Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L1 | Accepted-AOC Being_L1 | |
| 2 | L2₹6.5 L+₹27,063 (4.34%)Rejected-Finance 17 A SUBASH CHANDRA BOSE STREET MELAKARUNKULAM POST PALAYAMKOTTAI TALUK TIRUNELVELI 627 356 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627356 | L2 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 3 | L3₹7.2 L+₹93,698 (15.0%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L3 | Rejected-Finance quoted amount is higher than 1st lowest | |
| 4 | L4₹7.6 L+₹1.4 L (22.1%)Rejected-Finance E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L4 | Rejected-Finance quoted amount is higher than 1st lowest |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
16 Sept 2023, 6:00 pmClosed
AGE I AF Coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
MAINT REP AND REPLACEMENT TO INTERNAL ELECTRIFICATION FOR ZONE A AND ZONE B AT AFAC UNDER AGE (I) (AF) COIMBATORE
2023_MES_613823_1
8820_E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AFAC
Class-E category-b(i) (see NIT for detail)
7 documents required · 7 mandatory
₹500
AGE I AF COIMBATORE
₹16,000
Yes
30 Sept 2023
15 Aug 2023
23 Sept 2023
15 Aug 2023
16 Sept 2023
29 Aug 2023
15 Aug 2023 - 28 Aug 2023
Amount
Receiving/recording complaints lodged by the occupants of all Md/OTM Accn of AFAC, Coimbatore area under AGE (I) (AF) Coimbatore of internal electrification nature, rectification of the fault / complaints as per the complaint lodged by the user or as given by MES from DB's box / Electric Meter having switch, fuses, MCB distribution board in sheet metal enclosure, point wiring, fixture for light/ Fan/bell/light or power sockets complete repairs to the extent by removing connections from the system, removing faults in wires, batten, conduit, sunk boxes, junction boxes, main switches, MCBs/DBs utility light fittings, FTL light fitting any wattage lamp, holders, ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty stores such as insulation wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws, nuts as required to rectify the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engineer-in-Charge/users. Note: Note : (i) All the complaint(s) received will be lodged & rectified by the contractor rep and will have to maintain a proper record as directed in complain register and in complai slip (ii) Complain slip and complain register will be provided by the contractor without any extra charge. (iii) Complain regiter will be produced on daily basis to JE and Engr-in-charge (iv) If contractor fails to attend the complaints within 24 Hrs of time a recovery of Rs 100 shall recovered per complaint. (v) Contractor shall employee having ITI or equivalent certificate from Govt. institution with 4 year experience in the said field. (vi) The new items provided shall be measured and paid for separately under relevant items of Sch ‘A’.
Taking down old unserviceable point wiring (light, fan socket or power) complete, including fixture and fittings such as switches,ceiling rose, pendents, regulators,sockets, light fittings etc.removing materials for keeping for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. complete all as specified and directed.
Taking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed surfaces all as directed.
Disconnecting electric connection and taking down main switch/DB of any size and keep in safe custody for taking credit complete and good/levelling the disturbed surfaces of wall to match with existing surface complete all as specified and directed.
Sub main wiring complete with 2 runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with one run of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories in concealed conduit all as specified and as directed. Note :- 2 runs of 4 sqmm, 1 run of 4 sqmm earth wire and 1 run of PVC conduit shall be measured as one unit length
All as per item No 05 herein before but but 2 runs of 6 sqmm and one run of 6 sqmm as earth wire complete all as specified and directed. Note :- 2 runs of 6 sqmm, 1 run of 6 sqmm and 1 run of PVC conduit shall be measured as one unit length
M&L for concealed Point wiring one light point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : Cutting chases and making good in wall / floor will be Measured and paid seperately.
All as per item No 07 herein before but one ceiling/exhaust fan point controlled by one, one way switch complete all as specified and directed.
All as per item No 07 herein before but one light point controlled by two 2 way swithch complete all as specified and directed.
All as per item No 07 herein before but one 05 Amps socket outlet point on same board complete all as specified and directed.
All as per item No 07 herein before but one switch socket outlet point 5 Amps on independent board complete all as specified and directed.
All as per item No. 07 described here-in-before but with copper conductor cable FRLS 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent boardcomplete all as specified and directed.
Supply LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make-Havells/Bajaj/Crompton
Supply and fixing LED lights fitting (T-8) 1x 22W, 220V, regal batten type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.. Make-Havells cat Part No REGA:BATTEN8UPTO1X22WSSBSWH and equivalent Make Philips/Bajaj/Wipro
Supply and fixing LED light fitting mirror type withhigh out put diffuser 2 feet, 10 watt 220 V ACdecorative type with driver holder and LED lampincluding connecting up with three core flexiblecopper conductor cable of suitable size complete all as specified and directed. Make-Havells/Bajaj/Crompton
Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 3-in-1 colour changes (warm/day cool/milky white etc), 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Material only in repair for unserviceable post top lantern LED type of any watt and size 230 watt volts AC outdoor type with decorative post top by replacing wornout driver, LED lamp, flexible cable and make the light in operational condition complete all as specified and directed.
Supply only in repair LED light fitting 1X10W Bulk head luminaires including LED light driver holder connecting up with three core flexible copperconductor cable of suitable size. Make-Havells/Bajaj/Crompton
Supply only in repair 25 mm rigid non metallic PVC conduit excusive of boxes (junction / ternimal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc for existing sub main wiring complete all as specified and directed.
Supply only in repair ceiling rose surface type bakelite 65 x 50mm with three terminals complete all as specified and directed.
Supply only in repair Modular fan regulator step type 120 W, 2 module complete all as specified and as directed.
Supply only in repair Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed.
Supply only in repair Switch Modular 6A single pole, two way, 1 module complete all as specified and as directed.
Supply only in repair Switch Modular 16A single pole, 1 module complete all as specified and as directed.
Supply only in repair socket Modular 6/16A 2/3 pin combined 2 module complete all as specified and as directed.
Supply only in repair Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed.
Supply only in repair modular white cover plate with frame 1 module complete all as specified and as directed.
Supply only in repair modular white cover plate with frame 2 mudule complete all as specified and as directed.
Supply only in repair modular white cover plate with frame 3 mudule complete all as specified and as directed.
Supply only in repair modular white cover plate with frame 4 mudule complete all as specified and as directed.
Supply only in repair modular white cover plate with frame 6 mudule complete all as specified and as directed.
Supply only in repair modular metal flush box 1/2 module complete all as specified and as directed.
Supply only in repair modular metal flush box 1/3 module complete all as specified and as directed.
Supply only in repair modular metal flush box 1/4 module complete all as specified and as directed.
Supply only in repair modular metal flush box 1/6 module complete all as specified and as directed.
Supply only in repair bell, Ding Dong AC, 230 volts, single pole all as specified and as directed.
Supply only in repair Switch piano, flush type single pole, one way 05 Amps complete all as specified and as directed.
Supply only in repair Switch piano, flush type single pole, one way 15 Amps complete all as specified and as directed.
Supply only in repair Socket outlet 3/5 pin, 06 Amps, flush type complete all as specified and as directed.
Supply only in repair multi socket outlet , 2 in 1, 3 pin, 16 Amps, flush type complete all as specified and as directed.
Supply only in repair switch socket combination, 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed.
Supply only in repair switch socket combination, 2 in 1, 3 pin, 6/16 Amps, flush type complete all as specified and as directed.
Supply only in repair stepped type electornic fan regulator (Switch/socket type) flush type on th existing phenolic laminated sheet etc complete all as specified and as directed.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulted FRLSH cable 1100 volts grade with multistranded copper conductor drawn through in existing conduit including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor, complete all as specified and as directed for One light point controlled by one, one way switch complete all as specified and as directed.
All as per item No. 45 here in before but for One switch socket outlet point controlled by one 06 Amp switch on independent board complete all as specified and as directed.
All as per item No. 45 described here-in-before but with copper conductor cable FRLSH 2.5 Sqmm for one 3 pin socket outlet, 16 Amps and including of FRLS 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board complete all as specified and as directed.
All as per item No. 45 described here-in-before but with copper conductor cable FRLSH 4 Sqmm for one 3 pin socket outlet, 16 Amps and including of FRLSH 4 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board complete all as specified and as directed.
Supply and fix MCB DB, SPN,4 ways, double door, 240 volt, Isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete all as specified and as directed.
Supply and fix MCB DB, SPN, 8 ways, double door, 240 volt, Isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete all as specified and as directed..
Supply and fix MCB DB, TPN, 4ways, double door, 440 volt, Isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete all as specified and as directed..
Supply only in repair MCB SP 6 to 32 Amps, 240Volts, 10 KA, "B" Curve complete all as specified and as directed.
Supply only in repair SPN 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete all as specified and as directed.
Supply only in repairs metal plug top 15 Amps 3 pin complete all as specified and as directed.
Supply only in repairs metal plug top 5 Amps 3 pin complete all as specified and as directed.
Material only for replaceing u/s capacitor for ceiling fan / exhaust fan / wall mounted fan / Air circulator for any type and size complete of capacity 2.5 mfd complete all as specified and as directed. Make : Havells, EPCOS, Crompton, Eletron
All as per Item No here-in-above but size of capacitor 3.15 mfd complete all as specified and as directed.
All as per Item No here-in-above but size of capacitor 4 mfd complete all as specified and as directed.
S&F in repair for unserviceable wiring complete with 1.5 sqmm single core PVC insulted FRLSH cable 1100 volts grade with multistranded copper conductor complete all as specified and as directed.
All as per Item No 59 here-in-above but size of cable 2.5 Sqmm complete all as specified and as directed.
All as per Item No 59 here-in-above but size of cable 4.0 Sqmm complete all as specified and as directed.
Cutting chases, pinning in. making good to facings where required and painting in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good matching with existing surface , cutting not exc 10 cm girth complete all as specified and as directed.
M/S VIGNESH POWER SYSTEM
SUPER COOL
UNIQUE INDIA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .