Tender Value
₹43.3 L
EMD Value
₹86,700
Closing Date
9 Jul 2026, 10:30 am
Similar tender results from the same govt authority in the past 3 years.
Provision of CCTV Cameras for Escalators at MYS, DVG and Lifts at, HAS, ASK, DRU, RRB, SMET, KRNR, TTR & SBHR Stations of Mysuru Division
08-SNT-MYS-2026-03
08-SNT-MYS-2026-03
Open
6 Months
Mysuru, Karnataka
₹0
₹86,700
17 Jun 2026
17 Jun 2026
25 Jun 2026
A-SWR-SOR 2025 Items
Supply and Fixing of PVC casing and capping/Pvc pipe of minimum 25 mm size or higher as per requirement at site on the wall/floor etc., using bends, coupler and T joints and flexible pipe wherever necessary with fixture in the OFC room from equipment rack to common termination and from OFC room to SM room/Reservation office /Data logger/FO|S room etc. (All required material for fixing to be arranged by the contractor Above/
Supply of STP CAT 6 cable as per latest specification. Above/
Supply of 12 Core single mode outdoor armoured optical fiber cable as per latest specification. Above/
Supply of power cable copper PVC insulated flexible 3-core multi strand 2.5 sqmm as per latest specification No.IS:694:1990 Above/
Supply, installation, termination and testing of Rack/Wall mountable FDMS and termination IN and OUT 24 fiber OFC cables (with all connecting materials) routing/dressing fiber as per direction of engineer/In charge. this work includes termination/splicing of fibers and testing of fibers in the section/block and report of fiber to be submitted in hard and soft copy. Above/
Supply of RJ 45 connector suitable for STP/UTP cable. Above/
Supply and fixing of OFC patch cards 5 Mtrs length as per site requirements. (LS-SC, SC-SC, LC-LC, FC-FC patch cards as per site requirement) Above/
Supply of CAT-6 Patch Cord-5mtrs length.
B-Non-SOR Items
Supply & Installation of 9U Rack (depth of Rack around 600 mm+/- 10mm) with 01 hinge door cooling fan, 5 Socket power extension board, cable manager, partition tray and accessories with locking arrangement on both door and wall mount arrangement. Make: Comrack, Rittel, APW, President, HCL, D-link or similar.
Supply, Installation and Commissioning of Layer 2 Switch as per 02 RDSO/SPN/TC/65/2021, Rev.6.0 orlatest. Minimum 8+2 Port Manageable with 8 Nos 10/100/1000 Mbps Ethernet port, POE+ & Single Fiber 2 Nos 1G SFP Port with BX SM SFP Optical Modules loaded. with all accessories etc. As per RDSO/SPN/TC/65/2021, Rev.6.0 or latest. with all accessories and detailed speceification enclosed along with a standard/reputed make.
Supply and Installation of ACDB for AC Distribution Box along with required MCBs, Lock and Key arrangement and ISI Mark MCBs of Various Rating as per site requirement.
Supply, Fixing and Termination of dual I/O boxwith RJ45 socket . Dual information outlet with surface mount box (SMB),RJ45 socket faceplate with shutter facility to be suppliedand fixed. UTP cable shouldbe terminated in I/O box.
Laying of UTP cat 6 cable , 6 fiber OFC cable in PVC casing / pipe/Cable tray /trough as per the instructions of in charge at site."
Supply Installation, Testing & Commissioning of Full HD Fixed Dome type IP Colour 06 Camera along with 128 GB or Higher SD Card, Housing & Mount and all accessories required for installation purposes as per RDSO Spec No RDSO/SPN/TC/65/2021,Rev 6.0 or latest. Inspection RDSO along with a standard/reputed make.
Supply Installation, Testing & Commissioning of Full HD Fixed Bullet type IP Colour 07 Camera along with 128 GB or Higher SD Card, housing and mount and all accessories required for installation purposes per RDSO Spec No RDSO/SPN/TC/65/2021,Rev 6.0 or latest.Inspection RDSO along with a standard/reputed make.
Supply Installation, Testing and Commissioning of Software for VMS and Video 08 Recording software. (Per camera Licence means Video Management and Video Recording at multiple locations such as Station, RPF Post & DC Server room covered by the same license) as per technical spec and functional requirement as per RDSO Spec No RDSO/SPN/TC/65/2021 Rev.6 or latest.
Integration of the Camera as well as different make/model of a VSS server (located at a different station controlling 03 cameras) with ICCC server (Intellve ICCC) located at MYS Mysuru) station
Supply and fixing of 25 sizes of mediam class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCforWorks-2022.pdf
ATTACHMENT
GCCforWorksCorrectionSlipsACS1-10.pdf
ATTACHMENT
ACS-112026forGCC2022-compressed.pdf
ATTACHMENT
SpecialTechnicalConditions-STQC.pdf
ATTACHMENT
HQ_CorrectdisplayofdateandtimeinCCTVsystemsprovidedatstation_12.02.2026.pdf Guidelines for
ATTACHMENT
TechnicalGuidelines-TTP.pdf
ATTACHMENT
2024-04-24-RDSOLetter-CCTVTAN-Signed.pdf
ATTACHMENT
RevisionofconservancyCessCharges-07.09.2021.pdf
ATTACHMENT
Proforma17-Localcontentlessthan10crores.pdf
ATTACHMENT
AnnexuresforWorksTenders.pdf
ATTACHMENT
TenderBooklet-CCTVatEscalatorsLift.pdf
ATTACHMENT
HQ_CorrectdisplayofdateandtimeinCCTVsystemsprovidedatstation_12.02.2026.pdf
ATTACHMENT
TechnicalSpecifications-CCTVforEscalatorsandLift.pdf
ATTACHMENT
Download all tender documents and submit your bid