Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹33.7 LAccepted-AOC | ₹33.7 L | L-1 | Accepted-AOC lowest bidder |
| 2 | L-2₹36.2 L+₹2.5 L (7.37%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹36.2 L+₹2.5 L (7.37%) | L-2 | Rejected-Finance Being not lowest tenderer |
| 3 | L-3₹41.3 L+₹7.5 L (22.3%)Rejected-Finance | ₹41.3 L+₹7.5 L (22.3%) | L-3 | Rejected-Finance Being not lowest tenderer |
| 4 | L-4₹43.1 L+₹9.3 L (27.6%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | ₹43.1 L+₹9.3 L (27.6%) | L-4 | Rejected-Finance Being not lowest tenderer |
| 5 | L-5₹43.8 L+₹10.0 L (29.7%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹43.8 L+₹10.0 L (29.7%) | L-5 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹39.4 L
EMD Value
₹78,720
Closing Date
6 Oct 2023, 6:00 pmClosed
HQ CWE (U) DELHI CANTT-10
HQ CWE (U) DELHI CANTT-10
REPAIR REPLACEMENT OF WORN OUT 33KV SWITCHGEAR PADS AND REPLACEMENT OF 110 V 52V 24V BATTERY BANKS MAINTANENCE OF POWER OUTDOOR INDOOR DISTRIBUTION TRANSFORMER CT PT LA LINE DIFFERENTIAL RELAYS PROTECTIVE RELAYS WITH ACCESSORIES CALIBRATION OF RELAYS
2023_MES_615863_2
CWE(U)/D-20/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DELHI CANTT
As per NIT
8 documents required · 8 mandatory
₹500
GE(U) ELECTRIC SUPPLY, DELHI CANTT -110010
₹78,720
Yes
6 Dec 2023
22 Sept 2023
13 Oct 2023
22 Sept 2023
6 Oct 2023
30 Sept 2023
Amount
M&L for replacement earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip of size 32x6mm upto 7.5 Mtr length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion with frame funnel and GI watering pipe of 20 mm dia medium grade, wire mesh, copper lugs and 40 mm bore light grade protection pipe to test point including testing etc all complete as specified and directed by Engr-in-Charge.
M & L for cutting and removing grass, vegetation bushes etc from surrounding of 4 pole/6 pole HT structure/ 33 KV yard and outside area of HT installation and removing all rubbish to a distance not exceeding 50 m as directed at site by Engr-in-Charge.
Material and labour for spreading & leveling of stone aggregate of nominal size not more than 63 mm under 4/6 pole HT structure/surrounding area of outdoor RMU manually without damaging any equipments, cable or parts in layers n. exc. 15 cm thick watered and rammed to true surface complete all as specified and directed
Supplying & laying in replacement synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006 (superseding IS 5424) of size 2m x 1m complete all as specified and directed.
All as per srl item no 4.00 here-in-before but 3 mm thick suitable for 33 KV size 2 m x 1 m.
M&L for painting with two coats of superior aluminium paint including necessary preparation of old existing surfaces of wire mesh / matte steel fencing by brushing/cleaning complete steel structure/frame/ gate for 11 KV / 0.433 KV TFR up to 30 Sqmm area complete all as specified and directed.
Supply in replacement of rubber hand gloves ISI Marked suitable for working on HT 33/11 KV.
Supply and fix in replacement of cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all a specified.
Material and labour for servicing of HT control panel including outdoor CT, PT and relays in control panel of outdoor breaker of capacity 1250 Amps and rating 36 KV complete as per the under mentioned details:- Details of servicing of HT Panel (breaker) :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iv) Checking the contact for wear. Replace if the contact piece has worn out. (v) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (vi) Checking/replacement of rust and wear. (vii) Checking of spring charge mechanism (viii) Checking/replacement of loosened bolts and nuts, broken spring washers and snap pins etc. (ix) Checking/replacement of loosened connections, rust, damaged lead wires. (x) Checking of control circuit & tighten the connections if any.
M&L for Servicing & Repairs to air-break switch (isolator) off load, rotating type, 33 KV, 800 Amps to 1250 Amps capacity, with proper alignment of isolator rotating blades, with fixed contact jaws, arcing horns, applying petroleum jelly to moving mechanism, cleaning and lubricating to isolator gear box assembly, tightening all nuts, bolts and clamps of jumpers etc, repairing to isolator gear box assembly and making in proper serviceable condition for smooth functioning, testing and commissioning on load complete all as specified and directed. (Note:Spare parts will be paid under respective items of supply only)
Supplying only in replacement male/moving contact/ rotating blade made up of HDE copper silver plated of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc complete all as specified and directed.
Supplying only in replacement Fixed Contacts, made of HDE copper, silver plated, of Air Brake, off load isolator switch, rotating type, 33 KV, 1250/800 Amps capacity with all fixing nuts, bolts etc. complete all as specified and directed.
Supply, installation, testing and commissioning in replacement (in set of 3) of lightening arrestor SMX type outdoor complete with all fittings transmission class 36 KV 10 KA 50 Hz suitable for system voltage 33/36 KV complete all as specified and directed.
Supplying ,fixing and testing in replacement of master trip relay, 24 Volt DC in control panel including wiring complete all as specified and directed at site by Engr-in-Charge.
Supplying ,fixing and testing in replacement of master trip relay, 110V Volt DC in control panel including wiring complete as directed at site by Engr-in-Charge.
Supplying ,fixing and testing in replacement of master trip relay, 50 Volt DC in control panel including wiring complete as directed at site by Engr-in-Charge.
Supplying ,fixing and testing in replacement of Trip circuit supervision relay, 50/24 Volt DC in control panel including wiring complete as directed at site by Engr-in-Charge.
Supplying ,fixing and testing in replacement of DC supervision relay, 50/24 Volt DC in control panel including wiring complete as directed at site by Engr-in-Charge.
Supplying and fixing in replacement PT fuse for 11 KV/110 V PT complete as directed at site by Engr-in-Charge.
Supply, installation and testing in replacement of over current & earth fault feeder protection relays comprising of the following protection auxiliary working voltage at 110 V to 24 V DC supply, with 4 count inputs CT / 15 / 1 A, 5 discrete & 9 discrete outputs DNP3, modbus RTC, IEC 60870-5-103 communication flush mounted (a) over current ANSI code 50/51 (b) Re-closer ANSI code: 79 (c) cold pickup (d) Earth fault code 50G/51G (e) Phase under current ANSI code: 37 (f) Restricted earth fault ANSI code : 64 REF (g) Negative sequence overcurrents ANSI code : 46 (h) Fault recording (i) Event recording (j) Disturbance Recording (k) Trip circuit supervision ANSI code : TCS
Supply and fix in replacement Digital volt meter 0-15 KV in HT 11 KV VCB panel working on auxiliary supply of 110V including associated wiring, if reqd, complete all as specified and directed.
S&F in replacement of PG clamps aluminium cast alloy suitable for ACSR conductor (dog / panther ) for straight connections/ cross / T connections of type( as per conductor) 33 KV yard with GI nuts, bolts etc complete all as specified and directed.
Material and labour for preparation of old painted surfaces of 33 KV yard including all steel structures/ frame/gate of bus bay at Grid at a height of 10 mtrs to 15 mtr from GL consisting of 5 nos isolator per bay CT and PT and VCB supporting structure by brushing/cleaning stains, greasy spots with thinner, applying two coats of spray painting of existing colour using synthetic enamel paint with spraying machine in the yard complete all as specified and directed. Note:- Rate quoted are deemed to be inclusive of all safety measures.
M&L for replacement of aluminium jumper made of ACSR conductor of type Dog / Panther of size not less than 1 mtr of length conductor of 33 KV yard. (1x 06 nos jumper ) complete al as directed.
Material and labour for Preparation of old painted surfaces of fencing of 33 KV yard Shankar Vihar grid by brushing/cleaning stains, greasy spots with thinner, applying two coats of synthetic enamel paint of existing colour complete all as specified and directed.
M&L for Laminated paper sticker of letter size 250 mm x 8 mm in Red/Black/ White colour and printing of SM/MES No/feeder name/CT ratio etc as provided by Engr-in-Charge in black colour and pasting the same on HT/LT panels complete all as specified and directed. Note:- Each sticker shall have different printing matter.
Material and labour for replacement of Retro Reflective installation sign boards of size 5 feet x 4 feet fabricated out of 16 gauge MS sheet frame duly welded/riveted with MS square pipe of size 25mm x25mm at height 2.00 meter above ground level on stainless steel heavy duty pipe of size 50mm bore embedded 60 CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx60cm including necessary excavation and earth work .The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The written matter will be in English language on both sides with reflective adhesive painter tapes as directed by Engineer -in-charge.
Supply and fix in replacement of silica gel breather assembly complete with breather unit and silica gel including connecting with proper rubberised gasket and necessary fittings GI fittings for fixing/assembling upto 1000KVA transformer complete by removing the unserviceable silica gel breather assembly all as specified and directed.
Supply and installation in replacement Anti-condensation space-heater with Thermostatic control in cable and circuit breaker compartments of HT switchgears complete all as specified and directed.
Taking out of heavy duty colling fan ,3 phase, 50 Hz of size 18" to 24" from power transformer 33/11 KV of capacity 8/10 MVA ,servicing of the fan by opening including cleaning, greasing , replacement of defective spares parts such as bearing/ bushing, capacitor, canopy, clamp, blade, etc with new spare parts and painting of fan body with synthetic enamel paint and re-assembling in existing position after repairs and testing complete all as directed by Engr-in-Charge. Note :- (a) The cost of spare parts is deemed to be included in quoted rates . (b) Rewinding of the fan will be measured and paid separately under respective item of schedule here-in-after.
M&L in replacement for rewinding of heavy duty cooling fan, 3 phase, 50 Hz of size 18" to 24" of power transformer 33/11 KV capacity with super enamelled copper wire as per existing gauge including heating, varnishing, etc complete as required and directed by Engr-in-Charge.
S & F in replacement of hooter complete with switch etc suitable for warming HT 11 KV VCBs internal chambers all as directed
S & F in replacement battery 12V, DC, 100 AH maintenance free dry battery complete all as specified and as directed.
S & F in replacement battery 2V, DC, 7 AH maintenance free dry battery complete all as specified and as directed.
S & F in replacement of exhaust fan 450 mm sweep heavy duty with heavy duty bearings, balanced blades louvers single phase supply complete with accessories all as specified and as directed.
M&L for painting of HT 11 KV VCB panel with two coats of super enamel paint over a coat of red-oxide with spray gun including preparation of surfaces writing of incoming/outgoing/Bus coupler name/numbers in appropriate size of letters as directed and as specified.
M&L for opening of the VCB , 11 KV 400 to 2000 Amps of any make by removing of the breaker from the existing position after disconnecting all the connections from the system, servicing, overhauling of the same, checking of the same for proper operation, spring charge, charged control cables are fastened tightly to the terminals, any abnormality, VCB, cleaning the surface of the insulators, fasten the bolts, checking and correcting interrupting units, mechanism, linkages etc, fasten the hardware of control wiring, check that the split pins, Circlips, dowel pins etc. have not come out and are intact, lubricate the mechanism, moving parts by castrol, all purpose grease or equivalent, check that the vacuum pots/chambers is within limit including opening of the shutters properly, replacing of the trip catch, roller, holding catch, stopper, close push button, closing cum reassembling, control limit switches reconnecting of the breaker for smooth functioning all as directed.
M&L for decarbonizing/cleaning complete HT cable outgoing/Incoming circuit of CTs & PTs, 3 phase, cleaning with CTC and ensure proper decarbonizing, re-fixing the same after applying becktol (Red) solution to the spout, checking all the connections, tightening the nuts, bolts thimbles for incoming and outgoing system complete, as specified and directed. Rate quoted is deemed to be inclusive of supply of becktol Red, CTC & cotton waste.
Material and labour for testing and calibration of HT Panel Complete as mentioned under - (i) Primary Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance. (vii) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (a) Over current and earth fault relay (b) DC Supply supervision relay. (c) Master trip relay Note:- (i) DC Supply for relay testing shall be arranged by the contractor. Nothing extra shall be paid on this account.
M&L for ON load / ON line centrifuging and dehydration including filtration and cleaning of transformer oil by dehydration machine of 33 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filtration complete all as specified and directed. Note :- Transformer oil required for top up shall be measured and paid separately under item No 41 here-in -after as supply only.
Supply of transformer oil of approved quality as per IS :335(2018) having dielectric strength of 45-60 KV in 2.5mm gap for filling in OLTC & for topping up in transformer as required and directed.
Material & labour for repair /overhauling of OLTC ( On load tap changer ) of 33KV/11KV Power transformer of capacities 8/10 MVA at site by carried out following work of existing make :- (a) Opening of top plate of OLTC. (b) Draining out of transformers oil from the OLTC. (c) Stopping of leakage of oil from main shaft of OLTC including replacement of oil seal and all gasket of OLTC. (d) Checking /servicing of moving and fixed contact of OLTC and resistance test of contact. (e) Flushing of OLTC assembly with hot new oil and removing of sludge. (f) Filling of new transformer oil in OLTC . (g) Tightening of all tapping leads and connections. (h) Refixing of top plate of OLTC in original position after overhauling. (i) Electrical testing of manual/auto operation of OLTC. Note :- Transformer oil as required shall be measured and paid separately under srl item No. 41 here-in -before as supply only.
Supply, fixing and testing in replacement (in set of 3) of the 33 KV current Transformer paper impregnate oil immersed type,single phase 50 HZ conforming to IS:2705/1992 ( Part I,II,III & IV) with latest amendment in all respect except where ever modified in this specification:- (a) Normal system voltage (KV rms) 33 KV (b) Highest system voltage (KV rms) 36 KV (c) Frequency 50 Hz (d) Transformation ratio (CT Ratio) 400-200/1-1-1-1A (e) Rated output (VA burden) core 1-15 VA, Core 2-30 VA (f) Accuracy class -core1-1.0, core2-5P10 (g) Short time current 31.5KA RMS for 3 sec (h) Rated continuous thermal current 120% of rated current (j) Insulation Level- 36/70 KV.170 KVP (k) Max. temp. rise over max. ambient temp. of 50 deg. C at rated continuous thermal current at rated frequency and with rated burden.
Supply and fix in replacement Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm complete all as specified and directed.
Supply and fix in replacement Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 Sqmm to 185 sqmm complete all as specified and directed
Supply and fix in replacement Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 Sqmm to 300 sqmm complete all as specified and directed.
Supply, jointing and testing of end termination joint in replacement of outdoor type heat shrinkable type complete with jointing material and accessories suitable for 33 KV(E) XLPE armoured aluminium conductor cable of size 300 to 400 sqmm 3 core complete all as specified and directed.
Supply, jointing and testing of end termination joint in replacement of indoor type heat shrinkable type complete with jointing material and accessories suitable for 33 KV(E) XLPE armoured aluminium conductor cable of size 300 to 400 sqmm 3 core complete all as specified and directed.
Supplying, laying, testing and connecting 185 sqmm 3 core cable in replacement / rerouting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminium conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed of size.
Supplying, laying, testing and connecting 300 sqmm 3 core in replacement / rerouting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminium conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed. ( Loc :- Near Vikram Vihar Drain)
Supplying, laying, testing and connecting 120 sqmm 3 core in replacement / rerouting XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminium conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed. ( Shankar Vihar )
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil) for laying of cables or GI pipe and getting out including levelling of bottom suface to required level complete all as specified and directed.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
Supplying and laying in replacement un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm all as directed.
Returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including laying of HDPE pipe of 160 mm dia suitable for 0.6 mpa working pressure complete all as specified and directed by Engr-in-Charge.
Material and labour for route tracing the 11 KV HT cable all as specified by Engr-in-Charge.
Supply, installation, testing and commissioning in replacement (in set of 3) Potential Transformer (PT) oil cooled out door single phase ( Earthed type) (IS 2705-1992)of voltage ratio 33 KV/110 V class 3P - 0.5-3, burden 100 VA -100VA insulation level of 70/170 KV (a) Normal system voltage 33 KV (b) Highest system voltage 36 KV (c ) Sectional length - 525 +/- 15 mm (d) Minimum creep distance - 942 mm (Approx). (e) Minimum Dry arcing distance - 397 mm (Approx). (f) Number of shed No - 8 (g) Shed distance - 100 mm. (h) Specified mechanical load (KN) - 70. (i) P F visible discharge voltage 27 KV rms (j) P F minimum flash over voltage (Dry) 106 KV rms (k) P F Minimum flash over voltage (wet) 87 KV rms (l) Impulse flashover voltage 1.2/50micro second wave (negative) 241 KVp (m) Impulse flashover voltage 1.2/50 micro second wave(Positive) 230 KVp (n) Power frequency puncture withstand voltage on single unit 150 KV rms
Supply, installation and testing in replacement of Microprocessor Based, transformer differential Relay draw out type suitable for HT Panel comprising of new and modern numerical scheme for detecting, indicating and tripping the breaker on faults of differential current, over-current and earth-fault in any of the three phases of transformer, Trip circuit supervision relay. The relay shall also have SCADA communication flush mounted on the RTCC 33 KV control the following features as minimum; (i) Programmable rated current 1A, 5A & DC 48 Volt (ii) Last 8 fault record & 200 event record with time stamping, (iii) 4 analog input, 8 DI & 8 DO, (iv) Communicable on IEC61850 protocol, (v) Disturbance recording upto 300 cycles, (vi) Self supervision function. (vii) Phase current differential protection (viii) Three phase Non directional/Directional overcurrent protection (ix) Earth fault protection (x) Undercurrent (xi) Transient Overreach and overshoot (xii) Thermal overload (xiii) Direct transfer trip and inter relay command transfer (xiv) Permissive intertrip (xv) Protection signalling channel, Dual redundancy, channel failure, propagation time check and error statistics (xvi)Comatibility with external interfaces
Laying only old un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm all as specified and directed.
M&L for sticking of ready made sticker with letters,figures clearly mention, Name , SM No, in red colour of size for HT VCB , RMU, Step down transformer 0.6M x 0.2 M size complete as specified and directed.
M & L in replacement of control cable wiring and junction box of CT , PT ,junction box, & CR Panel for the existing 33/11 KV power transformer at Shankar Vihar along with following connected items (a) 10 core 2.5 Sqmm FRLS copper control cable (Each 03 CT to junction Box- 80 RM) (b) 4 core 2.5 Sqmm FRLS copper control cable ( Each 03 PT to junction Box-80 RM) (c) 20 core 2.5 Sqmm FRLS copper control cable (Junction box to CR Panel for 03 CT-70 RM) (d) 6 core 2.5 Sqmm FRLS copper control cable (Junction box to CR Panel for 03 PT-80 RM) (e) 16 core 2.5 Sqmm FRLS copper control cable (VCB to CR Panel-115 RM) (f) 16 core 2.5 Sqmm FRLS copper control cable (Transformer Marshalling box to CR Panel-110RM)
M P TYAGI ENGINEERS AND CONTRACTORS
M/s JAIMAA ASSOCIATES
Vijay Electricals
mayur enterprises
MV Engineers And Contractors
Rajindera Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .