Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | L1 | Accepted-AOC lowest tender | |
| 2 | L2₹11.3 L+₹2.1 L (22.1%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹11.5 L+₹2.3 L (24.4%)Rejected-Finance FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹12.4 L+₹3.1 L (33.2%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
23 Mar 2024, 6:00 pmClosed
GE (AF) ADM AREA
GE (AF) ADM AREA GWALIOR-474020
REPAIR/REPLACEMENT AND MAINTENANCE OF COOLING APPLIANCES INCLUDING REPLACEMENT OF WORN OUT ACCESSORIES OF DESERT COOLER, WATER COOLER, REFRIGERATOR, DEFREEZER AND VOLTAGE AT AF STN GWALIOR
2024_MES_643137_1
8386/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) ADM AREA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) ADM AREA
₹38,000
Yes
30 Mar 2024
19 Feb 2024
30 Mar 2024
19 Feb 2024
23 Mar 2024
4 Mar 2024
Amount
PART-I (WATER COOLER) Disconnecting, dismantling and taking out the non-functional Water coolers of any description, any make and in any position, capacity 40 ltr to 150 ltr, including water connections, single phase, 50 Hz, strip opening, cleaning and servicing of the water cooler with using MAIC-DS solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing, reassembling water cooler, restoring water supply connections and testing of the water coolers complete as all specified and directed by Engineer–in–charge. NOTE(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’/BOQ and fixing charges for new/ repaired items are deemed to be included under this item.(ii) Replacement of unserviceable / damaged body portions of the water coolers shall also be measured and paid for separately under appropriate item of Schedule `A' as supply only but fixing/assembling element of new / repaired body parts with existing parts is deemed to be included under this item. (iii) Burnt out windings and internal wiring, if any, replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding & supply only of internal wiring kit. (iv) The rates for above items are deemed to include for transportation to & fro of Water coolers to workshop as approved by Engineer-in-charge for necessary repairs and testing of Water coolers at workshop & replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one. (v) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, shall be included in the unit rate quoted by the contractor for this item (vi) Rates quoted by the contractor for this item are also deemed to be included for de-scaling of chilled water pipe line including brazing of damaged portion of pipe line.
Supply and Charging of refrigerant Gas R-22 Mono chloro difluoro methane (CHCLF2) to make up the required pressure complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair single pole and nuetral sheet enclosure with two pin and earth plug and socket complete and including for with one single pole MCB 20 amp, 240 volts complete all as specified and directed.
Supply only base Tray Stainless steel 40/60 ltr capacity water cooler of any make all as specified and directed by Engineer-in-charge.
All as per item No 3.02 here-in-before but of capacity 60/120 ltr.
Supply only side cover stainless steel 40/60 ltr capacity water cooler of any make for water cooler complete all as specified and directed by Engineer-in-charge.
All as per item No 3.04 but of capacity 60/120 ltr.
Supply only water storage tank with chiller as per existing capacity complete made of stainless steel suitable for 40/60 ltr. capacity including copper tube suitable for any make , complete all as specified and directed -by Engineer-in-Charge.
All as per item No 3.06 here-in-before but of capacity 60/120ltr.
Supply only PVC Gasket non- magnet for chiller top any make of water cooler including fixing arrangement complete all as specified and directed.
Supply only Air cooled condenser with ventury, copper tube, 3 row , suitable for any type of refrigerant gas, 60/120 ltr. capacity suitable for Make Blue star/ Voltas / Usha/ Shriram water coolers, complete all as specified and directed.
Supply only relay unit current type
Supply only relay pin type (Potential type)
Supply only starting capacitor 40/60 MFD
Supply only capacitor 60/80 MFD
Supply only capacitor 80/100 MFD
Supply only Running capacitor 10 to 15 MFD (Make : Syscap / Asian/ Epcos)
Supply only Running capacitor 20 to 36 MFD (Make : Syscap / Asian/ Epcos)
Supply only Thermostat , 220 volts suitable for Make Blue star/ Voltas / Usha Shriram water coolers, complete all as specified and directed Make : Indfoss / Renutrol/ Rockwell
Supply only over load protector (Suitable for any make / model of compressor) complete all as approved by Engineer-in-Charge
Supply only AC electric condenser motor 25 Watt, 230 Volts, 1250 RPM single speed complete all as specified and directed.
Supply only AC electric condenser motor 30 to 35 Watt, 230 Volts, 930 RPM single speed complete all as specified and directed.
Supply only AC electric condenser motor 75 to 90 Watt, 230 Volts, 1400 RPM single speed complete all as specified and directed.
Supply only brass Nipple 15 mm dia for inlet and out let connection of water cooler any type / size including one PVC connection 15 mm dia with brass coupling on both ends.
Supply only Drain Pipe PVC flexible 1¼” dia with one end circle clip complete all as specified and directed.
Supply only wiring kit of flexible PVC insulated copper conductor cable of existing size complete all as specified and directed
Supply only CP brass Push cock, 15 mm. Dia (ISI marked) inner/outer threaded complete all as specified and directed
Supply only new sealed unit compressor for water coolers of existing make and model, as approved by GE including vacuum testing and filling of Refrigerant Gas to required pressure complete all as specified and directed by Engineer - in - charge for the following capacity :-
(a) compressor suitable for 40 ltr capacity water cooler
(b) compressor suitable for 60 ltr capacity water cooler
(c) compressor suitable for 120 ltr capacity water cooler
(d) compressor suitable for 150 ltr capacity water cooler
Note for item No 4.01 & 4.04 : (i) The cost of fixing, brazing to suction and discharge line and testing of compressor at site shall be included in quoted rate of Schedule `A'/BOQ item No.1.00 here-in-before. (ii) Refrigerant gas for charging of compressors shall be measured and paid for separately under respective item of this Schedule.
Supply and fixing in repair fan blade of any type and any description suitable for water cooler of capacity 40 Ltrs complete all as specified and directed.
Supply and fixing in repair fan blade of any type and any description suitable for water cooler of capacity 60 Ltrs complete all as specified and directed.
S&F in repair PVC connection 15mm dia bore, 450mm long with both ends brass screwed socket and having high density pressure pipe . complete all as specified and directed by Engineer - in- charge.
PART- II (REFERIGERATOR) Disconnecting and taking out the non-functional Refrigerator of any description and in any position, strip opening of Refrigerator 165 Ltr. to 330 Ltr. Capacity, cleaning and servicing, taking out un-serviceable / defective parts/spares and internal wiring, replacement of un-serviceable parts/spares like Relay, capacitor, wiring , over load protector, Compressor, inner liner Puff, evaporator, freezer, condenser, Lamp & holders etc. necessary brazing, reassembling and testing all as specified and directed by Engineer-in-charge. Note- (i) Replacement of un-serviceable parts shall be measured and paid for separately under appropriate item of sch ‘A’ as supply only but fixing and testing charge of the parts replaced / repaired shall be included in quoted rate of above item. (ii) The rates for above items shall include for transportation to & fro of Refrigerators to workshop as approved by Engineer-in-charge for necessary repairs and testing of Refrigerators at workshop & replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one (iii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, shall be included in the unit rate quoted by the contractor for this item
Supply only following new parts suitable for refrigerator of existing make and desciption and capacity 165 ltr to 420 ltr :-
Main door gasket magnetic type suitable for any type of Referigerator.
Thermostat switch with knob 230 volt suitable for single door refrigerator of make. (Make Indofos/ Godrej/Annapurna)
Thermostat switch with knob 230 volt suitable for double door refrigerator 230 to 350 ltr. (Make Indofos/ Godrej/Annapurna)
Relay Box type 220 volt 3 pin / 4 pin (Make KCL / Renutrol / Indofos).
Freezer door with spring & clamp suitable for existing refrigerator of existing description and capacity.
Pin type / screw type bulb suitable for 165 ltr. to 460 ltr. Refrigerator (Make : Philips ).
Compressor water drain off tray of PVC as approved
Door switch 230 volt
Chiller tray plastic
Refrigerator Freezer coil & freezer coil type/roll bound type complete suitable for 165 ltr. to 230 ltr. capacity
Bulb holder assembly complete as per existing model
Supply only condenser coil suitable for 165 to 230 ltr capacity refrigerator of any description suitable for any model & make of LG/ Whirlpool/ Samsung.
Supply only fan motor of frost free suitable for double door refrigerator of capacity 300 Ltrs to 420 Ltrs directed by Engineer-in-Charge. suitable for refrigerator of Make : LG / Whirlpool/Samsung
Supply only bi-metal thermostat of capacity – 5 0 C cut in temperature suitable for 300 Ltrs to 360 Ltrs refrigerators of Make : LG / Whirlpool/ Samsung
Supply only fuse for bi- metal thermostat of 650C / 700C suitable for 300 to 360 Ltrs refrigerators
Supply and charging of refrigerant gas 134A to make up the required pressure in any type refrigerator.
Supply only the following new sealed unit compressor for refrigerator of existing make/model as approved by GE including vacuum testing and filling of Refrigerant Gas to required pressure.
Refrigerator Compressor make : Godrej (Model No NAE-6, NAE-8), /Tecumseh (model No 1333, 1343) / Voltas (Model No DFC1, DFC2),
Refrigerator compressor
PART- III (DESERT COOLER) Disconnecting and taking out the defective / non-functional desert cooler of any description and in any position and any floor installed at direct approach ( where any ladders and other T&P are not required to remove the desert cooler from position), strip opening of desert cooler, cleaning, servicing, oiling & greasing etc of desert cooler, taking out and removing unserviceable / defective parts and internal wiring, replacement of unserviceable & damaged parts and internal wiring, re-assembling & testing of the desert cooler all as specified and directed by Engineer-in-Charge Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item .and replacement of unserviceable / damaged body portions i.e. panels / switch board / bottom / top / grills / frame etc. of the desert cooler shall also be measured and paid for separately under appropriate item of Schedule `A'. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & fro of vertical pumps/fan motors to workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop & replacement of necessary unserviceable screws/nuts/bolts/washers/ packing etc with new one.
Supply only PVC flexible water Pipe 15 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply only PVC distributor 3 way, suitable for 15mm dia water distribution all as specified and directed by Engineer-in-Charge.
Supply only new 3 core PVC insulated copper cable size 23/0.0076 round 1100 volt grade as in connection to desert coolers all as specified and directed by Engineer-in-Charge. (Make : plaza / Finolex )
Supply only shaft for fan motor of desert cooler all as specified and directed by Engineer-in-Charge.
Taking out & removing old existing plywood of any description and in any position and supplying and fixing new plywood 4mm thick, grade BWR, type BB, 3 ply, cut to size made to shape and fixed in position with nails as to make the window of desert cooler air tight complete all as specified and directed by Engineer-in-Charge. (Make : Kitply / National/ Bhutan )
Supply only Air curtain panels (side and back removable panels) of any description and size for different size of desert coolers, made to shape and size with using 20 SWG gauge PGI sheets as per requirement including necessary mouldings etc to suit the existing cooler openings all as specified and directed by Engineer-in-Charge.
Supply only water Pump, 230 volts, 45 watt, 1400 RPM all as specified and directed by Engineer-in-Charge.(Make : Crompton / AUE / Khaitan/ Bajaj
Supply only cooler fan kit (suitable for three fan blades) 230 volt 1/8 HP. 950 RPM, double ball bearing type all as specified and directed by Engineer-in-Charge. (Make Crompton /AUE/ Khaitan / Bajaj)
Supply only cooler exhaust fan motor (suitable for three fan blades) 230 volt 1/8 HP. 950 RPM, double ball bearing type all as specified and directed by Engineer-in-Charge. (Make Crompton /AUE/ Khaitan / Bajaj)
Supply only cooler fan motor for plastic body coolers (suitable for three fan blades) 230 volt 1/8 HP. 950 RPM, double ball bearing type all as specified and directed by Engineer-in-Charge. (Make symbhony/Crompton /AUE/ Khaitan / Bajaj)
Supply only aluminium fan blade ( set of three blades) for cooler motor of any description to suit existing motor all as specified and directed by Engineer-in-Charge. .
Supply only plastic fan blade ( set of three blades) for cooler motor of any description to suit existing motor all as specified and directed by Engineer-in-Charge. .
Replacement of damaged / unserviceable chicken wire mesh with using new hexagonal wire mesh having 15mm size mesh and 0.5mm dia of wire for supporting to the wood wool pads all as specified and directed by Engineer-in-Charge.
M&L for Providing new wood wool pads of required size as approved (three in each on desert cooler) complete material and labour all as specified and directed by Engineer-in-Charge.
M&L for Replacement of existing unserviceable front grills of any description and in any position with supplying and fixing new grills of existing shape and size and made out of 20 SWG, PGI sheet complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 15mm dia Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule all as specified and directed by Engineer-in-Charge.
Supply and fixing 15mm dia Gun metal or gate valves, with iron wheel head, screwed, both end for iron pipe all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC connection 15mm size 450mm length complete with PTMT nuts on both ends all as specified and directed by Engineer-in-Charge.
Taking down old / unsv/rusted GI tubing of 15/20 mm dia and S&F GI tubing (ISI Marked) 20 mm dia with including all fittings such as sockets, TEE,elbow, union etc all as specified and directed.Make TT Swastic/Jindal/TATA
Supply and fixing plug top 15 amp 3 pin ,215 volts .
Supply and fixing plug top 05 amp 3 pin ,215 volts .
PART-IV ( VOLTAGE STABILISER) Disconnecting & taking out the non-functional voltage stabilizer of any description and in any position & strip opening of Voltage Stabilizer of 200 250 KVA three phase, air cooled, (MAKE : Blue line/ Blue bird/Citizen and AE), taking out unserviceable/defective wiring & parts, cleaning and servicing complete including replacement of unserviceable parts with new one and unserviceable wiring with new PVC insulated and unsheathed stranded copper conductor cable of existing size, reassembling ,connecting and testing including cleaning the exposed surfaces of stabilizers & applying a coat of synthetic enamel paint after preparation of old painted steel surfaces and writing MES No/SM No in different tint in the pattern & style all as directed by Engineer-in-Charge complete all as specified and directed.Note:- Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch ‘A’ as supply only but fixing of the parts replaced/repaired is deemed to be included in this item.
All as per item No 23.00 but stabilizer of 75-160 KVA three phase.
All as per item No 23.00 but stabilizer of 2/3 KVA single phase.
All as per item No 23.00 but stabilizer of 0.5/1 KVA single phase.
Supply only the following new parts for 0.5 to3 KVA, Voltage Stabilizers (MAKE : Blue tech/Blue line/Blue bird/citizen ) : (NOTE : Fixing and testing element of these items is deemed to include under respective Schedule `A' item No 23.00 to 26.00 here-in-before)
Power transformer Input 140 – 280 volts & output 220 volts + 9% for 4/5 KVA
Power transformer Input 140 – 280 volts & output 220 volts + 9% for 2/3 KVA
Power transformer Input 140 – 280 volts & output 220 volts + 9% for 0.5/1 KVA
Relay 24 volts, single change over, 50 Amps. (MAKE : OEN / Dunmag / Eagle man)
Relay 24 volts, single change over, 30 Amps. (MAKE : OEN/ Dunmag / Eagle man)
Relay 24 volts, single change over, 05 Amps. ( MAKE : OEN/ Dunmag / Eagle man)
Auxiliary transformer 12/24 Volts
Wiring loop of suitable size copper wire
Volt meter 0-500 Volts 50mm Square type. Make : Enerco/AE/Rishab
Switch SPDT 220 Volts 1 Amp.
Indicator lamp Green/Red - 220 Volts
Toggle switch 15 Amps 2 Way 220 Volts.
PCB GB-28 AB
PCB – GB 4C
PCB – GB 26 AB
Supply and fixing outer body of suitable size and gauge of the following size voltage stabilizers Make : Blue line / Blue tech / Citizen
(a) 2/3 KVA voltage stabilizers
(b) 0.5/1 KVA voltage stabilizers
Disconnecting old unserviceable cable and supply, fixing and connecting 3 Core copper cable PVC insulated PVC sheathed round cable 1100 Volts of size 2.50 Sqmm conforming to IS-694 complete all as specified and directed.
Disconnecting old unserviceable cable and supply, fixing and connecting 3 Core copper cable PVC insulated PVC sheathed round cable 1100 Volts of size 1.50 Sqmm conforming to IS-694 complete all as specified and directed.
Disconnecting old unserviceable cable and supply, fixing and connecting 3 Core copper cable PVC insulated PVC sheathed round cable 1100 Volts of size 1.00 Sqmm conforming to IS-694 complete all as specified and directed.
M&L for Preparing old painted steel and metal based surfaces of any shape, size and description, removing oil, dust & rust by using sand paper or any method on all types of surfaces, filling cavities if any and applying one coat spray painting with synthetic enameled paint of approved quality (All as per E-in-C’s colour code) with and including writing E/M & MES Nos, Neatly on each machine complete
S&F variac motor suitable for 75-250 KVA voltage stabiliser with and including control electrical wiring with suitable size of copper cable or as directed by the EIC
M&L for Cutting and taking out old/burnt winding from the transformer limb of75-KVA to 250 KVA HP cleaning of core and housing with CTC solution and rewinding thetransfor of the voltage stabiliser with super enamelled heavy duty winding wire existing guage and existing Nos of turn with and including insulation material insulation paper, varnish and baking up till the complete insulating dried. all as as specified and directed.
S&F dimmer suitable for 75-250 KVA voltage stabiliser complete with and including making connetion with main transformer and Auxillary transformer to stabilised voltage all as specified and directed
Uma engineers
Ganga Enterprises
M/s Yashika Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .