Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.9 L+₹4.1 L (24.3%)Rejected-Finance 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹27.0 L+₹10.2 L (60.5%)Rejected-Finance BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹27.3 L+₹10.5 L (62.3%)Rejected-Finance KALU BASS SHRI DUNGARGARH BIKANER RAJASTHAN 331803 | BIKANER | BIKANER | RAJASTHAN | 331803 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹29.9 L+₹13.1 L (78.2%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Maj Mathews M Shepherd
GE (WEST) MATHURA
REPAIR MAINT OF SUBMERSIBLE PUMPS MONO BLOCK PUMP UNDER GE WEST MATHURA
2024_MES_663032_1
8300/1252/E8
Open Tender
Pumps/Motors
Item Rate
180 days
GE (WEST) MATHURA
Pl ref Tender Documents
10 documents required · 10 mandatory
₹500
GE (West) Mathura
₹60,000
Yes
28 Oct 2024
18 Jul 2024
20 Sept 2024
18 Jul 2024
12 Sept 2024
1 Aug 2024
Amount
Lifting of Borewell pump motor set 5HP to 20 HP from 40 Mtr depth (approx.) including and upto 100mm dia column pipe, shaft assembly, dismantling the pump set complete with the help of chainpully block and other T&P as required at site all complete all as specified and directed.
M & L for cleaning of borewell of size 150 mm to 250 mm with the help of air compressor and water jet by overflowing the silt deposited in the borewell without damaging the exiting casing pipe and perforated pipe any size of depth upto 60 mtr and disinfecting the borewell with the help of calcium hypochlorite based granulars. Note:- (i) Borewell will be cleaned till the entire satisfaction of JE/Engr-in-Charge. (ii) Cost of water bozer required for overflowing the silt will be included in the quoted rate.
Lowering of Borewell pumpmotor set 5 HP to 20 HP upto 40 Mtr depth (approx.) including and upto 100mm dia column pipe, shaft assembly, with the help of crane and other T&P as required at site complete with replacement of wornout / rusted nuts and bolts, painting to column pipe with one coat of rubber based paint, complete commissioning and testing for 8 Hrs continuous upto satisfaction complete all as specified and directed. Note:- Nut bolts, paint and T & P required to be replaced will be included in the quoted rate.
Supply, installation, jointing and testing in replacement cast iron column pipe 7mm thickness of size 200 mm dia dia with all fitings including welding and anytype of fitting required to make a joint all as specified and directed.
Supply, fixing and installation PVC Pipe 10 Kg/cm2 pressure of size 100 mm in replacement of old rusted broken PVC pipe of size 100 mm and jointing by socket, bend, tee or any type of PVC fitting all as specified and directed by Engr-in-Charge.
Supply, fixing and installation PVC Pipe 10 Kg/cm2 pressure of size 50 mm in replacement of old rusted broken PVC pipe of size 50 mm and jointing by socket, bend, tee or any type of PVC fitting all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 pole 320 Amps, 415 volts, type 36 KA breaking capacity with adjustable thermal & magnatic setting complete all as specified and directed.
M&L in replacement starter 30HP with direct on line submersible pump PSE18 soft starter three phase star delta fully automatic 30 HP, overload relay range 32-104 (Amp) equivalent to ABB 1SFC132369M9901 or equivalent in make specified in Appendix 'B' complete all as specified and directed.
Labour and T&P for lifting of submersible pump set 30HP from 60 Mtr depth (approx.) including column pipe, Submersible cable complete with the help of chainpully block and other T&P as required at site transporting to civil workshop for repair & back after repair, lowering including replacement of rubber sheet, nuts & bolts connecting to existing system and testing on full load complete all as specified and directed.
M&L for rewinding submersible motor 30 HP three Phase, 415 volts, 50 Hz A/C with insulated copper wire of existing gauge including all insulating materials, complete assembling, connecting and testing on full load complete all as specified and directed.
M&L for rewinding and refixing after rewinding the same motor of Centrifugal pump of capacity 25 HP, three phase 415 volts, 50Hz AC with super enameled copper winding wire of suitbale size and gauge including insulating material, heating drying,re-assembling and testing complete all as specified and directed by Engineer in Charge.
Labour and T&P for lifting of submersible pump set 2 HP to 15HP from 40 Mtr depth (approx.) including column pipe, SB cable complete with the help of chainpully block and other T&P as required at site transporting to civil workshop for repair & back after repair, lowering including replacement of rubber sheet, nuts & bolts connecting to existing system and testing on full load complete all as specified and directed.
Dismantling of submersible pump & motor of any capacity, any description and replacement of worn out/rusted nuts & bolts, reassembling after repair, connecting and testing all as directed. Note : (i) Rate of taking down of old unserviceable spare parts shall be included in quoted rate of this item. (ii) Supply of spare parts shall be measured and paid seperately under respective items.
Supply only PVC impeller suitable for 2 HP SB pump complete all as specified and directed.
Supply only SS impeller suitable for 5 HP SB pump complete all as specified and directed.
Supply only SS impeller suitable for 7.5 HP SB pump complete all as specified and directed.
Supply only SS impeller suitable for 10 HP SB pump complete all as specified and directed.
Supply only SS impeller suitable for 12.5 HP SB pump complete all as specified and directed.
Supply only SS impeller suitable for 15 HP SB pump complete all as specified and directed.
Supply only complete shaft sleeve (Bush) suitable for 2 HP SB pump complete all as specified and directed.
Supply only complete shaft sleeve (Bush) suitable for 5 HP SB pump complete all as specified and directed.
Supply only complete shaft sleeve (Bush) suitable for 7.5 HP SB pump complete all as specified and directed.
Supply only complete shaft sleeve (Bush) suitable for 10 HP SB pump complete all as specified and directed.
Supply only complete shaft sleeve (Bush) suitable for 12.5 HP SB pump complete all as specified and directed.
Supply only complete shaft sleeve (Bush) suitable for 15 HP SB pump complete all as specified and directed.
M&L for rewinding submersible motor 2 HP, single phase, 230 volts, 50 Hz A/C with insulated copper wire of existing gauge including all insulating materials, complete assembling, connecting and testing on full load complete all as specified and directed.
M&L for rewinding submersible motor 5 HP, three phase, 415 volts, 50 Hz A/C with insulated copper wire of existing gauge including all insulating materials, complete assembling, connecting and testing on full load complete all as specified and directed.
M&L for rewinding submersible motor 7.5 HP three Phase, 415 volts, 50 Hz A/C with insulated copper wire of existing gauge including all insulating materials, complete assembling, connecting and testing on full load complete all as specified and directed.
M&L for rewinding submersible motor 10 HP three Phase, 415 volts, 50 Hz A/C with insulated copper wire of existing gauge including all insulating materials, complete assembling, connecting and testing on full load complete all as specified and directed.
M&L for rewinding submersible motor 15 HP three Phase, 415 volts, 50 Hz A/C with insulated copper wire of existing gauge including all insulating materials, complete assembling, connecting and testing on full load complete all as specified and directed.
Supply & fixing / lowering in replacement of uPVC / HDPE pipe heavy duty ISI marked of size 100mm dia, complete all as specified and directed.
Supply & replacement of MS column pipe heavy duty ISI marked of 80 mm bore, 3.0 mtr long both end threaded with one socket suitable for Submersible pump sets complete all as specified and directed.
Supply & replacement of MS column pipe heavy duty ISI marked of 100 mm bore, 5.4 mm thick, 3.0 mtr long both end flanged with nut bolts packing sheet suitable for Submersible pump sets complete all as specified and directed.
Supply, install and testing in replacement monoblock pump motor copper winding 1.5KW/2 HP all as specified and directed. Note: Old submersible pump will be deposited to AGE E/M (W) Yard after removable.
M&L for in replacement starter 5HP with direct on line submersible pump starter three phase star delta fully automatic 5 HP, 3.7 KW, overload relay range 9-13 (Amp) complete all as specified and directed.
M&L for in replacement starter 10HP with direct on line submersible pump starter three phase star delta fully automatic 10 HP, 7.5 KW, overload relay range 17-25 (Amp) complete all as specified and directed.
M&L for in replacement starter 12.5HP with direct on line submersible pump starter three phase star delta fully automatic 12.5 HP, 9.3 KW, overload relay range 17-25 (Amp) complete all as specified and directed.
M&L for in replacement starter 15HP with direct on line submersible pump starter three phase star delta fully automatic 15 HP, 11 KW, overload relay range 23-32 (Amp) complete all as specified and directed.
Supply and laying in replacement PVC copper cable FRLS 10 Sqmm single core laid in open with the help of saddles of suitable size alongwith nut bolts all as specified and directed.
M&L for in replacement submersible copper cable flat three core PVC insulated & PVC sheathed industrial cable for submersible pump motors three core nominal area of conductor size 6 Sqmm complete all as specified and directed.
M&L for in replacement submersible copper cable flat three core PVC insulated & PVC sheathed industrial cable for submersible pump motors three core nominal area of conductor size 10 Sqmm complete all as specified and directed.
M&L for repairing of sluice valve with opening and taking out old unservercible defective spindle and refix the same after taking out the spindle transporting to workshop for machine work in only old gun metal/stainless steel spindle by making new threads on lathe machine with check nut, rubber gasket, gland packing, nuts & bolts all as required at site and directed by Engineer-in-charge for the following sizes:-
100mm dia bore
150mm dia bore
200mm dia bore
250mm dia bore
125mm dia bore
M&L for maintenance and up keeping of all pump, motor and LT panels install inside any pump station the contractor is deemed to provide following:- (i) Checking and maintenance of all connections gauges etc all pump sets 50 HP capacity and endorse the status in register. (ii) Checking and maintenance of voltage meters, Amp meters and checking of RYB phase indicators, CTS incl all electrical connection of LT panel incl endorse the status in register. (iii) Checking and maintenance of leakage of transformer oil from starters all connections of moving auxillary, contacts coil, relays etc in all respect of oil immersed and electronic starters. Cont/-
Cont/- (iv) Arresting of leakage from pumps, sluice valves by filling gland etc and make the pump set leak proof. (v) Maintaining the allingment of pumpsets, maintaining the vibrations by filling necessary gland packing and allied works for avoiding the loss of pump sets due to mechanical faults and electrical faults to prevent the motor winding burning, damage of pump shafts, coupling, casing of pump sets etc and restrict the abnormal sounds in pump sets. Cont/-
Cont/- Note: (a) The necessary gland packing, rubber insertion sheets, insulation tape, grease, oil and nut bolts of any size shall be provided by the contractor and rates quoted deemed to. (b) T&P helpers for repair and maintenance are responsibiltiy of contractor without any extra cost. (c) Any defect found and not intimated by the technician, penalty of Rs. 5000 or cost of defect rectification which one is feasible will be accounted.
M&L for in repair of LT panel by replacement of the following items:- Note:- Panel shall be repaired by skilled technician having good knowledge of panel.
Copper cable PVC single core unarmoured unsheathed of size 25 Sqmm.
Copper cable PVC single core unarmoured unsheathed of size 2.5 Sqmm.
CT, resin casted of current ratio 400/5 Amp, burden -15 VA, accuracy class 1.0
Phase indicator R,Y,B as per existing size and shape.
MCCB - 125 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection / setting, Ics=100% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In
MCCB - 250 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection/setting, Ics=100% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In
MCCB - 400 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic protection/setting, Ics=100% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In
Electronic timer-minilac
Terminal plate 06 Nos
Single Phase preventer
Copper lugs, thimbels, bottel lugssize of 25 Sqm
Contactor 25 Amps as per existing
Relay suitable for starter 10 to 15 HP-Minilac
Supply and laying in replacement PVC copper cable 3 core 1.5 sqmm with PVC pipe laid in bridge with the help of saddles of suitable size alongwith nut bolts complete all as specified and directed.
S&F in replacement MCB Triple pole & neutral, 415 Volts, 63 Amp complete all as specified and directed.
S&F in replacement PVC cables copper conductor insulated and unsheathed multistranded single core of size 70 sqmm 1100 V including copper lugs complete all as specified and directed.
S&F in replacement PVC cables copper conductor insulated and unsheathed multistranded single core of size 50 sqmm 1100 V including copper lugs complete all as specified and directed.
S&F framed work such as grill gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters walk ways railing frame work of ceiling etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
Supply & laying in replacement cable, 1100 volts grade heavy duty with XLPE insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 120 Sqmm x 3.5 core size including fixing in Open with the help of saddles and nut bolt of suitable size all as specified and as directed.
S&F in replacement of MCCB 4 pole 800 Amps, 415 volts, 70 KA rupturing capacity with adjustable thermal & magnatic setting complete all as specified and directed.
Supply and laying new electrical insulation rubber matting as per ISI and size 1mtrx 2mtr x 19mm suitable for electric installations/ panel boards tested suitable complete all as specified and directed.
S&F in repair Contactor 95 Amp 3 Pole 415 Volt complete all as specified and directed.
S&F in repair Contactor 70 Amp 3 Pole 415 Volt complete all as specified and directed.
Supply & fixing in replacement of worn out starter with fully automatic star delta (FASD) starter/controller suitable for 20 HP, 3 phase, 415 volt AC, AC-3 duty induction motor in sheet steel enclosure with IP 54 protection to changeover from star winding to delta winding with the help of electronc timer, having ON/OFF operation and overload protection with additional features like Auto ON (with 30 sec ON Delay), indications of supply ON/OFF and pump ON/OFF, reading of real time voltage & current of pump with unique dual analog meter, single phasing protection relay (SPPR), relay range 66 to 110 Amp, wide band coil operation from 65% to 110% of rated coil voltage - 380/415 Volt, phase-reversal protection, phase-unbalance protection, variable time-delay adjustment inside controller complete in all respect and conforming to IS/IEC 60947-4-1 standards complete all as specified and directed.
M & L for lifting fallen submersible pump and motor upto 15 HP alongwith Column pipe upto 150 mm from deep borewell approx 60 mtr height with the help of stud tripod, gantry crane, hooks, shackles without damaging the existing borewell casing and submersible pump and motor alongwith column pipe all as specified and directed.
Supply and fix Single phase motor 2780 RPM of capacity 0.75KW/1.00HP, pressure booster pump rated discharge approx 1500 LPH at rated head 40 m suction discharge of pump 25x25 mm alongwith Pressure tank of capacity 24 litre all as complete all as specified and directed.
Supply installatin and testing in replacment horizontal type submersible pump motor copper winding 0.5 HP all as specified and directed. Note : Old unserviceable submersible pump will be deposited to AGE E/M (W) store yard.
S&F in repair MNX Contactor 110 Amp 3 Pole 415 Volt complete all as specified and directed.
Supply & fixing in replacement of GI pipe heavy duty ISI marked of size 50mm dia,both end flanged including nuts & bolts packing sheet complete all as specified and directed.
shyam construction (BID ID -3087893)
prabhave traders (BID ID -3087634)
M/s R L PAREEK (BID ID -3094028)
iswar enterprises (BID ID -3087018)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .