Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹31.7 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹36.3 L+₹4.6 L (14.5%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L-2 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹99,800
Closing Date
1 Feb 2023, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
AUGMENTATION AND IMPROVEMENT OF LT PANEL, LT CABLE, EARTHING AND IMPROVEMENT / REPAIR OF SUMMER APPLIANCES, GEYSERS INCLUDING CONNECTED WORKS AT DAMANA UNDER GE JAMMU
2023_MES_573372_1
GEJC-67/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹99,800
Yes
24 Feb 2023
6 Jan 2023
3 Feb 2023
6 Jan 2023
1 Feb 2023
20 Jan 2023
Amount
Labour for repair / servicing of ceiling fan of any capacity complete with strip opening the ceiling fan for repair / washing / varnishing and removing of old lubricating substatances from bearing / bush by using Kerosene oil, carrying out fresh lubrication, greasing and to make the ceiling fan noise free and smooth functioning, including replacement of worn out / unserviceable minor spare parts split pin, fan body bolts, spring washer, fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm upto 1.0 m long, assembling the repaired ceiling fan and testing to the entire satisfication of Engineer-in-Charge and depositing in MES store yard complete all as specified and as directed. Note: - Replacement of spares flexible wire etc / rewinding of ceiling fan shall be measured and paid separately under respective item for material and labour cost.
Labour for repair / servicing of exhaust fan of any type and sweep complete with strip opening the exhaust fan for repair / washing / varnishing and removing of old lubricating substatances from bearing / bush by using Kerosene oil, carrying out fresh lubrication, greasing and to make the exhaust fan noise free and smooth functioning, including replacement of worn out / unserviceable minor spare parts split pin, fan body bolts, spring washer, fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm upto 1.0 m long, assembling the repaired exhaust fan and testing to the entire satisfication of Engineer-in-Charge and depositing in MES store yard complete all as specified and as directed. Note: - Replacement of spares flexible wire etc / rewinding of exhaust fan shall be measured and paid separately under respective item for material and labour cost.
Rewinding of ceiling fan of any make / type and size (1200 sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer's specification including replacement of all insulation materials, varnishing, heating, drying, assembling of stator / rotor, connection and testing complete all as specified and as directed.
Rewinding of exhaust fan of any make / type and sweep with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer's specification including replacement of all insulation materials, varnishing, heating, drying, assembling of stator / rotor, connection and testing complete all as specified and as directed.
Labour for remetalling of worn out shaft of fan, cutting, bracing, machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the entire satisfaction of Engineer-in-Charge to ensure smooth and noise free operation complete all as specified and as directed. Note: - Bearing shall be measured and paid separately.
Supply and fixing ball bearing of any size and type, suitable for any type / make / size of ceiling fan complete all as specified and as directed.
Supply and fixing ball bearing of any size and type, suitable for any type / make / size of exhaust fan complete all as specified and as directed.
Supply and fixing in replacement of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and rated capacity 2.5 MFD for ceiling fan complete all as specified and as directed.
Supply and fixing in replacement of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and rated capacity 4.0 MFD for exhaust fan complete all as specified and as directed.
Supply and connection of PVC insulated, unsheathed multi stranded, three core twisted copper flexible cable of size 1.5 Sqmm as required complete all as specified and as directed.
Supply and fixing only bush of suitable size for exhaust fan of any type / size as per existing type complete all as specified and as directed.
Supply and fixing of PVC connector 4 way 6 Amps with connection screws, nuts complete all as specified and as directed.
Supply and fixing of galvanised iron / mild steel anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole complete all as specified and as directed.
Supply and fixing in replacement of mild steel clamp for down rod of suitable size including gromet / reel type rubber pad with bolts, nuts, split pin and washers suitable for housing ceiling fan complete all as specified and as directed.
Supply and fixing in replacement of ceiling fan down rod 12 mm dia and 30 / 45 cm long complete with mild steel clamp, rubber reel, split pin, nut, bolts etc. complete all as specified and as directed.
Cleaning of ceiling fan assembly of any type / size and carrying out two coats of spray painting with first quality synthetic enamelled paint of approved colour including writing of MES number in black paint complete all as specified and as directed.
Cleaning of exhaust fan assembly upto 450mm and carrying out two coats of spray painting with first quality synthetic enamelled paint of approved colour including writing of MES number in black paint complete all as specified and as directed.
Taking down and strip opening to geyser of any make and capacity 25 litres including disconnection of all water pipe connection and taking out water inlet / outlet assembly, removing glass wool, the inner tank, descaling the assembly and tank, detecting the leakage, welding / brazing the defective parts, repacking the glass wool and refixing the same after making it functional including replacement of worn out nuts, bolts, washers etc complete all as specified and as directed. Note: - Cost of material and labour for providing new items shall be measured under relevant items of Schedule 'A'.
Material and labour for replacement of water inlet and outlet geyser assembly of existing make as required at site with rubber gasket suitable for geyser of 25 litres capacity electric driven water storage heater with provision of housing for thermostat assembly, heating element fixing arrangement nuts, bolts and washers etc complete all as specified and as directed.
Material and labour for replacement thermostat, switch for electric water heater storage type of capacity 25 litre, 230 Volts of existing make of geyser complete all as specified and as directed.
Material and labour for replacement heating element with triangular base / round base, single phase, 230 Volt, capacity 2 KW of existing make complete all as specified and as directed.
Material and labour for replacement heating element with triangular / round base, single phase, 230 Volt, capacity 1.5 KW of existing make complete all as specified and as directed.
Material and labour for replacement pressure release valve conforming to relevant IS 15mm bore suitable for fixing with galvanised iron pipe / tubing 15mm bore complete all as specified and as directed.
Material and labour for replacement of heavy duty PVC connection (For Hot water) nylon threaded 450mm large (18") 15mm bore including brass nuts, rubber washers complete on both ends complete all as specified and as directed.
Material and labour for replacement of heavy duty PVC connection (For Cold water) nylon threaded 450mm large (18") 15mm bore including brass nuts, rubber washers complete on both ends complete all as specified and as directed.
Material and labour for replacement of indicator lamps round / rectangular type 230 Volt AC suitable for geyser of any capacity including providing electric connections complete all as specified and as directed.
Material and labour for replacement water storage inner tank of stainless steel heavy duty confirming to ISI 25 litres capacity geyser, with provision for fixing 15mm dia galvanized air release valve complete all as specified and as directed.
Supply and fixing in replacement MCB SPN 32 Amps, 240 Volts, rupturing capacity 10 KA, 'C' series complete all as specified and as directed.
Supply and fixing in replacement plug top 15 Amps, 3 pins complete all as specified and as directed.
Material and labour for replacement non return valve 15mm dia complete all as specified and as directed.
Material and labour for repair / maint to desert coolers complete with and including cleaning, scrapping / rubbing old rusted surface, filling cavities and painting with two coats of high quality aluminium paint over a coat of red oxide primer externally and black paint internally with synthetic enamelled paints complete with replacement of necessary nut, bolts, rubber pads for fan motors and writing MES No / unit name all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of desert cooler fan motor 90 watt,1400 RPM, 230 volt 50 Hz, single phase conforming to ISI complete with fan blade and capacitor of suitable size complete all as specified and as directed.
Supply and fixing in replacement of desert cooler submersible pumping set single phase 230 volt, 50 Hz of 0.25 to 1.0 HP conforming to ISI complete with lead all as specified and as directed.
Supply and fixing in replacement of desert cooler fan motor blade of existing size made out from mild steel having duty complete with key bolt all as specified and as directed.
Supply and fixing in replacement of desert cooler side opening cover made out from heavy duty mild steel sheet and matching with the existing desert cooler body size complete with Khas Khas pads set of three pieces complete all as specified and directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 1.5 Sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI all as specified and directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 2.5 Sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI all as specified and directed.
Supply and fixing in replacement of plug top 3 pin, 5 Amp, 230 Volt, 50 Hz complete all as specified and directed.
Supply and fixing in replacement of capacitor 4.0 MFD including PVC accessories for desert cooler fan motor, 230 volt, 50 Hz complete all as specified and as directed.
Supply and fixing in replacement of unserviceable Khas Khas / Glass wool for desert cooler set of three pieces complete all as specified and as directed.
Repair / Maint / Servicing to refrigerator / deep freezer / water coolers / AC's of any capacity and model by replacing capillary tubing, gas chargings, rectification of leakage in capillary tubing / Chiller plant / water tanks, condensing coils, repair to wiring, flushing / cleaning condensing / cooling coils / internal / external unit of split AC, greasing to blower motors, replacement of spare parts, fan belts and make refrigerator / deep freezer / water coolers / AC's in serviceable condition complete all as specified and directed by Engineer-in-Charge. Note: - Spare / Gas charging shall be paid separately.
Charges for fixing in replacement of unserviceable sealed seamless welding compressor unit company manufacturer of any capacity for AC's complete with initial filling / charging of refrigerant gas to meet the requirement complete with vibration rubber pads four numbers each nut, bolts etc and testing on full load all as specified and directed by Engineer-in-Charge. Notes: - (i) Spare parts shall be measured and paid separately under respective items. (ii) Contractor shall be responsible for all replacement of failed compressor and shall be accompanied by certificate from the original compressor to the effect that said compressor has been repaired at their authorised service center. Further, a warrenty of 12 month shall be provided on such replacement in writing.
Supply only sealed compressor unit seamless welding company manufacturer with filling of refrigerant gas conforming to ISI as under: -
For refrigerator 165 / 286 litre capacity
For refrigerator 290 / 320 litre capacity
For Deep freezer 100 / 200 litre capacity
For Deep freezer 300 / 400 litre capacity
For Water cooler 40 / 80 litre capacity
For Water cooler 60 / 120 litre capacity
Split / Window AC 1.5 Ton capacity
Split / Window AC 2.0 Ton capacity
Supply and fixing in replacement of unserviceable / burnt condensing fan motor 1 / 35 HP single phase 230 volt 50 Hz complete with blade, fan belts for water cooler of capacity 40 / 80 litre and 60 / 120 litre complete all as specified and as directed.
Supply only condensing fan motor 1 / 5 HP 1440 RPM single phase 230 Volt 50 Hz with double blade and shaft end with fan belts for windows AC / Split AC conforming to ISI of capacity 1.5 / 2.0 ton complete with vibration parts etc. complete all as specified and as directed.
Supply and charging refrigerant 134a / R-22 / 412 A in sealed compressor unit of refrigerator / deep freezer / water coolers / AC's of any type and capacity after flushing the complete system with carbon tetrachloride (CTC) and vacuumise the complete system with vacuum pump and testing on full load including replacement of filter, strainer complete all as specified and directed.
Supply and fixing in replacement of following spare parts for refrigerator / deep freezer / water coolers / AC's of any capacity: -
Starting relay
Overload protector
Thermostat switch
Defroz switch
Supply and fixing in replacement of following unserviceable spare parts of water cooler of any capacity: -
Starting capacitor 45 mfd
Running capacitor 60 / 120 mfd
Float valve PVC 15 mm dia with ball
Push cock chromium plated 15 mm with nipple 6'' long
Drain / Wash out flexible down pipe 40 mm dia
Water tank door gasket
Water drain tray of suitable size
Supply and fixing in replacement of unserviceable following spare parts of window / Split AC unit of capacity 1.5 to 2.0 ton: -
Starting capacitor 36 / 40 mfd
Running capacitor 100 / 120 mfd
PCB of Split AC
Front grill cover for window AC 1.5 Ton
Condensing fan motor double shaft
Supply and fixing in replacement of PVC flexible braided pipe of 20 mm dia for split AC water drain out all as specified and directed.
Supply and fixing in replacement of MCCB TPN 400 Amps, 415 Volts, 36 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit adjustable type including complete connection all as per directions of Engineer-in-Charge.
Supply and fixing in replacement of MCCB TPN 250 Amps, 415 Volts, 25 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit adjustable type including complete connection all as per directions of Engineer-in-Charge.
Supply and fixing in replacement of MCCB TPN 200 Amps, 415 Volts, 25 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit adjustable type including complete connection all as per directions of Engineer-in-Charge.
Supply and fixing in replacement of MCCB TPN 160 Amps, 415 Volts, 25 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection all as per directions of Engineer-in-Charge.
Supply and fixing in replacement of MCCB TPN 100 Amps, 415 Volts, 16 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection all as per directions of Engineer-in-Charge.
Supply and fixing in replacement of MCCB TPN 63 Amps, 415 Volts, 10 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection all as per directions of Engineer-in-Charge.
Supply and fixing in replacement of on load open execution change over switch 4 pole, 415 volts, 200 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fixing on wall and angle iron bracket of size 40 x 40 x 6mm thick as per size requirement or all as specified and as directed.
Supply and fixing in replacement of on load open execution change over switch 4 pole, 415 volts, 100 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fixing on wall and angle iron bracket of size 40 x 40 x 6mm thick as per size requirement or all as specified and as directed.
Supply and install connecting, testing and commissioning of high pressure single head adjustable aqua fit dosing system of following specifications inject pressure up to 25 LPH working pressure 10 Kg / cm square, power input 230 Volts, 50 Hz, 40 Spm, 1/30 fractional horse power maximum output 10 litres per hour with mandatory accessories like lead tubing, connecting ferrules, check valve etc. including taking down old unserviceable chlorination plants. (i) Preparation of tank of net capacity 150 litres, FRP dosing tank dia 650 x net height 375 + conical 300 gross height with stand 1000 mm consisting of: - (a) Water inlet line (b) Outlet with strainer (c) Drain (d) Over flow (e) Conical bottom for sludge disposition (f) Pot hole with cover (g) Level gauge (h) Agitator 120 Watt 900 RPM single phase flange mounted motor with plastic shaft and impeller. (ii) Service tank dia 480 x height 575 net capacity 10 Litre consisting of: - (a) Water inlet line (b) Dosing pump inlet arrangement (c) Provision of mounting pump on lid / wall (d) Over flow (e) Level gauge (f) Inspection port (g) Agitator 120 Watt 900 RPM single phase flange mounted motor with plastic shaft and impeller. (h) Provision of mounting pump on lid / wall
Dismantling all incoming / outgoing electric connections carefully of voltage stabilizer, LT panel, change over switch etc and repair the cable, fixed properly with proper aluminium thimble / lugs including preparation of cable end for jointing (incoming / outgoing cable connection for each cable will be measured as one job each). Thimble shall be measured separately under respective items complete all as specified and as directed.
Labour for disconnecting all incoming / outgoing electric connction carefully of fully automatic servo voltage stabilizer having capacity 20 to 100 KVA and transport to workshop for repair / servicing and including dismantling top cover of stabilizer and taking out the coil, drain out the transformer oil and refilling after dehydration of transformer oil, cleaning internally, including replacement of unserviceable body nut, bolts, washers, top gasket of cork sheet 6mm thick, replacement of internal circuit wiring if any suitable size of copper wire and painting with heat resistant smoke grey synthetic enamelled paint including preparation of old rusted surfaces and writing MES NO, SM MES No, capacity, Ser No, Location etc and reinstallation / connecting electric connection with replacement of proper size aluminium lugs and testing on full load at site complete all as specified and as directed. (a) Spare parts shall be measured and paid separately. (b) Rotor for replacement of spare parts are deemed to be included in above jobs.
Supply and fixing in replacement of synchronous motor single phase 230 Volt suitable for servo voltage stabilizer having capacity 20 to 100 KVA complete all as specified and as directed.
Supply and fixing in replacement of PCB suitable for servo voltage stabilizer having capacity 20 to 100 KVA complete all as specified and as directed.
Supply and fixing in replacement of dimmer motor suitable for servo voltage stabilizer capacity 20 to 100 KVA complete all as specified and as directed.
Supply and fixing in replacement of toggle On / Off switches for stabilizer capacity 20 to 100 KVA complete all as specified and as directed.
Supply and fixing in replacement of Volt meter 0-500 Amp 96 Sqmm type, 3 phase, 230 volt, 50 Hz complete all as specified and as directed.
Supply and fixing in replacement of Ampere meter 0-400 Amp, 96 Sqmm type, 3 phase, 230 volt, 50 Hz with CT of suitable ratio complete all as specified and as directed.
Supply and fixing in replacemenet of gun metal, gate valve, 20 mm for drain out of oil complete all as specified and as directed.
Supply and fixing in replacement of unserviceable brass / gun metal stud bush suitable for 20 to 100 KVA complete with connecting rod of suitable length and dia with necessary nut, bolt, washer, bushing, packing to prevent the leakage from bushes and necessary connection complete all as specified and as directed.
Dehydration of transformer oil and dielectric strength of oil achieved not to be less than 42 KV at 2.5 mm gap complete all as specified and as directed.
Supply and filling of new transformer oil for top up upto automatic servo voltage stabilizer including heating and dielectric strength not to be less than 60 KV complete all as specified and as directed.
Taking out main coil of voltage stabilizer 20 to 100 KVA for repair / rewinding with super enamelled copper winding wire of existing gauge including PVC insulated sheet sleeve, varnishing etc all as required and refixing to the stabilizer after testing all as required at site or as specified and as directed by Engineer-in-Charge.
Supply, installation and commissioning and testing of LT panel cubical type suitable size for 415 volts 3 phase 4 wire, 50 Hz AC supply system, floor mounted, outdoor type factory fabricated duly powder coated inside and outside, outer shell made out of 3 mm thick CRCA sheet, internal shell and partition made out of 2mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable, weather proof including 400 Amp rating of copper bus bar for 3 phase 4 wire system with IP 54 as per IS : 13947 protection, fault rating 50 KA / Sec, wiring with suitable size copper cable and embedded in brick work in cement mortar (1:4) not less than 60 cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. complete comprising of following complete all as specified and directed by Engineer-in-Charge, including taking down of old unserviceable panels from site. Incoming: - (a) MCCB 4 pole adjustable thermal and fixed magnetic type, 250 Amp, 36 KA, 415 volts AC - 01 No. (b) Copper bus bar 400 Amp - 04 No's (TPN). (c) Multifunctional Digital meter (VAF, W/VA/VAR/PF) - 01 No. (d) CT 500/5A, Set of Three. (e) Indicator lamp LED type (R, Y, B) complete with bakellite fuse fitting - 01 Set. Outgoing: - (a) MCCB 4 pole adjustable, 200 Amp, 36 KA, 415 volts AC - 01 No. (b) MCCB 4 pole adjustable, 100 Amp, 25 KA, 415 volts AC - 02 No's. (c) MCCB 4 pole adjustable, 63 Amp, 16 KA, 415 volts AC - 01 No's. (d) On load 250 Amp, 415 Volts panel mounted change over switch - 01 No. (e) MCB TPN 40 Amps - 02 No's.
Supply, installation and commissioning and testing of LT panel cubical type suitable size for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system, floor mounted, outdoor type factory fabricated duly powder coated inside and outside, outer shell made out of 3 mm thick CRCA sheet, internal shell and partition made out of 2mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6mm covered from all side with front and back openable, weather proof including 300 Amp rating of copper bus bar for 3 phase 4 wire system with IP-54 as per IS : 13947 protection, fault rating 50 KA / Sec, wiring with suitable size copper cable and embedded in brick work in cement mortar (1:4) not less than 60 cm above ground level with suitable foundation for fixing panel of required size in ground with nuts, bolts and washer etc. complete comprising of following complete all as specified and directed by Engineer-in-Charge, including taking down of old unserviceable panels from site complete all as specified and as directed. Incoming: - (a) MCCB 4 pole adjustable and fixed magnetic type, 200 Amp, 36 KA, 415 volts AC - 01 No's. (b) Copper bus bar 315 Amp - 04 No's (TPN). (c) Multifunctional Digital meter (VAF, W/VA/VAR/PF) - 01 No. (d) CT 200/5A, Set of Three. (e) Indicator lamp LED type (R, Y, B) complete with bakellite fuse fitting - 01 Set. Outgoing: - (a) MCCB 4 pole adjustable, 160 Amp, 25 KA, 415 volts AC - 01 No. (b) MCCB 4 pole adjustable, 63 Amp, 16 KA, 415 volts AC - 02 No's. (c) On load 200 Amp, 415 Volts panel mounted change over switch - 01 No. (d) MCB TPN 40 Amps - 02 No's.
Supply and fixing in replacement of submersible cable 25 Sqmm 3 core flat copper conductor heavy duty 1100 volts grade confirming to ISI complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of submersible cable 16 Sqmm 3 core flat copper conductor heavy duty 1100 volts grade confirming to ISI complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of submersible cable 10 Sqmm 3 core flat copper conductor heavy duty 1100 volts grade confirming to ISI complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of submersible motor rotor for 10 to 25 HP motor complete, suction head 70 RM, discharge 12000 GPH complete with bearing upper / lower bearing housing, sleeves, tee bolts and bush complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of submersible motor stator / pump for capacity 10 to 25 HP motor, suction head 70 RM, discharge 12000 GPH complete with thrust plate, thrust bearing with housing, studs, water seal, sand guard, rubber diaphragm with plate, sealing bush complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of submersible motor rotor for 35 to 50 HP motor complete, suction head 70 RM, discharge 12000 GPH complete with bearing upper / lower bearing housing, sleeves, tee bolts and bush complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of submersible motor stator / pump for capacity 35 to 50 HP motor, suction head 70 RM, discharge 12000 GPH complete with thrust plate, thrust bearing with housing, studs, water seal, sand guard, rubber diaphragm with plate, sealing bush complete all as specified and directed by Engineer-in-Charge.
Material and labour for replacement of CI sluice valve PN 1.6 with iron wheel head of size 100 mm bore with stainless steel spindle both end flanged complete with nut, bolts, washer and rubber gasket 3 mm thick conforming to ISI : 14846/2000 complete all as specified and directed.
Material and labour for replacement of tubing GI "medium grade" with flange ends all fittings laid in borewells including taking out old unserviceable pipe of size 100 mm dia complete all as specified and directed.
Material and labour for replacement of tubing GI "medium grade" with flange ends all fittings laid in borewells including taking out old unserviceable pipe of size 80 mm dia complete all as specified and directed.
Material and labour in replacement for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI strip 32 x 6 mm (upto 7.5 m in length from earth plate) by means of bolts and nuts, checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate No. 3 of SSR part - I including necessary excavation and earth work in any type of soil PCC (1:3:6) type C-1 chamber with RCC (1:2:4) type B-1 40 mm thick cover with mild steel rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering and pouring extra clay soil of quantity not less than one cubic meter into the earth pit and also removal of excavated soil not less than 50 metre from the earthing place complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanized steel plate earth electrode 60cm x 60cm x 6mm thick buried in ground vertically to a depth not less than 1.5 metre below normal ground level connected to galvanized iron wire of 4 mm dia earth lead by means of bolts, nuts and washers made of galvanized iron protected by 40mm bore light grade GI pipe up 7.5 RM with 4mm earth lead and connected for body earthing of feeder pillar box all as specified and including PCC (1:3:6) type C-2 pit and precast RCC (1 : 1 ½ : 3) type A-1 pit cover slab of size 300 x 300 x 50mm with handle as shown in drawing funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work and excavation in hard / dense soil and removal etc complete all as specified in electrical plate No. 3 of SSR Part - I 2020.
Disconnecting and taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3½ core complete all as specified and as directed.
M/s Sahib Construction and engineers
Bidder Name
Sarbat Construction Co
M/s Sahib Construction and engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .