| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC NARAN PALLY PURBO BARDHAMAN PIN 713 101 | PURBA BARDHAMAN | WEST BENGAL | 713101 | L1 | Accepted-AOC Quoting Lowest rate | |
| 2 | L2₹11.7 L+₹50,510 (4.49%)Rejected-Finance | L2 | Rejected-Finance Quoting Higher Rate | |
| 3 | L3₹12.4 L+₹1.2 L (10.6%)Rejected-Finance | L3 | Rejected-Finance Quoting Higher Rate |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
18 Jan 2018, 3:00 pmClosed
Superintending Engineer,Western El.Circle,PWD
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Administrative approval and sanction of fund towards revamping an augmentation of existing outdoor type sub-station to indoor type sub-station at ITI Durgapur,Dist-Burdwan (west)....Supply Installation testing commissioning of substation-Supply an
2018_WBPWD_147985_1
WBPWD/SEWEC/AED /NIQ-59/2017-18
Open Tender
ELECTRICAL WORKS ORG
Item Rate
Durgapur
Please refer Tender documents.
4 documents required · 4 mandatory
₹30,000
Yes
25 Jun 2020
10 Jan 2018
20 Jan 2018
10 Jan 2018
18 Jan 2018
10 Jan 2018
Amount
S/Laying 1.1 kv grade 4 core 185 sq.mm XLPE/PVC insulated and sheathed, armoured cable with Al.conductor (Havells/Polycab/Glowstar/ NICCO) in following manner as per GS
a)Through existing Mansonary Trench
b)Through existing G.I pipe / kiosk box
c)Through UG trench
d)Through wall at an average depth of 4 inch
e)Through wall with saddle
S/Laying 1.1 kv grade 4 core 95 sq.mm XLPE/PVC insulated and sheathed, armoured cable with Al.conductor (Havel/Polycab/Glowstar/ NICCO) in following manner as per GS
a)Through existing Mansonary Trench
b)Through existing G.I pipe
c)Through UG trench
d)Through wall at an average depth of 4 inch
e)Through wall with saddle
f) Through along the length of pole
S/Laying 1.1 kv grade 4 core 50 sq.mm XLPE/PVC insulated and sheathed, armoured cable with Al.conductor (Havells/Polycab/Glowstar) in following manner as per GS
a)Through existing Mansonary Trench
b)Through existing G.I pipe
c)Through UG trench
d)Through wall at an average depth of 4 inch
e)Through wall with saddle
S/Laying 1.1 kv grade 4 core 35 sq.mm XLPE/PVC insulated and sheathed, armoured cable with Al.conductor (Havells/Polycab/Glowstar) in following manner as per GS
a)Through existing Mansonary Trench
b)Through existing G.I pipe
c)Through UG trench
d)Through wall at an average depth of 4 inch
e)Through wall with saddle
S/Laying 1.1 kv grade 4 core 25 sq.mm XLPE/PVC insulated and sheathed, armoured cable with Al.conductor (Havells/Polycab/Glowstar) in following manner as per GS
a)Through existing Mansonary Trench
b)Through existing G.I pipe / kiosk box
c)Through UG trench
d)Through wall at an average depth of 4 inch
e)Through wall with saddle
S/F 50 mm dia GI pipe (ISI medium) as per GS
S/F 80 mm dia GI pipe (ISI medium) as per GS
S/Laying 1.1 kv grade 4 core 16 sq.mm XLPE/PVC insulated and sheathed, armoured cable with Al.conductor (Havells/Polycab/Glowstar) in following manner as per GS
a)Through wall at an average depth of 4 inch
b)Through wall with saddle
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE armoured cables and finishing the end of the following cable by crimping method as to G.S.
a) 4 core x185 sq mm
b) 4 core x 95 sq mm
c) 4 core x 50 sq mm
d) 4 core x 35 sq mm
e) 4 core x 25 sq mm
f) 4 core x16 sq mm
Re-straining upto 6/1/.166 ACSR conductor including S&F binding wire with 9 SWG soft Al wire as to G.S.
Re-straining 8 SWG to 6 SWG GI continious earth wire without earth clamp as to G.S
Replacing Galv. (hot dip) MS earth clamp 380x25x3mm size complete with bolts & nuts etc. as required on pole (as per specification) for fastening earth wire inlc. Painting
Replacing stay wire with 7/8 SWG G.I(hot dip) stranded wire (45 ton)incl.S & F G.I thimble & making of binding at both ends
Supplying & Erection of Galv. ‘D’ iron complete with suitable pole clamp 100mmx114mm porcelain shackle insulator & 19 mm dia Galv. bolts & nuts. incl. painting
Dismalting of OH line comprising ACSR conductor cross arms/irons clamps/brackets/v-brackets insulators earth wire cadle guard safety devices incl. Sorting out rolling the conductors stacking loading at sites and delivering,unloading,measuring the conducter,sorting,stacking property any places as per direction upto a lead of 1.6 km
OH lines comprising of 3ph,neutral,street light phase and earth wire
Supply & erection of 6/1/2.11mm to 6/1/3.35mm all Al. conductor steel reinforced(ACSR) incl. S & F 6 SWG dead soft Al. binding wire & jumpering etc. carriage conductor upto 1.6Km from stotre to site of work
Supplying & fixing "Hexagonal type" safety device with 4 SWG hard drawn all Al. Conductor for upto 6 conductors incl. earth wire in vertical disposition
Supplying and Erection of Galv. Stay set complete with 7/12 SWG GI (Hot Dip) Stranded stay wire (45 ton quality), 1.8 mtr.x 16 mm dia Galv. stay rod 100 mmx100 mm x6 mm thick Galv. MS anchor plate, 356 mmx13 mm dia Galv. bow (with ratchet type nut), thimble, Galv. Box type Stay Clamp in CC foundation (6:3:1) having hard jhama metal incl. providing earth connection
Supplying & Erection of No. 6 SWG GI (Hot Dip) continuous earth wire with Galv. (Hot Dip) earth clamp
Supplying and fixing 415V, 315A TPN SFU ( Make L & T /Siemens/ABB) open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
Supplying and fixing 415V, 160A TPN SFU ( Make L & T /Siemens/ABB ) open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
Supplying and fixing 415V, 125A TPN SFU ( Make L & T /Siemens/ABB ) with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
Supply, Installation , testing & Commissioning of floor-cum-wall mounted Industrial type panel board fabricated by (50 x 50 x 6 mm)MS angle and 50 x 6 mm MS flat incl. 2 nos hole for earthing attachment and necy painting as per direction of E.I.C and S & F of the following.An Autocad drawing of the Panel should must be approved by EIC before manufacturing the panel. Incoming 415 V 415 Amp. TPN main switch HRC type fuse( Make: L &T/Siemens/ ABB) -01 no Bus Bar Chamber 415 Volts B.B.C made of CRC sheet incl. 4 Nos. 800 Amp capacity 4 x (80x10) mm electrolytic tinned cu bars on non hygroscopic porcelain insulator of requisite length incl. drill hole etc. as required and interconnection by suitable copper wire from incoming main switch to starter as approved by E.I.C- 01 item
out going a) 415 Volt 125 Amp SFU TPN main switch with DIN type HRC fuse on LS&NL( make L & T / Siemens / ABB) - 04 no’s b) 415 Volt 100 Amp SFU TPN main switch with DIN type HRC fuse on LS&NL(make L & T / Siemens / ABB)- 03 no’s c) 415 Volt 63 Amp SFU TPN main switch with DIN type HRC fuse on LS&NL(make L & T / Siemens / ABB)- 03 no’s d) 240 Volt 32 Amp DP—do—do—do-- (make Havells/HPL)-01no e) S & F 3 phase 4 wire 5 A Multifunctioning LCD meter having features to measue V, A, F, PF, KW, KWH, phase sequence etc. ( Make : L & T / Siemens/ ABB) f) CT 500A/5A.....3 No g) sliding fuse with 5A HRC fuse –3nos h)LED type indicating lamp—3 nos incl. interconnection i)Danger notice board --1 no
Earthing with 50 mm dia(ISI medium) GI pipe in morrum soil as per GS
Excavation of morrum soil for installation of earth electrode and filling & ramming
M S CITY ELECTRICAL CO
M/S KALIMATA ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .