Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.7 LAdmitted-Finance | -1.10% | ₹1.7 L | L1 | Admitted-Finance |
Tender Value
₹1.7 L
EMD Value
₹3,400
Closing Date
12 Aug 2026, 6:00 pmClosed
EXECUTIVE ENGINEER
XEN PWD ELECT DIV ALWAR
Providing and fixing electric material for emergent repair work at Govt SK and MCH Hospital, Sikar
2026_CEPWD_583374_2
721 NIT 11/2026-27 EE PWD ELECT DIV ALWAR
Open Tender
Electrical Works
Percentage
60 days
SIKAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
MD RISL / XEN PWD ELECT DIV ALWAR
₹3,400
Yes
XEN PWD ELECT DIV ALWAR
19 Aug 2026
6 Aug 2026
13 Aug 2026
6 Aug 2026
12 Aug 2026
6 Aug 2026
10 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization catagory, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 25sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. | - | - | - | - |
| 2 | Four pole Isolator | - | - | - | - |
| 3 | 80 A/100 A rating | 2 | Each | - | - |
| 4 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. | - | - | - | - |
| 5 | Single pole MCB (With B / C curve tripping characteristics) | - | - | - | - |
| 6 | 6 A to 32 A rating | 15 | Each | - | - |
| 7 | Four pole MCB (With B / C curve tripping characteristics) | - | - | - | - |
| 8 | 50/63 A rating | 2 | Each | - | - |
| 9 | 40 A rating | 4 | Each | - | - |
| 10 | Double pole MCB (With B / C curve tripping characteristics) | - | - | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
Tendernotice_2.pdf
PDF • 1.78 MB
Tendernotice_3.pdf
PDF • 6.19 MB
BOQ_1036278.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .