| 1 | L1₹5.6 LAccepted-AOC | L1 | Accepted-AOC Work awarded due to L1 | |
| 2 | L3₹5.8 L+₹18,041 (3.24%)Rejected-AOC | L3 | Rejected-AOC Work not awarded due to not a L1 | |
| 3 | L3₹5.8 L+₹20,501 (3.68%)Rejected-AOC | L3 | Rejected-AOC Work not awarded due to not a L1 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹6.3 L
EMD Value
₹13,000
Closing Date
21 Jun 2022, 3:00 pmClosed
Director CSIR-AMPRI,Bhopal
Near Habibganj Naka, hoshangabad Road
Electrical Wiring
2022_CSIR_119003_1
1(483)2021 Works
Open Tender
Electrical Works
Item Rate
30 days
CSIR-AMPRI
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Director CSIR- AMPRI
₹13,000
Yes
3 Aug 2022
14 Jun 2022
22 Jun 2022
14 Jun 2022
21 Jun 2022
15 Jun 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box/celling rose and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group 'C'.
Wiring for circuit / submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required
a) 2 X 1.5 Sq.mm + 1 X 1.5 Sq.mm earth wire.
b) 2 X 2.5 Sq.mm + 1 X 2.5 Sq.mm earth wire.
c) 2 X 4 Sq.mm + 1 X 4 Sq.mm earth wire.
d) 2 X 6 Sq.mm + 1 X 6 Sq.mm earth wire..
Supplying and Drawing following 2 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor telephone cable in the existing surface/rrecess/steel/PVC conduit as required
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (Make - BEC/Kissan/Kasta/ Supreme/ Sudhakar/ Reliance)
Supplying and fixing follwing modular Switch/Socket on the exixting modular plate & switch box including connections excluding moddular plate etc as required.
5/6amps switch
3 pin 5/6 Amps Socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Telephone Socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including,connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplyiong and Fixing following size/ Modular plate, GI box alongwith modular base & cover plate for modular switchesin recess ets as required
(a) 1/2 module
(b) 6 module
(C) 8 module
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and Drawing of UTP 4 pair CAT 6 Cable in the executing surface recssed /Steel/PVC conduit,as required
1 run of Cable
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
Supplying and fixing 5 amps to 32 amps rating, 240 volts 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) Single Pole
b) Single Pole and Neutral
c) Triple pole
Supplying and fixing following rating, four pole, 415 V, isolatorin the existing MCB Disgtribution board complete with connections, testing andcommissioning etc. as required
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required
63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying,installation,testing and commissioning of prewired LED compact light fitting of following type complete with all accessories etc. recess/surface/panel/flase ceiling i/c connection with 3 x 1.5 sq. mm FRLS PVC insulated copper conductor wire earthing etc. as reqd.
a)supplying and fixing of LED surface mounted downlight 15/18 watt with Lamp complete with connection and testing etc as required as per Havells modal no.GLOWGENXDLS18WLED857S or similar make like havells/ Crompton/philips/wipro)
Supplying Installation testing and commissioning of min 200mm , 1350 rpm PVC exhaust fan including louver/ shuter as front cover in the existing opening, including making good the damage, connection with 3 x 1.5 Sq. mm copper conductor i/c testing, commissioning etc. as required. (Make:Crompton/Orient/Havells/usha )
Supplying and fixing of RJ-45 Computer socket outlet modular type with GIO box and modular plate i/c making connection etc. as reqd.
Supplying & laying at site XLPE Insulated PVC Sheathed steel Armoured under ground Electric cable with aluminium conductor for working voltage upto and including 1100 Volts to IS:7098 (Part-1) or IS:1554 (Part-I) with latest amendment as applicable of size 4 x 16 sqmm (make :Finolex /CCI/Polycab/ RR kable)
Supplying & laying at site XLPE Insulated PVC Sheathed steel Armoured under ground Electric cable with aluminium conductor for working voltage upto and including 1100 Volts to IS:7098 (Part-1) or IS:1554 (Part-I) with latest amendment as applicable of size 3 1/2 x 35 sqmm (make :Finolex /CCI/Polycab/ RR kable)
Supplying and fixing High Speed Grga Bit 16 pot switch on recess/ surface of the wall etc as complete make ( D-link,legrand,Cisco, digilink)
Supplying and fixing 20 pair MDF Box with krone module and subscriber terminal , Compatible with LSA IDC module and subscriber terminal block,3 0-pair distribution box for indoor, screw / key locking type in surface and recess etc as required
Supplying installation testing & commissioning of 80-100 watt integral LED flood light fitting with driver inside a PDC Housing, highly efficient, reliable with Driver & all accessories i/c connection complete etc. as required.
SITC of invertor type split Air Conditioing, minimum 3 star Rating , rotary type campressure , 2 ton capacity , 100 % copper ,input voltage 230 volt, Eco Friendly gas swith outdoor stand and complete installataion, with fixing of celling with anchor fasner bolts, laying of copper wire etc as required (Carrier/Hithachi/blue star/Daikin)
MAHESH POWER CONTROL INSTRUMENT SYSTEM
WOOD DECORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .