Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC QUOTED RATE LOWEST AND REASONABLE. |
| 2 | L2₹1.1 Cr+₹1.6 L (1.44%)Rejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹1.1 Cr+₹1.6 L (1.44%) | L2 | Rejected-Finance QUOTED RATE NOT LOWEST. |
| 3 | L3₹1.2 Cr+₹8.2 L (7.32%)Rejected-Finance | ₹1.2 Cr+₹8.2 L (7.32%) | L3 | Rejected-Finance QUOTED RATE NOT LOWEST. |
| 4 | Rejected-Technical BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | - | - | Rejected-Technical As per Technical Evaluation report |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
12 Nov 2024, 6:00 pmClosed
CWE KOLKATA
Headquarter Commander Works Engineers Military Engineer Services No1 National Library Avenue Alipore Kolkata700 027
SPECIAL REPAIR TO BLDG NO P-29 AT COMD HOSP (EC) UNDER GE(A) KOLKATA
2024_MES_678543_1
8357/E-14/24-25
Open Tender
Civil Works
Item Rate
270 days
GE ALIPORE KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
GE ALIPORE kOLKATA
₹2.1 L
Yes
23 Jan 2025
8 Oct 2024
19 Nov 2024
8 Oct 2024
12 Nov 2024
29 Oct 2024
9 Oct 2024 - 15 Oct 2024
Amount
NOTES :The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed by Engineer-in-Charge.
M & L brick work with old size fly ash brick straight or curved on plan exc. 6m mean radius, built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M & L for brick work with fly ash bricks old size, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition)
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal and flat) rough finished surface complete in all respect as spd by the Engr-in-Charge.
M&L for Reinforced cement concrete nominal mix using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
S&F TMT bars 10mm dia (Fe-500d) and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.
M&L for Rendering 20 mm thick in two layers (Top 10mm thick rendering coat mixed with water proofing compound shall be laid over 10mm thcik plastered surface) with CM (1:4) on of brick work or concrete surfaces finished the surface even and smooth without using extra cement to match the existing surface complete in all respect as specified and directed. Note: WPC shall be measured and paid separately
M&L for Rendering 15 mm thick in CM (1:6) on other than fair face of brick work or concrete surfaces and finished the surface fair & even without using extra cement to match the existing surface all complete all as specified and directed.
M&L for Rendering on ceiling 5 mm thick in cement mortar (1:3) on of concrete surface finished even and smooth with out using extra cement complete all as specified and directed.
Supply only Integral water proofing compound complete in all respect as specified and directed.
Taking down of Chowkhat with shutter (without taking of shutter) area exc 1.5 Sqm but not exc 4.0 sqm complete all as specified and directed.
Taking down of Chowkhat with shutter (without taking of shutter) area n. exc 1.5 Sqm complete all as specified and directed.
S&F 2nd Class HW Plain, solid, straight chowkats and frames, wrought framed rebated on the solid, rounded or chanfered, put together with glue pinned at joints all as specified and as directed.
M&L for 30 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specificed and directed.
M & L for Cub-boards shutters made with Prelaminated particle board 18/19 mm thckness interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete in all respect as specified.
S&F 30mm thick 2nd class hard wood gauged & skeleaton shutter, open rebated & prepared to receiv e gauged, ( without sash bar ) eadge of framing plain, chamford or rounded, fitted with cut & mitred beads for securing gauged etc complete in all respect as specified and directed.
M&L for cement concrete type B0 (1:2:4) 12.5 mm graded aggregate as in hold fast block kerbs or mud stops, rounded or chamfered etc comlete all as specified and directed.
S&F for Factory made single extruded WPC(Wood polymer composite) solid door Frames of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), mimimum compressive strength of 58 N/Sqmm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant & fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as directed.
S&F for Factory made single extruded WPC(Wood polymer composite) solid flush door shutter of 30mm size comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum density of 650 Kg/cum, screw withdrawal strength of 1800 N(Face) & 900 N (Edge), mimimum compressive strength of 50 N/Sqmm, modulas of elasticity 850 N/sqmm & resistance to spread of flame of class A category with property of termite/borer proof , water/moisture proof & fire retardant & fixing with SS butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per dirns of EIC.
Supply and fix Aluminium powder coated of 18 mm width, three track sliding window frame with shutters with (2 nos glazed and one wire gauzed shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete with glazing and including 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc with the following section of frame and shutter:- (A) Sections for shutter :- (i) "H' section 39 x 20 x 1.50 mm thick. (ii) 'Interlock' section 39 x 20x 1.50 mm thick. (iii) 'Edge & Bottom' section 41 x 20 x 1.50 mm thick. (B) Section for frame :- (i) Top & Sides 123 X 29.70X 1.50mm not less than 1.30 Kg /RM. (ii) Bottom 123 X 29.70 X 1.50mm not less than 1.502 Kg /RM and complete all as specified and directed. Note Nos :- (i) All window member including fitting & fixture i.e frame, track, shutter frame, glass & wire mesh etc shall be deem to included quoted rate. (ii) Only measure opening size of window. (iii) The drawing of window shall be approved by the GE prior to incorporation in the work.
S&F Anodised powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators etc with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Material and labour for power coated anodised aluminium door shutters, aluminium section weighing 1.00 Kg/ m (minimum) thickness not less than 2.00 mm including necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, floor hinges, anodised aluminum snap beading screws etc. Complete all as specified and as directed.
Providing and fixing anodised aluminium grill (anodised trasparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standerd section and fix to the existing window frame with C.P braas/stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium stander section around the opening, all complete as per requirement and direction of engineer in charge. (only weight of grill to be measured for payment)
S&F 4.8 mm thick Sheet glass, ordinary quality and glazing in square n.exc 0.5 sq. m in each pane fixed to aluminium frame work complete all as specified & as directed.
S&F Extruded aluminium alloy handles 150 mm long, fabricated type,anodised complete all as specified & as directed.
S&F 300mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots and sliding bolts of extruded or cast aluminium alloy complete all as specified & as directed.
S&F Aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt, all as specified .
S&F Aluminium anodised barrel tower bolts of extruded section with 200 mm long bolt, complete all as specified & as directed.
S&F Hinges 100 mm, cast brass, with mild steel hinge pin, bright polished and fixed medium wheight , complete all as specified and directed.
S&F 150 mm long Aluminium handles, cast type, anodised complete in all respect as specified and directed.
S&F 100 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-22 complete in all respect as specified and directed.
S&F 100 mm long Aluminium anodised, barrel tower bolts of extruded section complete in all respect as specified and directed.
S&F 2nd class hardwood Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each complete in complete in all respect as specified and directed.
S&F in repair Stainless steel wire cloth having 0.36 mm nominal dia of wire and average width of appreature 1.40 mm and fixed with stainless wire staples complete all as specified & as directed.
S&F Mild Steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates; hook and pintle hinges large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified & as directed.
S & F Aluminium Anodised Hasp and Staple, including bolt to hing plate and fixed with screws 100 mm size at any storey of building complete in all respect as specified.
S&F floor door stopper overall length of cover plate 150mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & as directed.
S & F Veneered decorative Plywood with decorative face veneers on one face of grade BWR, type BB, fixed with screws to timber frame work 12 mm thick incl all necessary fittings complete in all respect as specified.
S & F Brass Locks with two levers , drawer, grade I, size 50 mm incl all necessary fittings complete in all respect as specified.
S & F Bras Drawer pulls, 3 screw plate with fixed dished pull; 80 mm to 100mm long incl all necessary fittings complete in all respect as specified.
S & F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete in all respect as specified
S & F 75 mm Butt hinges stainless steel, and fixed incl all necessary fittings complete in all respect as specified.
S & F Aluminium handles 100 mm length, cast type, anodised incl all necessary fittings complete in all respect as specified
M & L 2nd class hardwood Plain fillets.square, rectangular or triangular in section, clean sawn, secured with nails or brads Not exc 3 Sqm complete in all respect as specified
S&F Sinks in repair with drainage board made of stain less steel 1mm thick, with plugs, washer and wastes; Including bedding in cement mortor to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm. Complete all as specified and as directed.
S & F Continuous (piano) hinges, 30 mm width of flaps (when open) mild steel, bright finish or electro galvanised complete in all respect as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness in floors,aprons etc laid, bedded & pointed in any mortar complete in all respect as specified and directed.
Demolition of cement concrete of any description and in any position not other wise specifiy provided for complete in all respect as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete, including over 20 mm thick screed bed in CM (1:6) all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type 'B-0' using 12.5 mm graded crushed stone aggregate as in sub base complete all as specified and directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar bedding (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, including over 15 mm thick screed bed in CM (1:4) complete in all respect as specified and directed. Note : Size of Granite shall be decided by GE
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete in all respect as specified and directed by Engr-in-Charge.
Dismantiling of floor hearth or wall tiles incl cement mortar (but not backing), and rubbish off the premises (out of MOD land), complete all as specified and directed.
Material & Labour Non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular area of each tile exceeding 0.18 Sqm and not exceeding 0.38 Sqm , in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed layer in CM (1:4) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushign neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and as directed.
M&L non-skid joint free ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.18sqm but n.exceeding 0.38 sqm in skirting etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match complete, including over 10 mm thick backing coat in CM (1:4) all as specified & as directed.
Material & Labour Non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular area of each tile exceeding 0.06 Sqm and not exceeding 0.11 Sqm , in toilet / bath floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed layer in CM (1:4) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushign neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and as directed.
M&L for glazed ceramic (coloured) tiles of size 450x350 6-7mm thick as in vertical surface/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match complete, including over 10 mm thick backing coat in CM (1:4) all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete in all respect as specified and directed.
Taking up or down 15mm bore steel water tubing and connections,including cleaning for removal to store(GI Pipe) complete all as specified and as directed .
All as per item No 62 here-in-before but for 20mm bore steel water tubing complete all as specified and as directed.
All as per item No 62 here-in-before but for 25mm bore steel water tubing complete all as specified and as directed.
All as per item No 62 here-in-before but for 40mm or 50mm bore steel water tubing complete all as specified and as directed.
S&F CPVC pipes 16 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as in walls, ceiling, floor, etc. complete all as specified and directed.
All as per item No 66 here-in-before but for 20 mm outder diameter CPVC pipes complete all as specified and directed.
All as per item No 66 here-in-before but for 25mm outder diameter CPVC pipes complete all as specified and directed.
All as per item No 66 here-in-before but for 40mm outder diameter CPVC pipes complete all as specified and directed.
All as per item No 66 here-in-before but for 50mm outder diameter CPVC pipes complete all as specified and directed.
S&F UPVC pipes 50 mm bore (Outer dia) of SCH-40 and plain UPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as directed.
S&F 20 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified & as directed.
All as per item No 72 here-in-before but for 25mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified & as directed.
All as per item No 72 here-in-before but for 40mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified & as directed.
All as per item No 72 here-in-before but for 50mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA) complete all as specified & as directed.
S&F 20mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified & as directed.
All as per item No 76 here-in-before but for 25mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified & as directed.
All as per item No 76 here-in-before but for 40mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified & as directed.
All as per item No 76 here-in-before but for 50mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA) complete all as specified & as directed.
Dismantling of 100mm cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified & as directed.
S&F 110mm bore PVC(SWR) pipe single socket in any length rubber ring joints complete in all respect as specified and directed.
S&F 110mm dia PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls complete in all respect as specified and directed.
S&F 110mm bore PVC(SWR) pipe bend single socket complete all as specified & as directed.
S&F 110mm PVC (SWR) WC connector bent type complete all as specified & as directed.
S&F in repair PVC (SWR) vent cowl 110 mm dia complete in all respect as specified and directed.
S&F PVC (SWR) 110 mm bore junction single, (Single T) equal or unequal complete in all respect as specified and directed.
S&F PVC (SWR) 110 mm bore junction double, (double T) equal or unequal complete in all respect as specified and directed.
S&F in repairs vitreous china squatting pan of “Orissa” pattern of size 580 mmx 440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed.
Supply and fixing of Vitreous china wash down water closet (pedestal pattern) with concealed S-trap or P-Trap, white, 390 mm high, seat cover including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc and including taking down existing one complete all as specified and as directed
Supply PVC valveless, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia of make as approved by GE complete all as specified & directed.
S&F in repairs vitreous china wash hand basin, white, flat back, size 550mm x 400mm, exc chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & PTMT waste coupling of 32mm dia complete all as specified and directed.
S&F in repairs Brass chromium plated bottle traps of 32 mm bore for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap fixed complete all as specified and directed.
S&F 15mm bore in repairs CP angular valve with crutch handle, screwed for iron pipe or for brass ferrule and fixed of following size comlete all as specified and directed.
S & F 15 mm Dia in repairs CP Bib taps, with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed .
S & F in repairs 15 mm Dia CP stop cock (concealed) fancy type, chromium plated with long shank and cup comlete all as specified and directed.
Supply and fixingg in repair of chromium plated pillar cock cast copper alloy screwed down with long body with wall flange, and fixed for 15 mm bore GI tube pipe and all accessories complete all as specified and as directed. complete all as specified.
S&F in repairs 50 mm Dia brass gun metal gate valve , with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore Brass CP Health faucet screwed down for iron pipe and fixed all as specified and directed by the Engr in Charge.
S&F PVC connection 15 mm size pipe with PTMT nut of Length 450mm comlete all as specified and directed.
S & F in repair 75 mm floor trap fixed in floor with grating incl jointing with solvent 1:2:4 cement concrete,complete all as spd and directed
S&F in repair brass CP Shower roses in repair with or without swivel joints, 125mm size, including fixing to steel pipes or union comlete all as specified and directed.
S&F soap dish, vitreous China white, approximate size 160x 160x90mm fixed to plugs with chromium plated brass screws comlete all as specified and directed.
S&F PTMT in repair grating of 100mm dia, fixed with cement mortar (1:3) complete all as specified and directed.
S&F in repair brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
S&F in replacement Curtain rails with all fittings of 20 mm dia complete all as specfied and directed.
S&F Brackets with all fittings complete all as specfied and directed.
Dismantling of old unserviceable water tank, removing to store, Supply and fixing of rotational moulded polythene water storage tank 1000 litre capacity ISI marked (cylindrical, vertical, double layered with closed top) hoisted and fixed in position including PVC float valve 20mm bore weight not less than 210gms. Complete.
Dismantling of old unserviceable water tank, removing to store, Supply and fixing 2000 Litre capacity rotational moulded polyethylene water storage tanks (multilayer.cylindrical vertical with closed top) with and including 50 mm dia PVC float valve hoisted and fixed in position complete in all respect as specified and directed.
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. beams, columns,Slab,chajja,fins etc. 50 mm average thickness including tapering all edges, making square shoulders of cavities air and cleaning of exposed concrete surface of lightly picking materials by manual method including foreign materials , loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and directed.
Removing of concrete all around reinforcement bar upto 12 mm dia and over from behind the reinforcing bars average 25mm (but not less than 15mm air gap)by manual methods (using wire brushing ,chiselling etc) and applying chloride free rust removing chemical on rusting steel reinforcement bar and removing all rust from steel reinforcement bar by emery paper and cleaning the area throughly by water and allow it to dry and totally rust free of reinforcement bar all as complete as per manufacturer's instruction as specified and as directed.
Material , labour and prepared existing reinforcement surface by brush and application two component epoxy zincrich primer on existing reinforcement surface of minimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2 and maximum coverage area 5.00 Sqm per litre complete all as specified and directed.(INCL necessary scaffolding)
Material and labour for introducing new reinforcement bars upto 12 mm dia and over for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling,fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed inluding necessary scaffolding complete all as specified and directed.
Material , labour and placing in position free flow shrinkage cementitious micro concrete of compressive strength, flexural strength shall not be less than 50 MPa at 28 days , 5MPa at 28 days respectively for strengthening of beams, columns & other structural elements of average thickness 50mm and including surface preparation & suitable type formwork etc. as per manufacturers instruction complete all as specified and as directed.
Supply, materials and application of two component structural grade polymer modified reinstatement mortar of compressive strength, flexural strength shall not be less than 45 MPa at 28 days , 7MPa at 28 days respectively (Maximum coverage area 1.3 sqm per 25 kg pack @ 10 mm thickness) over a coat of epoxy Bonding agent on existing surface for strengthening of beams, columns & other structural elements of average thickness 25mm and morter shall be applied in layers n.exc 6mm thick in layers and including surface preparation as per manufacturers instruction complete all as specified and as directed. Note:- This item shall be executed where shuttering is not possible or small patch repairs of structural elements.
Material , labour for applying of high efficiency polymeric resin base film forming curing agent/compound over concrete surface and maximum coverage area 5.00 Sqm per litre as per manufacturers instruction complete all as specified and as directed. (INCL necessary scaffolding)
Dismantling of existing Expansion joint system and M & L applying TPO/FPO based joints sealing membrane, Sikadur Combiflex SG (150x2mm) with epoxy adhesive, Sikadur 31 C ( the joint shall be packed withing polystyrene board before application of Combiflex ). Then providing Sika pllystrene sealant into the gap after proper surface prepration after filling the gap with polyurethene backer rod, followed by precast RCC slab (1:2:4 ) 50 mm thick placed over the joint with minimum 150 mm projection on either side with proper drip course of size (length) n.exc. 1.2 mtr each and sealing the joints of precast RCC slab with exterior grade silicone sealant of size i.e. 10 mmx 10 mm balance with polystrene board complete all as specified and as directed by the Engr -in-Charge.
Supply and Application Cementitious Grouting Admixture with the Cement slurry at a dosage 225 ml per bag of cement and injecting with high pressure by a Pressure grouting Pump through non return PVC nozzles Prefix with rapid setting cementitious Plugging Mortar to fill all possible pores and gaps left within the old concrete mass. When the flow of grout stops or shows refusal or grout flows out from the adjacent nozzle, pumping to be stopped and the nozzle to be tied up and allowed to set for 24 hours. The PVC nozzles to be sealed off with quick-setting cementitious plugging mortar. Grouting operation to be carried out through next nozzle till the entire area is covered. The grouting holes to be finished by removing the protruded portion of nozzles and finishing flush with the surface complete all as specified and directed.
Providing and fixing of peg set (six pin) including all necessary fittings complete all as per manufacturer's instructions and all as specified and as directed by the Engr-in-Charge.
Providing and fixing of washroom glass Corner shelf (Three tier) with stainless steel railing including all necessary fittings complete all as per manufacturer's instructions and all as specified and as directed by the Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F collapsible steel gates, top hung consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets, complete all as specified and directed.
Taking down RCC jali of any description and dimensions complete all as sepecified and directed.
Taking out/Stripping of old Roof treatment membranes/Tar felt incl layer of cement mortar of any type carefully from roof surfaces (without damaging roof ) and incl preparation of old roof surfaces by picking, sweeping, cleaning and washing down with water to remove dust & receive new treatment complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type 'B-0' using 12.5 mm graded crushed stone aggregate finished with even and smooth without using extra cement complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar 1:4 mixed with Water Proofing Compound as per manufacture's instructions and top surface of rendering finished even and smooth to recieve water proofing treatment complete all as specified and directed. Note : Water Proofing Compound shall be measured and paid separately.
Supplying and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt laying over a coat of bituminous primer @ 0.40 Ltr / Sqm and two coats of Bitumen based UV reflective paint with aluminium finish over APP membrane. The membrane shall be laid using butane torch and sealing all joints etc all as specified in Para 11.44.5 of SSR Part I complete all as specified and as directed.
M&L cutting out cracks to "V" section in existing roofs of terracing cleaning out, wetting, grouting, with cement sand slurry 1:3 complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling of old Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings compete all as specified.
S&F Steel work in tubular trusses, posts,rafters, struss etc including special shaped washers etc. complete using ERW or induction butt welded tubes incl preparation surfaces and applying one shop coat of Zinc chromate primer paint etc.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified.
S&F for Pre painted galvalume aluminium zinc coating GI based corugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
S & F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-16 complete all as specified and directed.
M&L two Coats of Synthetic Enamel Paint over one coat of red oxide to steel and iron surfaces of any description, not otherwise described including preparation of new or previously untreated surface complete all as specified and directed.
M&L one Coat of Synthetic Enamel Paint to steel and iron surfaces of any description, not otherwise described including preparation of Old painted surfaces surface complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of pink primer area exc.10cm width or girth over new wooden surfaces including preparation of surface complete in all respect as specified and directed.
M&L for one coat of synthetic enamel paint, area exc.10cm width or girth over Old painted wooden surfaces including preparation of surface complete in all respect as specified and directed.
M&L for applying Finishing walls in new surfaces with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete in all respect as specified and directed by the Engr-in-Charge.
M&L for applying Finishing walls in old surfaces with Acrylic Smooth exterior paint of required shade (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) with complete removal of existing paint complete in all respect as specified and directed.
M&L preparation of new plastered surface and applying three coats of white wash on ceiling all complete all as specified and directed.
M&L for preparation of old plastered ceiling surface by complete removal of existing treatment and applying two coat of white wash complete all as specified and directed.
M&L for preparing surfaces new decorated plastered surfaces of wall, pillasters, cornices etc and applying two coat of acrylic distemper with 1 mm wall care putty complete all as specified and as directed.
Material & Labour for two coats of acrylic distemper (white or coloured as per site reqmt) on previously untreated old plastered surfaces of wall including preparation of surface, complete all as specified and directed.
M & L for Cement concrete in saucer drains Type B1 1:2:4 (20 mm graded aggregate) slope maintained as per site requirement complete in all respect as specified.
M&L for 75mm thick PCC (1:3:6), type C2, using 40mm graded stone aggte as in plinth protection / paving, surfae finished even & smooth with using extra cement as complete as specified and directed.
Demolition of cement concrete of any description and in any position not other wise specifiy provided for complete in all respect as specified and directed.
M&L 100mm thick cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed by the Engr-in-Charge.
Material and labour for pre-polished chequered Cement Concrete tiles of 25 mm minimum thick, size of (square/ rectangular) area of each tile exceeding 0.09 Sqm but not exceeding 0.16 Sqm double layer machine pressed set ( as per IS 1237-2012), jointed and pointed in neat cement slurry in floors and cut & polished in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Material , Labour and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade confirming to IS 15658-2006 with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed..
Taking down carefully existing aluminium/copper point wiring (for light, fan, socket & power) alongwith fittings (switches, ceiling roses, tuve light fittings, bulk head fitting regulator, sockets, main switches, DB) complete, removing materials to store and making good of disturbed surfaces of walls / floors etc to match with existing all as specified and directed.
M&L for point wiring complete as specified with 1100 V grade with 1.5 Sq mm single core PVC insulated unsheathed FRLSH cable, copper conductor multistranded passing through including concealed PVC conduit not less than 20mm dia with concelaed modular box suitable for logic modular switches, sockets etc with logic modular white plates, sorroundings of suitable size as required at site with PVC insulated FRLSH unsheathed stranded copper conductor of size 1.5 Sqmm as earth wire connected tocommon earth duly as specified complete all as specified and directed for the following:- Note:- (i) Rate quoted shall include for cost of making MS box and concealed in wall including cutting and sinking of boxes and making good to the walls (No extra payment will be made for the same) (ii) Provision of cover plate and blank plates as per site requirement (No extra payment will be made for the same) (a) For One light point / one fan point controlled by one, one way switch
All as per item No 152 here-in-before but for 5 Amp switch socket on the same board complete all as specified and directed.
All as per item No 152 here-in-before but for 5 Amp switch socket on independent board complete all as specified and directed.
All as per item No 152 here-in-before but size of cabl 4.0 Sq mm with earth wire of 4.0 Sqmm complete all as specified and directed.
All as per item No 152 here-in-before but for 2 way point wiring with cable of size 1.5 Sqmm with 1.5 Sqmm earth wire suitable for light points at stair case (Staircase lights) complete all as specified and directed.
All as per item No 152 here-in-before but one bell / buzzer point controlled by one push button on the same board with other switches independent complete all as specified and directed.
Supply and fixing Switch modular type, single pole, one way, 5/6 Amp, one module complete all as specified and directed
Supply and fixing Switch modular type, single pole, two way, 5/6 Amp, one module complete all as specified and directed
Supply and fixing switch modular type, single pole, one way and 15/16 Amps, one module complete all as specified and directed
Supply and fixing socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, two module, modular type complete all as specified and directed
Supply and fixing socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, modular type complete all as specified and directed
Supply and fixing Switch modular type, single pole, Bell push, 5/6 Amp, one module complete all as specified and directed
Supply and fixing in replacement of bell ding dong type AC, 230 volts, single phase complete all as specified and directed.
Taking down, strip opening, cleaning all parts and packing of ceiling fan / exhaust fan of any make and size and greasing ball bearing with specified quality grease and re-assembling the ceiling fan as a one unit complete all as specified and directed.
Material & Labour for hanging / fixing ceiling fan / exhaust fan in position and re-commissioning the same including making electric connection complete all as specifide and directed.
Supply and fixing in replacement of ceiling rose of size 65 x 50mm surface baelite 240 Volts three terminal complete all as specifide and directed.
Supply & fix LED tube 20 W Tube light fitting LED Batten with square profilr and polycarbonate channel with three core flexible copper conductor cable of suitable size from ceiling rose up to 1.5m length complete all as directed
Supply & fix VTPN prewired distribution board 200 Amps as incomer and suitable SPN / TP MCBs as outgoing double door type sheet metal enclosure 415V with 200 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable for 8 way complete all as specified and as directed by Engineer-in-Charge. Note:- rates of MCCB and MCB SPN / SP / TP shall be paid under respective item.
Supply & fix MCB DB SPN double door 12 way, IP 43 protection concealed on wall complete all as specified and directed.
Supply & fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning all as specified and directed.
Supply & fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40 to 63 Amps, in the MCB DB complete with connection testing and commissioning all as specified and directed.
Supply & fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning all as specified and directed.
Supply and fix in replacement MCCB 200 Amp FP, 415 volts 16KA all as specified and directed by Engineer-in-Charge.
Supply & fix power unit 32 Amps including socket 25 Amp, 06 module metal box for mounting of power unit complete all as specified and directed
M&L for sub main wiring with two single core PVC insulated, unsheathed, multistranded flexible copper conductor 1100 volts grade, FRLSH type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 6 Sqmm 1100 volts grade, FRLSH type, PVC insulated and unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Three runs of cables drawn in conduit will be measured as one length of sub main (ii) PVC conduit and its accessories is deem to be included in unit quoted rate. (iii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc
All as per item No 176 here-in-before but of size 4.0 Sqmm complete all as specified and directed
Dismantling and taking down from existing position split type AC of capacity 1.5 / 2 Ton and refixing the same in new position including necessary gas charging, cutting, opening, fixing, connecting, testing and making good disturbed surface of old position and new position etc all as specified and directed
M&L for taking down and refixing single phase electric energy meter any type and depositing at MES store yard Complete all as specified and directed.
Supply & fixing in repair building security lighting of LED 35 watts high efficient lighting solution anodised with heat resistance with accessories provided including necessary electric conection with all accessories required for fixing / mounting with nut bolt washer & clamp support on GI pipe 1.5 meters long of suitable diameter complete all as specified and directed
M & L for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4.0mm GI wire (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 5 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering all as specified and directed and tested on completion including taking down / up existing one.
Excavation in trenches not exceeding 1.5 mtr deep and 1.5 mtr width as in soft loose soil complete all as specified and directed
Returning, filling including leveling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified and directed
Removal of surface soil to a distance distance not exceeding 50m and deposited where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Supply and laying DWC of 50mm bore size complete all as specified and directed
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as directed
Note: Schedule of credit amount shall be deducted from the total quoted amount of BOQ.
NIRMAL SALES CORPORATION (BID ID -3157818)
DNS CONSTRUCTION COMPANY (BID ID -3157811)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .