Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | ₹6.2 L | L1 | Accepted-AOC satisfied |
| 2 | L2₹6.8 LRejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | ₹6.8 L | L2 | Rejected-Finance bidder is not L1 |
| 3 | L3₹7.2 LRejected-Finance MEGHNATH SAHA ROAD P O PANIHATI KOLKATA 700114 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700114 | ₹7.2 L | L3 | Rejected-Finance bidder is not L1 |
| Sl No | Description | Qty | Unit | Lyric International L2 | B. ENGINEERING CO. L1 | KAJAL CHANDRA L3 |
|---|---|---|---|---|---|---|
| 1.00 | SITC of Storage Water cooler with in-built UV +Cu Zn Purification and having following specifications as mentioned below: a) Approximate External Dimensions (WXDXH)- 640 x 560 x 1 420 mm; b) Input Voltage-230 V AC (50 Hz); c) Power Rating (Max)- 625W +/- l0%; d) Water Storage Tank Capacity -4O Ltr; e) Cooling Capacité at Com fort Level-60 LPH; f) Water flow rate through the faucet-17‘CT1”C; g) Refrigerant- HFC R 134 a; h) No. of Faucets-2; (Ampient & cool) i) No. of Stages for Filter cum Purifier-7; j) Active Copper Zinc Booster - Yes; k)B of Purified Water Recovery- 25%; l)% Rejection of TDS- 25%; m)Permeate (Purified Wa er) Production Capacity-50LPH; n)Storage Tank & Drain Tray Material - SS304; o)Outer Body Material - SS304
P) Type of Product Construction; Q)Type of Installation -Indoor; R) Net Weight-77 Kg
The Water cooler should also be equipped with other features like Purifier fault indication buzzer,visual controls switch,Water flow switch and UV Auto Shut off .
The machine should meet standard manufacturer's warranty. (Make-Eureka Forbes/Bluestar Limited ) | 5 | Nos | 1,09,000 ₹5.5 L | 1,06,816 ₹5.3 L | 1,14,900 ₹5.7 L |
| 2.00 | S/F of MS Structure platform for each water purifier cum cooler machine having suitable dimension and bearing capacity of 150kgs for keeping the Waterpurifier.The platform should be made up of 40 x40 x6 mm MS angle (for leg part ) and 75 x75x6 C Channel (for platform main structure ) and base plate of thickness 2.0mm and dimesion 0.1 x 0.1 mtr .Painting the structure by synthetic enamel paints of 2 coats (Priemer) and black japan 1 coat . Structual diagram should be approved by EIC | 120 | kg | 150 ₹18,000 | 90 ₹10,800 | 115 ₹13,800 |
| 3.00Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-Finolex/ KEI /RR Kabel) in 20mm size PVC rigid conduit 'FR' (Precision make ) incl. necy. fittings as required | ||||||
| 4.00 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC | 200 | mtr | 250 ₹50,000 | 79 ₹15,800 | 145 ₹29,000 |
| 5.00 | Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the 200 x150 x65 mm sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl.bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. | 5 | Nos | 500 ₹2,500 | 399 ₹1,995 | 328 ₹1,640 |
| 6.00 | Supply & Fixing 240 V 16/20 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required | 5 | Nos | 150 ₹750 | 90 ₹450 | 80 ₹400 |
| 7.00 | Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. | 5 | Nos | 150 ₹750 | 90 ₹450 | 80 ₹400 |
| 8.00 | Supply & Fixing 240 V, Red Neon Indicator (Anchor Penta 14601 or similar ) on existing sheet metal switch board after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. | 5 | Nos | 200 ₹1,000 | 100 ₹500 | 20 ₹100 |
| 9.00 | Charges for 2 years additional comprehensive AMC of above Water Cooler Machines after completion of 1 year DLP. | 5 | Nos | 12,500 ₹62,500 | 12,000 ₹60,000 | 21,000 ₹1.1 L |
| 10.00Rate should be quoted incl. of all taxes and cess. | ||||||
Tender Value
Refer Docs
EMD Value
₹15,600
Closing Date
17 Jan 2026, 2:00 pmClosed
EE-l CKHED PWD
Central Kolkata Health Electrical Division P-12, C.I.T Road(1st floor) Kolkata
Supply Installation Testing and commissioning of Water cooler cum Purifier along with allied electrical works at 4th to 9th floor of SHTO Building for Directorate of Drugs Control, Kolkata.
2025_WBPWD_981254_1
WBPWD/EE-I/CKHED/eNIT91/25-26
Open Tender
ELECTRICAL WORKS ORG
30 days
CENTRAL KOLKATA HEALTH ELECTRICAL DIVISION
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,600
Central Kolkata Health Electrical Division
13 Apr 2026
30 Dec 2025
19 Jan 2026
30 Dec 2025
17 Jan 2026
10 Jan 2026
5 Jan 2026
SITC of Storage Water cooler with in-built UV +Cu Zn Purification and having following specifications as mentioned below: a) Approximate External Dimensions (WXDXH)- 640 x 560 x 1 420 mm; b) Input Voltage-230 V AC (50 Hz); c) Power Rating (Max)- 625W +/- l0%; d) Water Storage Tank Capacity -4O Ltr; e) Cooling Capacité at Com fort Level-60 LPH; f) Water flow rate through the faucet-17‘CT1”C; g) Refrigerant- HFC R 134 a; h) No. of Faucets-2; (Ampient & cool) i) No. of Stages for Filter cum Purifier-7; j) Active Copper Zinc Booster - Yes; k)B of Purified Water Recovery- 25%; l)% Rejection of TDS- 25%; m)Permeate (Purified Wa er) Production Capacity-50LPH; n)Storage Tank & Drain Tray Material - SS304; o)Outer Body Material - SS304 P) Type of Product Construction; Q)Type of Installation -Indoor; R) Net Weight-77 Kg The Water cooler should also be equipped with other features like Purifier fault indication buzzer,visual controls switch,Water flow switch and UV Auto Shut off . The machine should meet standard manufacturer's warranty. (Make-Eureka Forbes/Bluestar Limited )
S/F of MS Structure platform for each water purifier cum cooler machine having suitable dimension and bearing capacity of 150kgs for keeping the Waterpurifier.The platform should be made up of 40 x40 x6 mm MS angle (for leg part ) and 75 x75x6 C Channel (for platform main structure ) and base plate of thickness 2.0mm and dimesion 0.1 x 0.1 mtr .Painting the structure by synthetic enamel paints of 2 coats (Priemer) and black japan 1 coat . Structual diagram should be approved by EIC
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make-Finolex/ KEI /RR Kabel) in 20mm size PVC rigid conduit 'FR' (Precision make ) incl. necy. fittings as required
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the 200 x150 x65 mm sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl.bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
Supply & Fixing 240 V 16/20 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
Supply & Fixing 240 V, Red Neon Indicator (Anchor Penta 14601 or similar ) on existing sheet metal switch board after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
Charges for 2 years additional comprehensive AMC of above Water Cooler Machines after completion of 1 year DLP.
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1 year
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
technical_2393123.pdf
techsummary_2393123.pdf
finance_2393123.pdf
BOQ Comparative Chart
xlsx
finsummary_2393123.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.18 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_2393123.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid