Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.4 CrAdmitted-Finance ANWALKHEDA MR | -0.12% | ₹1.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.4 CrAdmitted-Finance | -0.10% | ₹1.4 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.4 CrAdmitted-Finance | +0.00% | ₹1.4 Cr | L3 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹2.8 L
Closing Date
5 Feb 2026, 5:00 pmClosed
EO NPP SAMTHAR
NPP Samthar
NPP Samthar me Kanha Gaushala ka Nirman
2026_DOLBU_1105896_1
632/npp/nirman/2025-26
Open Tender
Civil Works
180 days
Degree College
Please refer Tender documents.
2 documents required · 2 mandatory
₹41,721
Yes
EO NPP Samthar
₹2.8 L
6 Feb 2026
17 Jan 2026
6 Feb 2026
17 Jan 2026
5 Feb 2026
17 Jan 2026
Construction of Kanha Gaushala
Excavation in Foundation in ordinary soil including lift upto 1.5 metre and lead upto 30 m and including filling watering and ramping of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by Engineer-in- Charge upto a distance of 30 m from the foundation trenches.
Cement concrete with 4 cm gauge approved stone ballast approved coaarse sand and cement in the proportion of 1:3:6 incluning supply of all materials labour and T&P etc. required for proper completion of the work
Providing and laying in position machine batched and machine mixed design mix 1:2:4 cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS:1791 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement: 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel work in built up trusses , anchor bolt etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Providing and fixing precoated galvanised iron profile sheet Roofing including vertical / curved surface fixed with polymer coated J& L hooks bolts and nuts 8mm diameter with bitumen and G,I limpet washers or with white lead including a coat of approved steel primer and two coats of approved paint on overlaping of sheet complete and should be supplied in single length up to 12 meter or as desired by engineer in charge. The sheet shall be fixed using sef drilling/self tapping screws of size (5.5x55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the coat of purlin, rafter and trusses and including cutting to size and shape wherever required. G.S.Sheet .63 mm thick with zinc coating not less than 275 gm/sqm
Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.I. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes.a) 110mm diameter
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
12.5 mm thick cement plaster 1:4 in internal plaster
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
Brick work with common burnt clay F.P.S. (non modular) for wall of one bricks thick in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Providing and laying in position machine batched and machine mixed design mix 1:1.5:3 cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS:1791 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
Centering and shuttering including strutting, propping etc. and removal of form for suspended floor, roof Lintel, beam, plinth beam columns, etc. for mass concrete
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm,which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat.
Providing and laying 8-10 mm thick Vitrified tiles of 300 X 300 mm in flooring, rissers of steps ,skirting ,dado 10 mm thick in base of cement mortar 1:4 laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including polishing complete.
Providing and fixing 1 mm thick MS sheet garage door with frame of 40 x 40 x 6 mm angle iron 3.15 thick ms gusset plates at the juncton corners including supply and fixing of necessary fitting complete all as per direction of Engineer-in-charge.
Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :(Flat back wash basin of size 550x400 mm)
White glazed earthenware european type wc pan with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fitting and ci brackets 40 mm flush bend overflow arrangement with specials of standard make it complete.
Providing anf fixing 8 mm dia C.P/ S.S jet with Flexible tube upto 1 metre long with S.S triangular plate to european type WC of Quality and make as approved by Engineer in charge.
Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
providing and fixing toilet paper holder
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
Providing and fixing C.P. brass angle valve of approved quality conforming to IS:8931 :
Providing and fixing in position 100 mm dia sand cast iron S&S pipe including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.Providing and fixing of bend of required degree
Providing and fixing in position 100 mm dia sand cast iron S&S pipe including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.Providing and fixing of plain bend of required degree
Providing and fixing of collar
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 110mm o/d pipe of 10 Kgf. / sqcm
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects.Inside size 75x120 cm and 120 cm deep
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. CPVC SDR 11 Pipe & fitting 20mm o/d
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. CPVC SDR 11 Pipe & fitting 25mm o/d
Cement concrete with 4 cm gauge approved stone ballast approved coaarse sand and cement in the proportion of 6:3:1 incluning supply of all materials labour and T&P etc. required for proper completion of the work
Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 25 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and fixing G.I. chain link fabric fencing of 1.5 m high required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.Made of G.I. wire of dia. 4 mm, PVC coated to achieveouter dia not less than 5 mm in required colour and shade
Providing and laying in position machine batched and machine mixed design mix 1:1.5:3 cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS:1791 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
R.C.C standards post struts/ rail/ pales of mix 1:1.5:3 with wooden plug or 6 mm bar nibs wherever required as per direction of engineer in charge.
Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage & overlapping & hooks. Si. No. 504
Solar Ligth semi intergrated street light 15 Wp LifeP04 24 AH Solar Panel 75 Wp with 6 Mtr Pole and installation and Commissioning
septic tank
Bio Gas Plant
Tube well
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
BOQ_2040508.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid