Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.4 CrAdmitted-Finance 13TH FLOOR DN18 SALTEE TECH PARK SECTOR V SALT LAKE BIDHAN NAGAR KOLKATA 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | -36.36% | ₹1.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.5 CrAdmitted-Finance | -33.00% | ₹1.5 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.5 CrAdmitted-Finance 2ND FLOOR PADMA TOWER 1 5 RAJENDRA PLACE NEW DELHI DELHI 110008 | WEST DELHI | DELHI | 110008 | -30.90% | ₹1.5 Cr | L3 | Admitted-Finance |
| 4 | L4₹1.7 CrAdmitted-Finance 11 E 379 11 PUL PEHLL 110044 | SOUTH EAST DELHI | DELHI | 110044 | -24.11% | ₹1.7 Cr | L4 | Admitted-Finance |
| 5 | L5₹2.0 CrAdmitted-Finance | -11.99% | ₹2.0 Cr | L5 | Admitted-Finance |
Updated dates
Tender Value
₹2.2 Cr
EMD Value
₹4.5 L
Closing Date
27 Mar 2026, 3:00 pmClosed
Executive Engineer Electrical Division-3
Executive Engineer Electrical Division-3, Siri Fort Road Behind Gargi College
SITC of LED sports Lights in Badminton Courts at Squash and Badminton Stadium.
2026_DDA_901535_1
77/EE/ELD-3/DDA/2025-26
Open Tender
Electrical Works
90 days
As Per Tender Document
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
₹4.5 L
SE (E)/East and Sports Vikas minar ITO
11 May 2026
6 Mar 2026
28 Mar 2026
6 Mar 2026
27 Mar 2026
10 Mar 2026
10 Mar 2026
SITC of DMX Controller System with Standalone interfaces. USB Connection - USB-24 DMX, Ethernet Connection - Ethernet-512 DMX, Output Channels - 1024(2X512,2U.Split x2)channels split on 2 outputs(PC and Stand Alone) Input - Ethernet(RJ45,DHCP or static IP),USB-C Networks - Ethernet, Internet, WIFI compatible when connected to a router, Node DMX - 4 ports Art-Net to DMX decoder and converter(DHCP, Static IP), DMX Modes - DMX In/Out, DMX Splitter(X4 ports),DMX Record, DMX Trigger, Multiple Zone - 5 Zone, play 5 scene/sequence per time in Stand Alone Art-Net Out - 2X512 on Ethernet(SD card required,2 universes per device), sACN Out - 2X512 on Ethernet(SD card required,2 universes per device) Memory capacity - Memory Step capacity(5K- 20K),8Mb Internal memory(NO SD required) Micro SD card – Micro SD Card(FAT format, max 256 GB, Class 10,Inside housing) Web Remote options - Web remote over internet, Housing I/O Connectors - Standard DIN-RAIL cabinet compatibility, PVC/USB-C, Screw terminal blocks with 2X9+2X6 pins, Number of Scenes - 2500, Number of Zones - 5 Power voltage - 5-24V DC,0.3A/Output:5VDC,High Voltage Protection, Power connectors - Screw Terminals, Standalone options - Art-Net and sACN from SD card, including triggers (4X512) - NODE to decode Art-Net and sACN to DMX(4 Universe), Setting & configuration via app - Commands from the contacts(Speed, Scene, Dimmer, Zone), Default start scene, Scene priority, Cross Fade time between scenes - Automatic Scene Recovery if the power is cut off and 16-bit and fine channel management App - Pixelerr Application(iOS, Andriod Free, LAN, INTERNET) RS 232 - RS 232 In/Out (16 characters max for RS232 triggers, commands or orders) Ethrnet - UDP/Ethernet triggers and commands(from SDK) Clock/Calendar - Real Time Clock and calender for each scene (Hour, Day, Week, Month,Year) Contacts - 12 Smart Contacts on 3- 5V(On, On/off, Release, Restart, Scene Priority, 31 contacts max) Commands - Commands from the Contacts(speed, scene, dimmer, zone) Input - DMX input(DMX signal from other DMX devices) Remote - Infrared Remote Light Intensity ART+NET, sACN - 2X152 with Pixelerr software and Output - 8X512 with Pixelerr Pro, DVI outputs - 128X128 or 16 384 pixels with - Pixelerr Pro Audio/Video Timeline - 30 mns Audio and Video Timeline Studio DMX - 3D viewer in real time(Full mode), Pixelerr Mobile App - Software control mobile(Andriod , iOS) Mobile - Andriod 5/iOS10 and + 1GHz CPU,1 GB RAM,60 MB disk minimum configuration -> System - Windows, Mac, iOS, Linux, Compatibility - Configuration minimal PC - Windows, Mac OS, Linux(32 and 64 bits) - 2Ghz CPU(2 core),8 GB RAM - 2GB RAM graphic card(for 3D only) - 600MB disk, 1920X1080 resolution 1 USB port(Device) - 1 Ethernet Port(for Art-Net & sACN), Along with Controller, additional Splitter as per suitable output ports & suitable enclosure for DMX controller & Splitter.
Supply and installation of FRP Junction box of size 150x150x100 mm with terminal suitable for terminating 4C x 2.5 sq.mm. copper cable upto 2 nos. and 1 no. 3Cx1.5 sq.mm flexible.
Supply of 1.1 kV grade 4Cx2.5 sq.mm, Copper conductor, XLPE insulated, PVC sheathed, armoured cable as per IS 7098 (Part-1) - 1988 (to latest amendment).
Supply of .1.1 kV grade 3Cx1.5 sq.mm, Copper conductor, XLPE insulated, PVC sheathed, armoured cable as per IS 7098 (Part-1) - 1988 (to latest amendment)
Supply, assembly, erection, connecting, testing & commissioning of LT weather proof dust and vermin proof, indoor feeder pillar/ panel with double door and IP 55 protection, fabricated out of suitable sized angle iron and flats and covered with 2mm thick CRCA sheet steel including canopy, powder coated, both sides (front and rear) openable with locking arrangement, rubber gasket cable glands, etc. Bakelite phase separators and bus bar supports on the existing truss with suitable mounting etc. as required. The feeder pillars shall be complete with 3 phase and neutral bus bars of capacities as described below and ACB,s and MCCB,s with adjustable overload relays for incomers and outgoing circuits ( including ON indication for each MCCB to be provided) , complete in all respects as per specifications as required INCOMER 150 A TP MCCB, Ics=36 KA WITHT.M RLS FOR O/L+S/C WITH ROH - 1 Nos Bus bar 4 strip aluminum bus bars of minimum of 250 Amps – 1 Set OUTGOING :- 32A, TP MCB, 10 KA (FOR Feeder Pillar) -4 Nos, 32A, TP MCB, 10 KA (COMNS) -2 Nos, For Spare 2A, SP MCB, 10 KA ( FOR PHASE INDICATING LIGHT ) -30 Nos, 32A TP CONTACTOR AC-3 DUTY -1 Nos ASTRO TIME SWITCH -1 Nos TOGGLE SWITCH MANUAL BYPASS -1 Nos PUSH BUTTONS RED+1 NC (UP & DOWN) -2 Nos IND. LIGHT 220V, LED TYPE,22.5mm DIA., RED, YELLOE, BLUE -1 Nos
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required a) upto 35 sqmm
Termination of following sizes of cables: a) 1.1 kV grade 4Cx2.5 sq.mm, Copper conductor, XLPE insulated, PVC sheathed, armoured cable as per IS 7098 (Part-1) - 1988 (to latest amendment).
b) 1.1 kV grade 3Cx1.5 sq.mm, stranded copper conductor, PVC insulated cable as per IS 694 - 1990 (to latest amendment).
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.12 MB
BOQ_947610.xls
BOQ • 6.45 MB
NIT.pdf
Tender Documents • 5.78 MB
Download all tender documents and submit your bid