| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹19.7 L+₹3.1 L (18.3%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹20.2 L+₹3.5 L (20.9%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹20.0 L
EMD Value
₹39,960
Closing Date
26 Sept 2022, 6:00 pmClosed
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
REPAIR/ MAINT AND DAY TO DAY MISC ELECT WORKS AT MH AREA AND AMC UNITS UNDER GE (EAST) JALANDHAR CANTT
2022_MES_542011_2
GE/JULL/ET-37/2022-23
Open Tender
Civil Works
Item Rate
335 days
Jalandhar Cantt
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹39,960
Yes
22 Nov 2022
6 Sept 2022
4 Oct 2022
6 Sept 2022
26 Sept 2022
14 Sept 2022
Amount
Attending complaints for unserviceable light fittings of (any size/ type/ capacity), building security light, ceiling/ Exhaust fan of any size /capacity including carrying out minor repairs such as changing of small pieces of wires, tightening of loosen electric connections, nuts, bolts screws, or switches, switch board, electronic ballast, tube rods, bipin holders, ceiling rose, MCBs, PVC conduit or casing capping, disconnecting and dismantling of ceiling/ exhaust fan, hanging and connecting of ceiling fan etc as required to make the item functional during 0900 Hrs to 1700 Hrs by deploying one electrician alongwith with one helper (having mobile phone) including necessary T&P complete all as specified and directed. Notes: (a) Replacement of electrical fittings (items) shall be measured and paid for separately under respective items (b) Attending and repairing up to 02 points at a time in each building shall be considered as one complaint. (c) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly. (d) In case of failure on the part of contractor for attending complaints a penalty shall be imposed @ Rs.200/- per complaints per day and recovered from his dues. (e) Replacement of switch, ceiling rose, MCB shall be measured and paid separately (f) Contractor shall be responsible for maintaining the record of complaints on complaint slips and complaint record register and complaint slips and register will be provided by the contractor which shall be handed over to department. (g) Attendance register of electrician and helper shall be maintained by the department and penalty for absent @ Rs. 500/- per person per day shall be recovered from contractor's due. (h) Contractor shall ensure that the deployed electrician and helper will carry functional and live mobile phone while on duty and will be on contact with JE/ Engineer-in-Charge.
Supply and fixing in repairs Constant current LED driver suitable for surface/recess mounted LED panel 2 ft x 2 ft, 36/40 watt including taking down existing driver complete all as specified and directed
Supply and fixing in repairs Constant current LED driver suitable for surface/recess mounted LED panel upto 25 watt including taking down existing driver complete all as specified and directed
Supply and fixing in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified and directed.
Supply and fixing in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, two way complete all as specified and directed.
Supply and fixing switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified and directed.
Supply and fixing in replacement socket out let 5 Amp, 5 pin flush type complete all as specified and directed.
Material and labour in replacement socket outlet multipurpose 2 in 1, 6 pin, 5 & 15 Amps, flush type complete all as specified and directed.
Material and labour bell push switch flush type 5 Amps, SP, 240 volts complete all as specified and directed.
Material and labour in replacement lamp holder insulated body with back plate suitable for batten fittings complete all as specified and directed.
Supply and fixing in replacement ceiling rose surface type bakelite 65 x 50mm three terminal complete all as specified and directed.
Supply and fixing in replacement electronic step type 5 speed ceiling fan regulator, single phase, 1 module complete all as specified and directed.
Supply and fixing in replacement electronic step type 5 speed ceiling fan regulator, single phase, 2 module complete all as specified and directed.
Material and labour in replacement bell electric AC (Ding Dong) 240 volts SP complete all as specified and directed.
Supply and fixing in replacement white modular switch 1 way 6 Amp, 250 volt 1 module complete all as specified and directed.
Supply and fixing in replacement white modular switch two way 6 Amp, 250 volt 1 module complete all as specified and directed.
Supply and fixing in replacement white modular switch 1 way 16 Amp, 250 volt 1 module complete all as specified and directed.
Supply and fixing in replacement white modular bell push switch 6 Amp, 250 volt 1 module complete all as specified and directed.
Supply and fixing in replacement white modular socket 6 Amp, 250 V AC 2 in1 socket with shutter combined two module complete all as specified and directed.
Supply and fixing in replacement white modular socket 6/16 Amp, 250 V AC twin socket combined two module complete all as specified and directed.
Supply and fixing in replacement white modular fan regulator , 250 V AC step type 5 steps two module complete all as specified and directed.
Supply and fixing in replacement white modular blanking plate one module complete all as specified and directed.
Supply and fixing in replacement MCB SP 6 Amps to 32 Amps, 240V with rupturing capacity 10 KA, B-Curve complete all as specified and directed.
Supply and fixing in replacement MCB SPN 6 Amp to 32 Amps, 240V with rupturing capacity 10 KA, B-Curve complete all as specified and directed.
Supply and fixing in replacement MCB SPN 40 Amps, 240V with rupturing capacity 10 KA, B-Curve complete all as specified and directed.
Supply and fixing in replacement 415V, 10KA, B-Curve miniature circuit breaker (MCB) of triple poles and current carrying capacity 32Amps in the DB complete all as specified and directed.
Supply and fixing in replacement 415V, 10KA, B-Curve miniature circuit breaker (MCB) of triple poles neutral and current carrying capacity 32Amps in the DB complete all as specified and directed.
Supply and fixing in replacement 415V, 10KA, B-Curve miniature circuit breaker (MCB) of triple poles neutral and current carrying capacity 63Amps in the DB complete all as specified and directed.
Supply and fixing in replacement isolator DP 40 Amps, 240V complete all as specified and directed.
Supply and fixing in replacement isolator FP 40 Amps, 415V complete all as specified and directed.
Supply and fixing in replacement isolator FP 63 Amps, 415V complete all as specified and directed.
Supply and fixing in repair in existing DB/panel MCCB 63 Amps to 120 Amps 3 pole 16 KA with extended terminals, phase separators with spacers including taking down existing MCCB complete all as specified and directed.
Supply and fixing in repairs fan capacitor 2.5/ 3.15 MFD including taking down existing complete all as specified and directed.
Supply and fixing in repairs rubber real for ceiling fan including nut & bolt and side clamps including taking down existing rubber real complete all as specified and directed.
Supply and fixing in repairs flexible cord of size 1 sqmm two core including taking down existing cable complete all as specified and directed.
Supply and fixing in repairs flexible cord of size 0.75 sqmm two core including taking down existing cable complete all as specified and directed.
Supply and fixing in repairs flexible cord of size 1.5 sqmm three core including taking down existing cable complete all as specified and directed.
Supply and fixing in repairs flexible cord of size 2.5 sqmm three core including taking down existing cable complete all as specified and directed.
Supply and fixing in repairs copper wire FRLS PVC insulated unsheathed 1.5 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing in repairs copper wire FRLS PVC insulated unsheathed 2.5 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing in repairs copper wire FRLS PVC insulated unsheathed 4.0 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing in repairs copper wire FRLS PVC insulated unsheathed 6.0 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing in repairs copper wire FRLS PVC insulated unsheathed 10.0 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing in repairs copper wire FRLS PVC insulated unsheathed 16.0 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing in repairs copper wire FRLS PVC insulated unsheathed 25.0 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing in repairs copper wire FRLS PVC insulated unsheathed 35.0 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing in repairs copper wire FRLS PVC insulated unsheathed 50.0 Sqmm single core multi stranded complete including taking down existing wire all as specified and directed.
Supply and fixing in repairs copper thimbles pin/ bottle type for copper cables single core 1.5 Sqmm to 2.5 Sqmm complete all as specified and directed.
Supply and fixing in repairs copper thimbles pin/ bottle type for copper cables single core 4.0 Sqmm to 10.0 Sqmm complete all as specified and directed.
Supply and fixing in repairs copper thimbles pin/ bottle type for copper cables single core 16.0 Sqmm to 25.0 Sqmm complete all as specified and directed.
Supply and fixing in repairs of metal clad industrial plug 20 Amps, 250 V, 2 pole with earth and metal top plug suitable for geyser/ AC complete all as specified & directed. Make : Standard/ Havells/ L&T/ Hagar
Supply and fixing in repairs metal flush mounting box of 1 or 2 module complete all as specified and directed.
Supply and fixing in repairs metal flush mounting box of 3 or 4 module complete all as specified and directed.
Supply and fixing in repairs metal flush mounting box of 6 or 8 module complete all as specified and directed.
Supply and fixing in repairs metal flush mounting box of 12 module complete all as specified and directed.
Supply and fixing in repairs plastic surface mounting box of 1 or 2 module complete all as specified and directed.
Supply and fixing in repairs plastic surface mounting box of 3 or 4 module complete all as specified and directed.
Supply and fixing in repairs plastic surface mounting box of 6 or 8 module complete all as specified and directed.
Supply and fixing in repairs plastic surface mounting box of 12 module complete all as specified and directed.
Supply and fixing in replacement modular cover plate (WHITE) with frame 1 or 2 module complete all as specified and directed.
Supply and fixing in replacement modular cover plate (WHITE) with frame 3 or 4 module complete all as specified and directed.
Supply and fixing in replacement modular cover plate (WHITE) with frame 6 or 8 module complete all as specified and directed.
Supply and fixing in replacement modular cover plate (WHITE) with frame 12 module complete all as specified and directed.
Supply and fixing in repairs B-22 energy saving LED bulb 12 watt, 230V, 6500K complete all as specified and directed.
Supply and fixing in repairs energy saving ultra bright LED polycarbonate tubelight 20W suited for installation in existing T8 fitting with G13 lamp holders, operative on 140-270 volts AC, complete all as specified and directed.
Supply and fixing in repairs LED universal batten box type suitable for LED tube rod 22/20 watt, complete all as specified and directed.
Supply and fixing in replacement wall mounted LED light fitting 4', 20W, lumen efficacy > 120 lumen/watt (min), THD<15%, power factor>0.95 in extruded aluminium housing with polycarbonate diffuser and integrated electronic driver with short circuit and surge protection complete all as specified and directed.
Supply and fixing in replacement wall mounted LED light fitting 2', 10W, lumen efficacy > 120 lumen/watt (min), THD<15%, power factor>0.95 in extruded aluminium housing with polycarbonate diffuser and integrated electronic driver with short circuit and surge protection complete all as specified and directed.
Supply and fixing in replacement energy saving recess mounting LED luminaire, suitable for false ceiling of size 60cm x 60xm with CRCA housing, 34/36W, IP-20, lumen efficacy > 120 lumen/watt (min), THD<10%, power factor>0.95 with high efficiency LED electronic driver with short circuit and surge protection, operative on 140-270V, AC supply, complete all as specified and directed
Supply and fixing in replacement energy saving surface mounting LED luminaire of size 60cm x 60xm with CRCA housing, 34/36W, IP-20, lumen efficacy > 120 lumen/watt (min), THD<10%, power factor>0.95 with high efficiency LED electronic driver with short circuit and surge protection, operative on 140-270V, AC supply, complete all as specified and directed
Supply and fixing in replacement energy saving surface mounting bulk head luminaire with polycarbonate diffuser LED integral fitting 10W (min), IP-54, complete all as specified and directed.
Supply and fixing in replacement energy saving 45W, lumen efficacy 110 lumen/ watt LED, IP-66, IK07 bldg security lights with high efficiency electronic CVCC potted driver, having surge protection min 10KV, power factor>0.95 complete operative on AC supply 140-270V pre-wired and qty including suitable size mounting bracket with clamps duly painted complete all as specified and directed
Supply and fixing in replacement LED flood lights for building, IP-66, THD<10%, power factor>0.90, Hi-power LED with lens, pressure die-cast aluminium housing complete with all accessories of 50W LED, lumen efficacy 110Lm/Watt, with secondary optics modular independent lenses provided with SPD 10KV for better distribution of light complete all as specified and directed
Supply and fixing LED post top light for 360 degree indirect light with polycarbonate diffuser and IP-65 protection, 25 watt, 230V, 50 Hz complete all as specified and directed
Supply and fixing in replacement sheet metal enclosure for DBs when MCBs to be used, SPN 12 ways 240 V, with copper bus bar, double door, epoxy coated inside and outside with neutral and earth connection bar prewired complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for DBs when MCBs to be used, SPN 8 ways 240 V, with copper bus bar, double door, epoxy coated inside and outside with neutral and earth connection bar prewired complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for DBs when MCBs to be used, SPN 4 ways 240 V, with copper bus bar, double door, epoxy coated inside and outside with neutral and earth connection bar prewired complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for DBs when MCBs to be used, SPN 2 ways 240 V, with copper bus bar, double door, epoxy coated inside and outside with neutral and earth connection bar prewired complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for DBs when MCBs to be used, TPN 4 ways 415 V, with 200 Amps rated bus bar, double door, epoxy coated inside and outside with neutral and earth connection bar prewired complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure for DBs when MCBs to be used, TPN 8 ways 415 V, with 200 Amps rated bus bar, double door, epoxy coated inside and outside with neutral and earth connection bar prewired complete all as specified and directed.
Supply and fixing in replacement distribution board iron clad vertical type, double door with IP-43 IK -09 Protection suitable for MCCB TP as incomer and MCB SP/ TP as outgoing 415 volts 3 phase 50 C/s 4 way , complete with appropriate size copper bus bar and neutral and earth link complete with one MCCB TP 415 volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as specified and directed. Note : Rates of MCCB and MCBs are deemed to be included in quoted rate.
Supply and fixing in repairs/replacement distribution board iron clad, vertical type double door with IP-43 IK -09 Protection suitable for MCCB TP as incomer and MCB SP as outgoing 415 volts 3 phase 50 C/s 8 way , complete with appropriate size copper bus bar and neutral and earth link complete with one MCCB TP 415 volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as specified and directed. Note : Rates of MCCB and MCBs are deemed to be included in quoted rate
Taking down existing unserviceable exhaust fan from site, supply and fixing new exhaust fan 300mm sweep, metal body complete all as specified and directed
Supply and fixing in replacement rod for hanging ceiling fan 45 cm long including 02 Nos nuts bolts and washers with lock pins complete all as specified and directed.
Supply and fixing in replacement rod for hanging ceiling fan 60 cm long including 02 Nos nuts bolts and washers with lock pins complete all as specified and directed.
Taking down existing unserviceable wall fan from site, supply and fixing new wall fan 450mm sweep complete all as specified and directed
Material and labour in replacement for earthing complete with & including copper earth plate of size 600 x 600 x 3.15mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with lop edge of earth plate not less than 1.5 below ground level connected to copper earth wire 20x3mm dia connected soldered and riveted to earth plate by means of nuts, bolts , check nuts & washers of galvanized iron or steel all as Shown in electrical plate No. 3 of MES Schedule (Part- I) and connected to panel board, all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe upto 7.5 meter from electrode to earth terminal point feeder pillar box including provision of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate GI light grade watering pipe of 20mm dia with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC (1:3:6) type C-1 as in earth chamber, 50mm thick RCC cover using cement concrete 1:2:4 type B-0 reinforced with & including 8mm dia mild steel TMT bar @ 100mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified & shown on drawings & directed. Notes: - (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Material and labour in replacement for earthing complete with & including galvanized MS earth plate of size 600 x 600 x 6mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with lop edge of earth plate not less than 1.5 below ground level connected to galvanized earth wire 4mm dia connected soldered and riveted to earth plate by means of nuts, bolts , check nuts & washers of galvanized iron or steel all as Shown in electrical plate No. 3 of MES Schedule (Part- I) and connected to panel board, all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe upto 7.5 meter from electrode to test point and aluminium strip 25 x 3.15mm from test point to equipment including provision of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate GI light grade watering pipe of 20mm dia with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC (1:3:6) type C-1 as in earth chamber, 50mm thick RCC cover using cement concrete 1:2:4 type B-0 reinforced with & including 8mm dia mild steel TMT bar @ 100mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified & shown on drawings & directed. Notes: - (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Material and labour in repair earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Supply and fixing in repairs PVC conduit medium grade 20mm dia ISI marked including saddles/ clamps and junction boxs including taking down existing conduit complete all as specified and directed.
Supply and fixing in repairs PVC conduit medium grade 25mm dia ISI marked including saddles/ clamps and junction boxs including taking down existing conduit complete all as specified and directed.
Supply and fixing in repairs PVC conduit medium grade 32mm dia ISI marked including saddles/ clamps and junction boxs including taking down existing conduit complete all as specified and directed.
Supply and fixing in repairs PVC casing caping 20/12mm ISI marked including taking down existing conduit complete all as specified and directed.
Supply and fixing in repairs PVC casing caping 25/16mm ISI marked including taking down existing conduit complete all as specified and directed.
Supply and fixing in repairs PVC casing caping 32/16mm ISI marked including taking down existing conduit complete all as specified and directed.
Material and labour cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sun shades, shelves, lintels etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting n.exc 10cm girth in brick walls complete all as specified and directed.
Taking down existing unserviceable ceiling fan from site, supply and fixing new ceiling fan 1400mm sweep, BLDC 5 star complete all as specified and directed
Supply and fixing in repairs white hylum sheet of switch board of any size duly cutting for no of switches/ sockets complete all as specified and directed.
Supply and fixing in repairs white round PVC junction/ fan box cover 4-6" dia including taking down existing complete all as specified and directed.
Supply and fixing in repairs Plug top 6A 3 Pin Plug 220 Volt complete including taking down existing plug top all as specified and directed.
Supply and fixing in repairs Plug top 16A 3 Pin Plug 220 Volt complete including taking down existing plug top all as specified and directed.
Dismantling of ceiling fan upto 1200/1400mm sweep of any make/ model/ sweep, removing the burnt out winding wires, rewinding with copper winding wire of superior quality and insulation materials overhauling/ servicing, greasing/ lubricating, insulating electric leads, replacing cotter pins, bearing/ bushes, bolts nuts, capacitor, assembling back checking for proper function, refixing the same with PVC insulated flexible copper wire and testing all as specified and directed
Dismantling of exhaust fan upto 250-300mm sweep of any make/ model/ sweep, removing the burnt out winding wires, rewinding with copper winding wire of superior quality and insulation materials overhauling/ servicing, greasing/ lubricating, insulating electric leads, replacing cotter pins, bearing/ bushes, bolts nuts, capacitor, assembling back checking for proper function, refixing the same with PVC insulated flexible copper wire and testing all as specified and directed
Dismantling of exhaust fan upto 380-450mm sweep of any make/ model/ sweep, removing the burnt out winding wires, rewinding with copper winding wire of superior quality and insulation materials overhauling/ servicing, greasing/ lubricating, insulating electric leads, replacing cotter pins, bearing/ bushes, bolts nuts, capacitor, assembling back checking for proper function, refixing the same with PVC insulated flexible copper wire and testing all as specified and directed
Material and labour for painting of ceiling fans/ exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed
Material and labour in replacement exhaust fan louver suitable for upto 450mm sweep exhaust fan complete all as specified and directed
Dismantling of ceiling fans/ exhaust of any make/ model/ sweep, overhauling/ servicing, greasing/ lubricating, insulating electric leads, replacing cotter pins, bearing/ bushes, bolts nuts, condenser, assembling back checking for proper function, refixing the same with PVC insulated flexible copper wire and testing all as specified and directed.
Material and labour for rectification of loose/ hanging lightening conductor aluminium strip/ GI strip in hospital building including fixing of insulators, saddles and screws as required complete all as specified and directed Note : The cost of insulators, saddles and screws are deemed to be included in the quoted rate
Material and labour for rectification of loose/ hanging PVC conduit including fixing of saddles and screws as required complete all as specified and directed Note : The cost of saddles and screws are deemed to be included in the quoted rate
Material and labour for rectification of loose/ hanging armoured cable of any size including fixing of saddles and screws as required complete all as specified and directed Note : The cost of saddles and screws are deemed to be included in the quoted rate
Supply, laying, testing and commissioning in replacement of service wire PVC insulated, electric cables, (heavy duty) 1100 volts grade with aluminium conductor of size 2.5 Sqmm 2 Core complete all as specified and directed
All as per Srl Item No. 111.00 above here-in-before but 4.0 Sqmm 2 Core
All as per Srl Item No. 111.00 above here-in-before but 6.0 Sqmm 2 Core
All as per Srl Item No. 111.00 above here-in-before but 10.0 Sqmm 2 Core
Taking down existing unserviceable storage water heater and supply and fixing electric water heater, storage type steel body with steel inner tank and heating element upto 2KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostat, connection piece etc all as specified and directed
Taking down existing unserviceable storage water heater and supply and fixing electric water heater, storage type steel body with steel inner tank and heating element upto 2KW capacity 50 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostat, connection piece etc all as specified and directed. Make for Srl item No. 115.00 & 116.00 : VENUS/ HAVELLS/ RACOLD/ CROMPTON/ BAJAJ/ USHA
Taking down carefully existing point wiring of any type (i.e. on wooden batten, surface conduit, casing capping or concealed conduit) complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets wooden batten, conduit etc including accessories such as wooden gutties/ rawl plug, screw etc including removing materials from site and making good disturbed surface of walls, floors etc. complete all as specified and directed.
Material and labour for point wiring for one light/ fan/ bell point controlled by one switch SP one way with 1.5 Sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit , medium grade, ISI marked 20mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc including cutting chases in wall for laying of conduit and making good to all disturbed surfaces and matching the same with adjoining specifications, sunk type pressed steel terminal switch box as specified in SSR Part-1 with 3mm thick plastic laminated sheet top cover fixed with nickel polished brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed.
All as per srl item No. 118.00 above but for one socket outlet 5 Amps on independent board.
All as per srl item No. 118.00 above but for one socket outlet 5 Amps on same board with other switches.
All as per srl item No. 118.00 here in before but with 2.5 Sqmm (nominal area) FRLS cable for one 3 pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed.
Material and labour for point wiring for one light/ fan/ bell point controlled by one switch SP one way with 1.5 Sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through existing surface/ concealed conduit and accessories and terminated in modular metal box and including 1.5 Sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed.
All as per srl item No. 122.00 above but for one socket outlet 5 Amps on same board with other switches.
All as per srl item No. 122.00 above but for one socket outlet 5 Amps on independent board.
All as per srl item No. 122.00 above but with 2.5 Sqmm copper (nominal area) FRLS cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm with stranded copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed.
Material and labour for point wiring for one light/ fan/ bell point controlled by one switch SP one way with 1.5 Sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through existing surface/ concealed conduit and accessories and terminated in and including new sunk type pressed steel terminal switch boxes as specified in SSR Part-1 with plastic laminated bakelite sheet top cover 3mm thick fixed with nickel polished brass screws with washers and including 1.5 Sqmm stranded copper conductor PVC insulated FRLS cable green in colour as continuous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed.
All as per srl item No. 126.00 above but for one socket outlet 5 Amps on same board with other switches.
All as per srl item No. 126.00 above but for one socket outlet 5 Amps on independent board.
All as per srl item No. 126.00 above but with 2.5 Sqmm copper (nominal area) FRLS cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm with stranded copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed.
Material and labour in replacement submain wiring with PVC insulated cable copper conductor FRLS two single core 2.5 Sqmm drawn through in and inlcuding PVC rigid non metallic surface conduit (medium grade) with all fittings including earth continuity FRLS copper conductor 2.5 Sqmm PVC insulated with green insulation including taking down existing unserviceable/ burnt submain all as specified and directed. Note : Two runs of cable 2.5 Sqmm, one run of cable 2.5 Sqmm and one Run of PVC conduit will be measured as one unit RM.
Material and labour in replacement submain wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through in and inlcuding PVC rigid non metallic surface conduit (medium grade) with all fittings including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation including taking down existing unserviceable/ burnt submain all as specified and directed. Note : Two runs of cable 4 Sqmm, one run of cable 4 Sqmm and one Run of PVC conduit will be measured as one unit RM.
Material and labour in replacement submain wiring with PVC insulated cable copper conductor FRLS two single core 6 Sqmm drawn through in and inlcuding PVC rigid non metallic surface conduit (medium grade) with all fittings including earth continuity FRLS copper conductor 6 Sqmm PVC insulated with green insulation including taking down existing unserviceable/ burnt submain all as specified and directed. Note : Two runs of cable 6 Sqmm, one run of cable 6 Sqmm and one Run of PVC conduit will be measured as one unit RM.
Material and labour in replacement submain wiring with PVC insulated cable copper conductor FRLS two single core 10 Sqmm drawn through in and inlcuding PVC rigid non metallic surface conduit (medium grade) with all fittings including earth continuity FRLS copper conductor 10 Sqmm PVC insulated with green insulation including taking down existing unserviceable/ burnt submain all as specified and directed. Note : Two runs of cable 10 Sqmm, one run of cable 10 Sqmm and one Run of PVC conduit will be measured as one unit RM.
Material and labour in replacement submain wiring with PVC insulated cable copper conductor FRLS two single core 16 Sqmm drawn through in and inlcuding PVC rigid non metallic surface conduit (medium grade) with all fittings including earth continuity FRLS copper conductor 16 Sqmm PVC insulated with green insulation including taking down existing unserviceable/ burnt submain all as specified and directed. Note : Two runs of cable 16 Sqmm, one run of cable 16 Sqmm and one Run of PVC conduit will be measured as one unit RM.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .