Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.6 L+₹25,490 (1.66%)Rejected-AOC HYDERABAD TELANGANA 500076 INDIA UDYAM TS 02 0009467 | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹17.1 L+₹1.8 L (11.7%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-AOC Other than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
3 Nov 2020, 6:00 pmClosed
CWE(AF) Chandigarh
HQ CWE(AF) Chandigarh PIN 160 003
REPAIR TO WATER SUPPLY LINE, ELECTRIC CABLE, AC, DG SET AND COOLING APPLIANCES ETC AT AIR FORCE STATION BARWALA UNDER GE (AF) CHANDIGARH
2020_MES_383004_1
CWE/AF CHD/CHD/T-35/2020-2021
Open Tender
Civil Works
Item Rate
275 days
Barwala
As per NIT
8 documents required · 8 mandatory
₹500
GE(AF) Chandigarh
₹40,000
Yes
2 Dec 2020
3 Oct 2020
5 Nov 2020
3 Oct 2020
3 Nov 2020
21 Oct 2020
Amount
EXTERNAL ELECTRIFICATION
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Material and labour, locally available, sub class `B’ bricks (old size), laid flat and dry perpendicular to the direction of cable adjacent to each other, in trenches over the cable for protection, complete all as specified and directed.
All as per serial item No. 1.05 here-in-before but using old retrieved bricks
Taking out / down old existing LT 1100volt grade cables, size 10Sqmm, aluminium conductor 2core, XLPE/ PLCA/ PVC, armoured, laid in trenches, including bricks for protection, sand cushioning and stacking, removal to store for re-use or for credit, complete all as specified and directed Note : Excavation shall be measured and paid for separately
All as per Serial Item No. 1.07 here-in-before but 16Sqmm 2.0Core size
All as per Serial Item No. 1.07 here-in-before but 16Sqmm 4Core size
All as per Serial Item No. 1.07 here-in-before but 25Sqmm 3.5Core size
All as per Serial Item No. 1.07 here-in-before but 35Sqmm 3.5Core size
All as per Serial Item No. 1.07 here-in-before but 50Sqmm 3.5Core size
All as per Serial Item No. 1.07 here-in-before but 70Sqmm 3.5Core size
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 10Sqmm 2 core aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: Returning filling & removal of earth, sand cushioning and bricks for protection of cable shall be measured and paid separately.
All as per Serial Item No. 1.14 here-in-before but 16Sqmm 2Core size
All as per Serial Item No. 1.14 here-in-before but 16Sqmm 4Core size
All as per Serial Item No. 1.14 here-in-before but 25Sqmm 3.5Core size
All as per Serial Item No. 1.14 here-in-before but 35Sqmm 3.5Core size
All as per Serial Item No. 1.14 here-in-before but 50Sqmm 3.5Core size
All as per Serial Item No. 1.14 here-in-before but 70Sqmm 3.5Core size
Supply, jointing & testing, indoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armoured aluminium conductor cable, 3core, 95Sqmm size cable, complete all as specified and directed.
Supply, jointing & testing, outdoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armored aluminium conductor cable, 3core, 95Sqmm size cable, complete all as specified and directed.
Supply, jointing & testing, straight through joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armoured aluminium conductor, 3core, 95Sqmm size cable, complete all as specified and directed.
Supply and laying / fixing , GI pipe light grade 100mm dia bore for cable protection fixed to pole/wall or laid under floor/road/pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified and directed. Note: Boring of holes under road etc. shall be measured and paid separately.
All as per Serial Item No. 1.24 here-in-before but 80mm dia bore.
All as per Serial Item No. 1.24 here-in-before but 50mm dia bore.
Material and labour for switch air break, gang operated triple pole ,mechanically operated, mounted on 12 insulators including drop out insulators including 3 nos barrel type drop out fuses and steel frame with operating mechanism worked from ground level with 25mm medium grade GI tubing for current rating upto 400 amps,11000 volt including taking down old and removal complete all as specified and directed.
Material and labour for lightening arrestor high tension, expulsion type complete with all fittings, transmission class ,discharge capacity 65 kilo amp, suitable for 11000 volt grade system fixed in position including disconnecting and taking down old and removal, complete all as specified and directed.
Supply and filling of transformer oil superior quality having di-electric strength not less than 40 KV at 4.0mm gap, ISI marked, 200 litre sealed drum, and filling into transformers and other equipments installed at various locations, after taking out old unserviceable oil, complete all as specified and directed.
Supply and fixing in replacement under mentioned spare/parts of transformer capacity from 50KVA to 200KVA, complete all as specified and directed.
Air breather assembly with silica gel
HT side procelain bush 11 KV (Set of 03) with brass studs, nuts & washers, rubber gasket etc
LT side procelain bush 415Vupto 100 KVA transformer (Set of 04) with brass studs, nuts & washers, rubber gasket etc
LT side procelain bush 415V upto 200 KVA transformer (Set of 04) with brass studs, nuts & washers, rubber gasket etc
Strip opening and repair, maintenance & overhauling of HT (11 KV) VCB of make Kirloskar/ Crompton of capacity upto 400Amps, indoor type complete after taking out trolley, checking of all fixed and moving parts for smooth operations, cleaning with CTC or CRC 226 and rustlick, air blower, replacement of parts, checking and repair to locking system, alignment & closing / triping & charging system, repair to heaters with switch and thermostat and making the complete VCB (of make Kirloskar/Crompton) functional with free and operating mechanism, complete all as specified and directed. Note: (i) Repair/ maintenance/ servicing/ replacement of VCB parts will be carried out by the authorized rep of the company. (ii) Defective/worn out parts (other than minor) shall be measured and paid for separately as 'supply and fix'. (iii) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning & greasing etc. is included in the quoted rates.
Supply and fixing in replacement under mentioned spare/parts 11 KV, 400 Amps HT VCB, any model/type of make: Kirloskar/Crompton complete all as specified and directed.
Supply only, Potential Transformer (PT) of 11 KV/110V, totally enclosed, sealed and stmped, epxoy filled, heavy duty, suitable for 11 KV 400 Amps HT VCB, complete all as specified and directed.
Supply only, Micro process based relay heavy duty, suitable for 11 KV 400 Amps HT VCB, complete all as specified and directed.
Supply and fix, vaccum interruptor for VCB, complete all as specified and directed.
Supply and fix, trolly insulator for mounting vaccum interruptor for VCB, complete all as specified and directed.
Supply and fix, epoxy fibre base plate for interruptor, complete all as specified and directed.
Supply and fix, epoxy insulator for bus bar supports, complete all as specified and directed.
Supply and fix, finger moving contact (Made up of six, each male and female, fingers), spring loaded, heavy duty, suitable for 11KV, 400Amp, HT VCB, complete all as specified and directed.
Supply & fix, Current Transformer (CTs) of CTR 50-25 / 5Amps, totally enclosed, sealed and stamped, epxoy filled, heavy duty, suitable for 11 KV 400 Amps HT VCB, complete all as specified and directed.
Supply and fix, MCCB, 400Amps, 4pole, 415Volts, 50Hz, 35KA, with fixed thermal and magnetic setting, including taking down old and removal, complete all as specified and directed.
All as per Serial Item No. 1.45 here-in-before but 250Amps
All as per Serial Item No. 1.45 here-in-before but 200Amps
All as per Serial Item No. 1.45 here-in-before but 160Amps, 25KA
All as per Serial Item No. 1.45 here-in-before but 3 pole, 250Amps & 35KA
All as per Serial Item No. 1.45 here-in-before but 3 pole, 200Amps & 25KA
All as per Serial Item No. 1.45 here-in-before but 3 pole, 160Amps & 25KA
All as per Serial Item No. 1.45 here-in-before but 3 pole, 125Amps & 25KA
All as per Serial Item No. 1.45 here-in-before but 3 pole, 63Amps & 16KA
Material and labour for painting two coats of aluminium paint to old painted surfaces steel tubular poles 9/11 meter long any description (external surface only) including MS cross arms etc and including painting 6 strips of height 0.3 mtr each (three nos sky blue & three nos white), writing pole no with black paint with letters /figures 7.5cm high including preparation of old painted surface complete all as specified and directed by Engineer-in-charge.
Material and labour for painting two coats of cement base paint to old painted surfaces PCC poles 9 meter long any description (external surface only) and including painting 6 strips of height 0.3 mtr with synthetic enamel paint each (three nos sky blue & three nos white), writing pole no with black paint with letters /figures 7.5cm high including preparing of old painted surface complete all as specified and directed by Engineer-in-charge
Material and labour for preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint to LT feeder pillar box, complete all as specified and directed.
Supply, jointing & testing, straight through joint kit complete with jointing material and accessories suitable for 3wire 1.1KV grade, LT, underground XLPE insulated armoured aluminium conductor, 3.5core 25Sqmm to 50 Sqmm size cable, complete all as specified and directed.
All as per Serial Item No. 1.57 here-in-before but size 3.5 core, 70 Sqmm to 95 Sqmm.
Supply and fixing in replacement, factory made indoor type bus bar chamber box , wall mounted type made out of 2mm thick CRCA sheet powder coated single door of size 60cmx60cmx30cm having insulated copper bus bar of capacity 200Amps three phase, installed on porcelain insulator, complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of factory made tested (Including CPRI type tested certificate) LT panel board cubical outdoor type of size 0.90 x 0.60 x 0.30 mtrs, suitable for, 415 volts 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bar of rating 200 Amp installed on porcelain/SMC insulator. The panel shall be dust and vermin proof IP-65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apron for cable entry, closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked, 1100 volts grade of appropriate size (but not less than 4.0 sqmm) and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size etc, complete all as specified and directed.
Supply and fix in replacement, on load change over switch 04 pole, 200A, complete all as specified and directed by Engineer-in-charge
Supply and fix in replacement, power pack 220V AC/24VD suitable for 11KV 400Amp HT VCB, complete all as specified and directed by Engineer-in-charge
Finding/locate fault in HT 11KV grade cable of any size and depth, within 1.0Km length or more with the help of cable fault locator instrument of latest design, cable laid in trenches, floor or pipe and rectification the same, complete all as specified and directed.
All as per item No. 1.63 here-in-before but in LT 1100 Volts grade cable, complete all as specified and directed. Note for serial Item No. 1.63 & 1.64 (i) The fault shall be rectified within 6hrs from receiving complaint telephonically/SMS by JE or AGE E/M , if the fault is not rectified within 6hrs, the penalty of Rs. 5000.00 per hour shall be recovered from the contractor. (ii) The number of fault occurred within 1KM length in same location shall be treated as one fault.
Material and labour, earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32mmx6mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete including dismantling of existing earthing all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
Material and labour, earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron wire of 4 mm dia (8SWG) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 15mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete including dismantling of existing earthing all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
Material and labour for earthing kit, developed on concentric pipe technology concept with mild steel tubes one inside the other, hot dip galvanized and filled with high conductive and crystalline conductive mixture backfill compound put arround the electrode retains moisture as an excellent ground enhancer, earthing electrode 80mm with 3meter long pure copper pipe with 50Kg of backfill chemical earthing as per IS-3043 including dismantling of existing, complete all as specified and directed.
Material and labour for GI strip 32x6mm as in earth continuity conductor including dismantling of existing, complete all as specified and directed.
Material and labour for copper strip 20x3.15mm as in earth continuity conductor including dismantling of existing, complete all as specified and directed.
Material and labour for test point made out of copper strips 32x6mm, 200mm long - 02 Nos and 12mm dia brass nuts bolts 40mm long - 03 Nos including dismantling of existing, complete all as specified and directed.
Material and labour for test point made out of GI strips 50x6mm, 200mm long - 02 Nos and 12mm dia GI nuts bolts 40mm long - 03 Nos including dismantling of existing, complete all as specified and directed.
DG SET REPAIRS
Maintenance of DG set of any make, type, model as per set norms of the original manufacturer set and by the authorised rep of the company after unscrewing nut, bolts, screws etc. for servicing, maintenance, tightening, adjustment & cleaning of all moving and stationary parts of DG set, complete and segregating the parts for repair/ refixing/ replacing of capacity 30KVA make kirloskar complete all as specified and directed, installed at WT, admin power house Note: The quoted rate includes the following: (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning & greasing etc. of DG set parts. (c) Defective major parts/ engine oil to be replaced will be measured & paid separately as "supply and fix".
Supply and fix, primary filter element only suitable for above DG set, complete all as specified and directed.
Supply and fix, Secondary filter element only suitable for above DG set, complete all as specified and directed.
Supply and fix, air filter element only suitable for above DG set, complete all as specified and directed.
Supply and fix, oil filter element complete all as specified and directed by Engineer-in-charge.
Supply and fix, fuel and oil hose pipe set suitable for above DG set, complete all as specified and directed.
All as per Serial Item No. 2.01 here-in-before but of cpacity 40 KVA make Kirloskar installed at AFNET and PUMP HOUSE No. 3.
Supply and fix, primary filter element only suitable for above DG set, complete all as specified and directed.
Supply and fix, Secondary filter element only suitable for above DG set, complete all as specified and directed.
Supply and fix, air filter element only suitable for above DG set, complete all as specified and directed.
Supply and fix, oil filter element only suitable for above DG set, complete all as specified and directed.
Supply and fix, water hose pipe set suitable for above DG set, complete all as specified and directed.
Supply and fix, fuel and oil hose pipe set, complete all as specified and directed.
All as per Serial Item No. 2.01 here-in-before but of capacity 63KVA make kirloskar installed at Admin power house
Supply and fix, primary filter element only suitable for above DG set, complete all as specified and directed.
Supply and fix, Secondary filter element only suitable for above DG set, complete all as specified and directed.
Supply and fix, air filter element only suitable for above DG set, complete all as specified and directed.
Supply and fix, oil filter element complete all as specified and directed by Engineer-in-charge.
Supply and fix, fuel and oil hose pipe set suitable for above DG set, complete all as specified and directed.
Material and labour, taking out radiator and repairing/ brazing/ cleaning and refixing the radiator including testing for DG set capacity 10KVA to 40KVA, complete all as specified and directed.
Supply & filling, Lubricant oil (Engine oil) SAE30 (Make: As recommended by the manufacuturer of DG set and as approved), complete all as specified and directed.
Supply, install, connecting and testing in replacement maintenance free batteries, 12 Volts, 180AH, complete all as specified and as directed.
Supply, install, connecting and testing in replacement maintenance free batteries, 12 Volts, 130AH, complete all as specified and as directed.
Supply and fix, battery lead made out of 50 sqmm copper cable with terminal of brass with marking (+)/(-) & fixed in position & testing, including taking down and removal, complete all as specified and as directed.
Supply and filling, Engine coolant in radiators of DG sets as per DG set Manufacturer's recommendations at different locations, brought at site in sealed packets, in replacement, complete all as specified and directed.
Maintenance, repair, servicing of automatic mains failure panel 24Volt DC and 440Volt AC supply operated system by locating faults and replacement of userviceable parts and components, for DG set 30KVA to 40KVA, complete all as specified and directed, as per following:- Make of DG sets :- Kirloskar/Crompton Greaves/Ruston/Ashok Leyland Note:- The quoted rate includes the following:- (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screw, gasket, nuts, bolts, washers, cleaning and greasing etc of DG set parts. (c) Defective parts/engine oil to be replaced will be measured and paid seperately under supply only.
Repair of fault worn out control wiring DC/AC for engine starting and off, with adequated and suitable size copper conductor wire, connected with proper copper lugs & ternminals through protection pipe/casing, complete all as specified and directed.
Repair of worn out/faulty internal wiring of controls and timers, indicating/measuring instruments through various control fuses and relays with suitable and adequate size of copper conductor wire, connected with suitable copper lugs and terminals, complete all as specified and directed.
Repair of worn out small control fuses, indicating lamps, various type of copper lugs, thimbles terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable and perfectly in working order, complete all as specified and directed.
Material and labour for replacing unserviceable AVR of DG set for capacity 15KVA to 63KVA and testing, complete all as specified and directed.
Supply and fixing in repair, power contactor 3 pole, 200Amps, 415Volts opening coil, complete all as specified and directed.
Taking down the existing street light fittings any type i.e FTL/T5/T8/LED/SV/MV/MH/tube light carefully for repairs/replacing the defective parts and refixing the same in original position after carrying out necessary repair/replacement of parts, complete all as specified and directed.
PVC insulated stranded aluminium conductor, 1100 volts grade heavy duty cable of size 2.5 Sqmm 2 core (from junction box to street light fitting mounted on steel tubular/PCC pole) including taking down existing, complete all as specified and directed.
Supply and fixing in replacement, electronic driver suitable for LED street light/flood light of capacity upto 90W, complete all as specified and directed.
Supply and fixing in replacement, LED street light fitting 60W, comprising of single piece pressure die cast aluminium alloy housing powder coated , complete prewired fixed to pole/wall bracket and connected with flexible copper conductor cable of size 1 Sqmm three core suitable length, complete all as specified and directed. Make:- Crompton Cat Part No. LSTP-60-CDL or Equivalent in Appendix 'B'.
Supply and fixing in replacement, LED street light fitting 45W, comprising of single piece pressure die cast aluminium alloy housing powder coated , complete prewired fixed to pole/wall bracket and connected with flexible copper conductor cable of size 1 Sqmm three core suitable length, complete all as specified and directed.. Make:- Crompton Cat Part No. LSTP-45-CDL or Equivalent in Appendix 'B'.
Supply and fixing LED flood light luminare 150watt comprising of single piece pressure die cast aluminium alloy housing powder coated with clear acrylic bowl, complete prewired fixed to pole/wall bracket and connected with flexible copper conductor cable of size 1 Sqmm three core suitable length, including taking down old fitting, complete all as specified and directed. Make:- Crompton Cat Part No. LFLN-150-CDL/60 or Equivalent in Appendix 'B'.
Supply and fixing in replacement, LED post top latern 25W, comprising of single piece pressure die cast aluminium alloy housing powder coated , complete prewired fixed to pole/wall bracket and connected with flexible copper conductor cable of size 1 Sqmm three core suitable length, complete all as specified and directed.. Make:- Havells Cat Part No. CORALPT25WLED757PSYMTOPC or Equivalent in Appendix 'B'.
Supply and fix in repair, CPRI approved, indoor type, factory made junction box of size 300mmx200mmx150mm, dust, weather and vermin proof, IP-65 protection, fabricated out of 2mm thick MS CRCA sheet with aluminium bus bar strip 25mmx3mm - 04Nos and MCB SP 6Amp, 10KA- 01 No including painting with epoxy powder coated with anti corrosive paint including necessary MS clamps, nuts and bolts, washers etc for fixing and locking arrangements, complete all as specified and directed.
Supply and fix in repair, CPRI approved, indoor type, factory made junction box of size 300mmx200mmx150mm, dust, weather and vermin proof, IP-65 protection, fabricated out of 2mm thick MS CRCA sheet with aluminium bus bar strip 25mmx3mm- 02 Nos and MCB SP 6Amp, 10KA- 01 No including painting with epoxy powder coated with anti corrosive paint including necessary MS clamps, nuts and bolts, washers etc for fixing and locking arrangements, complete all as specified and directed.
Supply and fix in repair, LED bollard garden light fittings 8W, complete all as specified and directed. Make:- Havells Cat Part No. CONEBLS8WLED857PSYMTOPC (0.6M) or Equivalent in Appendix 'B'.
WATER SUPPLY AND SEWAGE INSTALLATIONS
Taking out defective submersible pump & motor set 6 to 8 stage, 700-900 LPM at 112mtr head of any dia upto 150mm from bore well with the help of chain pulley after disconnecting electrical connections from motor starter, disconnecting the column pipe from supply pipe line, opening each column pipe by unscrewing nut bolt, rubber packing of each column pipe, submersible cable and keeping a side for reuse the number of column pipe to be taken out upto 24-28 Nos. alongwith submersible cable, for repair / replacement of parts to make it fully functional, reassembling the same after repair, lowering/ installation to its original position, electric connection of input/ output electric supply, connecting the column pipe to supply pipe line testing to its full load capacity at least for 4 hours and all other relevant tests including any minor repair, replacement of rubber gasket for column pipe etc. transportation to workshop and vice-versa, complete all as specified and directed by the Engineer-in-Charge.
Dismantling of submersible motor 25 to 35 HP 415 volts 50 Hz 3 phase AC electric supply, taking out the burnt winding of stator, removal of burnt insulation material from the slots, cleaning the stator slots and preparation for rewinding the same and material and labour for winding the stator of motor with PVC insulated copper wire of standard size and superior quality copper winding wire as per the existing gauge including the F class insulation materials, turning, balancing & alignment of rotor etc. to get the proper RPM and torque & tested to its full load capacity complete all as specified and directed Note :- Spare parts required to be replaced shall be measured and paid separately as 'Supply only'.
Opening of pump set 6 to 8 stage, 700-900LPM at 112mtr head for repair and replacement of unserviceable parts, reassembling the same after repair, machining work of impeller housing, remetaling of pump shaft, grinding, scraping, cleaning and balancing the same to make it fully functional at the full load capacity including turning, balancing & alignment of shaft etc. reassembling of complete Pump & Motor set and testing on completion for the entire satisfaction of Engineer – in - Charge all as directed. Note:- Spare parts required to be replaced shall be measured and paid separately as 'Supply only'.
Supply only of motor housing rotor bush for 25 to 35 HP submersible motor complete all as specified and directed.
Supply only of water seal for 25 to 35 HP submersible motor complete all as specified and directed.
Supply only of thrust bearing set for 25 to 35 HP submersible pump complete all as specified and directed.
Supply only bush Gun metal for 700-900LPM submersible motor complete all as specified and directed.
Supply only impeller Gun metal for 700-900LPM submersible pump complete all as specified and directed.
Supply only impeller neckring for 700-900LPM submersible pump complete all as specified and directed.
Supply only impeller bush for 700-900LPM submersible pump complete all as specified and directed.
Supply only impeller locknut for 700-900LPM submersible pump complete all as specified and directed.
Supply only stainless steel shaft for 700-900LPM submersible pump complete all as specified and directed.
Supply only of Coupling set including key and MS nut bolt suitable for submersible pump sets, complete all as specified and directed.
Supply and fixing/laying in replacement cable submersible PVC insulated water proof with copper conductor cable 3x16Sqmm, 1100 volt grade after taking out old unserviceable cable confirming to IS complete all as specified and directed.
Taking out self priming non clog submersible pump set after removal of electrical connections, disconnecting suction/ delivery pipeline connection, from sewage well upto 6m depth and transportation to workshop for repair & vice versa. Refixing after carrying out repair /rewinding of submersible pump set electrically driven by 3phase 415volts capacity7.5HP complete all as specified and directed by Engineer-in-charge. NOTE:- Repair / spare parts shall be measured & paid for separately
Taking out the burnt winding of stator of submersible/squirrel cage/TFT motor, removal of burnt insulation material from the slots, cleaning the stator slots and preparation for rewinding the same. Material and labour for winding the stator of motor 5HP with PVC insulated copper wire of standard size and superior quality as per the existing turns & gauge including 'F' class insulation materials to get the proper RPM and torque. Turning, balancing & alignment of rotor etc. Complete all as specified and directed.
Supply only spares/parts suitable for Pump & motors complete all as specified and directed for the following :-
Terminal block of motor of capacity upto 5HP 415volts.
Bearing any type for motor of capacity upto 5HP 415volts.
Remettaling of motor & pump shaft including polishing and balancing.
Impeller including bush, lock nut etc. any type / capacity
Gland cup
Misc items i.e. stud, MS nut, bolts, keys etc..
Supply only sodium Hypo chlorite( NaOCL) chemical solution conforming to IS-1673/86 having chloride content 10 % by weight (bleach liquid solution) complete all as specified and directed by Engineer-in Charge. Note : Chemical solution shall be supplied by the contractor as on requirement basis through out the currency of the contract .Therefore the contractor shall procure the chemical solution in piecemeal as per requirement .The material shall be deposited with AGE E/M-1 (A/F) Barwala and RV shall be prepared accordingly. Contractor shall also arrange independent testing of chemical from Govt authorized laboratory at his own expense. The cost of testing shall be deemed to be included in the quoted rate. Payment of supply of Sodium chlorite solution shall only be made on production of test report.
Supply and fix in repair electronic metering dozing pump with following technical specification, complete all as specified and directed:- Model: TJ-MD 8 Capacity(lph) : 0 - 6 Back Pressure (kg/cm²) : 10 Drive : Solenoid Capacity adjustment:- 1. Adjustable stroke frequency between 0 to 100 strokes/min 2. Adustable stroke length between 0 to 100% MOC of wetter parts : PP MOC of diaphragm : PTFE coated EPDM Power (W) : 30 Power Supply : Single phase 230V, 50 Hz Accessories: Foot Valve, Injection Fitting and 3 mtrs Hose pipe Make : Toshcon Jesco or equivalent in Appx 'B'
Taking out/down old GI pipe 20mm bore with fittings, laid in trenches, under floor stacking serviceable and removal of unserviceable pipe, complete all as specified and directed by Engineer-in-charge. Note: Excavation & earthwork shall be measured and paid separately.
All as per item No 3.26 but GI pipe 25mm bore complete all as specified and directed by Engineer-in-charge.
All as per item No 3.26 but GI pipe 40mm bore complete all as specified and directed by Engineer-in-charge.
All as per item No 3.26 but GI pipe 50mm bore complete all as specified and directed by Engineer-in-charge.
Supply and laying GI pipe medium grade 20mm dia with all fittings laid in trenches/fixed along with walls or laid under floors, complete all as specified and directed. Note :- Excavation & earthwork shall be measured and paid separately.
All as per item No 3.30 but GI pipe 25mm bore, complete all as specified and directed .
All as per item No 3.30 but GI pipe 40mm bore, complete all as specified and directed .
All as per item No 3.30 but GI pipe 50mm bore, complete all as specified and directed .
Supply and fix, Gun Metal gate valve with iron wheel head, screwed both ends for 20mm dia bore pipe, including taking down old and removal, complete all as specified and directed.
All as per item No 3.34 but Gun metal gate valve 25mm bore complete all as specified and directed .
All as per item No 3.34 but Gun metal gate valve 40mm bore complete all as specified and directed .
All as per item No 3.34 but Gun metal gate valve 50mm bore complete all as specified and directed .
Supply and fix, cast iron sluice valve for 100mm dia bore pipe, with flanged and drilled ends, any pattern, heavy duty, class PN 1.6, ISI marked & of specified make, Cast iron wheel, including joints and jointing materials as rubber washers/gaskets, bolts and nuts, etc, also taking down old and removal, complete all as specified and directed.
All as per item No 3.38 but 150mm bore complete all as specified and directed by Engineer-in-charge.
All as per item No 3.38 but 200mm bore complete all as specified and directed by Engineer-in-charge.
Material and labour, run lead joint for 100mm dia bore CI pipe and fittings, complete all as specified and directed.
Material and labour, run lead joint for 150mm dia bore CI pipe and fittings, complete all as specified and directed.
Material and labour, run lead joint for 200mm dia bore CI pipe and fittings, complete all as specified and directed.
Draining out water completely from RCC over head Reservoir of capacity 50000 gallons in two parts at 50 feet staging and material and labour for desludging of RCC over head reservoir manually ,cleaning the inner portion of RCC tank by brooming with fine brush ,removing complete silt,sludge,vegetations unwanted foreign materials etc manually under artificial pressure from the tank, filling of cracks with pidilite /Dr fixit non shrink compound suitable to potable water to make tank leak proof. Plastering in CM 1:4, 15mm thick to the internal & external surfaces of the damaged portions of the reservoir and staging and applying two coats of cement base paint to the external surface of the reservoir and staging. Painting with black synthetic enamel paint to the all CI pipe line and other MS work etc fitted with the RCC OH reservoir and staging including making a block in Synthetic enamel paint 1mtr in height black base and writing in 50mmx50mm size letters with white synthetic enamel paint, DATE OF TANK CLEANING complete all as specified and as directed.
Excavation & earth work in any type soil for locating the leakage in existing cast iron water mains any type/size 100mm bore (including all fittings) and rectifying the leakage complete all as specified and directed and refilling and compacting the soil. Note: Any CI fittings/specials, joint & jointing material etc required for the rectification of leakage shall be measured & paid for separately.
All as per Serial Item No 3.45 here-in-before but CI pipe of 150mm bore complete all as specified and directed.
Excavation & earth work in any type soil for locating the leakage in existing GI water mains any type/size upto 25mm bore (including all fittings) and rectifying the leakage complete all as specified and directed and refilling and compacting the soil. Note: Any GI fittings/specials, joint & jointing material etc required for the rectification of leakage shall be measured & paid for separately.
All as per Serial Item No 3.47 here-in-before but GI pipe up to 40/50mm bore complete all as specified and directed.
Collection of the water sample from the borewell duly sealed by the Engineer-in-Charge, carrying to the PHE UT Chandigarh/Govt lab for testing, depositing it and collecting the test report from the lab & deposited with the department, complete all as specified and directed.
Supply and fix fully automatic star-Delta Starter suitable for 30 HP submersible motor 415 volts 50 HZ AC including over load relay, range and power contactor, single phase preventer with volt meter and ammeter and MCB TP etc complete all accessories pre-wired/connected with suitable size copper conductor, complete all as specified and directed.
Supply onnly DOL starter in sheet steel enclosure suitable for 5 HP monoblock centrifugal pump set 415 volt 50 Hz complete inlcuding power contactor, over load relay range 7 to 10 Amp, single phase preventer, pre-wired, complete all as specified and directed.
AIR CONDITIONING
Material and labour for servicing to Split type AC operated on 240 volts single phase AC electric supply of any make/type capacity 1.5/2.0 Ton, both internal / external units of AC, dry cleaning with blower / vacuum cleaner, washing with soap solution and cleaning with water pressure through jet, make it fully serviceable , complete all as specified and as directed by Engineer-in-Charge.
All as per item No 4.01 here - in- before but for window type AC unit of any make /model and capacity, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing sealed unit Hermatic Compressor operated on "R-22 refrigerant" Company replaced only suitable for split/window type AC 1.5 Ton capacity of existing make and model duly filled of gas, compressor oil including taking out old/US compressor complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing sealed unit Rotary Compressor operated on "R-22 refrigerant" Company replaced only suitable for split / window type AC 1.5 Ton capacity of existing make and model duly filled of gas, compressor oil including taking out old US compressor complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing the following spares/parts for split /window type AC unit including taking out old /US spares/parts complete all as specified and as directed.
Copper tube 5/8 inch bore including necessary insulation.
Copper tube 3/8 inch bore including necessary insulation.
Blade only for blower outdoor motor split unit any type.
Blade only for blower indoor motor split unit any type.
Blade only for blower window type unit any type.
Starting relay Make:Renutral/Indfoss/Denfoss
Over Load Protector Make:Renutral/Indfoss/Denfoss
Thermostat switch Make:Renutral/Indfoss/Denfoss
Starting Capacitor 100-120MFD any capacity Make:Epcos/Usha/Tesla
Running Capacitor 36MFD any capacity Make:Epcos/Usha/Tesla
Blower motor for outdoor unit. Make:AUE/Cool Home/Universal
Blower motor for indoor unit. Make:AUE/Cool Home/Universal
Blower motor double shaft for Window AC unit. Make:AUE/Cool Home/Universal
Liquid line strainer
Capacitor 4MFD 230Volts. Make:Epcos/Usha/Tesla
Material and labour for Internal wiring for split unit of any capacity with single core copper conductor FRLS cable as per existing size only complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Internal wiring for window unit of any capacity with single core copper conductor FRLS cable as per existing size only complete all as specified and as directed by Engineer-in-Charge.
Supply & filling/charging of gas refrigerant R-22 to split type AC 1.5 Ton capacity of any make and model including detection of gas leakage, brazing and welding etc., restore the gas pressure and creating vacuum complete all as specified and as directed by Engineer-in-Charge.
All as per item No 4.23 here in - before but for Window type AC 1.5 Ton cap complete all as specified and as directed
Removal for servicing to Water cooler operated on 240 volts single phase AC electric supply of any make/type 40/80Ltrs or 150Ltrs capacity, dry cleaning with blower / vacuum cleaner, washing with soap solution, under clean water pressure through jet, make it fully serviceable Cleaning of water storage tank, detection of water leakage, brazing / welding to restore the leakage and vice-versa, complete all as specified and as directed by Engineer-in-Charge. Note:- If any minor part/spare is required replacement at site, or any addition / alteration required deemed to be included in quoted unit rate and nothing extra shall be admissible on this account.
Supply and fixing sealed unit Hermatic Compressor Company replaced only suitable for Water Cooler 40/80Ltrs capacity of existing make and model duly filled of gas, compressor oil including taking out old/US compressor complete all as specified and as directed by Engineer-in-Charge.Make:Kirloskar
All as per item No 4.26 here in - before but for Water Cooler 150Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.Make:Kirloskar
Supply and filling/charging of gas refrigerant R-22 for Water Cooler 40/80Ltrs capacity of any make and model including detection of gas leakage, brazing and welding etc., restore the gas pressure and creating vacuum complete all as specified and as directed by Engineer-in-Charge.
All as per item No 4.25 here in - before but for Water Cooler 150Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement the following items of existing make and model suitable for refrigerator 165/320 capacity including taking out old /US spares / parts complete all as specified and as directed by Engineer-in-Charge.
Steel Shelves PVC coated 165 -180Ltrs. capacity
Starting Relay Box 165 - 180Ltrs. capacity. Make:Renutral/Indfoss/Denfoss
Overload Protection Box 165 - 180Ltrs. capacity. Make:Renutral/Indfoss/Denfoss
Running Capacitor 10MFD 230volts.
Thermostat switch any capacity.
Vegetable Tray with glass cover165 - 180Ltrs. capacity.
Rubber door gasket magnetic type 165 - 180Ltrs. capacity.
Crisper tray 165 - 180Ltrs. capacity. .
Pigmy lamp 10watts 230 volts.
Ice Tray PVC
Capillary tubes copper 1/60"
Liquid line stainer
Internal wiring of refrigerator of any capacity
Supply and fixing for in replacement the following items of existing make and model as that of existing items for water cooler any capacity including taking out old /US spares/parts complete all as specified and as directed by Engineer-in-Charge.
Over Load Protector 40/80 Ltrs capacity.Make:Renutral/Indfoss/Denfoss
Liquid line stainer any Capacity.
Blade only for condensor motor any capacity
Starting relay Kit 40/80 Ltrs capacity.Make:Renutral/Indfoss/Denfoss
Thermostat switch any capacity.Make:Renutral/Indfoss/Denfoss
Starting Capacitor 40-60MFD 230Volts.Make:Epcos/Usha/Tesla
Running Capacitor 20MFD 230Volts.Make:Epcos/Usha/Tesla
Condensor motor only
Push Cock CP 15mm.
Magnetic Rubber gasket for top cover any capacity.
PVC Drain pipe 32mm bore not less than 1mtr in length.
Internal wiring of refrigerator/deep freezer/water cooler etc of any capacity
Taking down carefully the following accessories /parts from existing desert cooler and providing new accessories /parts in desert cooler details as given in below complete all as specified and as directed by Engineer-in-Charge:-
Fan motor 350Watts 230Volts 3Speed copper winding single phase complete. Make: KHAITAN/Crompton/Universal
Submersible type Tulu pump 230Volts single phase 1750LPH at 1.5 mtr head complete Make : KHAITAN/Crompton/Universal
Fan blade only
Switch piano type 5 Amp , single pole 230 volts.
Front grill of M S /PVC complete with slides operation and indicator lamps.
Wood wool pad set of three of best quality including fixed wth bamboo stick any size.
PVC pipe heavy duty 15mm bore ISI Marked.
PVC Distribution Tee, Elbows and other minor items (heavy duty) 15mm bore ISI Marked.E101
Internal wiring of desert cooler of any capacity
Material and labour for providing in replacement MS sheet 20 SWG for tank of desert cooler capacity 60ltr, complete all as specified and as directed by Engineer-in-Charge. Note : The cost of welding/revieting, finishing, primer (Red Oxide) two coats of spray painting with synthetic enamel paint, inner portion of bottom and sides painted with black Japan bituminous paint shall also be deemed to included under the unit rate of item.
Taking down desert cooler of any make/capacity carefully and scraping old paint completely and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer after filling the cavities of MS Sheet with filler (outer surface) and 2 coats of black Japan paint complete (bottom and sides) all as specified and as directed by Engineer-in-Charge. Note : Taking down and re-fixing in the same position after painting work shall be deemed to include in the unit rate of this item.
Taking down to split type AC operated on 240 volts single phase AC electric supply of any make/type capacity 1.5/2.0 ton, both internal/external unit of AC, dry cleaning with blower/vacuum cleaner, washing with soap solution and cleaning with water pressure through jet, make it fully serviceable. Transportation to the other location, fixing including necessary hold fast etc and testing, complete all as specified and as directed by Engineer-in-Charge. Note : Any material required to make it fully functional shall be measured and paid separately.
All as per above item No 4.70 here-in-before but AC window type capacity 1.5/2.0 ton, complete all as specified and as directed by Engineer-in-Charge.
Note: The Total amount shall subject to adjustment of credit of Rs. 85926.00 for old Materials as per Schedule of Credit.
POWER TECH ENGINEERS
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .