Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.9 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹47.5 L+₹4.6 L (10.8%)Rejected-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹49.5 L+₹6.7 L (15.6%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in particular category c(vi) | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in particular category c(vi) |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
26 Dec 2023, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIR/MAINTENANCE OF WATER SUPPLY, DG SETS, FIRE FIGHTING SYSTEM OF NEWLY TAKEN OVER FROM CCE RND BLDGs OF NANO LAB, MAIN BLDG DMRL/ATC DEVATALLAGUTTA AT KANCHANBAGH, HYDERABAD
2023_MES_631449_1
8689/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹88,000
Yes
5 Feb 2024
6 Dec 2023
28 Dec 2023
6 Dec 2023
26 Dec 2023
19 Dec 2023
7 Dec 2023 - 13 Dec 2023
Amount
Fire Fighting
Testing and Refilling of Foam type Fire Extinguisher 9 Ltrs. Capacity complete fully charged gunmetal cap heavy inner container with wall mounting brackets etc. confirming to IS: 933. Make: Safex / Geo /Konex
Testing and Refilling of Dry Chemical Powder type Fire Extinguisher 5 Kg. Capacity powder and CO2 gas cartridge of 120 gms. Capacity confirming to IS: 2171.
Testing and Refilling of Dry Chemical Powder type Fire Extinguisher 9 Kg. Capacity powder and CO2 gas cartridge of 180 gms. Capacity confirming to IS: 2171.
Testing and Refilling of Carbon – Di – Oxide type Fire Extinguisher 4. 5 Kg. Capacity CO2 gas confirming to IS: 2878
Taking down old unserviceable hydrant valve and Supply, Installation, Testing and Commissioning of Single Headed Hydrant valve confirming to IS 5290 with ISI mark of size 63 mm dia oblique type with instantaneous hose coupling adaptor etc. with all necessary fitting materials complete required.
Taking down old unserviceable hydrant hose pipe and Supply, Installation, Testing and Commissioning of Hydrant hose pipe, 63 mm dia and 2x15 mtrs long RRL type with Gunmetal 63 mm size male coupling at one end and female coupling at the other end. It should with stand a bursting pressure of 450 psi, rot proofed, with ISI mark. Hose shall comply to IS 636
Taking down old unserviceable hose reel pipe and Supply, Installation, Testing and Commissioning of Fire Hose Reel pipe 20 mm dia. X 30 mtr. Long, high pressure with 5 mm out let GM nozzle with shut off valve(IS: 884 - 1969) includes stop cock and chromium plated nozzle with all necessary fixing materials complete all as directed.
S&F in repairs sprinkler bulb Spirit type 60 to 70 degree temperature fusible range suitable for fire fighting sprinkler system complete all as directed.
M&L for Scrapping of old existing paint of pipe lines for Fire fighting system of any sizes and applying two coats of enamel paint to match with the existing shade complete all as directed. Note - Rate quoted shall be deemed to include cost of Paint & tools. Make - ASIAN/SHALIMAR/BERGER
Scrapping of old existing paint of Fire cabinet (inside & outside) for Fire fighting system of any sizes and applying two coats of Red postal colour enamel paint. Note -Rate quoted shall be deemed to be include rates of Paint & tools. Make- ASIAN/SHALIMAR/BERGER
M&L for rewinding of the electric motor of 60 HP capacity duly disconnecting and taking down electric motor from the existing position and inspecting the same, transporting to workshop for repairs and bringing back. Cutting and removing the burnt out winding conductors rewinding the same with same gauge and weight of insulated super enameled copper conductor and providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment along with pump set connecting up with the electrical system, testing and commissioning complete all as directed. Main Bldg ATC D'gutta
Repair and servicing of 60 to 100 HP Fire Fighting Pump and motor including all connecting parts by replacing gland, greasing & oiling and rectification of alignment of pump and motor, cleaning the carbon from the electrical connections and commissioning complete all as directed.
Repair and servicing of 7.5 to 12.5 HP Fire Fighting Pump and motor including all connecting parts by replacing gland, greasing & oiling and rectification of alignment of pump and motor, cleaning the carbon from the electrical connections and commissioning complete all as directed.
S&F of following parts of Fire fighting system with all necessary electrical connection with lugs of any size and testing commissioning including taking down the same complete all as directed.
Contactor for fire Panel MNX 70 3Pole Make : L&T/C&S/ Legrand
Electronic Timers Type ET 100 ML-6, 9-30 Sec, 415V, 50 Hz Make : L&T/C&S/ Legrand
High Pressure control guage 02-14 Bar, 0-55 PSI , KP-36 Make : Denfoss
S&F DWC pipe 40 mm HDPE double wall corrugated pipe cable ducting ,underground electrical conduits complete all as specified and directed.
DG Set
Maintenance of DG set and carrying out ‘B’ check and replacement of ‘B’ check kit filters such as Oil filter, by pass filter, fuel filter,CR element and CR plates complete with ‘O’ rings and draining of Engine oil and topping up with the new engine oil complete testing all as specified and directed by the Engr-in-Charge for the following capacity DG sets:- Note :- 1. Engine oil shall be measured and paid separately. 2. B Cheak to be carried out every after 250 hrs run or 6 months whichever is earlier. Make: KIRLOSKER/ CUMINS /GREAVES
100 KVA DG Set
500 KVA DG Set
Blank
Blank
Renewal of unserviceable batteries with maintenance free batteries of 180 AH, 12V including connecting to DG set complete all as directed. Make:- EXIDE/ AMARON/SF Sonic
Attending the breakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and identifying and rectifying the faults and submit report to concerned JE complete all as directed. Note :- Spare Parts for rectifying the fault shall be measured and paid separately.
S&F in repairs automatic voltage regulator (AVR) up to 100 KVA DG set and testing complete all as directed. Make:- As per OEM make.
S&F in repairs automatic voltage regulator (AVR) 500 KVA DG set and testing complete all as directed. Make:- As per OEM make.
Dismantling of exhaust pipe of the DG set by unscrewing nuts and bolts and taking down the pipe with muffler, removing the burnt out asbestos rope and well wrapping with new aluminum metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directed for the following capacity DG Sets.
100 KVA DG set.
500 KVA DG set.
Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 24 volts, 180 /200 AH and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts such as bearing, carbon brushes, clutch plates etc refixing the self starter in its original position, testing and commissioning complete all as directed. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule fixing included in this item.
Supply only Armature coil for self starter of any make of any capacity and of any model 24 Volts, 180/200 AH complete all as directed.
Supply only of field coil for self starter of any make, any capacity and any model 24 Volts, 180 /200AH complete all as directed .
Disconnecting the oil cooled of 100 KVA to 500 KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed.
S&F in repairs air cleaning element inner and outer with necessary ‘O’ rings for the DG sets of following capacities as that of existing make and model complete all as directed.
Upto 100KVA DG Set
100 to 500 KVA DG Set
Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and of various capacities of DG sets and taking down the radiator assembly by unscrewing all mechanical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly cleaning thoroughly the chocked pipe of the radiator by using detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers etc., complete all as directed for the following DG sets:-
Upto 100 KVA DG Set
100 to 500 KVA DG Set
Renewal of battery cable leads of copper conductor with brass lugs terminal, for the 12V 180 /200 AH batteries for self startor as that of existing size and length complete all as directed.
S&F in repairs automatic cut off Battery Charger suitable for 110V, up to 40 Amp Battery complete all as directed . Make SMPS/ Phonix
S&F in repairs automatic cut off Battery Charger suitable for 12/24 V, up to 40 Amp Battery complete all as directed. Make: SMPS/ Phonix
S&F in repair Renewal of 'V' belts for the following capacity DG sets as per existing size and model complete all as directed. Make :- FENNER/ DUNLOP
Upto 100 KVA DG Set
100 to 500 KVA DG Set
S&F in repair of existing unserviceable water temperature gauge for the DG set of any description complete all as directed.
S&F Renewal of existing unserviceable lubricant oil temperature guage for the DG set of any capacity complete all as directed.
Renewal of existing unserviceable oil pressure gauge for the DG SET of any capacity complete all as directed .
S&F in repair of unserviceable Solenoid switch for DG set of any make and any capacity complete all as directed. Make :- RUSTON/ GREAVES COTTON/Kirloskar/CUMMINS.
Supply and filling the new engine oil 15W/40 for toping up, up to the required level complete all as directed. Make :- CASTROL/ INDIAN OIL/ SERVO
Drain out the fuel from the fuel tank of DG set of capacity up to 600 Ltrs and above and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including applying one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed.
Removing of defective engine oil control pressure switch and supply & fix new engine oil control pressure switch suitable for up to 500 KVA set complete all as directed. Make:- Kirloskar / Cummins/ OEM
Renewal of defective wiring with copper wire of existing size including replacement of electrical/ electronic parts of AMF panel & DG Set, complete all as directed. Note: - Supply only Electrical/ Electronic spare parts shall be measured and paid separately.
Supply only Auxiliary contactor 240 Volts, (2NO.+2NC).
Supply only ON and OFF delay timer 240 V AC and 24 V DC.
Supply only over load relay.
Supply only ML - 4 contactor.
Supply only earth Fault Relay IRII-31-E1-WD Suitable for 250 V, AC. Make: C&S
Supply only single phase preventer
Supply only auxiliary Relays 24Volts / 6A
Supply only PLC based AMF relay unit
Supply only Low lube oil safety switch
Supply only Booster Relay 24Volts / 10A
Supply only Battery charger 24 V /10A panel mounting type
Supply only Coolant temperature sensor
LED indicating Lamp
Push buttons
Removing the defective charging dynamo of capacity 24 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the same replacing of armature, field coils reconnecting the same, refixing back, in original position testing and commissioning complete all as directed.
Supply & topping up of Inhibitor corrosion (coolant additive concentrate) as required (TVS Make) complete all as directed.
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as directed.
Dismantling/taking out old unserviceable alternator (charging of battery) and taking out worn out spares such as ammeter, brush and field winding and repair the same by replacing ammeter, brush and rewinding of field coil with same guage of copper wire and testing complete all as directed .
Calibration of PT pump and replacement of PT Pump kit, gear gasket, etc whichever is required for smooth functioning of DG Set complete all as directed.
Calibration of injectors by replacing injector cup, barrel plunger for smooth functioning of engine, testing complete all as directed .
S&F PVC insulated, heavy duty, unsheathed , multi Stranded Copper Cable of 35 Sqmm single core with suitable size lugs crimped on both side complete all as directed.
S&F Flexible Bellow suitable up to 500 KVA Gen Set. Make as per OEM
Disconnecting of alternator from 100 KVA to 500 KVA capacity DG set, after Disconnecting from Generator shifting to civil workshop, taking out burnt out winding from Startor & Rotator, Cleaning thoroughly and rewinding the startor, rotor with suitable guage of super enameled copper conductor similar to that of existing size including necessary insulating material varnishing, heating, replacing bearings in rotor and startor side, reassembling of alternator, bringing back to the site refixing and installation over foundation with proper alignment, testing and commission in as complete all as directed. Note :- cost of taking up and down from the site to workshop vice versa with vehicle and necessary labour shall be deemed to be included in quoted rates.
Supply, fix and test run the Fly-wheel Ring of existing model, size suitable for DG set of capacity 100 to 500 KVA including taking down old unserviceable fly wheel ring complete all as directed.
Supply and fixing repairs Stan guard Auto Transfer switch (ATS) with enclosure of capacity 200 Amp 4 pole with automatic/manual with complete protection all accessories complete all as directed.
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model, size suitable to DG Set of capacity up to 500 KVA including taking down old unserviceable diesel feeder pump complete all as directed.
M&L for removing old rusted painted from complete DG Set surfaces of the DG Set of capacity up to 500 KVA complete with one coat of Primer and two coats of spray painting with existing colour paint synthetic enamel type including writing Ser No of DG set complete all as specified and directed.
Renewal of 3 pole 415 volts 50Hz Power Contractors of the following capacity including Connecting & testing complete all as directed by Engineer-in Charge.
MNX 25 Contractor
MNX 40 Contractor
S&F Repair/ replacement of timer 0 to 60 min complete all as directed.
WATER SUPPLY
Dismantling the Monoblock pump set of up to 5 HP capacity 3 ph, 415V, AC, 50Hz after disconnection of electric/ pipe connections and providing dummy plates to suction and delivery lines, Shifting to the reputed workshop for repairs and replacing of minor spare parts like gaskets, packings, nuts, bolts and washers etc, and greasing, reassembling and replacement of other major parts as required and factory testing the rated flow discharge of the pump shifting to the original location and reconnecting of pipes/ electric connections at site and testing to the entire satisfaction of the Engr-in-charge complete. Note : Parts like impellars, shafts, bearings, seal and lantern rings will measured and paid separately under relevant items of Sch A.
All as per item No. 75 but of capacity up to 7.5 HP
Supply only following spare parts suitable for Monoblock pumpset of capacity 3 to 5 HP
Cast Iron / Mild steel/ Carbon steel Impellar suitable for the rated discharge and capacity
Heavy thrust Ball Bearings of make : NBC/SKF
Gland Pack
Shaft sleeve
External fan
Lantern ring and assembly packing as per the existing model.
M&L for Rewinding of Centrifugal/ MonoBlock Pump Motor of 3Ph, 415V, AC, 50Hz with super enameled 99% copper winding wire (ISI marked brand) of gauge and turns per coil suitable for attaining the specified winding resistance as per the OEM details, Class H insulation paper for slots insulating, applying insulating varnish on the new coils and drying in the heating chamber, Testing the coils complete and connecting the terminals to the cable connector box, replacing the bearings , bushes bearing holders and other connected spares which are inescapable to complete the job all as directed for the following capacities. Note:- The winding resistance and insulation resistance after rewinding should be as per the OEM specifications and the test reports should be submitted before assembling the pump and motor.
Monoblock pump Motor of capacity 3HP
Monoblock pump Motor of capacity 5HP
Repair & servicing of existing pump starters in the LT control panels of any rating/ type and any capacity, Replacing unserviceable components such as contactors, Relays, Single phase preventers, meters, cable lugs, MCBs, Push buttons and CT coils etc including necessary wiring for DOL and Star- Delta starters using FRLS copper conductor of size not less than 1.5 Sqmm and necessary ferules and casing capping required to secure the wiring complete all as directed testing and commissioning to the entire satisfaction of the Engr-in-charge. Note:- (I) Components required for replacement shall be measured and paid separately under relevant Sch A items below.
Supply only following parts of pump panels and fixing in existing panels (to incorporate under item No above)
3 pole power contactor AC-3 type, 415 Volt Conforms to IS / IEC 60947-4-1 with required NO + NC add on blocks & operation voltage 380 to 400, suitable for 3HP pump motor as per the current rating of the OEM name plate. Make:- Schneider /Legrand/L&T
All as per item No 79 but for up to 5HP motor.
Star- Delta Timer
AC Volt meter digital display, flush mounted, 96mmx96mm size. 0 to 600 Volt Make : AE /L&T /HPL.
AC Amp meter digital display, flush mounted, 96mmx96mm size with CT coils - 3 No's, CTR 300:5. Make : AE/L&T/ HPL class 1 accuracy.
VAF+PF digital type class 1.0 accuracy meters with input voltage range 50-520V of size 96x96mm flush mounting type
S&F MCB TPN 63 Amps working on 415 volts, 50 HZ AC, 10 KA ,'C' curve . Make: Legrand/Havells/L&T
S&F MCB TPN 100 Amps working on 415 volts, 50 HZ AC, 10 KA ,'C' curve . Make: Legrand/Havells/L&T
S&F MCB TPN 32 to 40 Amps working on 415 volts, 50 HZ AC, 10 KA ,'C' curve Make: Legrand/Havells/L&T
S&F MCCB 100 Amps working on 415 volts, 50 HZ AC, 16 KA ,'C' curve. Make: Legrand/Havells/L&T
S&F MCCB 125 Amps working on 415 volts, 50 HZ AC, 16 KA ,'C' curve . Make: Legrand/Havells/L&T
Supply & fix 50mm GI pipe heavy duty with heavy sockets suitable for submersible pump set. Make : Jindal/Tata/Zenith
Supply only high strength Calcium hypo cloride granular disinfection chemical with Heavy metal(Mercury and Lead) containments below the detectable limit(BDL) as per the AAS test data all as specified. Make: ALTOCH-GP/ or any approved make of state board.
Supply only bleaching powder for all purpose of water treatment
M&L for arranging the scaff folding on any type of surfaces of height approx 20M for cutting the GI/CI pipe lines fixed on the over head tanks using necessary tools and replacing with new GI/CI pipe as directed. Note: The material will be measured and paid separately under relevant Sch A items.
M&L for preparing surfaces and painting the pipe lines with two coats of synthetic enamel paint of color as directed by the Engr-in-charge and marking the inflow/outflow arrows on the pipeline near the pumps/ sump/ OHT all as directed and specified
M&L for preparing the surfaces of the pump sets and painting with two coats spray painting with of synthetic enamel paint of approved color as directed by the Engr-in-Charge for the following pumps :-
3 HP to 7.5 HP sets
M&L for fabricating the base frame with ISMC channel sections of size 75x40mm of nominal thickness 4mm as per the existing design as required at site.
Material and labour for earthing complete with galvanized iron strip electrode 60x60cmx6mm thick, buried directly in ground(earth pit not less than 2.25metres deep below ground level) with top edge of the plate not less than 1.5metres below normal ground level, connected to galvanized earth lead strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 connected to switchgear equipments/motors protected by 40mm dia light grade GI pipe up to a length of 7.5mtr including necessary excavation earth work, charcoal and salt PCC 1:3:6 type C1 for chamber 40mm thick RCC cover slab 1:2:4 type B1 with 8 mm dia TMT bars @ 100mm c/c both ways, 20mm dia GI watering pipe medium grade with funnel complete and testing complete all as directed.
Material and labour for earthling complete with copper strip electrode 60x60cmx3.15mm thick, buried directly in ground(earth pit not less than 2.25metres deep below ground level) with top edge of the plate not less than 1.5metres below normal ground level, connected to copper strip of size 20x3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 connected to switchgear equipments/motors protected by 40mm dia light grade GI pipe up to a length of 7.5mtr including necessary excavation earth work, charcoal and salt PCC 1:3:6 type C1 for chamber 40mm thick RCC cover slab 1:2:4 type B1 with 8 mm dia TMT bars @ 100mm c/c both ways, 20mm dia GI watering pipe medium grade with funnel complete and testing complete all as directed.
M&L for Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
M&L for GI strip 32 x 6mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
Removing the unserviceable PVC tank lid of any size and Supply and Fix PVC tank lid with clamps suitable for following size of PVC tank capacity and all as specified and directed.
500 to 1000 ltrs capacity
Bailing out water completely from the underground sumps of the following capacities and cleaning internal surface of RCC under ground sump by using pressure jet pumps, bleaching powder, scrapping, removing the scales, dirt and washing out with water completely and applying two coats of cement wash as directed and writing the relevant information like date of cleaning, capacity etc with the black paint on white back ground at visible place complete all as directed .
up to 45,000 ltrs capacity at Booster pump house
M&L for preparation of old painted surface surfaces of MS pipe of any bore by scrapping the old paint and applying two coats of synthetic enamel paint of post box red and Blue, green colour over a coat of red oxide primer complete all as directed .
S&F in repairs Removing the existing unserviceable Bib taps and Supply and Fix Bib tap of size 15 mm dia standard of PTMT any colour and high pressure screwed for iron pipe and all as specified and directed.
Supply and lay M S Pipes heavy grade of size 80 mm dia with all fittings laid in floors or fixed to walls and ceilings etc of sizes as shown complete all as directed.
Taking out unserviceable DOL Starter from panel board after disconnecting electric connection and Supply and Fix DOL Starter suitable for 3 to 7.5 HP, 3Phase, 415Volts, AC, 50Hz and reconnection to existing system and testing complete all as as directed
Taking out unserviceable single phase preventer after disconnecting of electric supply and Supply and Fix Single phase preventer 415Volts, AC, 50Hz suitable for pumpset 3 HP to 10 HP and reconnecting of electric supply and testing complete all as directed Make:- MINILEC/L&T/SIEMENS
Supply and fixing HDPE pipe of 10 kgf /sqmm grade, 65/63mm bore with all fittings complete and suitable for submersible pump set.
Supply and laying UPVC pipe (SCH-40)50 mm bore, with all fittings complete all as specified and as directed.
All as per item No 105 above but of size 40 mm
All as per item No 105 above but of size 25 mm
All as per item No 105 above but of size 20 mm
Supply and laying K-7 DI Pipe 150mm with all fittings complete all as specified and as directed.
All as per item No 109 above but of size 100 mm
All as per item No 109 above but of size 80 mm
Supply and Fix sluice valve of size 150mm with all fittings complete all as specified and as directed.
All as per item No 112 above but of size 100 mm
All as per item No 112 above but of size 80 mm
Excavation in trenches in Hard/dense soil not exceeding 1.5 meter wide and not exec 1.5 meter in depth and getting out for taking out / laying of pipes and making bottom surfaces of excavation leveled.
Returning, filling in trenches with excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as directed by the Engineer-in-Charge.
Removing surplus soil / spoil to a distance not exceeding 50 meter away and depositing where directed at a level not exceeding 1.5 meter above the starting point all as directed by the Engineer-in-Charge.
Material and Labour for cutting of existing GI pipe line of 80mm dia for alterations and additions including threading of GI pipe and providing GI fittings of suitable size of 80/100mm as required at site of work including necessary excavation and earth work complete all as directed
M & L for brick work with sub class 'B' fly ash bricks, straight or curved on plan exec 6m mean radius and built in cement mortar 1:4 as in repair/raising /making of valve pit chamber.
M&L rendering 15mm thick plaster on fair faces of brick work or concrete surfaces with CM 1:4 and finished even smooth without using extra cement.
M&L for cutting existing road incl black top surfaces of required width and depth for laying of pipe line, refilling and making good after laying of pipe with removed soil and finally sealed with cement concrete of thickness not less than 200 mm to match with the top surface of Road.(Cement concrete shall be measured and paid separately under appropriate item)
M & L for cement concrete 1 : 2 :4 type C2 using 40mm stone aggregate, as in repairs to RCC pipe line/ Valve pits / disturbed hard standing or any other repair as required at site at any situation all as specified as directed.
Material and labour for construction of valve chamber of size 900x900x600mm internal size including necessary earth work and excavation, PCC 1:4:8 type D2 for foundation, brick work in cement mortar 1:4, PCC 1:2:4 type B1 for coping, 15mm thick rendering in cement mortar 1:4 including provision of mild steel cover 3mm thick on 40x40x6 mm angle iron frame work with 2 coats of synthetic enamel paint over a coat of zinc chrome primer and locking arrangements complete all as directed.
All as per item No.123 above but of size 600mm x 600mm x 600mm complete all as directed
Removing the existing un serviceable gate valve and supply and fix new gun metal gate valves with iron wheel head screwed on both ends for iron pipe with necessary GI fittings of the following sizes :- MAKE : Leader/Zoloto/kirloskar/Bir
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Supply and Fix Butterfly valve of size 150mm dia both ends flanged and drilled complete with all accessories of class PN 1.6 conforming to IS specifications and testing including removing the unserviceable valve complete all as directed Make :- KIRLOSKAR/ AUDCO / L&T /Upadyay
All as per item No. 126 above, but of size 100 mm dia
All as per item No. 126 above, but of size 80 mm dia
Taking out existing unserviceable non return valve of any type/size and supply and fix CI non return valve of 150 mm bore dia conforming to IS 5312 both end flanged and including necessary fixing arrangement as required at site by providing rubber/fibre gasket ,nuts, bolts & washers etc complete all as specified as and directed. Make :- KIRLOSKAR /AUDCO/ Kartar / L&T
All as per item No. 127 but of size 100 mm bore dia
Disconnecting the pipe lines and removing unserviceable / leakage storage tanks of any type from the buildings/plat form and supply and fix hoist and install of Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed lid) triple layered ISI marked white layer inside the tank and connecting all pipe lines of following capacities complete all as directed.
500 litre capacity
1000 litre capacity
Blank
Blank
S & F in repair float valves ISI marked high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball, screwed for 20mm bore iron pipe, including replacement of aduscent GI fittings complete, weight not less than 210 grm. Make : Prayag / Polytuff / Symet / Neta
S & F in repair float valves ISI marked high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball, screwed for 25mm bore iron pipe, including replacement of adjucent GI fittings complete, weight not less than 142 grm. Make : Prayag / Polytuff / Symet / Neta
S&F Foot valve suitable for 80mm dia pipe complete with flanges, packing, nuts and washers as required at site and testing as specified and directed. Make: Leader/ Kirloskar/L&T/ Sant
S&F Foot valve suitable for 100mm dia pipe complete with flanges, packing, nuts and washers as required at site and testing as specified and directed Make: Leader/ Kirloskar/L&T/ Sant
Dismantling and taking out carefully without damaging the brick masonry wall the wrought iron or mild steel work of any description damaged/ broken MS valve pit cover(frame with sheet) , ladder of water reservoir, shallow wells, strainer of foot valve etc complete all as specified and directed.
Supply, fabricate and fixing MS framed equal angle grills, gratings, framed guard bars, ladder, framework of Valve pit cover, water tanks, shallow wells etc, or similar work as ordered and fabricated from MS rolled section of any size and shape as directed and fixed at position with all fixing accessories complete.
M & L for Preparation of metal surfaces of any description, applying two coat of synthetic enamel paint of color as directed by the Engr-in-charge over a coat of red oxide primer complete .
Fixing only valve pit cover with frame on brick work properly without damaging any portion of valve pit and making good disturbed surfaces complete all as directed (existing valve pit cover and frame obtained shall be used.)
Dismantling and taking out unserviceable centrifugal pump set (Pump & Motor ) of capacity up to 5HP, of any Make/Model from its foundation by disconnecting water and electric connections, decoupling of pumps from motor shifting the Pump/Motor as directed and shifting to workshop for repair of unserviceable pump and carryout the following repair: a) Opening the pump completely part by part without damaging any parts,descaling and cleaning of all parts for inspection and finding serviceability / unserviceability of the parts. Note : (I) Spare parts required for replacement shall be measured and paid separately under appropriate items as supply only. (ii) Unit rate is deemed to be included for replacement of all Packing glad nuts, Packing gland, Packing, Impellar lock nuts , nuts and lock washer and any gaskets etc, required during repair.
All as per Item No. 140 above, but of capacity up to 7.5 HP
Supply only following spare parts suitable for centrifugal pumpset of up to 7.5 HP
Impellar (Bronze)
Casing Wearing Rings
Inlet Flange
locking sleeve
Flinger
Seal retainer
Oil seal
Bearings as per existing model. Make: SKF/NBC
Impellar and Shaft sleeve keys
Bearing Retianer
Shaft
Material and Labour for Rewinding of Centrifugal Motor of capacity up to 7.5 HP, 3Ph, 415V, AC, 50Hz with super enameled copper wire of same gauge and same number of turns and applying insulating varnish including removing the burnt out winding with out damaging to other parts and cleaning the slots etc and testing complete all as directed .
Supplying, laying in repairs and jointing by welding heavy duty class 'C' MS pipe of 100 mm bore confirming to IS 1239 incl fittings i.e. Tees, bends, elbow , unions, reducers, flanges etc as required and applying two coat of fire red enamel paint over a coat of anti corrosive paint complete all as directed.
Supply and Fix water supply distribution /installation board made with ACP board of size not less than 7x4 feet fixing to aluminum frame of required size, inkjet printing the colored layout submitted to the Engr-in-charge on water proof PVC sheet along with provision for LED lightning on top complete including necessary fixing arrangements as required at site.
M&L for replacement of indoor type ( IP 43 protection) star Delta starter panel of Monoblock/centrifugal pump set/ submersible complete of capacity up to 30 HP complete with comprising of Dry run protection, Under/Over voltage protection, over loading protection , Single phase protection, phase reversal protection along with indication, Overheating of winding protection, Unbalanced supply protection, etc complete all as directed.
M&L for Shutter removing and fixing and servicing and load adjustment
S&F Rolling shutter springs
S&F Rolling shutter gear warm
S&F Rolling shutter gear box
M&L for motor removing & refixing & servicing
S&F Rolling shutter HIP motor
S&F Rolling shutter motor starters
S&F Rolling shutter limit switches
S&F Rolling shutter side motor 1 ton capacity
Universal refrigeration and Engineering Company
S.S.ENGINEERING CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .