| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.2 LAccepted-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹15.0 L+₹2.1 L (16.6%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹19.4 L+₹6.6 L (51.2%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹23.0 L+₹10.1 L (79.0%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹23.5 L+₹10.7 L (83.0%)Rejected-Finance | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹25.0 L
EMD Value
₹50,000
Closing Date
9 May 2024, 6:00 pmClosed
GE (AF) PALAM
GE (AF) PALAM DELHI CANTT-10
REPAIR / MAINTENANCE OF FIRE FIGHTING, FIRE DETECTION SYSTEM AND OTHER CONNECTED ITEMS AT AF STN PALAM UNDER GE AF PALAM, DELHI CANTT-10
2024_MES_650354_1
8024/A/T-01/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) PALAM
₹50,000
Yes
4 Jul 2024
18 Apr 2024
16 May 2024
18 Apr 2024
9 May 2024
2 May 2024
Amount
Supply and fixing fire hydrant landing valve type 'A' (single head outlet) gun metal of 80mm dia landing valve with 63mm dia female outlet complete and 80mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63mm with coupling conforming to IS 903 including taking down the existing one complete all as specified and as directed by Engr-in-charge.
Supply and fixing of weather proof standard fire hose box made of 18SWG MS sheet 800mmX600mmX250mm with double door with 4mm thick glass and door frame made of 16 gauge including locking arrangement by allen key stove enamelled fire red finish with "fire hose" marked on front and brilliant white inside yard, suitable for housing of and consisting of 2 length RRL, hose pipe conforming to IS 6361979 (type-II) of 63mm dia GM instantaneous male and female (IS:903) and branch pipe (nozzle) 12.5mm dia (for external hydrant) including taking down the existing one complete all as specified and directed by Engr-in-charge.
Supply, fixing, testing and commissioning of wall mounting swinging type first aid fire hose reel with drum, hanging bracket 30mtr long and 20mm dia high pressure hosereel as per IS 444 with gun metal shutt off nozzle. The hose reel shall be conforming to IS 884-1985. Rate shall including for 25mm dia MS pipe connection from riser to hose reel sockets, nipples, elbows and ball valve (25mm dia), Drum shall be fixed on adjoining wall through anchor fastener/cement concrete hook or MS stand as per site requirement and the rate for fixing/hanging items inthe rate quoted( for internal hydrant and one each an either side of stage) including taking down the existing one complete all as specified and directed by Engr -in-charge.
Supply and fixing in replacement of fire hydrant MS stand post 1.5mtr height single head outlet gunmetal of 80/150mm dia including all necessary surface finish with existing type complete all as specified and directed by Engr-in-charge.
Supply, fixing , testing and commissioning of GM four way, fire brigade inlet to hydrant ring with 63mm dia instantaneous type inlet and 150mm dia flanged outlet conforming to IS 904 with blank cap and chain including taking down the existing one complete all as specified and directed by Engr-in-charge.
Supply, fixing , testing and commissioning of GM two way, fire brigade inlet to hydrant ring with 63mm dia instantaneous type inlet and 150mm dia flanged outlet conforming to IS 904 with blank cap and chain including taking down the existing one complete all as specified and directed by Engr-in-charge.
M & L for Pressure switch in replacement universal type for maintaing pressure in fire fighting line complete all as specified and directed by engineer in charge.
M & L for pressure gauge in replacement 4 " dial 0-21 KG rating for monitoring pressure in fire fighting line complete all as specified and directed by engineer in charge.
Supply, fixing, testing and commissioning in replacement of 150mm pipe heavy duty class 'C' MS pipe ISI marked as per IS:1239 with all necessary fittings & fabrication like tees, elbow, flanges, reducer, gaskets, nut and bolts etc welding or screwed joint as required including fixing of pipe with necessary standard clamps, structural steel support (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red color over two coats of red oxide primer including taking down the existing one complete all as specified and directed by Engr-in-charge.
Description all as per ser item no. 9.00 above but dia of pipe 80mm complete all as specified and as directed by Engr- in -Charge.
Supply & fixing in replacement of butterfly valve of size 150 mm dia conforming to IS 13095, flanged ends drilled type with steel spindle including nuts, bolts, washers and jointing material complete all as specified and as directed by Engr-in-charge.
Supply & fixing in replacement of butterfly valve of size 100 mm dia conforming to IS 13095, flanged ends drilled type with steel spindle including nuts bolts washers and jointing material complete all as specified and directed by Engr-in-charge.
Construction of brick masonary valve chamber of size (900x900x900)mm (internal dimensions) with PCC (1:4:8) foundation 150mm thick, brick masonary built in CM (1:6), PCC (1:3:6) Type C1 (using 20mm graded stone aggregate) coping 50mm thick, plastering 15mm thick in CM (1:6) to all internal including provision of MS cover with locking arrangement embedded with angle iron of size (40x40x6)mm and painted with two coats of synthetic enamal paint over the red primer complete all as specified and as directed.
M & L for boring holes under road pavement hard standing by trenchless technology using ultra sound technique and necessary machine for accomodating pipe of size 150/80 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
M&L for cutting of hard standing/road upto 0.6 meter depth and thickness of size up to 180 mm suitable for fixing of 150/80mm bore MS pipe and filling with ready mix cement concrete and making good disturbed surface complete all as specified and as directed.
S&F fire foam concentrator drum of 200 ltr capacity for producing mechanical foam for fire fighting in and including replacement of existing plastic/PVC pipe, nozzle/fixing mechanism complete all as specified and as directed by Engineer -in -Charge.
S&F in replacement of 63mm dia15mtr long controlled perclating rubberised fabric hose conforming to IS: 8423 (type A) including gun metal male and female instantaneous coupling bound and rivetted to hose pipe with 1.5mm dia copper wire complete in all respect, hose BSI marked, conforming to IS : 636 type II and complete male female coupling conforming to IS:903 complete all as specified and as directed by Engr-in-charge.
M&L for Servicing of induction motor 75 HP coupled with fire pump complete including oiling, burnt winding replacement, greasing, replacement of wornout rubber packing, wornout nuts and washers etc including testing to the entire satisfaction of Engineer- in- charge complete all as specified and as directed.
M&L for Servicing of induction motor 15 HP coupled with fire pump complete including oiling, burnt winding replacement, greasing, replacement of wornout rubber packing, wornout nuts and washers etc including testing to the entire satisfaction of Engineer in charge complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr depth and n.exc 1.5 mtr wide for laying of pipes/cables etc and getting out complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed.
Supply and fixing branch pipe nozzle 63mm dia inlet with 20mm dia complete all as specfied and as directed.
Comprehensive monthly maintenance of fire fighting system installed in BBJ Hanger in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning, inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire hydrant system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out skilled and qualified authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement shall be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) Fire hydrant (b) Hose reel drum (c) Hose pipe. (d) Branch pipe (e) Three way/Four way Fire valve (f) Pressure testing in pipe (g) 200ltr Fire foam with drum. (h) And other connected items in the bldgs completed
Comprehensive monthly maintenance of fire fighting system installed in RSS Hangar and ISH in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning, inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire hydrant system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out skilled and qualified authorised Rep. (v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement shall be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) Fire hydrant (b) Hose reel drum (c) Hose pipe. (d) Branch pipe (e) Three way/Four way Fire valve (f) Pressure testing in pipe (g) 200ltr Fire foam with drum. (h) And other connected items in the bldgs completed
Comprehensive monthly maintenance of fire fighting system installed in ISH Bldg in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning, inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire hydrant system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out skilled and qualified authorised Rep. (v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) Fire hydrant (b) Hose reel drum (c) Hose pipe. (d) Branch pipe (e) Three way/Four way Fire valve (f) Pressure testing in pipe (g) 200ltr Fire foam with drum. (h) And other connected items in the bldgs completed
Comprehensive monthly maintenance of fire fighting system installed in CPRU in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning, inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire hydrant system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out skilled and qualified authorised Rep. (v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement shall be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) Fire hydrant (b) Hose reel drum (c) Hose pipe. (d) Branch pipe (e) Three way/Four way Fire valve (f) Pressure testing in pipe (g) 200ltr Fire foam with drum. (h) And other connected items in the bldgs completed
Comprehensive monthly maintenance of fire fighting system installed in C Flight Hanger No-1 in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning, inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire hydrant system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out skilled and qualified authorised Rep. (v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement shall be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) Fire hydrant (b) Hose reel drum (c) Hose pipe. (d) Branch pipe (e) Three way/Four way Fire valve (f) Pressure testing in pipe (g) 200ltr Fire foam with drum. (h) And other connected items in the bldgs completed
Comprehensive monthly maintenance of fire fighting system installed in C Flight Hanger No-2 in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning, inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire hydrant system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out skilled and qualified authorised Rep. (v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement shall be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) Fire hydrant (b) Hose reel drum (c) Hose pipe. (d) Branch pipe (e) Three way/Four way Fire valve (f) Pressure testing in pipe (g) 200ltr Fire foam with drum. (h) And other connected items in the bldgs completed
Comprehensive monthly maintenance of fire fighting system installed in C Flight Hanger No-3 in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning, inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire hydrant system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out skilled and qualified authorised Rep. (v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement shall be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) Fire hydrant (b) Hose reel drum (c) Hose pipe. (d) Branch pipe (e) Three way/Four way Fire valve (f) Pressure testing in pipe (g) 200ltr Fire foam with drum. (h) And other connected items in the bldgs completed
Comprehensive monthly maintenance of fire fighting system installed in Fire section (NXC BLDG) in Tech Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire hydrant system in presence of rep of users and Engr-in-charge. (iii) The contractor will submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out skilled and qualified authorised Rep. (v) Emergency visit will be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement will be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) Fire hydrant (b) Hose reel drum (c) Hose pipe. (d) Branch pipe (e) Three way/Four way Fire valve (f) Pressure testing in pipe (g) 200ltr Fire foam with drum. (h) And other connected items in the bldgs completed
Comprehensive monthly maintenance of fire fighting system installed in NCDSC Bldg in Camp area Area at AF Stn Palam. The detail scope of work consists of the following:- (i) Cleaning, inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire hydrant system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge. (iv) The maintenance shall be carried out skilled and qualified authorised Rep. (v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Materials required for replacement shall be measured and paid separately under respective items of this schedule. Note:- The detail of fire equipments required repairs/maintenance are as under:- (a) Fire hydrant (b) Hose reel drum (c) Hose pipe. (d) Branch pipe (e) Three way/Four way Fire valve (f) Pressure testing in pipe (g) 200ltr Fire foam with drum. (h) And other connected items in the bldgs completed
M&L for painting of MS pipes of different sizes as per existing colour with synthetic enamel paint complete all as specified and as diected.
S&F in repair cast iron sluice valve with cast iron wheel stainless steel spindle water quality conforming IS - 14846 class PN - 1.6 short bodies ISI marked as and when required of the following size including taking out unserviceable sluice valves complete all as specified and as directed by Engg-in-Charge:-- (a) 150 mm dia
(b) 80 mm dia
(c) 200 mm dia
M&L for painting of equipments installed at fire fighting pump house like electic motor with pump with base frame, connected pipelines, sluice valve, Non return valve and all other items with synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
S&F cast iron non return valve of size 50mm as per IS:5312, Part-I with by pass arrangement both end flanged and drilled holes with suitable 3mm thick rubber insertion, bolt and nuts including taking out the unserviceable valve complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of coupling for connecting of MS pipes including replacement of nuts and bolts for proper connection as per existing size of pipes and making good for proper functioning complete all specified and as directed by Engineer-in -Charge.
S&F in replacement of butterfly valve of size 80 mm dia conforming to IS 13095 , flanged ends drilled type with steel spindle including nuts, bolts, washers and jointing material complete all as specified and directed by Engr-in-Charge.
Satish Kumar Gupta
GARG TRADERS
Flint India
Precision Safety Equipment Limited
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .