terminal all as specified and directed by Engr In Charge.
Taking down old unsv street light at any height Supply and fixing LED street light fitting 45 Watt230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Taking down old unsv street light at any height Supply and fixing LED street light fitting 60 Watt230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Taking down old unsv street light at any height Supply and fixing LED street light fitting 70 Watt230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Taking down old unsv street light at any height Supply and fixing LED street light fitting 100 Watt230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Taking down old unsv flood light at any height Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Taking down old unsv flood light at any height Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Taking down old unsv flood light at any height Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Taking down old unsv flood light at any height Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Taking down old unsv post top lantern light at any height Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Taking down old unsv garden light and supply and fix LED garden light of capacity 11W or next higher rating, protection rating IP-65, made of extruded almunium housing, architectural design, with integrated LED drivers, internal pre wired, including fixing up with existing cable complete all as specified and as directed.
Supply and fix in repair triranga LED strip lights of capacity 8W/m, 18 meter length for each strip comprising of tricolour (Amber, white and green colour), IP 65 rating, PVC material, 96 or more LED per meter , with uniform light distribution, including integrated electronic driver outdoor type, to be fixed in street light poles complete all as specified and as directed.
Supply & Fixing MCCB 4 pole,415 V,with thermal-magnetic release adjustable type,400 amps with breaking capcity 36 KA including taking down old unserviceable one complete all as specified and as directed.
Supply & Fixing MCCB 4 pole,415 V,with thermal-magnetic release adjustable type,250 amps with breaking capcity 36 KA including taking down old unserviceable one complete all as specified and as directed.
Supply & Fixing MCCB 4 pole,415 V,with thermal-magnetic release adjustable type,160 amps with breaking capcity 36 KA including taking down old unserviceable one complete all as specified and as directed.
Supply & Fixing MCCB 4 pole,415 V,with thermal-magnetic release adjustable type,125 amps with breaking capcity 36 KA including taking down old unserviceable one complete all as specified and as directed.
Supply & Fixing MCCB 4 pole,415 V,with thermal-magnetic release adjustable type,63 amps with breaking capcity 36 KA including taking down old unserviceable one complete all as specified and as directed.
M&L for cleaning of LT panels and bus bar chamber and replacement of burnt/damaged busbar of aluminium of existing size including disconnecting and taking down LT cable of any size, re-fixing of same after carrying out the repair and replacement of cable lugs/ thimble and replacement of locking arrangement /sliding bolts, knobs and rubber beading capacity including two coat of synthetic enamel paint and writing the location(Incoming/outgoing) using synthetic enamel paint as directed by Engr-In- Charge complete all as specified. NOTE- The minor Spares like nuts, bolts,screws,washers,Insulation Tapes,lugs/thimble, Busbar Sleeves used in repair works are included in the scheduled item rates. The spare parts like MCBs, MCCBs etc. will be paid separately )
Demolition of cement concreate(unreinforced) of description and in any position complete all as specified and as directed.
M&L for cement concrete PCC(1:2:4) type B1 using 20mm graded aggregate for in surface channels, duct,filling or mass concrete complete all as specified and directed by Engr-In-Charge.
M&L Rendering 15mm thick in Cement Mortar 1:6 on Fair Faces of Brick Work or Concrete Surfaces, Plastered Surfaces finishing Fair and Even complete all as specified and as directed.
Supply & Replace lead acid type wet cell battries of Capacity 100 Amp/hr 12V for DG sets including taking down the old one and deposit to department store complete all as specified and as directed.
Rekha Enterprises (BID ID -3438244)
M/S RAJENDRA PRASAD (BID ID -3437521)
PODDAR SALES CORPORATION (BID ID -3438316)
ELECTRO COMMERCIAL CO (BID ID -3438295)
KRISHNA ENTERPRISES (BID ID -3438787)
M/S T.N.CONSTRUCTION (BID ID -3437841)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid