| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 CrAdmitted-Finance | ₹22.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹22.4 CrAdmitted-Finance | ₹22.4 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Does not fulfill the NIT Criteria of Similar works |
| Sl No | Description | Qty | Unit | Anurag Enterprises L1 | JYOTI SARUP MITTAL L2 |
|---|---|---|---|---|---|
| 0.00General Abstract of Cost | |||||
| 1.00 | PART I : CIVIL WORKS | 1 | Nos | 5,51,37,253 ₹5.5 Cr | 5,98,90,470 ₹6.0 Cr |
| 2.00 | PART I I : INTERNAL PH WORKS | 1 | Nos | 10,96,450 ₹11.0 L | 10,26,700 ₹10.3 L |
| 3.00 | PART III : ELECTRICAL WORKS | 1 | Nos | 1,03,47,721.15 ₹1.0 Cr | 71,34,910 ₹71.3 L |
| 4.00 | PART IV : HVAC WORKS | 1 | Nos | 45,13,845.8 ₹45.1 L | 40,71,250 ₹40.7 L |
| 5.00 | PART V : FIRE FIGHTING WORKS | 1 | Nos | 26,56,193.7 ₹26.6 L | 25,66,640 ₹25.7 L |
Tender Value
₹8.8 Cr
EMD Value
₹17.6 L
Closing Date
9 Jan 2023, 5:00 pmClosed
Chief Engineer C1
Chief Engineer (C1), DCSEM, DAE, 3rd floor, V.S. Bhavan, Anushaktinagar, Mumbai-94
Construction of Warehouse and Maintenance Office Building in Campus for Global Centre for Nuclear Energy Partnership (GCNEP) including Civil, PH, Electrical, HVAC, Firefighting etc at Jassaur Kheri near Bahadurgarh, Haryana.
2022_DCSEM_728968_1
QSA/WH MO GCNEP/22-23/NIT/ 29 dt.13.12.2022
Open Tender
Civil Works
275 days
Bahadurgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹17.6 L
Yes
23 Jun 2023
14 Dec 2022
12 Jan 2023
14 Dec 2022
9 Jan 2023
28 Dec 2022
14 Dec 2022 - 23 Dec 2022
Amount
General Abstract of Cost
PART I : CIVIL WORKS
PART I I : INTERNAL PH WORKS
PART III : ELECTRICAL WORKS
PART IV : HVAC WORKS
PART V : FIRE FIGHTING WORKS
Description of Work / Item(s)
Amount
Abstract of Cost for Fire fighting Works
Part V : - Fire fighting works
Description of Work / Item(s)
Amount
Part V : - Fire fighting works Mechanical Works Note: Statutory approvals such as from CFO, local authority, any department of state government shall be obtained by the contractor and no extra payment shall be made.
TERRACE PUMPS Supply, installation, testing & commissioning of Motor driven Centrifugal End Suction Pump Set for fire fighting system of following capacity & head along with all accessories with CI casing, Stainless Steel shaft, standard fittings, bronze impeller, love joy coupling to the electrical driven TEFC, squirrel cage induction motor suitably rated, with synchronous speed not exceeding 3000 rpm, Class-F insulation, IP-55, rated to operate at 415 v +/- 10%, 50 Hz +/- 3%, 3 phase AC supply, including supply of MS common base plate frame and installing pump set on it alongwith suitable cement concrete foundation (design and drawing to be provided by contractor), foundation bolts, coupling guard, anti vibration pads and other accessories & connecting and jointing with suction & delivery piping with necessary reducers, enlargers, flanges etc, complete as per specifications, drawings and as instructed by Engineer-In-Charge. Providing weather proof hood fabricated from 5 mm. thick UV stabilised FRP above each pump & motor to protect it from weather as instructed by Engineer-In-Charge.
i) 450 LPM at 40 m head NB: 1) The cost of all the items mentioned above are to be included under this item and no extra payment shall be made. 2) The sketch/ drg of weather proof cover is to be got approved by E-I-C before fabrication of the same.
M.S SEAMLESS PIPES Supply, Installation, Testing and Commisioning of MS seamless pipe of following Sizes and conforming to ASTM 106 A, Grade B with all fittings, flanges, jointing, supports (Support for piping shall be paid separately) and painting with two coats of anti corrosion paints over two coats of red oxide primer (for laying above ground) and including providing wrapping with 4 mm thick PYPKOTE(corrision protection tape) with adhesive / coats as required(for laying underground) including all the hardware, complete in all respects of work, all as per drawings, specifications and as instructed by Engineer-In-Charge. NB : 1) Making of flanged joints including providing fasteners, blind flanges and gaskets shall be measured under pipelength of this item and no extra payment shall be made. 2) Pipe support shall be paid under Item no. 514
100 mm dia. (Below Ground)
100 mm dia. (Above Ground)
G.I. PIPES Supply, installation, testing and commissioning of Heavy Duty, "C" Class GI pipes of following sizes confirming to IS-1239 (PART-I) along with all necessary fittings, flanges, jointing ( welded / flanged etc.) and required supports with two coats of paint as per color code of the piping systems over two coats of red oxide primer, including all hardware, complete in all respects as per specifications and as instructed by Engineer-In-Charge. NB : 1) The pipe line shall be measured along the centre line.
100 mm dia.
80 mm dia.
65 mm dia.
50 mm dia.
40 mm dia.
32 mm dia.
25 mm dia.
CI GATE VALVES Supply, installation, testing and commissioning of double flanged CI/Cast Steel Gate Valve of required sizes of ratings PN 1.6 with rising stem conforming to IS-14846 with all necessary fittings like flanges, neoprene gaskets, nut bolts, hardware, flange joint etc. as shown in the drawings and as per specifications and as instructed by Engineer-In-Charge.
100 mm dia.
GUN METAL GATE VALVE Supply, installation, testing and commissioning of heavy pattern screw down Gun Metal Gate Valves of following sizes confirming to Class 2 of IS : 778 with hand wheels at top including testing for a pressure of 16 kg/sq.cm. for two hours, all as per specification, drawings and as instructed by Engineer-In-Charge.
50 mm dia.
NON RETURN VALVES Supply, installation, testing and commissioning of double flanged CI/ Cast Steel non return valves of following sizes of ratings PN 1.6 inline with relevant IS(flap/ball type) with gun metal working parts & CI body and including all necessary fittings like flanges, neoprene gaskets, nuts bolts for fixing with pipe, hardware, joints etc. as per drawings, specifications and as instructed by Engineer-In-Charge.
100 mm dia.
SINGLE OUTLET HYDRANT LANDING VALVE Supply, Installation, testing & commisioning of Single Outlet Hydrant landing valve of oblique Morris pattern Stainless Steel (SS-304) landing valve with C.I./ S.S. hand wheel, detachable stainless steel female coupling, conforming to IS-5290/BS-5041 having instantaneous coupling, having 63 mm dia. blank cap and chain conforming to IS-901 to suit the hosepipes, including nuts, bolts, washers, gaskets, with necessary fittings like tees etc. testing the unit, painting the Hydrant landing valve with 2 coats of signal red paint over a coat of Zinc reached primer, all as per specifications and as directed by E-I-C.
2 WAY SIAMESE CONNECTIONS Supply, installation, testing & commissioning of Siamese connections having two numbers of 63 mm diameter G.M/SS inlet (instantaneous male coupling) along with one number 100 mm diameter C.I. double flange non return valve of rating PN 1.6 conforming to IS 5312 with G.M working parts, one number 50 mm dia G.M drain valve of class-2 conforming to IS 778 and fittings all connected to 100 mm diameter MS pipe with necessary fittings including blank caps, flanges and joints, welding etc. and supplying and fixing of inlet housing box made out of 14 gauge M.S Sheet with angle and frame of suitable size and painting with two coats of synthetic enamel paint over a coat of approved primer over pipes and housing box and white enamel paint inside housing box complete in all respects as per specification and as instructed by E-I-C.
HOSE REEL WITH DRUM Providing & fixing rubber hose reel of 20 mm diameter x 37 m along with swinging drum along with high pressure braided rubber hose conforming to IS 884 including 8 mm diameter SS cut off nozzle on one end, wall mounting type, necessary brackets suitable for wall mounting, fixing on wet riser cum downcomer including connecting the other end to the wet riser cum downcomer by providing necessary connecting nipple/coupling, nuts, bolts etc. and providing & fixing 20 mm dia G.M. peet valve of approved make all complete including painting (the drum and brackets shall be painted with two coats of signal red enamel paint from outside and white enamel paint from inside) & as shown and as instructed by Engineer-In-Charge.
HOSE CABINET Supply, installation & commissioning of 1.6 mm thick MS sheet metal hose cabinet of size 750x650x250 mm for accomodating 02 nos. of hose pipes (measured & paid seperately under relevent SOQ item) and SS-304 branch pipe with nozzle or hosy branch pipe with nozzle. The box shall have front glass door lock with angle iron frame. The hose pipe box shall be fixed with Hilti make Anchor Fastner on the wall or nut bolts (in case of stand in open space) as shown in the drawing and as directed by EIC. The MS box shall be painted with two coats of signal red enamel paint from outside and white enamel paint from inside. The scope also includes supplying of gun metal / stainless steel branch pipe of 63 mm dia. fitted with detachable hexagonal nozzle of 19 mm dia. conforming to IS : 903 or universal pattern as per IS : 2871. The branch pipe with detachable nozzle shall be placed in the hose cabinet complete in all respect as instructed by Engineer-In-Charge.
HOSE PIPE (For Hydrants, Landing Valve) Supply and installation of Unlined Flax Canvas (hose pipe) for fire fighting conforming to RRL fire hose type A or Synthetic Fibre Woven-Jacket (SFWJ) Elastomeric fire hose type B conforming to IS:636 all with ISI marks as required and of approved make and of 63 mm dia & 15 mtrs length, fitted with male and female SS coupling confirming to IS:903, ISI marks with guaranteed bursting pressure of 35.7 kg/sq.cm and complete as per the technical specifications and as instructed by Engineer-In-Charge. Each set shall comprise of 2 hose pipes.
PRESSURE GAUGES (Range of 0 - 10 Kg/cm2) Supply, installation testing and commisioning of pressure gauges of SS material with dial not less than 150 mm dia of appropriate range and complete in all respects with shut off gauge, cocks , all fittings etc, duly calibrated before installation in MKS and FPS units and duly tested after installation as per drawing and as instructed by Engineer-In-Charge.
AIR RELEASE VALVES Providing and fixing 20/25 mm dia. (PN - 1.6, Type-S1, Flanged, ISI marked) air release valve conforming to IS - 14845 : 2000 with Double Flange isolating valve (pressure rating PN 1.6) including making necessary flanged joints and providing all fitting materials nuts, bolts etc. and providing T on the pipeline for its installation at site all as per technical specification, drawings and as instructed by Engineer-In-Charge.
M.S. SUPPORTS/ STRUCTURE Supply, cutting, fabrication, welding, erecting & fixing in position of M.S. support/structure (angle, channel, beam, plate, chequered plate etc.) for steps and other purpose (not applicable for items for which supports are already included in the item) including painting with two coats of synthetic enamel paint of approved make & shade over a coat of approved steel primer all as instructed by Engineer-In-Charge. Material shall conform to IS-2062.
VALVE CHAMBERS Construction of brick masonary valve chambers made out of 230 mm thick brick masonry in cement mortar 1:4 over a bed of 150 mm thick cement concrete of grade M-15 for foundation with 150 mm extended all round the walls, including providing and fixing suitable size staircase for landing inside the chamber. The staircase shall be fabricated out of 25 mm dia. M.S pipe and 6 mm thick M.S Sheet suitably painted with 1 coat of primer and 2 coats of synthetic enamel paint. Racking out joints & plastering in cement mortar 1:3, 20 mm thick both on internal and external surfaces, internal surfaces finished smooth with a floating coat of neat cement. Providing 6 mm thick Aluminum chequered plate in sectional construction with suitable lifting arrangement and painting. It shall be complete as per technical specifications, drawings and as instructed by Engineer-In-Charge. NB.: The cost of all the items mentioned above is to be included under this item and no extra payment shall be made.
1.0 m width x 1.0 m length x 1.2 m depth
PENDENT SPRINKLERS Supply, installation, testing & commissioning of 15 mm dia recessed sprinkler with quartzoid bulb and set to operate at 68° C, with rosette plate [Pendent type Sprinkler (K-80), FM & UL approved] and complete in all respects per specifications and as instructed by Engineer-In-Charge.
UPRIGHT SPRINKLERS Supply, installation, testing & commissioning of 15 mm dia upright sprinkler with quartzoid bulb and set to operate at 68° C [Upright type Sprinkler (K-80), FM & UL approved] and complete in all respects as per specifications and as instructed by Engineer-In-Charge.
FLEXI DROPS Supply, installation, testing & commissioning of sprinkler flexible drop pipes made of corruggated SS tubing to withstand 16 bar pressure with welded reducer on one end to directly accomadate sprinkler & female checknut on the other end to connect to the branch pipe with supports complete [Length 1.5 mtr, FM & UL approved]
FIRE ALARM VALVE Supplying, installation and fixing in position 150 mm dia fire sprinkler alarm valve HD / TYCO make with inlet and outlet connections, pressure gauges etc complete as per drawings, technical specifications and as instructed by Engineer-In-Charge.
FIRE EXTINGUISHERS
Proividing & fixing of Dry Chemical Powder (ABC) type fire extinguisher of 04 Kg capacity either portable or trolley mounted as per approved make fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS 15683-2006. The Fire extinguisher shall be supplied and placed without any damage, scratches and loss of accessories as per specifications and as instructed by Engineer-In-Charge.
Providing & fixing of CO2 type fire extinguisher of 4.5 Kg capacity either portable or trolley mounted, highly effective against B & C class of fire, having ISI certification mark, having flat base including valve, discharge hose & complete in all respects including initial fill with CO2 gas conforming to IS 15683:2006, wall suspension bracket as required & as per instructions of Engineer In Charge. The Fire extinguisher shall be supplied and placed without any damage, scratches and loss of accessories as per specifications and as instructed by Engineer-In-Charge.
Description of Work / Item(s)
Amount
Abstract of Cost for Civil Works
Part IA : Sub-structure
Part IB : Super-structure (Structural)
Part IC : Form work
Part ID : Steel Reinforcement work
Part IE : Masonry work
Part IF : Flooring work
Part IG : Doors and windows
Part IH : Fittings and Fixtures
Part II : Waterproofing treatment
Part IJ : Plastering work
Part IK : Painting work
Part IL : Miscellaneous work
Description of Work / Item(s)
Amount
PART - I :-Civil Works PART I-A : SUB STRUCTURE
Earth work excavation over areas by mechanical means (Hydraulic excavator)/ manual means to required profile, level, grade, camber etc. in all soils as mentioned below (exceeding 30cm in depth, 1.50m in width as well as 10sqm on plan area) for mass excavation including dressing of excavated area, filling the plinth/ low spots/ areas with approved excavated earth in layers not exceeding 150 mm, watering, consolidation to obtain 90% proctor density etc. and stacking/ disposing the surplus excavated materials within a lead of 300 m and all inherent lifts etc. to the required location etc complete all as per specification, drawing and as directed by the Engineer-in-Charge.
In all soil other than soft & hard rock.
In soft rock.
In hard rock by chiselling or by using machines such as poclain with jack hammer etc.
Depth not exceeding 1.50 m. from ground level.
Depth exceeding 1.5m & upto 3m from ground level.
Depth exceeding 3.0 m & upto 4.5m from ground level.
Depth not exceeding 1.50m from ground level.
Depth exceeding 1.5m & upto 3m from ground level
Depth not exceeding 1.50 m. from ground level.
Depth exceeding 1.5m & upto 3m from ground level.
Construction of cast-in-situ RCC bored piles using rotary drilling method as per IS 2911 (Part-I, section-2) latest revision using concrete of M-30 grade with minimum cement content of 400 kg/cum of concrete, including cost of all materials, labour, use of plant and machinery, casting of pile to plumb, rectifying defects if any, including empty boring if any, breaking pile heads, dewatering, bore hole stabilization using temporary casting/ bentonite, disposal of the excavated muck/ bentonite slurry, broken pile heads to suitable dumping area as approved by statutory authority outside the campus including all lead by mechanical transport etc. (but excluding the cost of steel reinforcement which shall be paid under relevant item), all as per drawing,and specification etc., complete & as directed by the Engineer-in-charge. Please refer additional notes
600 mm dia. piles of length upto 18.00 M length from cut off level for design load of 55T for vertical load, and 4.7T for lateral load with free pile head.
600 mm dia. piles of length exceeding beyond 18.00 M length from cut off level for design load of 55T vertical load, and 4.7T for lateral load with free pile head.
Extra for RMC (Ready Mixed Concrete) for pile confirming to IS 4926 (latest) in lieu of conventional RCC for pile supplied by approved RMC manufactures including transporting, pumping etc. complete as per instruction of the Engineer in charge.
For 600 mm dia pile
Carrying out routine pile load test for : Working capacity of 55T for vertical load, using maintained load method as per IS-2911 (Part-4) latest edition using hydraulic jack & dial gauges including all supporting arrangement, kentledge, it's transport, loading, unloading etc. complete (Hydraulic jack and dial gauges shall be got tested / calibrated from NTL or any other approved Laboratory before use on works)
Routine Lateral load testing of single pile with free pile head for working capacity of 4.7T in accordance with IS 2911 (Part-4) latest for determining safe allowable lateral load on pile etc. complete as per drawing, as per technical specification and as directed by the Engineer in charge.
Cement concrete for the following works at all levels and locations of specified mix using graded stone aggregate of 20mm. maximum size including necessary form work, machine mixing, transporting, placing in position, consolidation, finishing, curing etc. complete as per specifications, drawings and as directed by the Engineer-in-Charge. Note:- Nominal reinforcement if provided shall be measured & paid under relevant item.
P C C M-10 grade in bed concrete to foundations, pedestals, encasing etc.
PCC grade M15 in sub base flooring, plinth protection , storm water drain, foot path , pavement, coping haunches etc.
For all type of structural / RCC elements
Extra for providing RMC (Ready Mixed Concrete) confirming to IS : 4926 (latest) in lieu of conventional RCC and PCC items supplied by approved RMC manufactures for all type of structural elements/ RCC elements including transporting, pumping etc. complete as per instruction of the Engineer in charge. Notes: i) The contractor shall obtain prior approval of RMC manufacturer from Engineer in Charge in writing. ii) This item shall be measured in addition to the original items of RCC and PCC mentioned elsewhere in schedule of quantities substructure., iii) The rate shall apply for all levels and locations including all type of structure etc. complete. iv) Extra for RMC in lieu of conventional RCC and PCC of any grade mentioned elsewhere including SWD etc. shall be measured and paid under this item for sub structure
Providing, erecting, fixing in position striking / removing and cleaning steel / timber shuttering & centering for form work in foundation, plinth at all levels and locations for all geometrical shapes in plain, curved surfaces of structural / RCC elements including chamfers, splays, keys, wedges, props, rails, bracings, brackets, cutting holes for pipes etc., providing & applying approved form oil on all surfaces of form work coming in contact with concrete including close hacking of all exposed concrete work after removal of form work, all materials, labour etc. all complete as per specifications, drawings and as directed by the Engineer-in-charge. Note:- a) Area of form work in contact with concrete shall only be measured for payment. (stop boards for construction joints will not be measured for payment). b) The rate of formwork shall include all type of structural / RCC elements and geometric shapes including circular and any other curved surfaces.
Reinforcement for RCC work including supplying, delivering, storing of various diameters as required at site of work including loading, unloading, transporting, decoiling, straightening, cutting, bending, placing in position at all locations & levels and binding with 18 gauge, soft drawn annealed steel binding wire including carrying out various tests as required etc. all as per specifications, drawings & as directed by the Engineer in charge.
Thermo Mechanically Treated bars of grade Fe-500 D manufactured by SAIL, TATA STEEL, JSW and RINL only. Note:- The cost of binding wire shall be borne by the contractor and binding wire shall not be measured for payment.
Brick masonry work in foundation and plinth, cable pits, trench, steps, storm water drain, footpath etc. at all locations using well burnt bricks from approved lot, of class designation 7.5 (classification as per IS 1077-1992 and min. average compression strength not less than 7.50 N/mm2 ) in C.M 1: 6 to correct line, level and plumb including raking out joints / simultaneous flush pointing with cement mortar 1:4, curing etc. complete as per specifications, drawings and as directed by Engineer in charge. Notes for brick masonry:- i) One brick wall thickness shall be considered as 230 mm & lesser wall thickness if any shall be made up accordingly by the contractor by applying cement mortar of mix 1:4 in proper line, level & plumb without any extra,cost to the department. ii) The rate shall include cost of making the brick masonry to all geometrical shapes and sizes without any extra cost to the Department. iii) The contractor shall get approved the samples of bricks from the Engineer-In- Charge before procurement on large scale and shall maintain the same for the entire work iv) Necessary openings, nitches, cut-outs, wherever required as per drawings and asked for by the Engineer-In-Charge, shall be provided by the contractor without any extra cost.
Cement plaster in single coat of 20mm thickness with cement mortar 1:4 mix for internal brick/concrete surfaces for all walls and beams flush with walls, mullions , UG tank, cable pits, trenches, chambers, steps, storm water drain, top of coping etc. at all levels, heights, slopes and location on plane or curved surfaces including preparing the surface even and smooth to correct line, level, plane and plumb including scaffolding, curing etc complete as per drawing, specification and as directed by the Engineer in Charge. Notes for plastering works a) Before commencement of plastering, the area shall,be cleaned, wetted and shall be marked with 'Thiyyas' or 'Tapanis' and shall be got approved by the Engineer in Charge. b) No extra claim/cement consumption shall be entertained by the Department for the plastering done more than the specified thickness shown in the schedule of quantities, to bring the plastered surface to perfect line, level and plumb with adjoining columns and beams.
20mm thick smooth finish in two coats with a coat of neat cement with 2% water proofing compound.
Sand faced plaster in two coat cement finish with water proofing compound @ 2% by weight of cement or as per manufacturers specifications.
Providing & spreading of red garden soil free from stones, pebbles, grass , weeds etc. at site brought from outside borrow as per specification and directed by the Engineer-in-Charge. Note: The measurements will be taken as per truck body diamensions filled with red soil without any deduction for voids.
Disposing off the surplus excavated materials /debris etc. beyond initial lead as mentioned in relevant items by mechanical transport to the near by dumping pits/ dumping areas inside campus with all leads including all lifts, loading, unloading, stacking, spreading, levelling etc. complete as per drawings, specifications & as directed by the Engineer in charge., Note :- i) Voids @ 20% for soils and 50% for soft rock/ hard rock shall be deducted from fully loaded truck measurements to arrive at the net quantity for payment in case direct measurement is not possible. ii) Royalty for excavation, transportation, filling of earthwork etc. including obtaining permission from statutory authority, if any shall be borne by the contractor.
Providing and laying dry rubble stone hard core soling of following consolidated thickness in sub base to floor, in plinth protection, footpath and other miscellaneous works to required levels and lines with first quality rubble, hand set, well packed including filling the interstices with smaller stone chips, supplying & finishing / blinding the surfaces with approved blinding quality moorum including watering, consolidation etc. complete as per specification, drawings & as directed by Engineer in charge.
230mm consolidated thickness.
150mm consolidated thickness.
Supplying and spreading pesticides CHLORPYRIPHOS or other chemical approved by central insecticides board as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-construction anti-termite treatment (at the rate of 7.5 liters per sq.m. on vertical surface and 5 ltrs. per sq.m. on horizontal surfaces(or as directed by the manufacturer ) within the trenches, 50% of the emulsion to be filled in the holes made in trenches at 150mm. centre to centre etc. complete as per IS 6313 Part-II. (The payment will be made on the basis of plinth area measurement only at ground floor/stilt area for all stages of operation and vertical face will not be measured for payment) all complete as per specifications, drawings and as directed by the Engineer in ,charge Notes :- a) This item will be executed through approved agency who is a member of Indian Pest Control Association, approved by Central Insecticides Board. b)The contractor shall have to furnish ten years guarantee in the prescribed proforma as per Section-10(iv) Conditions and clauses of contract-2008 to maintain the anti-termite treated area/structure free from termite. c) Prior approval of Engineer in Charge shall be obtained after testing the chemical for antitermite to be used and shall be tested in approved laboratory and to be submitted to Engineer in Charge. Cost of testing shall be included in the rates quoted.
Providing and laying damp proof course 50mm thick at plinth level in cement concrete 1:2:4 using 10mm. maximum size and down graded stone aggregate, mixed with approved water proofing compound at 2% by weight of cement laid to levels, slopes etc. including applying a coat of hot bitumen of grade 80/100 at 17 kg./10 sq.m. including cost of form work, curing all complete as per specifications & as directed by the Engineer in charge.
Providing random rubble masonry with rough dressed hard stone below plinth in foundation, plinth, retaining wall, culverts, storm water drains and other structures etc. in cement mortar 1:6 including through stone, header stone, bond stone, quoins etc. well packed including filling the interstices with smaller stone chips, striking, raking out joints & finishing the joints, including scaffolding, curing etc. all complete as per specifications, drawings and as directed by the Engineer in Charge.
Cement pointing to random rubble masonry wall with cement mortar 1:3 including raking out joints, pointing neatly and finishing the joints, curing scaffolding etc. complete all as per specification, drawing and as directed by the Engineer in charge.
Raised and cut pointing
Providing following class RCC Hume pipe of following sizes, laying / burrying underground including making holes in masonry/ concrete work wherever required, making good the holes after laying the hume pipe with collar joints for required class using stiff mixture of cement mortar (1:2) and sealing open ends with wooden bush(only for electrical cable entry humes pipes) and remaining open for road crossing, culverts and storm water drain etc. all complete as per specifications & as directed by the Engineer in Charge.
NP2 class RCC hume pipes of 150mm dia.
NP3 class RCC hume pipes of 250mm dia.
Structural steel work in frames, covers, using angles, tees, flats, bars, chequered plates, inserts fabricated out of mild steel bars, ISMC, ISMB, angles, pipes, plates and diaphram plates for expansion joints etc. of all shapes, sizes including supplying, cutting, fabricating, welding, erecting, making holes/chases wherever required and fixing /embedding in position in concrete/brick work with necessary hold fasts/ screws & rawl plugs and finishing the concrete/ brick work after fixing /embedding including painting two coats of anticorrosive bitumastic paint on all unexposed surfaces and two coats of synthetic enamel paint of approved make and colour on all exposed surfaces,over a coat of approved steel primer etc. complete as per specifications, drawings and as directed by the Engineer in charge.
TOTAL OF PART I - A : (Sub Structure)
PART I-B : SUPER-STRUCTURE (STRUCTURAL) Notes :- Super structure items included in this schedule pertain to all the works above plinth level upto roof including parapets, water tanks,machine room, terrace level works etc. unless specified otherwise.
Reinforced cement concrete of grade M-30 in super structure conforming to IS 456-2000, at all floors and levels for all structural members in all geometrical shapes / design using graded stone aggregate of 20mm and down graded including machine mixing, conveying, placing in position, mechanical consolidation, finishing, curing, etc. complete all as per drawings, specifications & as directed by Engineer in Charge. Notes for reinforced cement concrete a) All RCC works shall be controlled concrete unless otherwise specified and shall be carried out strictly in accordance with the drawings, specifications and as directed by the Engineer in Charge., b) The minimum cement content for water tank shall not be less than 330 kg/cum and not more than 400 kg/cum. c) The rates for RCC works shall be exclusive of cost of reinforcement and form work unless otherwise mentioned. d) All coarse aggregate to be 20mm. maximum size and uniformly graded unless otherwise mentioned. e) For all RCC items, the rates quoted shall include the following without any extra cost to the Dept. i) Fixing at correct level and in proper alignment the inserts, pipe sleeves, pipe bends, fan hooks, lift hook, other pipe, specials etc.supplied by / through the Department. ii) Cut outs,nitches,pockets , construction joints etc. f) Test for concrete shall be done as per IS 456-2000 and the cost of the same shall be borne by the contractor.
For all type of structural / RCC elements
Extra for providing RMC (Ready Mixed Concrete) conforming to IS 4926 (Latest) in lieu of conventional RCC items, supplied by approved RMC manufacturers including transportation, pumping etc. complete as per instruction of Engineer in Charge. Notes: i) The contractor shall obtain prior approval of RMC manufacturer from Engineer in Charge in writing. ii) The rate shall apply for all levels and locations including all type of structure etc. complete. iii) Extra for RMC in lieu of conventional RCC of any grade mentioned elsewhere including road etc. shall be measured and paid under this item.
TOTAL OF PART I-B : [ Super Structure ~ Structural ]
PART - I-C : FORM WORK Notes:- a) For double/ multi stage shuttering design calculations and details / drawings for scaffolding shall be submitted by the contractor well in advance. Prior written approval of form work shall be obtained from Engineer in Charge, before commencement of work. b) Area of form work in contact with concrete shall only be measured for payment & stop boards for construction joints etc. will not be measured for payment. c) The rate for formwork shall include all type of structural/ RCC elements and all geometrical shapes including circular and any other curved surfaces at all height and locations with independent staging having adequate additional bracing, propping, intermediate/ multiple staging wherever required.
Providing, erecting, fixing in position, striking / removing and cleaning steel / timber shuttering & centering for form work at all level & locations for all geometrical shapes and designs as per drawings including rails, bracings, props, brackets, cutting holes for pipes etc., providing & applying approved form oil on all surfaces of form work coming in contact with concrete including close hacking of all exposed concrete work after removal of form work, all materials, labour etc. complete as per specifications, drawings & as directed by the Engineer in charge.
All type of structural / RCC elements including all geometric shapes and single / multiple staging at all floors and location.
Providing, erecting, fixing, centering, shuttering work using ply board to obtain form finished concrete surfaces of F3 finish to ceilings including pergola & other architectural features etc. at all heights & locations for following including single / multiple staging at all floors and locations, for all geometrical shapes in plane, curved surfaces of structural / R C C elements including chamfers, splays, keys, wedges, props, rails, bracings, brackets, cutting hole for pipes etc. providing and applying approved form oil to all surfaces of formwork coming in contact with concrete and striking / removal of the same including finishing by filling form tie holes, removal of fins, ridges, and,irregularities by grinding filling air holes, with sack rubbed finish, cleaning up loose and adhering debris including all materials labour etc. complete as per specifications drawings and directed by Engineer in charge.
At all floors and locations including single/ multiple staging etc.
Total of PART I-C : (FORM WORK )
PART - I-D : STEEL REINFORCEMENT WORK
Reinforcement for RCC work including supplying steel bars of various diameters as required at site of work including loading, unloading, transporting, decoiling, straightening, cutting, bending, placing in position and binding with 18 gauge, soft drawn annealed steel binding wire including carrying out various tests as required etc. all as per specifications, drawings & as directed by the Engineer in charge. (Cost of binding wire shall be borne by the contractor & shall not be measured for payment).
Thermo Mechanically Treated bars of grade Fe-500 D manufactured by SAIL, TATA STEEL, JSW and RINL only.
Total of PART I-D : REINFORCEMENT STEEL
PART - I-E : MASONRY WORK Notes:- (a)The contractor shall get approved the samples of bricks from the Engineer-In- Charge before procurement on large scale and shall maintain the same for the entire work. b)Necessary Openings/nitches/cut-outs, wherever required as per drawings and asked for by the Engineer-in-Charge, shall be provided by the contractor without any extra cost. c) One brick wall thickness shall be considered as 230mm and lesser wall thickness if any shall be made up to the required dimensions by the contractor in CM 1:4 to proper line, level and plumb without any extra cost to the Department. d) The rate shall include cost of making the brick masonry to all geometrical shapes and sizes without any extra cost to the Department.
Brick masonry 230mm thick in super structure at all floors and locations using solid fly ash bricks conforming to IS12894 latest edition from approved lots of class designation 7.5 (with min. average compressive strength not less than 7.50 N/mm2 ) in CM 1:6 in walls to correct line, level and plumb including raking out joints, curing, scaffolding etc. complete as per specifications, drawings & as directed by Engineer in Charge.
Providing solid fly ash brick work 110mm thick in partition walls, dwarf walls, parapets, under platforms, curtain walls, fins, external boxing etc. at all floors and locations as per drawing conforming to IS12894 latest edition from approved lots of class designation 7.5 (with min. average compressive strength not less than 7.50 N/mm2 ) in C.M 1:4 to correct line, level & plumb including scaffolding, raking out joints, curing etc. complete as per specifications drawings & as directed by the Engineer in charge. a) With 100mm.wide and 80mm. thick RCC (1:2:4) stiffeners at every one metre height including formwork but excluding the cost of steel reinforcement, which,shall be paid under relevant item.
Total of PART I-E : MASONRY WORKS
PART -I-F : FLOORING WORK Notes : a) The floor finish level shall be generally in level matching with the surrounding floor finish level. No extra payment shall be entertained for matching the floor differences. b) Adjustment of levels in thickness of mortar bedding due to different types of flooring, if any, shall be done by the contractor without any extra cost to the Department. c) The contractor shall submit and get approved the sample for flooring, skirting, dado tiles from Engineer in,Charge before bulk procurement. d) Pattern & design of flooring/ skirting/ dado shall be approved by the Engineer in Charge before commencement of work. e) Exposed edges of all natural stones used for the works like Kotah, Marble, Granite etc.shall be machine cut and shall have uniform thickness and mirror polished unless otherwise mentioned. f) The rate shall include cost of making the flooring to all geometrical shapes and sizes without any extra cost to the Department. g) All Kota stone work shall be mirror polished to get high gloss finish and the rate shall be inclusive of the same in the respective item. h) The sizes of stones/ tiles mentioned for flooring are approximate and subject to the availability in market during execution. If the required size is not available the next higher size of tiles/ stones shall be used without any extra cost to the Department.The contractor may quote accordingly i) Wherever dissimilar floor finishes are placed adjacent, 3mm thick x 25mm wide aluminium flat dividing strips shall be provided by the contractor without any additional cost to the Department.
Providing machine mixing and laying in approved panels of 40mm thickness IPS flooring in cement concrete mix of 1:2:4 using graded stone aggregate of 12.5 mm maximum size with colouring pigment, at all level, well vibrated, compacted including providing and fixing 25 mm x 3 mm thick aluminium dividing strip for panel of about 2 sqm size, to correct level and finished smooth and curing including preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond, all complete as per specification drawing & as directed by Engineer in Charge.
Cement plaster 18mm thick in skirting with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement correct to line, level and plumb including rounding of junctions with flooring etc. complete as per specifications and drawings & as directed by Engineer in charge.
Cement concrete floor of 50mm thick with hardener finish at all floors and locations, consisting of under layer of 38mm thick cement concrete in grade 1:2:4 with 12mm. size aggregate and top layer 12mm. thick metallic concrete hardner wearing surface, cement being mixed with metallic flooring hardner of approved make in proportion of 4:1 (4 cement : 1 metallic floor hardner) by weight and cement hardner compound mixed with 6mm down graded stone aggregate in the ratio of 1:2 by volume including form work, consolidation finishing to required level, slope, Broom finish with groove where specified, curing including providing aluminium dividing strips of size 25x3mm for panels of about 2 sq.m size. etc. complete as per specifications & drawings,and as directed by the Engineer in charge.
Providing & laying at all floors & locations with vitrified tile of "Duragres" series of M/s Somany or approved manufacturer of approved colour and size as given below (thickness shall be as per manufacturer's specifications) conforming to IS-15622 in flooring / skirting / dado/ clading at all floors and location in approved pattern and colour laid over cement mortar bedding/ backing, close jointed and grouted with white cement slurry and including 3 mm thick and 8 mm deep grout line using PVC spacers for creating true alignment and gap between vitrified tile flooring & Skirting at specified places as per drawings / as directed and grouting the joints with matching epoxy tile grout of approved manufacturer, mixed with approved pigment as per manufacturer's,specifications, finished to level, line, slope and plumb, cutting of tiles, wastage, making openings / cut out if neccesary, final cleaning of surfaces, curing etc. complete all as per drawings, specifications & as directed by Engineer in charge. In flooring laid over 20mm thick cement mortar 1:4 (1 cement : 4 sand) bedding, in dado laid over 12mm thick CM 1:3 (1 cement : 3 sand) backing, in skirting including slopped skirting laid over 12 mm thick CM 1:3 ( 1 cement : 3 sand) backing including providing grooves as per drawing on top of skirting.
Vitrified tile of size of 600mm x 600mm/100mm x 10mm thk (or thickness as per manufacturer's specification) glossy/satin matte finish.
Anti skid fully Vitrified tile of size 600mm x 600mm x 10mm (or) thickness as per manufacturer's specification, satin matte finish. Note : i)The sizes of tiles mentioned are approximate and subject to the availability in market during execution. If the required size is not available the next higher size of tiles shall be used without any extra cost to the Department. The tenderer may note the same and quote accordingly.
Providing & laying machine cut & machine polished kotah stone flooring at all floor & location including stair case landing, connecting corridoor etc. necessary cement mortar bedding / backing, close jointed & grouted with matching cement slurry and finished to line, level, curing etc. as required, including cutting of stone slab, wastage, making cut outs,wherever required, machine polishing /hand polishing (where machine cannot have access) etc. complete all as per specifications, drawings and as directed by the Engineer in charge. a) In flooring with machine polished kotah stone slab of size 575x575x 25mm/ 550x550x25mm/ 550x500x25mm/ 600x600x25mm thick laid over & including 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) bedding. b) In skirting including slopped skirting with machine polished kotah stone slab of size 575/550x100x20 mm thick or sizes as per working drawing laid over and including 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) backing including providing grooves on top of skirting, and chasing the brick masonry etc. complete.
Providing & laying machine cut and machine mirror polished (pre-polished) kotah stone for treads / risers / steps / ramps etc as mentioned below, laid over cement mortar bedding/ backing, close jointed and pointed with matching cement slurry and finished to line, level plumb etc. as required, including curing, cutting of stone slab, making cut outs, wherever required, wastage etc. to get true square edges and final hand polishing all as per specifications, drawings & as directed by the Engineer in charge. a) For treads 25mm uniform thick in single piece in length up to 1500mm (approx.) laid over 20mm thick,cement mortar 1:4 (1 cement :4 sand) bedding, including providing factory cut three Nos. of antiskid 12x3mm @15mm centre to centre grooves including half round moulding / champhering the edges polishing etc.complete. b) In riser 20mm/18mm uniform thick in single piece in length up to 1500 mm (approx.) laid over 12mm thick cement mortar 1:3 (1 cement :3 sand) backing including making recess at top and bottom as shown in drawing complete. Note: i)The tread and risers are to be polished at factory. The exact size are to be laid without any further cutting and polishing. ii) The grooves are to be cut at factory to maintain the gap uniform. Non uniform groove size and irregular gaps between grooves shall not be accepted and rejected forthwith iii) The contractor is to take appropriate step to protect the polishing surface of the floor, tread and riser by providing and laying 6mm thick POP during construction period. The surfaces are to be cleaned only at the time of handing over.
Providing and fixing vitrified clay tiles of approved manufacture at all floors and location of size 230mm x 115mm x 10mm/ 200mm x 100mm x 10mm or approved size, colour and shades with approved combinations etc. for cladding over sloped / vertical wall, parapet, chajjas, facia, fins etc. of all geometrical shape with 12 mm thick 1:3 cement mortar backing and fixing the tiles with approved quality exterior grade, tile adhesive of M/s. Fosroc or at par approved quality of approved manufacturer and pointing the joints with matching cement , in plumb, line, level, scaffolding including double scaffolding all complete as per specification, drawings and as directed by the Engineer in Charge. Note: The size of tiles mentioned are approximate and subject to the availability in market during execution. If the required size is not available the next higher size of tiles shall be used without any extra cost to the Department. The tenderer may note the same and quote accordingly.
Providing and fixing 6mm thick POP protection cover to granite/ vitrified/ceramic tile floors over polythene covering sheet to flooring areas till handed over to users; it shall be removed and disposed off prior to handing over and cleaning, etc. all complete to the entire satisfaction of the Engineer in Charge.
TOTAL OF PART I F : FLOORING
PART I-G : DOORS AND WINDOWS Notes : a) The items of door frames, window frames shall include sealing the joints all round with the brick work /concrete and doors or windows with approved mastic filler cement grout/ epoxy compound /polysulphide compound by the contractor at his own cost as directed by the Engineer-in-Charge to make the joints watertight. b) The work contemplated under the item for supplying and fixing the window/door frames shall be got done by the contractor through specialised agencies in the field, approved by the Department. c) One sample each of the door frame, shutter and window,with all fittings and fixtures alongwith locking arrangement including glass panes etc. complete as per schedule of quantities, drawing and specifications should be submitted for preliminary inspection before procurement on large scale. The contractor shall submit six copies of shop drawings for windows, ventilators and steel door with frames showing dimensional details of construction etc. for approval of the Engineer-in-charge. After preliminary inspection, the sample should be fixed. Defects etc.if any shall be rectified to the full satisfaction of the Department and after obtaining formal approval in writing of Engineer in charge. d) Door frames, shutters and the windows to be supplied and fixed in position should cater the dimensional tolerance of the openings to an extent of (+/-) 2%. The rates quoted by the tenderers should hold good for such variation. Test shall be conducted by the Department for the flush doors as per IS-2202-1983 Part-I from each consignment and the cost incurred on this account shall be borne by the contractor. e) For bonding the flush doors, block boards, ply wood and all types of wood works, phenol- formaldehyde synthetic resin type adhesives conforming to IS-848-1957 shall be used. f) The rate shall include cost of making the doors & windows including glass etc.in all geometrical shapes and sizes without any extra cost to the Department.
Providing and fixing in position at all height and location approved quality second class teak wood moulded, rebated door frames & frames for exhaust fan/ A C / grills etc.wrought and finished sizes, conforming to IS : 4021-1967 at all height and location, including making holes in concrete/ masonry walls and providing and fixing MS hold fasts 300x30x3mm thick embedded in plain cement concrete 1:3:6 in case of brick work and M S coach screw 100mm long or equivalent size in case of RCC/ stone works including painting two coats of bitumastic paint for all unexposed surfaces coming in contact with concrete/ brick masonry,polishing three coats of melamine polish/ painting the exposed surface,with two coats of synthetic enamel paint of approved make and shade over a coat of approved primer wherever required etc. complete all as per drawings, specifications, and as directed by the Engineer in Charge.
a) Profile 145 x 60 mm with single rebate.
Type D8/D9A-40mm thk. Approximate size 750/900 x 2200 mm both side pre laminated solid core block board single leaf side-hung flush door shutter with/without vision panel as per drawing. Note:- Decorative lamination sheets shall be hot pressed at factory during manufacturing of door shutters.
For terrace door and for WC door of size as per drawing with 25 mm thick factory made PVC integral free foam sheet single leaf side hung door shutter in form of flush finish door.
Supplying, fabricating and fixing in position at all floors and location approved colour powder coated aluminium extruded section for Aluminium doors/ windows sliding/ top hung/ fixed/ adjustable louvered windows as per drawing using approved extruded sections of Jindal/ Indal/ Hindalco or other approved manufacturer of all geometrical shape and design with size and standard weights as per approved fabrication drawing, for frames and shutters as per specifications and conforming to relavant IS standard including providing and fixing approved quality, colour anodised aluminium fittings and accessories such as handles, push plate, concealed/ exposed tower bolt, necessary locking arrangements, door lock, butt/ SS friction,hinges, rollers with ball bearings etc. of approved quality as required for openable/ sliding shutters and as per approved fabrication drawing, including providing and fixing aluminium channel beading/ glazing clips fixed with approved colour anodised/ powder coated screws, grouting the gap with thermocole & polysulphide sealant etc. all complete (including all wastages) as per drawings, specifications and as directed by Engineer in Charge. Please refer additional notes
Providing and fixing following type of approved quality glass panes/ laminated board for doors/ windows/ ventilators, of all geometrical shape and design glass of M/s. Saint Gobain/M/s. Modi Guard, fixing with aluminium frame work including fixing aluminium channel beading (to be paid under relevant item) and providing and fixing with 2 way EPDM gasketing, to ensure water and air tightness and neoprene cushions /gasket accommodated in grooves, necessary approved colour powder coated screws etc., all complete generally as per drawings specifications and as directed by the Engineer in Charge.
6mm thick toughened clear float glass
6mm thick clear float glass
4mm thick ground glass/ frosted glass.
12mm thick prelaminated external grade board of approved colour and shade of approved manufacturer
Providing and fixing reflective toughned Glass of thickness as indicated below in approved colour of M/s Saint Gobin, silicon sealant structural grade and weathering grade shall be DOW Corning - USA or G.E. Silicon - USA or WACKER Germany of Silicon byte size as per design including providing and fixing both side adhesive tape NORTON make or TROCILLEN and also using backer foam of TROCILLEN as per drawing complete as per specification and standard sound practices using all necessary materials including scaffolding etc.all complete as per specification drawings and as directed by Engineer in Charge.
Structural Glazing of 12mm thick platinum colour reflective toughened glass with low E value as per specification for fixed panel.
Structural glazing with laminated glass of overall thickness 17.52mm comprising of 10mm thick platinum colour reflective toughened glass with low E value outside +1.52mm PVB membrane+6mm thick clear toughened glass inside, for spandrel glass panel.
Providing & fixing in position approved quality 2nd class teak wood architraves of finished section for the following sizes fixed to pressed steel frames of door/ cup board/ MS doors at all floors as per drawing including providing and fixing M.S. self taped screws at 600mm center to center or suitable spacing as instructed by Engineer in Charge, painting with two coats of synthetic enamel paint of approved make & colour over one coat of approved primer/ 3 coats of melamine polishing of approved shade and tint etc. all complete as per specification & drawings and as directed by Engineer in charge.
With size 45mm x 15mm with chamfer 2x2mm and 3x3mm etc. as per drawing.
TOTAL OF PART -I-G: DOORS & WINDOWS :
PART : I-H : FITTING & FIXTURES: Notes:- i) One sample board consisting of each item of schedule of quantities with approved quality fittings & fixtures & necessary accessories including stainless steel screws, bolts, nuts, washers should be submitted for approval of Engineer-in- charge. Large scale procurement shall be taken up only after approval of the Engineer-in-charge. After approval, the samples shall be kept in the office of the Engineer-in-charge to ascertain the approved quality for the entire work. ii) All fittings & fixtures shall conform to relevant IS code.,
Supplying at project site non magnetic stainless steel (SS 304) fittings, fixtures and fasteners along with necessary SS screws, bolts, nuts, washers etc. wooden packing pieces if necessary and other standard accessories of M/s. Dorma or at par quality of approved manufacture
Stainless Steel premium quality Butt hinges of size 125x76x3mm as per IS code.
Door stopper with twin rubber bushing (shutter mount type)
SS Tower bolt 300mm. long x 12mm dia. barrel.
D type fancy bow handle 150mm long
Stainless steel Aldrop 300mm long x 16mm dia. rod with extra stapple.
Providing & fixing heavy duty hydraulic Door closer of approved manufacturer for door shutters as directed by Engineer in charge.
Supplying anf fixing 6-lever Mortice lock of chromium plated brass parts & body similar to M/s. Godrej make model no. 7117, 200mm Handle Set Lock Body CK mortice lock with chromium plated brass screws etc. lock shall be fitted as per manufacturer specification and as directed by Engineer in charge.
TOTAL OF PART -I-H: Fittings & Fixtures
PART - I-I ~ WATERPROOFING TREATMENT: Notes:- a) The contractor shall get written approval from the Engineer in Charge, for the water proofing agency engaged and shall submit the specification of the waterproofing before commencement of work. b) The contractor shall test the surface where water proofing treatment is provided, for bone dry condition by filling up with water. No wet patches or leaks shall appear on the surrounding wall or under side of the slab. c) The contractor shall furnish guarantee bond on,appropriate stamp paper in the proforma as per Section 10 (iii) of Conditions and Clauses of Contract - 2008 for the entire waterproofing treatment for maintaining the surroundings and under side surfaces of the waterproofing treated area in bone dry condition for 10 years. During the guarantee period the contractor shall attend all leakages, defects etc. if noticed, free of cost, starting the work of checking up and rectification within a weeks time from the date of intimation about such leakages/defects. d) The Contractor shall keep the water tank filled with water after the water proofing work has been completed and shall clean it before handing over. At no time shall the water tank be kept empty. Testing for the bone dry condition for the water proofing work carried out shall again be done, before handing over the flats/building if found necessary by the Engineer in Charge.
Providing and laying integral cement based water proofing treatment of the agency approved by department, including preparation of surface as required for treatment of roofs, terraces etc. mixing with water proofing compound as per IS : 2645 :2003, with average thickness of 115mm and minimum thickness at drain point as 65 mm as per following steps. a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound over the RCC slab including cleaning the surface before treatment. b) Laying cement concrete using broken bricks/brick bats 25mm to 100mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with proprietary water proofing compound over 20mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls up to 300mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary waterproofing compound. d) Finishing the surfaces with 20 mm thick joint less cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with proprietary water proofing compound and finally finishing the surface to receive the China Mosaic waterproofing treatment (to be paid under relevant items). e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order, as directed and specified by the Engineer in Charge.
Extra for additional thickness of brick bat coba over and above standard average thickness of 115 mm for effective slope wherever required.
Filling in bath, W/C, toilet, depressed areas with water proofing brick bat coba of the agency approved by the Dept. at all floors and locations upto the required level and making the surface finished suitable to receive floor finish etc. all complete as per drawings and water proofing agency's specifications & as directed by the Engineer in charge.
Providing cement based waterproofing treatment to the inside surface of water tank by giving injections to concrete bottom slab and walls as required with cement and approved waterproofing compound solution to fill up all inherent holes, voids, honeycombs etc. in concrete and treating the floor and walls with waterproof mortar as per specifications of specialised waterproofing agencies, finishing smooth with trowel in cement colour and testing of water tank by filling up with water as per specifications etc. the thickness of treatment on the floor will be 50mm and on the walls about 20 mm all complete as per drawing, specification and as directed by the Engineer in Charge
Providing china mosaic water proofing over concrete/ plastered surface of horizontal, vertical, sloped/ curved surfaces, rounded vatas, sharp corners, junctions etc., using broken pieces of approved single colour ceramic tile laid over and including 20mm thick cement mortar 1:3 screed mixed with approved waterproofing compound @ 2% by weight of cement, cost of all materials, labour, curing, breaking the tiles to the pieces of required size and shape, laying / fixing the tile pieces to the required line, slope, levels etc., providing extra screed as required for quick & easy flow of water, curing etc., at all heights including necessary scaffolding, cleaning the surface initially with saw dust and finally with acid all as per specifications and,as directed by the Engineer-in-Charge.
TOTAL OF PART -I-I ~ Waterproofing treatment
PART I - J : PLASTERING WORK : Notes :- a) Before commencement of plastering, the area shall be cleaned, wetted and shall be marked with 'Thiyyas' or 'Tapanis' and shall be got approved by the Engineer-in-charge. b) Whenever the electrical contractor/ agency has to fix up switch boxes in walls, necessary Thiyyas or 'Dhadas' shall be arranged prior to plastering so that the electrical boxes are fixed properly in line with the finished plastered surfaces. c) Finishing around the junction boxes shall be done at,all floor, level and position to the line, level and right angles as required while carrying out plastering work. d) No extra claim/cement consumption shall be entertained by the department for the plastering done more than the specified thickness shown in the schedule of quantities, to bring the plastered surface to perfect line, level and plumb with adjoining columns and beams for new and old surfaces.
Cement plaster in single coat with cement mortar at all floors, heights, slopes and locations on plain or curved surfaces including rounding wherever required to prepare the surface even and smooth to correct line, level, plane and plumb including scaffolding, curing etc. complete as per specifications, drawings and as directed by the Engineer in charge.
6mm thick cement plaster in cement mortar (1 cement : 4 fine sand) for exposed concrete surfaces, soffits of slabs and beams, soffit of staircase waist slab etc.
15 mm. thick plaster in cement mortar 1:4 mix for internal brick / concrete surfaces for all walls and beams flush with walls, mullions etc.
Sand faced external/ internal cement plaster as specified below in cement mortar 1:4 at all heights and locations including scaffolding, preparing the surfaces, finishing and rendering with sponge to correct line, level and plumb, curing including making grooves, vatas, plaster fluting (plaster in steps) etc. where ever required complete as per specification and drawings and as directed by the Engineer in Charge.
20 mm thick in two coats for brick/ concrete surfaces (external / internal) (back coat and finishing coat of 10 mm. thick each) with water proofing agent @ 2% by weight of cement.
12mm thick in single coat for independent concrete surfaces.
Extra over plastering items for making and finishing in matching plaster finish (interior & exterior) grooves of following approximate sizes as per drawing in plaster, at all floors and locations to proper line, level and plumb, all as per specifications & drawings and as directed by Engineer in charge.
25 x10mm size
Providing & fixing in position GI chicken wire mesh using necessary "U" hooks, clips or nails using drilling machine etc. at all floors and levels, wherever required to prevent development of cracks in plaster surfaces, as per specifications, drawings and as directed by the Engineer in charge (Only area of chicken mesh provided shall be measured for payment).
Total of Part -I-J : Plastering Work
PART : I-K ~ PAINTING :
Providing and applying 1.5mm thick cement based wall care putty in two coats of M/s. Birla White at all floors and locations, over plastered surfaces, finished smooth to correct line, level, plain, plumb etc., including preparing the surfaces, scaffolding, smoothen the putty surfaces with very fine water proof emery paper to get a glossy finish etc. complete as per specifications, as per manufacturers specifications, drawing & as directed by the Engineer-in-charge.
White washing in three coats in all floors and locations for concrete /wall surfaces in shafts including sand papering and cleaning the surfaces, filling up cracks and crevices if any with approved putty, scaffolding etc. complete all as per specifications and as directed by the Engineer-in-charge.
Painting plastered /concrete surfaces with two coats of acrylic premium (plastic) emulsion paint of M/s Asian or equivalent make & approved colour over a coat of approved cement/acrylic primer (as per manufacturers recommendation) including preparing the surfaces, filling with putty wherever required, scaffolding and cleaning etc, complete as per specifications, drawings and as directed by the Engineer in charge.
Painting plastered/ concrete surfaces with two coats of premium exterior grade acrylic emulsion paint similar to Apex ultima of M/s. Asian Paints or approved manufacturer, of approved colour and shade over a coat of approved exterior grade primer all as per manufacturer's recommendations and as per the approved sample including providing necessary scaffolding, cleaning the surface with water to remove all coating, dust, filling up cracks & crevices with approved putty, curing the surface etc. complete as per specifications and as directed by Engineer in Charge. Note : Both sides of surfaces of jali,if any, shall be measured for payment
Over sand faced plaster and jali etc .
TOTAL OF PART I-K ~ Painting Work
PART : I-L ~ MISCELLANEOUS WORKS Note:- One sample of each item should be submitted for preliminary inspection and approval before procurement/ manufacturing on large scale. After the preliminary inspection and approval, the sample should be fixed at site or kept in the office of the Engineer-in-charge till completion of the work.
Structural steel work at all floors and locations in roofing, guard bars, grills, guard bars for windows, frames, pit / trench covers, cover bracket for slanting chajja , trap door, railing, smoke vents, trusses for dome, M.S grill / fencing, gate, stairs etc. using angles, tees, flats, bars, chequered plates, sheets, channel sections,M.S tubes / pipes, joists, bolts & nuts, etc at all floors and locations, heights, including scaffolding, bracing, multi level stagging, lead etc., including supplying, cutting, fabricating, welding, erecting, making holes/chases wherever required and fixing /embedding in position in concrete/brick work/ marble/granite stone with necessary hold fasts/ stainless steel screws, rawl plugs & anchor fastner of M/s. Hilti, by,drilling etc. and finishing the concrete/ brick work after fixing/embedding complete as per specifications, drawings and as directed by the Engineer in Charge.
Providing and fixing in position at all floors, levels / heights, approved quality machine cut, mirror polished 18mm thick granite stone slab for door/ window frame in two overlapping layers in one piece full length / height of approved shade, finished sizes as directed, moulding and polishing exposed edges in line, level, plumb and fixing the stone with cement mortar 1:3 bedding/ backing closed jointed, machine grouting, cement slurry, curing including cutting of stones to get rounded exposed edges, wastage, final hand polishing, rounding of free exposed stone edges etc. complete as per specifications drawings and as directed by the Engineer in Charge.
Providing and fixing granite stone door and window frame with 18mm thick approved granite stone including providing and fixing 90mm long stainless steel screws (3 Nos. in each vertical stone) with rawl plug by drilling with high frequency power hammer drilling machine and fixing with araldite adhesive and finishing with approved putty with suitable pigment etc. complete. Note: Exposed surface on elevation & exposed vertical finished face shall be measured for payment in SqM. Overlapping & edges shall not be measured.
Providing and fixing Duraboard HD 100 filler board of M/s. Supreme Industries Ltd., 125mm thick and full depth/ width of RCC or as shown in the drawing for expansion joints at all floors and locations in RCC columns, beams, slab, brackets etc. including cutting, laying in position, in line, level and plumb, including the cost of Adhesive(Epoxy or Bitumen or equivalent) for fixing Duraboard to column,beam,slab, etc. as per manufacturer's specifications, including cost of all materials, labour, scaffolding etc. complete all as per specifications, drawings and as directed by the Engineer- in-Charge.
Providing & fixing in position anodised aluminium flats/ angles/ tees/ plates/ sheets/ foils etc. of required size to cover the expansion joint in walls, floors, ceilings and columns etc. including drilling holes, chasing the surface wherever required, fixed with wooden gutties, rawl plugs and C.P brass screws, making good the surface, making slotted holes on aluminium on one side etc., complete.
Providing and applying polysulphide sealing compound of size upto 125mm x 10mm of approved make for the edges of Duraboard including scaffolding, labour, wastage etc. all complete as per manufacturer' s specification and as directed by the Engineer in Charge
Providing and fixing in position following size PVC pipe for Weep holes etc., wherever required in RCC / Masonry walls including cutting to required shape and size, laying the pipeline to proper slope and gradient etc., all as per specifications, drawings and as directed by the Engineer in Charge all complete.
90mm dia PVC-SWR grade B
Providing and fixing 600 mm dia. C.I. frame and cover (conforming to IS: 1726) of size, weight and numbers as specified in schedule of manholes and inspection chambers and rain water grating on terrace, water table etc. including cost of necessary 1:2:4 cement concrete and 1:4 cement mortar for fixing, painting the frame, and cover with two coats of approved paint of approved shade etc. all complete as per drawing, specification and as directed by the Engineer in charge.
Providing and fixing 50mm thick phenotherm board with kraft paper on both sides of M/s. Bakelite Hylam Limited, to the ceiling as thermal insulation at all levels and locations including applying a coat of shalicoat to the under side of the roof and CRPX compound to the underside of each board and pressed to the slab in position, fixing with suitable screws (5 Nos. screws per panel of 1200x600mm) with rawl plug and Stainless steel washers, including sealing the joints with self adhesive brown tape etc. complete all as per manufacturerer's specification, cost of all materials labours, scaffolding, tools & plants, required for completion of the work etc all complete as per drawing and as directed by the Engineer in Charge. (In order to,prevent damage to the waterproofing of roof slab above, the drilling of holes for fixing phenotherm board at ceiling, shall be done prior to carrying out waterproofing works).
Providing & fixing in position suspended false ceiling system using 600mm x 600mm Calcium Silicate tiles (Aerolite)/calcium silicate board(Hilux) having thickness as mensioned below, densified edges and 100% humidity resistance, incombustible as per BS476 part IV with thermal conductivity of 0.043 w/m KC and approved surface design and edge profile (Tegular/ Spintone) placed in a suspended grid of size of 600mm x 600mm made of hot dipped G.I. steel sections having an exposed surface capping of pre-finished baked polyester painted coil wherein the main tee of size 24mm x 38mm x 0.33mm shall be suspended at 1200mm centres along the length of ceiling with 4mm dia G.I wire with necessary level,adjusters and cross tees of size 24mm x 28mm x 0.33mm x 1200mm shall be inserted in to slots between the main tees at 600mm centres and thereafter in direction vertical to the longer tees of size 24mm x 28mm x 0.33 mm x 600mm shall be inserted to form a grid size of 600mm x 600mm resting on the periphery walls on wall angles of size 22mm x 22mm x 300mm x 0.40mm thickness etc. complete as per specifications, drawings and as directed by the Engineer- in- Charge. Note:- The entire grid system shall be designed to bear a distributed load of minimum 15 kg/sqm. Notes for false ceiling i) Surface exposed area of soffit in plan shall only be measured in Sqm for payment and no deduction shall be made for openings for grills, ducts, lighting fixtures, diffusers, cutouts etc. ii) The additional frame works etc. if any for vertical masking and trap door etc. shall be measured in this item without any extra cost. iii) The false ceiling and vertical masking alongwith stepped ceiling if any shall be measured and paid under this item. iv)The rate quoted shall include main tees to be suspended from the ceiling / soffit with the help of metal dash fasteners of Hilti of 6mm x 50mm, soffit cills of 25mm,x 35mm x 1.60mm and 4mm dia G.I wire with galvanised spring steel leveling clips. v) scaffolding required for this works shall be provided by contractor at his own cost. vi) Contractor has to co-operate and co-ordinate with the other agencies working in the area. vii) The rates quoted shall include all frame works around electrical fixtures, A/c ducts, grills / diffusers etc. and no extra payment will be made for the same. No deduction shall be made for opening of individual opening /cut out. viii) Ladder / tripod legs shall be tied with gunny bags or suitable cushioning covers to avoid scratches on finished floors / dado/walls. ix) Epoxy painted walls /finished floors/pvc floors shall be covered with tarpaulins etc. to avoid damage to original finish. x) White washed / distempered / painted walls shall be protected by means of covering plastic etc. to avoid spoiling of the same. xi) Ceramic/marble floor/dado shall be protected suitably to avoid splashing of bitumen etc. xii) All splashing of bitumen, remains of thermal insulation materials etc. shall be cleaned properly. xiii) Damages to the original finishes of the building shall be rectified / redone by the contractor to match the original finish at his own cost.
600 x 600 x 15mm calcium silicate tiles of approved surface design Cosmos with tegular fitted channel with proprietary make exposed grid metal suspension system all as per drawing.
Supplying and fixing in position at all floors and location stainless steel 304 grade mosquito net made out of 24 guage, 16 mesh shutters including fixing on exaust fan frames etc. of various size and shape, fixing with stainless steel nuts and bolts to suit the aluminium frame ( aluminium frame, beading etc. shall be paid under relevant item) including labour, wastage, scaffolding etc. all complete as per drawing, specification and as directed by Engineer in charge.
Supplying, applying and placing swellable type water stop tape of size 19mm x 25mm thick of expansive nature for construction joints of RCC walls of water tank including cleaning the construction joints of loose mortar and dust, applying primer @ as per manufacturer specification, unroll the water bar slowly and carefully on the joint without pulling and stretching it too much after the primer dries a little and became sticky and tying with the reinforcement bars as directed all complete as per manufacturer's specification.
Providing & laying 50mm to 100mm thick approved quality polished Agra Red/ Dholpur sand stone coping over parapet, railing, side walls etc. at all floors & locations including 20mm thick 1:4 (1 Cement : 4 Sand) cement mortar bedding/backing, close jointed & grouted with matching colour readymade cement grout and finished to line, level, curing etc. as required, including cleaning, all as per specification, drawings and as directed by the Engineer in Charge.
Providing, laying & fixing precast interlocking paver blocks of following grade of approved manufacturer, over an existing layer, including loosly filling the joints/open joints transporting to site, placing to proper line & level, etc. including cost of all materials labour, tools etc. complete as per specification, drawing as directed by the Engineer in Charge.
Providing and laying 80mm thick factory made cement concrete interlocking paving blocks of (M-35 grade) made by block making machines with strong vibratory compaction & approved size, shape, design laid in required colour and pattern over and including 150mm thick compacted bed of stone dust/moorum, filling the joints with crushed stone etc. all complete as per the direction of the Engineer-in-charge.
Providing and fixing in position R.C.C precast covers 100mm thick or thickness as specified in drawing for cable pits, shaft covers and other works, of grade 1 : 1.5 : 3 using graded stone aggregate 20mm maximum size including form work, consolidation, finishing with neat cement punning on all surfaces, curing, including providing lifting hooks for trench covers and pit covers and including a thick coat of white wash (or 2 to 3 layers of Tarred paper) to be provided over plastered surface before casting slab as specified in drawing etc. all complete as per specifications, drawing and as directed by the Engineer in charge (excluding cost of reinforcement which shall be paid under relevent item),
Cement plaster 20mm thick for brick work in cement mortar 1:4 at all locations including water proofing agent @ 2% by weight of cement, preparing the surfaces, finishing with neat coat of cement, to correct line, level and plumb, curing etc. as per specifications, drawings and as directed by the Engineer in Charge.
Providing & fixing in position gear type operated by mechanically winding handle, steel rolling shutter of approx. size 3.8m*4.5m conforming to IS 6248 latest consisting of 75mm wide 18G laths inter locked together through their entire length and jointed together at the end by end-locks including all necessary fixtures & fittings and M.S top hood, guide channels, shutter suspension shaft with tested springs, ball bearings, ceiling strips, locking arrangements from inside & outside, crank handles etc. including providing and fixing approved ventillation grill 1500mm height, through out, fixing guides in masonry/ concrete with necessary coach screws nut & bolts with accessories viz MS brackets, etc., painting two coats of,synthetic enamel paint of approved make and colour over a coat of approved steel primer generally as per drawings specifications as directed by the Engineer-in-Charge. Note :- 1) The rate includes providing & fixing ventillation grill of size 1.5mx3.8m or as approved in the middle of rolling shutter. 2) The measurement for rolling shutters will be as per structural opening. Hoods will not be measured separately.
Providing & fixing GI Mesh size (100x100x4mm) IRC-fabric at mid- depth of concrete cover to bottom reinforcement of suspended slab/ beam, wherever there is risk of concrete spalling (for water tank slab). The rate shall include cost of labour, materials, binding wire, cutting, bending, binding, strainghtening, placing in position & for welding with main reinforcement of slab, beam etc. complete as per specifications, drawings and as directed by the Engineer in charge.
Total of PART : I-L ~ MISCELLANEOUS WORKS
Description of Work / Item(s)
Amount
Abstract of Cost for PH Works
Part II-A: Sanitarywares & CP Appurtenances.
Part II-B: Internal Water Supply System
Part II-C: Internal Drainage System
Description of Work / Item(s)
Amount
PART - I :- Public Health Engineering Works Part II-A : Sanitarywares & C.P Appurtenances.
Providing and fixing in position following Vitreous China Wall Hung type Wash down pattern water Closet consisting following items of work:- I) Providing Vitreous China wall hung type wash down pattern Water Closet ( EWC ) conforming to IS 2556 (part XVI) with integral trap outlet having water seal not less than 50 mm, with / without vent and with necessary S.S Anchor supports all complete. ii) Providing thermosetting or thermoplastic Seat & cover for W.C conforming to IS 2548 & fixing as per manufacturer's specification including the cost of corrosion resistant hinges, bolts, nuts, non ferrous or S.S washer etc. all complete. iii) Fixing the Water closet in position, jointing the trap and uPVC pipe using W.C connector (Supreme make) with epoxy grout / Rubber Ring joint as per manufacturer's requirement. NOTE: Supplying, jointing & fixing of W.C connector shall be paid under relevant item. iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps with white / matching cement etc. all complete. v) Testing the system to the full satisfaction of the E.I.C.
White glazed vitreous China EWC as per Hindware cat.No. 20069/20097 lara model with slow falling seat cover or Cera cat no S1041111 cruse model with slow falling seat cover or Parryware cat no Co264 Cardiff model with slow falling seat cover or equivalent model.
Providing and fixing vitreous china Urinal of approved make consisting following items of work: i) Providing urinal of approved make, and placing / fixing it in position as shown in the drawing or as per manufactures specification or as directed including providing M.S brackets, screws etc., finishing the joints with white/matching colour cement all complete ii) Cutting hole, making grove or chases in the wall, reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps with white/matching colour cement etc. all complete as directed by Engineer-in Charge. iii) Testing the system to the full satisfaction of the Engineer in Charge
Vitreous urinal of Starwhite/snow white/bright colour as per Hindware Cat. No. 60010 "Dyna" model or Cera cat. No. S4020113 "Civic" model Or Parryware Cat. No. C0580+C8123 "Whiz" model with connector etc.all complete.
Providing & fixing vitreous China Wash hand basin consisting following items of work:- i) Providing vitreous china wash basin conforming to IS 2556 ( part - IV ) and placing the wash basin in position as shown in the drawing or as directed. ii) Providing a pair of either cast iron built - in cantilever type brackets weighing not less than 1.5 kg / each to be embedded in grade M 15 cement concrete block of size 100 X 75 X 150 mm or cast iron wall fixing cantilever type brackets weighing not less than 1kg / each with screw holes to be fixed to wall using screws, rawl plugs etc. to support the Wash basin, conforming to IS 775 for Wall hung basin.( For wall hung wash basin) iii) Fixing Vitreous China under / over the counter / semi recessed type Wash Basin and placing it in position over the granite platform as shown in the drawing or as directed including finishing the joints with white cement all complete. ( For under/over counter wash basin ) iv) Cutting holes or chases in wall & reinstating to its original condition, painting all metallic parts with two coats of approved flat oil paint over a coat of primer, finishing the gap with white / matching cement etc.all as per specification and as directed for wall hung basin.. v) Installation and testing the entire assembly to the full satisfaction of Engineer- in- charge.
Vitreous China Wash Hand Basin of StarWhite colour of Hindware Make Cat. No. 10096 and Cat. No. 11038 Studio model with pedestal or Cera cat no S2040112 + S 2090120 Concord model equivalent model.
Providing Flushing arrangement to Water Closet etc., including providing and fixing manually operated PVC low level Flushing Cistern consisting following items of work:- i)Providing 10/8/6 ltrs. capacity white colour, SLEEK model PVC low level flushing cistern with all inside syphonic fittings, duly assembled conforming to IS 7231 of approved make with handle, fixing the cistern in position using CP brass screws, rawl plugs, brackets etc.as per the manufacturer's recommendation, making inlet and outlet connections all complete. ii) Providing 32 mm dia.PVC flush pipe upto 1200mm long for low level flush tank for IWC, fixing on the wall using PVC clamps and or concealing in the wall as directed, making connection with W.C pan and flush tank including the cost of PVC fittings, fixtures and jointing materials etc. all complete. iii) Cutting hole, making chases in the wall, floors,slabs etc. and reinstating the surface to the original condition, painting all metallic parts with two coats of flat oil paint of approved make and shade over a coat of primer, finishing the gaps with white/matching cement etc. all complete. iv) Testing the entire system to the full satisfaction of the Engineer in Charge.
Flushing arrangement with low level Dual Flush Cistern of Starwhite/snow white/bright colour as per Hindware "Sleek Essence Dual Flush" model or Cera cat. No. B1020106 "Compass Twin Flush" model Or Parryware Cat. No. E8110 "Slimline Dual Flush Deluxe" model for WC.
Providing Flushing arrangement to Urinal including providing and fixing Sensors / manually operated flush valves consisting following items of work:- i) Providing and fixing flush valve/Sensor in position as per the manufacturer's recommendation, making inlet connections all complete. ii) Providing & laying 20 mm dia.CPVC / 15 mm n.b GI class 'C' Flush Pipe from Flush Valve / Sensor to Urinal, concealed in the wall as directed making connection with Urinal and flush valve / Sensor including the cost of fittings, fixtures, jointing materials etc. all complete. iii) Cutting hole, making chases in the wall, floors, slabs etc. and reinstating the surface to the original condition, painting all metallic parts with two coats of flat oil paint of approved make and shade over a coat of primer, finishing the gaps with white/ matching cement etc. all complete.
Flushing arrangement with concealed flush valve of 'Jaquar Pressmatic' make Cat No.PRS-073.
Providing braided hose with nuts, nipples etc. for Water Inlet connection of following make for wash basin with CP brass check nuts and fixing it in position as directed testing for leak proof joints all complete.including the cost of jointing materials and testing for leak proof joints all complete.
450 mm long Braided Hose of Jaguar Cat. No. ALD - 805B
Providing and fixing approved quality 6 mm thick plate glass mirror of various sizes with 6 mm thick marine ply back including painting the ply wood with two coats of synthetic enamel paint over coat of primer and teak wood moulded frame work of size of 40mm x 20mm alround , polishing the frame with 3 coat of french polish after preparation and making the surface very smooth and final mealamine spray finish, including providing & fixing rawal plug in wall / RCC, drilling screw holes, wooden packing if necessary etc., complete all as ditected by EIC.
Supplying Stainless steel Sink of following size with or without Drain board, approved make, moulded out of 19 SWG (1 mm ) stainless steel sheet of grade AISI 304 (18/8) with waste coupling conforming to IS 13983, placing and fixing the Sink in position to correct line and level with basket type choke-stop strainer ( waste coupling ), Check nuts etc. including the cost of jointing materials, finishing the edges with white / matching colour cement as per manufacturer's recommendation all complete as per specification and as directed by the Engineer-in-charge.
Stainless steel Sink' Nirali -' Elegance' - LARGE with Drain board and with 'Anti-scratch surface' of overall size 1145x510 mm ( Bowl size 560 x 410 x 200 mm )
Providing & fixing in position following type CP fittings/ Fixtures/Faucets of 15 mm nominal dia. with ISI mark/ approved make including providing & fixing specials, wall flanges and fixing to concealed / exposed pipe line with leak proof threaded joints using tephlon tapes, testing the joints hydraulically to a pressure of 10 kg./ sq.cm, rectifying the leaky joints if any, including cleaning etc. complete all as per specifications.
C.P brass 2 Way Bib Cock with wall flange of Jaguar Cat.No. ORP 10041PM.
C.P brass Angular Stop Cock with wall flange of Jaguar Cat. No. ORP 10053PM.
C.P brass single lever basin mixer of 'Jaquar' cat. No. ORP-10011BPM.
C.P Health Faucet with 8 mm dia 1 m long flexible tube & Wall Hook of Jaquar Cat. No. ALD-573
Stainless steel dome shaped heavy quality waste 'coupling of 32 mm size, full threaded, for Urinal.
CP brass click-clack waste 32 mm size full thread with 80 mm height as per Jaquar cat. No. ALD-727 for wash 'basin
CP Bottle trap ( with internal partition) 32 mm size 250 mm & 190 mm long wall connection pipes & wall flange 'for wash basins & Urinal of Jaquar Cat. No. ALD - 769L '250x190.
Sink Cock with Extended Swinging Spout (Wall Mounted Model) with Wall Flange Jaguar cat. FLR-5347ND
Supplying following C.P Brass Bathroom / toilet accessories of following make and fixing on the wall using CP brass screws, rawl plugs etc. as per manufacturer's requirement locations shown and as directed by the E-in-C.all complete at the locations shown and as directed by the E-in-C.
Stainless steel Toilet Paper Roll Holder, recessed type with flap of Jaguar Cat. No.AHS - 1553
CP brass double Coat Hook of Jaguar Cat. No. AKP-35761P.
Liquid soap dispenser Jaquar ACN 1135N
TOTAL OF Part II-A : Sanitarywares & C.P Appurtenances.
Part-II- B : Internal Water Supply System
Supplying & fixing on Exposed surfaces the following sizes uv-stabilized Chlorinated Poly Vinyl Chloride ( CPVC ) pipes & Fittings or ASTM pipes & fittings of specified class having thermal stability for both hot & cold water supply consisting following items of work:- i) Supplying CPVC pipes and CPVC plain / brass threaded fittings, SDR - 11 having thermal stability for hot & cold water supply conforming to IS 15778 or ASTM pipes & fittings with ISI mark / equivalent approvals as per relevant standards. ii) Laying and fixing the pipe and specials on exposed surfaces / underground, to correct line, level and plumb for water supply line, using metal straps ( On wall surfaces ) at 1.00 mtr. interval or as directed by the EIC. iii) Jointing the pipes and Specials using Solvent cement conforming to IS 15225 & Teflon tape ( For threaded joints) of approved makes including cutting the pipe to required size, preperation of surfaces, necessary tools etc. all complete. iv) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. v) Testing the pipe line to a hydraulic pressure as per manufacturers cataglouge for leak proof joint or as per relavant code NOTE:- 1) The rate shall also include for uPVC pipe & specials required for making connections with the existing GI / PP-R/cPVC pipe line laid by other agency. 2) All threaded joints shall be made with brass threaded fittings Only. 3) All consealed cPVC pipes provided for PH work will be measured under this item (Except flush pipes for Urinals & WC) 4)Exposed pipe fixing arrangement include providing & fixing slotted G.I. section & U clamps bolts arrangement for grouping of pipe. Sloted section thickness should not be less than 2mm. Pipes and Fittings SDR-11 as per IS 15778
20 mm n.size
25 mm n.size
32 mm n.size
40 mm n.size
50 mm n.size
Supplying, fixing & concealing on wall / beams / colums etc. the following sizes uv-stabilized Chlorinated Poly Vinyl Chloride ( CPVC ) pipes & Fittings of specified class having thermal stability for both hot & cold water supply consisting following items of work:- i) Supplying CPVC pipes and CPVC plain / brass threaded fittings, SDR - 11 having thermal stability for hot & cold water supply conforming to IS 15778 with ISI mark or equivalent of approved make as per relevant standards. ii) Laying and concealing the pipe and specials for water supply by cutting / making 75 mm X 75 mm grove on the wall, fixing the pipe using metal straps wherever required and filling the grove with cement mortar mixed with water proofing compound, after laying and testing the pipe line including making leak proof joints using cement solvent / Teflon tape ( For threaded fittings) of approved make, cutting the pipe to required length, preperation of surface, necessary tools etc. all complete, iii) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. iv) Testing the pipe line to a hydraulic pressure as per manufacturers cataglouge for leak proof joint or as per relavant code NOTE:- 1) The rate shall also include for cPVC pipe & specials required for making connections with the existing GI / PP-R/PVC/cPVC pipe line laid by other agency. 2) All threaded joints shall be made with brass threaded fittings Only. 3) All concealed cPVC pipes provided for PH work shall be measured under this item (Except flush pipes for Urinals& WC) 4) The scope of work does not cover the Geyser (inlet & outlet) connections. Pipes and Fittings SDR-11 as per IS 15778
15 mm n.size
20 mm n.size
25 mm n.size
32 mm n.size
40 mm n.size
Providing and Fixing Ball valve as per relevant IS of approved make suitable for pipe pressure class, with body of bronze and ball & stem of stainless steel of approved make with fittings and materials for connectivity and labour making water proof joints, including cost of jointing material and cPVC specials if required and testing the joints etc. complete all as per directions of EIC. NOTE: 1) All cPVC ball valves provided for PH work shall be measured under this item 2) All threaded joints shall be made with brass threaded fittings only.
Providing high pressure "HP" following size Float Valve assembly (horizontal plunger type ) conforming to IS 1703 with brass or gun metal piston, back nut and PVC float conforming to IS 9762, fixing to inlet pipe of water tank and making water proof joints including the cost of jointing materials and cPVC Specials, if required, testing the joints as per I.S. recommendations all complete as per specification and as directed.
32 mm dia.
Supplying & fixing following size C.P brass Coupling with approved quality C.P brass Mosquito proof jalli including providing cPVC specials, if required for fixing the coupling, jointing materials such as teflon tape etc. complete as specified & directed for overflow / vent pipe of water tank.
50 mm dia
25 mm dia.
Providing, instaling, fixing, connecting, testing 74 micron Super Flow - Screen filter, of M/s. Jain Irrigation Systems Ltd., of following Model Nos, fitted with pressure gauge, water drain and emptying plug etc all as per specifications, drawings and as directed by EIC.
For 32 mm dia cPVC pipe DJPSF12, Max. working pressure = 10 kg/cm², Flow rate = 12 m³/hr, Inlet/Outlet Connection = 32 mm
Supplying, fabricating and fixing in position structural steel of angle, joists, channel, I Beam, plain / chequered plates for monorail / MS gates / supports of required size including cutting, fabricating, welding, erecting in position including supplying & fixing embedded parts for fixing monorail / supports in concrete, including painting with two coats of approved synthetic enamel paint over a coat of zinc cromate red oxide primer all complete all as per specification and as directed by the Engineer in Charge
Using angle, sloted angles, Joists/ 'I' beam, Channel etc.
Supplying & fixing following Stainless Steel (grade 304) spool pieces of required diameter having flange on one / both sides (Table E) with flange hole, 450 mm or standard available length, providing 3D x 3D and 4 mm thick stainless steel puddle plate (minimum 150mm x 150mm) welded to it where D is the outer diameter of pipe including cutting the plate to required shape and fixing in the reinforcement at the center of RCC wall / slab including cutting the form work provided for concrete at required level, height etc. Complete all as per specifications and as directed by Engineer in charge.
40 mm to 250 mm dia.
Construction of brick masonry valve chambers of following dimensions for depth as mentioned below comprising of 230 mm thick brick masonry in cement mortar 1:4 over a bed of 150 mm thick cement concrete of grade 1:2:4 for foundation with 150 mm offset all round, including racking out joints & plastering in cement mortar 1:3, 20 mm thick both on internal and external surfaces, internal surfaces finished smooth with a floating coat of neat cement, Fixing (FRP/GRP) Frame and cover all as per specifications and directions of the E.I.C. all complete. NOTE: Frame and Cover shall be paid under relevant item
Chamber measuring 0.30 mtr. X 0.30 mtr. for an initial depth of 600 mm (Clear internal dimension)
Providing GRP/FRP composite Mosquito proof hinged cover with frame (Having loading capacity not less than 500 Kg) of 'EVERLAST' having suitable locking arrangement for Manhole opening of water tank, fixing the cover by providing corrosion resistant studs, nuts, built-in hold fasts etc. by chasing or cutting holes and grouting with cement mortar 1:1 by adding approved water proofing compound @ 2% by weight of cement, all complete as per specification and as directed by E.I.C.
600mm dia
TOTAL OF Part II-B : Internal Water Supply System
Part II-C : Internal Drainage system. Supplying and fixing following size uPVC UV-Stabilised soil / waste quality pipes and fittings ( SWR ) for soil, waste, vent, antisyphonege, HVAC waste pipe and rain water pipe lines consisting following items of work:- i) Providing and fixing uPVC UV-Stabilised Soil / waste pipe as per IS:13592 and IS:14735 Grade-B laid in floor & on Exposed faces of wall of Supreme make ii) Fixing the pipeline vertically by Metal clamps with rubber seal of Supreme make Cat. No. SWRMCR 1 to 6. iii) Providing and fixing uPVC cowl at the top of soil, waste water & vent pipe line. iv) Laying the pipe below floor / ground to proper slope and gradient for making connections of soil / waste water pipe line with inspection chamber or Manhole, including the cost of cement mortar, cement concrete, water proofing compound etc. v) Jointing the pipe with Solvent Cement & Rubber ring gasket with making holes in walls / floor grooving and redoing the same and brick support etc. Giving water-tightness test for the pipes laid as per codal provisions. Providing Ring Joint pipes at verticals and solvent cement jointed pipes at consealed locations. vi) Necessary cutting to the required length including short pieces, fittings with & without door, assorted fittings such as plugs, tees, couplers, reducers, cross tees, reducing tees, elbows, bends, cleaning pipe, single & double Y, vent cowl, gaskets, offsets, Tank / WC connectors etc. For Soil & waste and Vent pipe lines
50 mm dia.
75 mm dia.
110 mm dia.
160 mm dia.
Supplying,fixing & concealing on walls / beams / columns etc. the following sizes uPVC Pipes & Fittings of specified class consisting following items of work:- i) Supplying uPVC pipes conforming to IS 4985 and uPVC moulded plain / threaded fittings conforming to IS 7834 for waste water pipe line of SUPREME' make with ISI mark / equivalent approvals as per relevant standards. ii) Laying and concealing the pipe and specials for waste water by cutting / making 75 mm X 75 mm grove on the wall, fixing the pipe using metal straps wherever required and filling the grove with cement mortar mixed with water proofing compound, after laying and testing the pipe line including making leak proof joints using cement solvent / Teflon tape ( For threaded fittings) of approved make, cutting the pipe to required length, preperation of surface, necessary tools etc. all complete. iii) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition.
32 mm dia.
40 mm dia.
Providing uPVC Floor Trap / Nahani Trap of following size having not less than 40 mm effective water seal, fixing the trap in position and connecting with waste water pipe by cement solvent / as per manufacturer's recommandation, embedding the trap in cement concrete 1:2:4 to correct level and gradient, providing and fixing 200 x 200 mm size top tile with central strainer & flat cover / flush strainer, closing the side inletes with plugs if required etc. all complete as per specification and as directed by EIC.
Multifloor trap of 110 x 75 x 50 size of Supreme make Cat No. NSPHMTS04L / NSPHMT005L and 3 pc top,tile & flush strainer, mat finish of Supreme make Cat No. NSPHTT201L/NSPHTT200L.
Providing uPVC cleanouts of following sizes and fixing along the uPVC Waste / soil pipe lines laid below the floor for inspection / choke removal including the cost of jointing materials. NOTE: uPVC specials/ fittings used for fixing the cleanous shall be paid under the relevant item.
Providing HDPE sheet flashing fabricated by welding HDPE flexibal sheet with 160 / 110 mm dia HDPE pipe about 400mm long for PVC rain water pipes, fixing with cement mortar 1:2 mixed with water proofing compound and forming the proper shape and grade and compound and forming the proper shape and grade and finishing with inlet mouth of rain water pipe, cutting RCC slab or wall if required,including the cost of bitumen, cement mortar etc. all complete as specified and as directed by the Engineer-in-charge. NOTE: For fixing HDPE sheet on RCC / Cement Concrete bottom,surface shall be sticked watertite by synthatic glue as per manufacturers recomandation (Glue type as per manufacturers recomandation). Top potion shall be spread with approved synthetic glue and fine 0.5mm sand shall be spinkled over it and allowed to be dried. after drying it is to be embaded using cement morter 1:2 as per required shape and form.
450 x 450 mm size HDPE sheet Flashing fabricated from 8mm HDPE sheet and PN 6 grade 160 mm dia HDPE pipe
Providing and fixing Stainless steel Dome mesh fabricated by welding from 2mm dia 304 grade staainless steel wire for PVC rain water pipes (sheet flashings), with 5mm x 10mm L base ring of 0.5mm thickness 304 grade Stainless steel. L ring to be embaded in waterproofing & dom to be placed on it,including the cost of fixing material etc. all complete as specified and as directed by the E.I.C.
Half Spherical Dome having opening 5 to 10 mm of 160 mm ID
Constructing brick masonry Gully Trap chamber of following size and upto 600 mm initial depth including providing and fixing gully trap, consisting following items of work:- i) Providing square mouth uPVC gully trap of size 150 X 150 mm with 110 mm outlet of Approved Make embedding in position in cement concrete 1:2:4 inside the chamber. ii) 230 mm thick brick masonry in 1:4 cement mortar over 150 mm thick cement concrete 1:2:4. iii) 15 mm thick plaster in cement mortar 1:3 on internal and,external surfaces, internal surfaces and top finished with a floating coat of neat cement. iv) Providing and fixing precast EVERLAST Composite (FRP/GRP) Manhole covers & frame of size 300mm x 300mm as approved by E.I.C having point loading capacity not less than 0.3 tonne approved, including cost of necessary hardware and cement concrete / mortar for fixing the frame.
Construction of 300 X 300 mm size Gully Trap chamber including Providing & fixing Gully Trap with frame & cover all complete. NOTE: Providing & fixing frame & cover including the cost of cement concrete / cement mortar shall be paid under relevant item
Providing & laying UPVC under ground drainage pipes & Fittings of Approved make for storm water drains & Sewer lines of following size conforming to IS:15328 to proper level & grade, jointing including prviding coupler with cement solvent / welded joints / as,per manufacturer's requirement, encasing the pipe alround using cement concrete 1:3:6 complete all as per specifictions, drawing and as directed by the E.I.C. item includes Providing and fixing UPVC fittings such as Bendes, Tees & Y, Reducers, Blanking Plugs, Couplers, Adaptors etc For Sewer line and Storm water Drains
110 mm DN (SN 8kN/m²-SDR34)
160 mm DN (SN 8kN/m²-SDR34)
Constructing brick masonry Inspection chambers of internal sizes 900 X 600mm at bottom and 900 X 450mm at top for an initial depth of 600mm consisting following items of work. i) 230 mm thick brick masonry in cement mortar 1:2 over 150 mm thick bed in cement concrete of grade 1:2:4 with 150 mm offset alround, tapering the longitudinal walls to a height of 450 mm from top of chamber cover to obtain an internal dimension of 900 X 450mm ii) 20 mm thick plaster in cement mortar 1:1 mixed with water proofing compound @ 2% by,weight of cement on internal and external surfaces, internal surfaces and top finished with a floating coat of neat iii) Making benching and haunching in cement concrete of grade 1:2:4 and finishing with floating coat of neat cement. iv) Fixing frame and cover at top using cement concrete of grade 1:2:4 (for bed block / bearing course and capping) and cast iron steps / foot rests, all as per specification and as directed by E-in-C. Making ramp, connecting incoming & outgoing sewers & U-channel (Upto initial depth of 600 mm between the inverts of incoming & outgoing sewers) of height and width not less than the branch pipe dia. in CC 1:2:4, plastering 20 mm thick in CM 1:3, finished smooth with a floating coat of neat cement all complete. NOTE:- Providing & fixing foot-rests / steps and CI / RCC / Composite frame & cover, CC of grade 1:2:4, plastering in C.M 1:2 on exposed surfaces of bed block & capping,making smooth cement finish etc. will be paid under relevant item.
Inspection chamber of internal sizes 900 mm X 600 mm at bottom and 900 mm X 450 mm at top for an initial depth of 600mm. Extra over above item for depth beyond 600 mm
Extra over above item for depth beyond 600 mm initial depth & upto a depth of 1800 mm. all as per specification and as directed.
Construction of circular manhole of 1200 mm internal diameter at bottom and 530 / 560 / 600 mm at top for 1.5m initial depth & brick masonry in 1:2 cement mortar, 230 mm thick wall for 1400 mm measured from top of frame & cover of manhole in conical shape and,remaining height constructed 345 mm thick in cylindrical shape over a 300 mm thick cement concrete bed of grade 1:2:3 with 300 mm offset from outer finished wall surface of the manhole also for benching and fixing frame & cover at top of brick masonry i.e. below and around frame and cover for bed block (bearing course) and capping including providing and fixing frame & cover, CI steps, 20mm thick plaster in 1:1 cement mortar mixed with water proofing compound @2% by weight of cement or as per manufacturer's recommendation on internal and external surfaces, internal surfaces and channel finished smooth with floating coat of neat cement and external surfaces finished rough with wooden float including making ramp, connecting incoming & outgoing sewers & U-channel (Upto initial depth of 600 mm between the inverts of incoming & outgoing sewers) of height and width not less than branch pipe dia. in CC 1:2:4, plastering 20 mm thick in CM 1:3, finished smooth with a floating coat of neat cement all complete. NOTE:- Providing & fixing foot-rests / steps and CI / RCC / Composite frame & cover, CC of grade 1:2:4, plastering in C.M 1:2 on exposed surfaces of bed block & capping, making smooth cement finish etc. will be paid under relevant item.
Top internal dia 530 / 560 mm to suit MD, HD & EHD cover
Extra over above Item for additional depth of Chamber upto 3.0
Making drop connection where difference in inverts of incoming & outgoing sewers exceeds 600 mm including providing and laying following dia. uPVC pipe conforming to IS:15328 & specials, providing and fixing bends, tees, crosses, plugs, caps etc., jointing the pipes/fittings using sealant of approved manufacturer, encasing the pipes with CC 1:3:6 such that shape of the cross section through encased pipe shall be square and sides equal to outer diameter of pipe plus 300mm, including form work, curing etc., all as shown in the drawing, as mentioned in the specifications and as directed by EIC. NOTE:- 1) The depth of drop connection shall be measured vertically from the inverts of the incoming & out going sewers. 2) CC and form work for encasing will be measured and paid under relevant item. 3) Cement concrete, plastering etc. for making connection upto initial depth shall be paid under relevant item. 4) Providing & fixing Cover&frame shall be paid paid under relevant item.
160 mm DN (SN 8kN/m²-SDR34)
Providing & fixing precast EVERLAST Composite Covers / Gratings approved by Competent authority / E.I.C, tested as per IS:1726 including the cost of necessary hardware, 1:2:4 grade concrete for fixing frame, bed block (bearing course) and capping including necessary form work and CM 1:2 mortar for fixing the frame & for plastering exposed surfaces of concrete bed block (bearing course) and capping finished smooth with floating coat of neat cement etc., complete as per specifications, drawings and as directed by the E.I.C.
Rectangular Heavy duty (Grade HD - 20 designation as per IS:1726) frame and cover size 910 x 450mm
Circular Heavy duty (Grade HD-20 Designation as per IS:1726) frame and cover clear internal dia. 530mm
Square Heavy duty (Grade HD - 20 designation as per IS:1726) frame and cover suitable for 300 x 300mm (Clear) valve chambers/Gully trap chambers/drop cleaning chambers etc. NOTE: Shade and Colour and design pattern to be get approved from Engineer-in-Charge.
Providing copolymer polypropylene steel reinforced plastic Foot-rests / Steps of Patel brand or eq. as per ASTM D - 4101 specification and moulded a 12 mm dia. IS - 1786 grade Fe - 415 steel reinforcing bar and in U shape having dimensions 263 x 168 mm and fixing in concrete / wall as shown in the drawing and as directed all complete. Note: All Foot-rests provided for PH work will be measured under this item
TOTAL OF PART- II-C Internal Drainage system.
Description of Work / Item(s)
Amount
Abstract for Part III - ELECTRICAL WORKS
SECTION-I : Main Distribution Board (MDB):
SECTION-II : L.T Cables:
SECTION-III : READYMADE DISTRIBUTION BOARDS
SECTION-IV : Point wiring in PVC (HMS variety) conduits
SECTION-V :Maintenance Free Earthing System
SECTION-VI : Telephone Point Wiring:
SECTION VII: LAN System
SECTION-VIII :Fire Alarm system (FAS)
SECTION-IX :Lightning Protection System :
SECTION-X :Emergency Evacuation/Public Address System (PAS)
SECTION-XI : MISCELLANEOUS ITEMS
SECTION XII : LED Luminaires
Description of Work / Item(s)
Amount
PART III - ELECTRICAL WORKS SECTION-I : Main Distribution Board (MDB): Supply, installation,testing & commissioning of totally type tested front operated front access cubicle, totally enclosed, IP42, indoor type, wall/floor mounted with hinged and lockable doors MDB including interconnections, tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3 phase 4 wire 50 Hz system, and to withstand a fault level of 25KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the top/ bottom/sides as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with,heat shrinkable sleeves & color coaded. SMC/DMC shrouds and busbar supports shall be used. Note: 1) All G.A. & fabrication drawings,single line diagram,control schemes shall be got approved from the E.I.C. Necessary touch up may be done at site, incase if required. 2) All non current carrying metallic parts of the equipment shall be earthed with copper flexible wire / strip of adequate size. 3) All concealed hinged doors and covers shall be provided with suitable flexible earthing connections. 4) Cable entry boxes shall be included in the scope of work. 5) The Booster Pump Starter Panel shall be Post Office Red colour & Ventillation Blower Panel shall be RAL 7035.
Starter Panels for Booster pumps & Ventillation Blower Fans : All the Starter Panels shall be IP 55. Supply installation testing and commissioning of 2 mm MS CRCA sheet starter enclosure with Suitable wall mounted automatic star/delta starter with fuseless backup protection (Type-II co-ordinated as per IS 13947-4-1) for the sizes as mentioned below of main terrace fire pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic & manual operation, etc. complete as required.(Capacity of motor shall be as per IS 12469-1988 considering efficiency of pumps as indicated elsewhere in SOQ Specifications),Note: Each set of Fire Booster Pump panels shall be provided with 1 no. Water level control relay with 3 nos. stainless steel probes similar to M/s Minilec make cat no. WLC D1. The 3 Nos stainless steel probes with required lengths of PVC wires & connectors shall be mounted on underground water tank & the MS supporting arrangement shall be measured seperately under item No. 322.0 of Section-XI:Miscellaneous items. The scope includes providing necessary 240V auxiliary contactors for contact multiplication and adequate terminals to receive signals from water level controllers etc. and control wiring to the respective starters.
REMOTE ON / OFF P.B. STATION Supply, installation, testing and commissioning of readymade ON/OFF push button, ON/OFF indication lamps, in IP42, wall mounting MS CRCA enclosure type, complete with internal wiring with 1.5 sq.mm copper PVC FRLS wires etc Note: 1) PB station shall be lockable type to preven unauthorize operation of booster pump.
TOTAL COST OF MDBs
SECTION-II : L.T Cables: Supply, installation, testing & commissioning of 1.1 KV grade aluminium/ Cu stranded circular/ sector shape core conductor with XLPE insulation, extruded PVC inner sheathed, G.I flat strip/wire armoured, extruded FRLS grade antirodent & anti termite PVC (ST-2)outer sheathed cable conforming to IS : 1554 Part I / IS 7098 Part-I with latest amendments, fixed on wall/column/slab/false ceiling / existing cable tray /existing hume pipe/trench/ shaft/pit/ on 5mm thick M.S. flat /GI spacer/angle/ support fixed with coach screws/grouted in wall/anchor fasteners 2mm. thick G.I. fabricated saddle, all fixing accessories, etc complete including painting of M.S,spacers/angles and saddles or in ground at a depth of 900 mm below ground level , sand bedding, laying of overburnt bricks on side & top-, temporary reinstatement, back filling, dewatering, consolidation, disposal of excess earth within the radius of 500 m and making good to the original finish etc providing Al cable number tag as per enclosed detailed specifications, drawings & as per instructions of the E-I-C & of the following sizes. NOTE: 1) Excavation of earth shall be measured under relevant civil item 2) Sealing of hume pipes with wooden bushes after cable laying shall be included in the scope of work. 3) Clamping of cables on trays including supply of clamping materials as per instruction of EIC shall be included in the scope of work.
4C x 16 Sq.mm Al conductor cable
3C x 4 Sq.mm Cu conductor cable
3C x 2.5 Sq.mm Cu conductor cable
LT Cables End Joints End jointing of following sizes of cable by crimping with supply of all jointing materials like solderless tinned copper cable socket,double compression brass cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of the Engineer-in-charge.
4C x 16 Sq.mm Al conductor cable
3C x 4 Sq.mm Cu conductor cable
3C x 2.5 Sq.mm Cu conductor cable
TOTAL COST OF LT CABLE WORKS
SECTION-III : READYMADE DISTRIBUTION BOARDS Supply, installation, testing & commissioning of following readymade distribution boards, double door, IP 42 degree protection complete with necessary, MCBs, earth leakage circuit breaker (ELCB) etc including interconnections with appropriate capacity size of FRLS insulated copper conductor wires (ISI marked),suitable for concealed mounting /wall mounting with MS frame work of 40 x 40 x 5 mm MS angle iron, with M.S. enclosure fabricated out of M.S. CRCA sheet as per manufacturers standard, with concealed hinged door, locking arrangement etc. including earthing clamps for both incoming &,outgoing circuits, interconnections, per phase isolation kit as required,cable end box & wire way box if required, continuous copper earth wire in the wire way box with single/duplicate brass earthing terminals, danger board, name plate, flexible earthing for the door, metal treatment & powder coated, Phase Distribution drawing etc. all as per drawings (G.A. & fabrication drawing to be got approved), etc. relevant IS & instruction of Engineer-in-charge. Note: 1.MCBs (Type –C/D) shall be minimum 10 KA breaking capacity, as specified. 2. Blanking Plates shall be included in scope of work. 3. DB shall be of standard readymade type as per catalouge No. from approved manufacturers as indicated in preferred makes of material. 4. Routine tests will be conducted at factory as per relevant IS. 5. MCCBs shall be of minimum 25 KA Ics breaking capacity.
LDB, PDB : a) 40 A FP MCB type Isolator - 1 No. b) 6 A -32 A SP MCB -- 18 nos c) 40 A,2 pole ELCB with 30mA sensitivity- 3Nos. d) 8 way brass neutral link -- 4 Sets.
AC TPN DB : 1) 63 A , 4P MCB - 1 No. 2) 63 A DP ELCB with 30mA sensitivity -- 3 nos 3) 6-32 A SP 10kA MCB -18 Nos. 4) 8 way brass neutral link - 4 set
Flexi-DB with acrylic door Security light DB : 1) 16 A DP MCB -- 1 No. 2) 16A,DP, 2 NO Power contactor -- 1 no 3) 25A auxiliary changeover switch --1 No. 4) 6A SP MCB (D-Curve) --5 nos. 5) 8 way brass neutral link -- 2 set
Plug & Socket enclosure (IP 65/66) 415V, 32A FP MCB in weather proof cabinet boxes of IP 65, inlcuding the IP65 cable glanding etc similar to Legrand Plexo boxes catalouge number "6019 96" or equivalent approved.
TOTAL COST OF READYMADE DB WORKS
SECTION-IV : Point wiring in PVC (HMS variety) conduits : Point wiring for light/ceiing fan/6A/ 16A/ socket outlet /6A outlet for exhaust fan, bell point etc. with 1.1 KV grade FRLS PVC insulated multistranded copper conductor wire(ISI marked), in existing floor raceway/ 25 to 40 mm dia High mechanical stress (HMS) rigid PVC/MS conduit having ISI marked IS 9537 Part - 3, including fixing accessories & hardware concealed /exposed in slab/wall or on 5mm. thick G.I. spacers fixed with no. 10 nettle fold wood screws with nylon plug complete with all conduit accessories 0.9 mm G.I. Saddles, ready made MS switchboxes & socket outlet boxes of nominal 1.2 mm thickness , brass earthing stud 1/2 nos, controlling,modular switches, sockets with moulded front plate and inner plate etc. including appropriate size of FRLS PVC insulated copper earth wire , brass/bakelite (straight / angular) lamp holders, 3 plate ceiling rose,6 A, connectors, painting etc. as per specifications and drawings and as per instructions of E-I-C and as detailed below : (sample switch Box etc. to be got approved before fabrication) NOTE: 1. Connections shall be done with crimped type tinned copper lugs & washers. 2. All switches & socket outlets shall be as per preferred makes. 3. All sample boxes with accessories /luminaires shall be got approved from Department. 4. All 16 A socket outlets should be with 6 pin type 5. MS boxes other than switch boxes & socket outlet boxes shall be fabricated out of minimum 1.5mm thick MS sheet duly painted with red oxide primer & 2 coats of epoxy paint. 6. Minimum size of the FRLS insulated copper earth,continuity wire shall be 2.5 sq.mm. 7. The colour shade of switches shall be white /off white. For socket outlet points/switchboards on normal power supply, the cover plate shall be white/off white colour, graphite grey (RAL 7024) or other shade as per instruction of EIC, for socket outlet points/switchboards on DG power supply. 8. The scope also includes supply of modular blanking plates where ever required. 9. The maximum permissible number of FRLS insulated wires through PVC/MS conduits shall be as per technical specifications 10. The point wiring shall generally be concealed type only, except in lift shaft/ Elect. Shaft/ Basement areas/ in RCC retaining wall/ in dry well/ above false ceiling & wherever concealed wiring is not feasible, as per instructions of E.I.C
Primary Light point with 2 nos. 1.5 sq.mm wires & 1 No. 2.5 sqmm earth wire with 6A switch (On nomal & DG power supply)
Secondary light point with 2 nos of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire looped to above item no.306.01 (On nomal & DG power supply)
3 nos.6A/10A/13A multistandard socket points with 2 nos of 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wires, looping with 1.5 sqmm + 2.5 sqmm wires (for earth) & independent 13A,switches. (On nomal & DG power supply)
6A socket with 2 no. of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wires complete with 6 A switch in one box on ceiling height for Exit Lights (On DG power supply)
6A/10A/ 13A multistandard socket with 1 no. of 1.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wires complete with 6 A switch in one box (On nomal & DG power supply)
16 A 6 pin socket outlet point with 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire complete with 16 A switch in one box (On nomal & DG power supply)
6 A + 16 A (6 pin) socket outlet point with 2.5 sq.mm wires alongwith 1 no of 2.5 sq.mm insulated earth wire & looping with 1.5 sqmm + 2.5 sqmm wires complete with independent 6A and 16 A SP switches in one box. (On nomal & DG power supply)
Point wiring for single phase exhaust fan with 1.5 sq.mm phase wires & 2.5 sqmm earth wire & with ceiling rose near exhaust fan & controlling 6 A , 240 V SP switch on nearest switchboard. (On nomal & DG power supply)
Point wiring with 4 sq.mm wire and 2.5 sq.mm insulated earth wire complete with 20 A 3pin socket outlet with plug (Industrial Type) near split AC unit & 20A DP MCB at operating height on wall, socket and MCB both shall be in readymade powder coated MS CRCA box with MS cover and with necessary cutouts, interconnections earthing stud etc . MCB shall be with 10 KA breaking capacity.
Point wiring with 6 sq.mm wire and 4 sq.mm insulated earth wire complete with 32 A 5pin socket outlet with plug (Industrial Type) near AC unit & 32A TP MCB at operating height on wall, socket and MCB both shall be in readymade powder coated MS CRCA box with MS cover and with necessary cutouts, interconnections earthing stud etc . MCB shall be with 10 KA breaking capacity.
Ceiling fan points with 1.5 sq.mm wires and with 2.5 sq.mm insulated earth wire complete with 6A, 240V, SP switch without regulator. (On nomal & DG power supply)
Submain Wiring : Supply, installation testing & commissioning of 1100 V FRLS grade PVC insulated multistranded aluminium conductor wires of the following sizes with necessary leads at both sides in 25 mm/40mm dia PVC(HMS) conduit concealed in wall/beam/ slab/column or on surface of wall/beam/slab/ column on 5 mm thick G.I spacer and 20 SWG GI saddle, MS pull out boxes , junction boxes of suitable sizes as per site requirement, from MDB to individual flat DB including connection with copper lugs etc as per specifications and as per the instruction of Engineer-in-charge. Note: 1. Connections shall be done with crimped type tinned copper lugs. 2. All embeded conduit junction boxes/pull boxes shall be covered by 18 SWG thick M S sheet covers painted white projecting atleast 5 mm around finished opening fixed to box with CSK machine screws.
4 nos. of 6 sq.mm & 1 no of 4 sq mm copper wire in 40 mm dia PVC conduit (HMS variety) with necessary pull outboxes, junction boxes etc including end temination at both the ends with additional loop wire of 0.5 m length at either ends.
4 nos. of 10 sq.mm & 1 no of 6 sq mm copper wire in 40 mm dia PVC conduit (HMS variety) with necessary pull out boxes, junction boxes etc including end temination at both the ends with additional loop wire of 0.5 m length at either ends.
TOTAL COST OF POINT WIRING & SUBMAIN WIRING WORKS
SECTION-V :Maintenance Free Earthing System Supply,installation,testing & commissioning of maintenance free earthing system & associated works, etc. complete as per specifications & instructions of E-I-C. NOTE: 1) Measurement of Earth resistance must be carried out as per instructions of EIC. 2) All type of excavation shall be measured under relevant civil item.
Providing and making earth station comprising of 17 mm dia 3m long earthing electrode of high tensile low carbon steel rod molecularly bonded 250 micron copper coating on the outer surface, UL listed, filling bore with suitable earth enhancement compound as per IEC 62561-7 & manufacturer's standard, surrounding the earth electrode complete with all required materials & instructions of EIC. Note: The scope includes :- 1) Installation of earth rods including making pit/ drilling 150 mm dia, 3m deep bore holes in normal soil/ hard rock as permanufacturer's recommendations & design. 2) Exothermic welding of joints between earth electrode &,GI / tinned Cu strip and between GI / tinned Cu strips, used for interconnection of earth electrodes. 3) Each earth electrode shall be provided with poly plastic inspection chamber with cover as per OEM standard.
Supply & installation of 37x6mm & 150 mm long tinned Cu equipotential bar inside concrete chamber (600 x 600 x 600 mm) as per instructions of EIC. Note: 1) The date of testing and earth resistance value shall be written on the cover with black base with yellow paint. 2) The concrete chamber shall be included in Civil relevent item
Supply & installation of discharge gap device with parallel connected surge voltage protector to couple different earthing system similar to M/S OBO make FS-V20 or equivalent in fibreglass reinforced polyester enclosure IP 65 & IK08 of size 200 (H) x 250 (W) x 115 (D) mm similar to M/s Spelsberg cat no. Abox-i 250. Note: 1) The enclosure housing discharge gap device shall be installed in concrete chamber housing equipotential bar 2) The scope includes interconnection of equipotential bars of lightning & body earthing with suitable size flexible Cu conductor with bimetallic lug at one end as per site & instructions of EIC.,
G.I / tinned Cu earth wire/earth strip fixed on wall/side of trench/slab /column /beam/ shaft connection to panel/DBs/SFU's etc. with 5mm thick G.I. Spacers & 2mm thick G.I. Saddle or in ground at 500 mm below with earth enhancing material surrounding the strip, including excavation in ground, refilling & removal of excess earth within a radius of 500 m, temporary instatement & back filling of trench, consolidation, painting with two coats of black bituminous paint for earth wire/ strip in ground & green enamel paint for earth wire /strip on surface etc.
25 X 6 mm tinned Cu strip
4 SWG tinned Cu earth wire
TOTAL COST OF MAINTENANCE FREE EARTHING WORKS
SECTION-VI : Telephone Point Wiring: Telephone Point Wiring: Point wiring with 4 pair CAT-6 wires copper conductor PVC insulated, in 25-40 mm dia rigid PVC conduit (HMS variety - ISI marked,conforming to IS 9537 Part-III) concealed in slab /wall or surface with 5mm thick G.I.spacer & 20 SWG GI Saddle fixed with nylon plug, wood screws etc. complete with all conduit accessories suitable MS pull boxes of suitable sizes as per site condition wherever required M.S. telephone point accessories boxes fabricated out of min 18 SWG/20 SWG thick CRCA sheet zinc passivated , brass earthing studs 1/ 2 nos., RJ-11 telephone,socket outlets with shutter ferrule numbers on both side of the circuits all terminations with ferrule /lugs if required, labelling all as per drawing specifications & as per instructions of E-I-C. NOTE: 1. Point wiring means 4 pair CAT-6 wires from Telephone Tag Block to assigned point including end termination of one pair at both sides and other pairs should be kept spare. 2. G.A drawings & fabrications drawing are to be got approved from E-I.C.
Point wiring for telephone point with 4 pair CAT-6 wire with RJ 11 jack type socket with shutter in a box with connector
Telephone Tag Block (TTB) : Supply, installation, testing & commissioning of following readymade Krone connector telephone tag block box, 18 SWG MS CRCA sheet, concealed/surface mounted on MS frame of size 40 x 40 x 5mm and grouted on the wall/fixed on the column free standing type with anchor fasterners, cable end/wire way box,if required, with adequate space facility to be provided in the TTB, with front operable hinged door, neoprene rubber/cork gasket for joints, wire bunching clamps , name plate etc. all as per standards, specification, drawing & instructions of E.I.C. Note: 1) Point distribution diagram shall put in side the DB with polythene protective cover. 2) All fabrication drawings shall be got approved. 3) Disconnection module shall be Krone Part No. 69011006-02 or equivalent approved. 4)The scope includes termination of existing telephone cable on the TTB including the glanding etc.
50 pair telephone tag box : A set consisting of : 1. Disconnection module 2 /10 --> 5 nos. 2. Back mounting frame - 2/11 --> 1 nos ( C.T. box with mounting bracket ) 3. Transparent dust cover --> 1 no. complete with all accessories 4. Label Holder - 1 nos.
Telephone cables Supply, installation, testing & commissioning of jelly filled telephone cable with copper conductor, PE insulated, cores twisted, G.I. wire/strip armoured, PVC sheathed cable fixed on wall/ column / slab on 5mm. thick GI spacer/MS flat support fixed with wood screws with 20 SWG GI saddle etc all fixing accessories and as directed by E-I-C.
0.5 mm dia 50 pair Telephone cable
End jointing of Telephone cable with all jointing materials like cable gland, ferrule lugs, ferrule numbers, wire dressing clamps/button tapes, etc. complete including all jointing materials and with necessary special tool kit for KRONE type connector and as directed by E-I-C.
0.5 mm dia 50 pair Telephone cable
TOTAL COST OF TELEPHONE SYSTEM WORKS
SECTION VII: LAN System Supply, instalaltion, testing & commissioning of local area network system comprising of passive components like CAT-6 UTP or improved data cable, information oulet with RJ-45 connections , enclsoures for data outlets with face plates concealed, patch panels, cable managers, LIU, OFC, splicing, 19" mounting racks , power panels in racks , cooling fans in racks, flexible G.I pipe, PVC conduit HMS variety conforming to IS 9537 Part-III etc., complete with labeling/identification on the cable , outlets, patch panels etc. complete in all respect as required as per standards, drawings, specifications and instructions of E-I-C. Note : 1. LAN work shall be done by a specialised agency in the field. Credentials of the agency through which the bidder proposes to execute the LAN work to be submitted post W.O. 2. Evaluation of the proposed agency to execute the LAN work shall be carried out seperately by the Department. 3. Active components i.e switches etc are not in the scope of the agency and shall be executed by the users seperately. Agency shall extend full co-operation to the agency / users executing the balance work which is not in the scope of this tender. 4. Scope includes termination of cables at both ends with all accessories and installation/mounting of 19" racks with all accessories like angle iron frame work etc without any extra cost to the Department. 5. All LAN passive components shall be of same make. 6.The scope includes termination of existing OFC in the LAN rack etc.
Point Wiring :(LAN,Wifi and CCTV points) Point wiring in MS/PVC conduit HMS variety of size 25-40 mm dia ISI mark concealed in slab/column/beam/surface wherever required complete with bends, T/ Cross, junction box with all accessories with RJ-45 shuttered socket outlets (modular) concealed / surface in wall/column/ wherever required with all accessories including label holder, face plate, factory made zinc passivated box, screws etc terminated at one end at patch panel at respective floor at the other end in outlet with an extra loop length of approx 2 m at patch panel, ferrule numbers on both side, all terminations as per standards, drawing, specifications and as per instructions of E-I-C Note : 1. Patch panel shall be measured seperately. 2. Colour of the outlet and facia plate shall be matching with electrical switches and sockets with the approval of E-I-C.
Patch Panels: Supply, installation , testing & commissiong of 24 port, 19" rackmountable patch panel equiped with RJ-45 receptive female, CAT-6 UTP or better compatible to cat-6 cable and cable managers complete as required as per instructions of E-I-C.
LAN Racks:
Supply, installation, testing & commissioning of double section 19" wall mounted pivoting type, 9 U height & 600 mm depth rack having safety glass door & with standard accessories, including power supply panel, fans, cable manager, full cable entry plate with brush at top & bottom etc. complete as required & as per instructions of EIC.
CAT-6 Cable : Supply, installation, testing & commissioning of CAT-6 UTP cable in 25mm dia MS/PVC (HMS variety) conduit on 5mm. thick G.I. spacers fixed with no. 10 nettle fold wood screws with nylon plug complete with all conduit accessories 20 SWG G.I. Saddles etc. for uplinking between patch panels, as required, including termination,including end termination at both ends complete with all accessories all as required & as per instruction of EIC.
OFC Connection accessories in Network Rack : Supply, Erection, termination, testing and commissioning in inside the Wall mount / Floor Rack, following OFC connection accessories comprising of following items with suitable quantity required to complete fibre connectivity : a) 24 port fully loaded LIU - 2 nos. b) SC/LC Single mode OFC pigtails - 4 nos. c) SC to LC Single mode OFC patch chords (3m) - 2 nos. f) Any other accessories required to complete connection.
TOTAL COST OF LAN SYSTEM WORKS
SECTION-VIII :Fire Alarm system (FAS) Design,supply,installation,testing & commissioning of analogue addressable type fire alarm system as per relevant Indian Standard specifications and conforming with relevant specifications of fire authorities of local Municipal Corporation, and as directed by E-I-C and consisting of the following: Note: 1) The work shall be carried out by licensed agency complying local State Fire stautes. 2) Scope includes submission of factory test report of detectors,break glass and hooters and main panel and final inspection at site. 3) Make of all the components of FAS shall be same. 4) The Panel shall be suitable for networking using open technologies such as TCP/IP, Rs 485,modbus. 5) The scope includes the FA panel integration with existing Fire Panels in the Campus with network cable
Multisensor Detectors : Supply ,installation,testing & commissioning of Intelligent addressable smoke detector unit working on multisensor detection technology with optical , heat detector sensor with inbuilt fault isolator complete with base as required & as per instructions of EIC.
Manual Call Point : Supply ,installation,testing & commissioning of dust and vermin proof Addressable Manual Call Point, break glass/pull station (square type/round type suitable for wall mounting surface/concealed) having painted/engraved/ embossed as “IN CASE OF FIRE, BREAK GLASS” on it, small hammer fixed with chain (in,case of break glass), painting and other accessories as required. complete as required & as per instructions of EIC.
Loop powered Sounder with Strobe Light: Supply ,installation,testing & commissioning of Wall Mounting Alarm Intelligent loop powered sounder complete as per specifications and as required & as per instructions of EIC.
Response Indicator : Supply ,installation,testing & commissioning of Response indicator consisting of aluminium casting enclosure & steady glowing 2 nos.red indicator (LED) and cover plate shall be screen printed as "FIRE". The unit shall be suitable for connecting in parallel to the multisensor & wall mounting type with provision of 25mm dia conduit entries ,painting & other materials as complete as per specifications & of E-I-C.
Fire Alarm Panel Design,supply,installation,testing & commissioning of Analogue addressable microprocessor controlled Fire Alarm Control Panels, capable of being IP networked to the,central monitoring System connecting through optical Fiber cable network to monitor and integrate above quantity of accessories like detectors, MCP's/loop power sounder/control modules, Fault Isolation Modules, Loop powered hooters, response indicators, fire/fault indicators, audio-visual signals, central processing units, complete with LED visual indicators, alpha-numeric display and audible alarm both for fire & fault, mains ON indication, test & reset provisions. Each loop should provided with minimum 125 detectors /devices. The panel shall include integral SMF lead acid batteries with sealed cells (max 24 V) with appropriate AH capacity, as per IS requirement with integral battery charger, wire way box , if required , front openable lockable cover with front glass etc. complete as required and as per specification & instructions of EIC. Note: If charger & battery-capacities provided in redymade panel are not meeting operation requirement as per IS 2189 then charger & batteries shall be provided separately including wiring at no extra cost.
4 Loop panel
Supply ,installation,testing & commissioning of 12 relay transponder with surface mounting housing box and interconnection
Wiring for Fire Alarm System : Wiring with 2 nos. 1.5 sqmm FRLS-PVC insulated Shielded twisted pair copper cable/wires in 25mm dia concealed/surface MS/PVC conduit (HMS variety) including cost of cutting and filling chases for concealed conduit/ cost of saddles etc. for surface conduit as required and including the cost of crimped termination’s as required, complete as per instructions of E-I-C.
Surface armoured FA cabling: Supply,installation,testing & commissioning of 2C x 1.5 sqmm shielded twisted pair FRLS-PVC armoured/unarmoured cable (RED Colour) on surface/ above false ceiling including cost of GI spacers, saddles etc.,and including the cost of crimped termination’s as required, complete as per instructions of E-I-C. The cost of mounting base boxes shall be measured sepeartely under miscellaneous item no of electrical section, however the cost of providing cable glands etc. shall be included in the scope of work.
External FA System Cabling : Supply, installation,testing & commissioning of 2C x 2.5 sqmm shielded twisted pair Cu cable with G.I. wire/strip amoured, PVC sheathed cable fixed on wall/ column / slab on 5mm. thick GI spacer/MS flat support fixed with wood screws with 20 SWG GI saddle etc all fixing accessories or in ground (cost of excavation shall be measured under relevant civil item) and as directed by E-I-C.
External FA cable end joint: End jointing of following sizes of cable by crimping with supply of all jointing materials like solderless tinned copper cable socket,double compression brass cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of the Engineer-in-charge.
2Cx2.5sqmm Cu shielded wire
TOTAL COST OF FIRE ALARM SYSTEM WORKS
SECTION-IX :Lightning Protection System :
Supply, installaSupply, installation, testing & commissioning of stainless steel fixing clamp for 0.5 m & 8 mm dia air terminal rod and 8 mm dia roof conductor all as per standard EN 62561-2, complete as required & as per the instructions of Engineer-in-charge. tion, testing & commissioning of stainless
Supply, installation, testing & commissioning of 8 mm dia stainless steel rod for roof & down conductors all as per standard EN 62561-2 fixed on roof/wall/slab/ column etc. as per instructions of EIC. Note: 1) The Roof conductor holder shall be measured seperately under item no. 318.03 & 318.04 2) The down conductor holder shall be measured seperately under item no. 318.03
Supply, installation, testing & commissioning of stainless steel conductor holder for parapet/wall with conductor holder support of 8-10mm, approx 20 mm height & M8 thread all as per standard EN 62561-4 & instructions of EIC.
Supply, installation, testing & commissioning of plastic roof conductor holders for terrace area with conductor holder support rod support of 8 mm, weight 1 kg, concrete block (C35/45) & dimension of 141X86X70 mm all as per standard & instructions of EIC.
Supply, installation, testing & commissioning of stainless steel cross connectors with clamping rod range 8-10mm and material of screw and nut of stainless steel all as per standard EN 62561-1 & instructions of EIC.
Supply, installation, testing & commissioning of stainless steel (V4A) cross connector for connections below ground with clamping flange range of 30/30mm and approx dimension 60X60X3 mm all as per EN 62561-1 standard & instructions of EIC.
Supply, installation, testing & commissioning of Al expansion piece of 8 mm dia and approx. 395mm length including MV SS clamp for roof conductor connection all as per standard EN 62561-2 & instructions of EIC.
Supply, installation, testing & commissioning of stainless steel test clamp suitable for 8-10 mm clamping rod at one end & 30mm clamping flange at other end all as per standard EN 62561-1 & instructions of EIC.
Supply, installation, testing & commissioning of 30 X 3.5 mm stainless steel (V4A) earth strip for ground conductors all as per standard EN 62561-2 in ground as per,instructions of EIC. Note: The excavation of earth shall be measured seperately under civil relevant item.
Supply, installation, testing & commissioning of stainless steel ground conductor holder with conductor holder support flange of 30 X 3.5 mm, height of conductor holder 20 mm, thread of conductor holder M8 & plastic base of ø 8 X 40 mm all as per standard EN 62561-4 & instructions of EIC.
Supply, installation, testing & commissioning of stainless steel conductor connector for earth strip and earth entry rod for 17 mm clamping rod at one end & 30mm clamping flange at other end with distances of screws 40mm all as per standard EN 62561-1 & instructions of EIC.
TOTAL COST OF LIGHTNING PROTECTION SYSTEM
SECTION-X :Emergency Evacuation/Public Address System (PAS) : Supply,installation,testing & commissioning of public Address system as per relevant standards, as directed by E-I-C and consisting of the following: Note: 1) The work shall be carried out by licensed agency complying with local State statutes. 2) Scope includes submission of factory test report of controller,amplifire, speakers call station etc. 3) Scope includes interconnection of various PAS components in 19" cabinet/rack 4) Make of all the components of PAS shall be same. 5) The sysem shall be suitable for networking using open,technologies.
Supply,installation,testing & commissioning of 8 zone digital System Controller complete in 19'' Rack mountable Dual tone, integration with existing Fire alarm system,control for Speech & Music, tone generator & Speech Processor with relays for activating tone & pre-recorded fire alarm messages etc as specified in the Tender Specifications Note: Scope also includes interconnection of existing FA panel with PA controller including testing & commissioning of interface of integrated FA-PA system
Supply, installation, testing & commissioning of 19" racks of the 9 U height, amplifier rack, 800 mm depth, made of 600 mm depth rack having safety glass door & with standard accessories, including power supply panel, fans, cable manager, full cable entry plate with brush at top & bottom etc. complete as required & as per instructions of EIC.
Digital Power Amplifier : Supply ,installation,testing & commissioning of 19''rack mounted class-D Power Amplifier with on board DSP power for local signal processing, Switched mode power supply, Local audio inputs, Mains and battery operation and supervision, complete with following types as specified in the tender specifications and as per instructions of EIC.
2x250 W Power amplifier
Call Station : Basic Call Station with Power 'ON' indication, status/fault indications, priority level of destination is higher than that of the pending announcement indication, Supervision of microphone capsule and with built in On board DSP power for local audio processing. The call station basic can make manual or prerecorded announcements to any pre-assigned zones. The call station shall be provided with 18" gooseneck type microphone. The call station shall be fully supervised and must supports failsafe operation. Even if the network controller fails, the call station shall be able to put through emergency calls and as specified in the tender specifications and as per instructions of EIC.
PA system cabling: Supply ,installation,testing & commissioning of 2 core twin twisted 48/0.2 ATC, multi stranded, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GI spacers, saddles etc. and including the cost of termination’s as required, complete as per instructions of E-I-C. The cost of mounting base boxes & the cost of providing cable glands etc shall be included in the scope of work.
Supply & installation of DVD player with USB support , in-built compressor & limiter as per instruction of EIC.
Supply, installation, testing & commissioning of 3 kVA double conversion (online) rack mountable UPS with single phase input and single phase output configuration with min. 15 minutes battery backup at 100% load using inbuilt sealed maintenance free batteries, flexible chord with plug in existing network rack as per instructions of EIC.
TOTAL COST OF EMERGENCY VOICE EVACUATION SYSTEM (PA) WORKS
SECTION-XI : MISCELLANEOUS ITEMS CABLE TRAYS AND CABLE MANAGEMENT SYSTEM : Supplying and fixing following sizes of GI wire mesh tray, hot dipped galvanised between 60 and 80 microns of zinc as per BS 729 carbon Steel cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required, and duly suspended from the ceiling with electro-zinc coated TF rods, wall mounting brackets etc.
150mm width x 50 mm depth
M. S. Boxes : Fabrication, supply and installation of M.S. supports / boxes as per specification.
MS Fabrication : Supply, fabrication and installation of supports using MS channel/angle / flat/ MS rod hangers etc.including painting with two coats of primer and two coats of epoxy paint of approved shade as per instructions of EIC.
Supply, installation of GI pipe of B class sleeves in beams/column/slab for passing electrical cables/conduit as per instruction of E-I-C.
40 mm dia
60 mm dia
80 mm dia
Blank MS/PVC (HMS) Conduits : Supply & installation of high mechanical stress (HMS) rigid PVC conduit having ISI marked IS 9537 Part - 3, including fixing accessories & hardware concealed /exposed in slab/wall or on 5mm. thick G.I. spacers fixed with no. 10 nettle fold wood screws with nylon plug complete with all conduit accessories 20 SWG G.I. Saddles, MS/PVC pull out boxes, MS/PVC junction boxes, couplers, bends binding wires etc. as per site condition & as per instructions of E-I-C and of following sizes :-
25 mm dia
40 mm dia
Terminal boxes : Supply & erection of min. IP 65, Polycarbonate terminal box for housing 4 Nos terminals (for 2.5 sqmm Cu cable) on epoxy insulator, 3 nos 3A-6A SP MCB (as per load), 1 no.neutral link, 1 no. earth link etc. suitable for mounting on external wall etc. for distributing power to Security light fixtures as per drawing & instructions of E.I.C.
HDPE pipe : Supply, installation, testing & 50/42 mm OD/ID self lubricated HDPE pipes in ground at depth of 750 mm including excavation in all types of soil including hard rock if any cutting of existing footpath,road etc, sand,bedding,laying of warning tape on top,temporary reinstatement.back filling ,dewatering if necessary consolidation,disposal of excess earth with in the radius of 500 m etc. or fixed on wall/column/slab with 5mm thick M.S. flat /GI spacer/angle/ support fixed with coach screws/ grouted in wall/anchor fasteners 2mm thick G.I. fabricated saddle, all fixing accessories, etc complete including painting of M.S spacers/angles all as per the attached work specification and instructions of EIC. Note: 1) The scope of work includes HDPE pipe accessories such as couplers, cable end plugs, cable sealing plugs etc. 2) Excavation of earth shall be measured under relevant civil item.
Insulating Mat : Supply and fixing in position of 'A' class ELASTOMER' insulating mat for protection to operators for working voltages upto 3.3 KV as per IS 15652 - 2006 of size 1000 mm (W) x 2 mm (thickness)
Supply, installation of GI pipe of B class sleeves in beams/column/slab for passing electrical cables/conduit as per instruction of E-I-C.
40 mm dia
60 mm dia
80 mm dia
Supply & fixing of rigid self adhesive photoluminescent AUTOGLO sheet for indoor of different sizes & signage’s as per instruction of EIC.
GI Floor Raceway : Fabricating and installing following size of G.I floor raceways with G.I partion at 100mm, including common G.I cover, earthing with 8 SWG G.I wire and other accessories as required & instructions of E.I.C.
GI Floor Raceway Junction box: Fabricating and installing following size of G.I junction box for floor raceways including G.I cover, as required & instructions of E.I.C.
TOTAL OF MISCELLANEOUS ITEMS
SECTION XII : LED Luminaires : Supply, installation, testing & commissioning of luminaires & fittings,ceiling fans,exhaust fans,etc complete with accessories, tube/lamp etc in on surface of slab/beam by 2 nos (minimum) of 6 mm anchor fasteners or on wall with 2 nos of wood screws, nylon plug etc., suitable supporting frame fixed with rag bolts grouted on the wall/anchor fastener on the beam/on the column & other fixing accessories etc provision & connection with 1.5 sq.mm multistranded copper conductor FRLS PVC wires etc., all as per drawing, specifications & as per the instruction of E.I.C. Note: 1) Sample luminaire/fittings shall be got approved from Dept with complete technical data. 2) The Cat No. is indicative. The equivalent model from list of prefered makes can be considered. 3) All luminairess shall be with drivers. 4) Cost of mounting accessories shall be included in luminaires cost. 5) The lumen output indicated is min. system output of luminaire. 6) The luminaire CCT will be in range of 4000 to 6500 degree K, or as specified, as per instructions of EIC.
Surface mounted LED of min. 1500 Lumen system O/P Square Luminaire Similar to M/s Signify Cat. No. SM200C LED 10S or equivalent approved
LED surface down light luminaire min. 700 lumens system O/P similar to M/s Signify Cat. No. SM250C LED 7S Sleek surface or equivalent approved.
LED Surface Mounted industrial batten min. 2000 Lumen system O/P Luminaire similar to M/s Signify Cat. No. BN308C LED20S or equivalent approved
LED Surface Mounted 4000 Lumen O/P Luminaire,Similar to M/s Signify Cat. No. BN308C LED40S or equivalent approved
Outdoor Lighting
LED color changing IP65 outdoor type min.2000 lumen luminaire for central soft-scape island inside the logo in Miyawaki lake area
Security Light Fixture : Supply, installation, testing & commissioning of wall mounted bracket pole Security lighting fixture consisting of : a) Security light LED fixture IP 66, min 3500 lumens system output, similar to M/s Signify cat no. BRP046 LED 36S or equivalent approved. Scope also includes internal wiring with 2.5 sq.mm copper conductor PVC wires from terminal box to fixture in the PVC rigid pipe & earthing - 1 set b) External terminal box of fibreglass reinforced polyester enclosure IP 65 & IK08 of size 140 (H) x 140 (W) x 79 (D) mm complete with DIN rail, terminal block (suitable for 6 sqmm Al cable). The fibreglass enclosure shall be similar to M/s Spelsberg cat no. Abox-i 100. c) Mounting arrangement of above fixture with suitable 38 mm NB G.I pipe medium variety to IS 1239, 1000-1600 mm long bend to shape and fixed to wall with 5 mm thick GI spacers and 25 mm wide and 18 SWG thick GI saddle etc as per instruction of E-I-C. Mounting arrangement to be got approved from E-I-C.
Supply & erection of 7 to 12W Bollard fixture, 800-1000 mm high, min.IP 65, IK 05, 2700-4000 degree K CCT, with PCC block of 200 x 200 x 200 mm for mounting on ground, anchor fastners, 2 nos 40/33 mm HDPE pipes in PCC block for passage of loop in & out cables,including IP66 Junction box with min. 4 nos. knockouts for cable loop in loop out with IP65 cable glands of required cable size etc. earthing etc. complete as required similar to M/S Signify make cat no: BCP150 LED /WW 6S PSU 'LED Bollard' or eq. approved as per instructions of E-I-C.
Emergency Luminaire : LED egress surface/recess, maintained type luminaire,(double side viewing) in corridor near staircase with 1 hour backup similar to PEL LED E/M of M/s Prolite with all required hardware, egress symbols etc as per instructions of EIC.
Exhaust fans: Supply, installation, testing & commissioning of 200/225 mm dia size of cassette type exhaust fans, single phase complete with blades, motor, scope includes supply of 3C copper 1.5 sq.mm. flexible chord of suitable length upto ceiling rose near exhaust fan with louvers with bird screen rag and fixing arrangement in window/wall as per instructions of EIC.
Ceiling Fans : Supply, installation, testing & comissioning of following Brushless DC (BLDC) ceiling fans with double ball bearing with following length downrod, canopies, shackles, blades with safety cable suspension (Secondary support safety cable) white colour with all accessories including continous earthing and final connection with 24/0.2 mm dia copper conductor 2/3 core twisted PVC flexible wire etc. Note: BLDC Fan should be as per technical specifications & testing conforming to IS 374/79 with latest amendments all as per specifications & instructions of E-I-C.
1200 mm sweep with GI down rod of varying lenghts from min 260 mm to 1000 mm as per location & instructions of E-I-C.
Fan Hook Boxes Supply, installation, testing of concealed fan hook boxes of size 150 x 150 x 75 mm deep fabricated out of 2mm thick M.S CRCA sheet with 12.5 mm dia M.S tested rod hook with brass earthing stud & welded nut from inside and 2mm thick round M.S cover plate overlapping by 15 mm, including red oxide and two coats of white synthetic enamel paints and brass chromium plated screws and cup washers for fixing and all as per conceptional drawing No.: CED/EM /STD/11 R4 & instruction of Engineer-in-charge (Sample box with cover to be got approved before fabrication including the fabricator)
TOTAL OF LIGHT FIXTURES, CEILING FANS ETC. WORKS
Description of Work / Item(s)
Amount
Abstract of Cost for HVAC Works
Part IV:-HVAC Works
Description of Work / Item(s)
Amount
Part IV :- HVAC Works AC Units
Supply, installation, testing and commisioning (SITC) of Hi wall all-weather Split Type inverter AC with minimum 1.5 TR nominal cooling capacity along with heating arrangement suitable for 230 V, 50 Hz, single phase AC supply consisting of tubular blower, fan motor, DX cooling coil, filter,ABS fire retardant as body material for indoor unit, control and power panel , supports etc, on/ off timer with advance startup, high capacity compressor, cordless remote control, air purging using vaccum pump, charging the system with R-410A / CFC free Refrigerant as per installation manual for smooth operation of AC’s, complete in all respects as per technical specifications and as instructed by Engineer-In- charge.
Supply, installation, testing and commisioning (SITC) of Hi wall all-weather Split Type inverter AC with minimum 2.0 TR nominal cooling capacity along with heating arrangement suitable for 230 V, 50 Hz, single phase AC supply consisting of tubular blower, fan motor, DX cooling coil, filter,ABS fire retardant as body material for indoor unit, control and power panel , supports etc, on/ off timer with advance startup, high capacity compressor, cordless remote control, air purging using vaccum pump, charging the system with R-410A / CFC free Refrigerant as per installation manual for smooth operation of AC’s, complete in all respects as per technical specifications and as instructed by Engineer-In- charge.
Refrigerant Piping with Rubber Nitrile insulation (Combined Gas line & Liquid line) Supply, installation, testing and commissioning of Interconnecting refrigerant copper piping ( suction & discharge line) duly insulated with tubular elastomeric nitrile rubber of required thickness and shall be wrapped with aluminium threaded tape/ monsoon tape from outdoor unit to indoor unit with necessary fittings, valve, flare nuts/ brass fittings etc as per technical specification and as approved by Engineer In Charge. All outdoor refrigerant pipeline shall be provided with appropriate mechanical protection for preventing damage by birds and the horizontal pipelines if any shall be laid over MS hot dip galvanised tray, complete in all respects as per technical specifications and as instructed by Engineer-In-charge. NB: 1) All piping inside the room shall be properly supported with MS hanger & clamps. 2) Size (i.e. dia. & thickness) of copper pipes & thickness of tubular elastomeric nitrile rubber insulation should be as per manufacturer's recommendation.
Drain piping duly insulated Supply, installation and commissioning of rigid/ flexible HD PVC piping/ GI piping duly insulated with closed cell elastomeric nitrile rubber insulation complete with fittings, accessories, supports on wall/ ceiling or floor etc. as per site situation & all as per technical specification and as approved by Engineer In Charge. Note: 1) Size (i.e. dia. & thickness) of drain pipes & thickness of tubular elastomeric nitrile rubber insulation should be as per manufacturer's recommendation. 2) All drain piping inside the room shall be properly supported with hanger & clamps, complete in all respects technical specifications and as instructed by Engineer-In-charge.
Cabling Supply & laying of 3C X 4 sqmm. cu power cabling along with required control cabling and adequate earthing as per site requirement with adequate size of cu conductor wire with saddles & spacers to connect outdoor units with respective indoor units & power cable to connect power outlet to ODU/ IDU complete with end connections as required, complete in all respects as per technical specifications and as instructed by Engineer-In-charge.
PVC Trunking Supply & laying of casing and caping(PVC trunking 100 mm X 50 mm) for enclosing refrigerant tubing with insulation, drain line and electrical cable as per site situation, complete in all respects as per technical specifications and as instructed by Engineer-In-charge.
M.S. Structure Fabrication of various M.S structure (namely M.S. stands for the ODUs of A/C units, expansion tank, any other item not covered in respective items wherein supports are not included shall be part of this item) as required & fabricated out of M.S. flat of size (50 mm x 6 mm) and M.S. angle of size (50 mm x 50 mm x 6 mm) and safety guard of M.S. flat of size (12 mm x 12 mm) with opening in safety guard for maintenance purpose of Split AC's ODU unit, painting with two coats of synthetic enamel over one coat of red oxide primer of approved make & shade on all M.S. structure as required and complete in all respects as per technical specifications and as instructed by Engineer-In-charge.
Centrifugal Fans
Supply Fans (1 W + 1 S) Supply, Installation, Testing and Commissioning of SISW Centrifugal Fan of capacity 10000 CFM at 65 mm static along with SS bird screen, flexible metallic canvas connections, drive arrangement including required foundations and all accessories, high efficiency TEFC Motor & Starter, control wiring, power cable terminations etc. as per drawings, technical specifications & instructions of Engineer-in-charge.
Exhaust Fans (1 W + 1 S) Supply, Installation, Testing and Commissioning of SISW Centrifugal Fan of capacity 10000 CFM at 80 mm static along with SS bird screen, flexible metallic canvas connections, drive arrangement including required foundations and all accessories, high efficiency TEFC Motor & Starter, control wiring, power cable terminations etc. as per drawings, technical specifications & instructions of Engineer-in-charge.
GI Ducting Design, supply, fabrication, installation, testing and commissioning of GI ducting of following sizes for supply from and exhaust to ventilation fans and all complete with turning vanes, access doors, supports etc. as per drawing and specifications and instructions of Engineer In Charge.
Diffusers Supply, installation, testing and commissioning of powder coated aluminum air diffusers with volume control dampers complete in all respects as technical specifications, drawings and as instructed by Engineer-In-Charge.
Aluminium Cladding: Supplying and wrapping of 26 Guage Aluminium cladding for refrigerant piping as per technical specifications and instructions of Engineer-in-Charge.
JYOTI SARUP MITTAL
Anurag Enterprises
Anurag Enterprises
JYOTI SARUP MITTAL
JYOTI SARUP MITTAL
Anurag Enterprises
Anurag Enterprises
Anurag Enterprises
Anurag Enterprises
Anurag Enterprises
Anurag Enterprises
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid