| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LQualified 01 VILLAGE BABOORI BARARI MATHURA UTTAR PRADESH 281005 | MATHURA | UTTAR PRADESH | 281005 | ₹9.4 L | L1 | Qualified MSE, MII, Category: General |
| 2 | L2₹9.7 LQualified | ₹9.7 L | L2 | Qualified MSE, MII, Category: General |
| 3 | L3₹9.9 LQualified | ₹9.9 L | L3 | Qualified MSE, MII, Category: General |
| 4 | L4₹10.4 LQualified | ₹10.4 L | L4 | Qualified MSE, MII, Category: General |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
17 Sept 2022, 9:00 pmClosed
Excavation in trenches in soft loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level
DI specials fittings of any type radius angle tapers increasing decreasing sockets tees tail pieces
Dismantling and taking out existing under ground CI DI pipes Spigot and socketed flanged screwed ends
Steel tubes medium grade ISI marked
galvanized with all fittings laid in trenches including taking up or down existing
Steel tubes medium grade ISI marked galvanized with all fittings laid in trenches including taking up or down existing
Steel tubes medium grade ISI marked galvanized with all fittings laid in trenches including taking up or down
Disinfection agent for water treatment
Cutting the existing CI DI pipes in position for inserting new pipe attachment tees or for making new branches etc
D Joint with two numbers of round rubber O rings
3795087
GEM/2022/B/2542895
Excavation in trenches in soft loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metr
90 days
Punjab; Jalandhar
Total value wise evaluation
BOQ
5 documents required · 5 mandatory
3 yrs
50%
Exempted
17 Sept 2022
15 Sept 2022
17 Sept 2022
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Excavation in trenches in soft loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth | Excavation in trenches in soft/loose soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on planand getting out complete, all as specified. | 136 | Cum | werty@123 | 90 |
| 2 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, after the pipes have been laid and tested complete, all as specified. | 122 | Cum | werty@123 | 90 |
| 3 | Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level | Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified. | 14 | Cum | werty@123 | 90 |
| 4 | DI specials fittings of any type radius angle tapers increasing decreasing sockets tees tail pieces | DI specials/ fittings of any type, radius, angle, tapers, increasing, decreasing sockets, tees, tail pieces and collars etc complete. | 1,000 | Kilogram | werty@123 | 90 |
| 5 | Dismantling and taking out existing under ground CI DI pipes Spigot and socketed flanged screwed ends | Dismantling and taking out existing under ground CI/DI pipes, Spigot and socketed / flanged/screwed ends of any length & type, including necessary fittings, buring of lead/rubber joints if any and bailing out water complete all as specified of size. 80 to 100 mm bore | 100 | RM | werty@123 | 90 |
| 6 | Steel tubes medium grade ISI marked, galvanized with all fittings laid in trenches including taking up or down existing | Steel tubes medium grade ISI marked, galvanized with all fittings, laid in trenches including taking up or down existing unserviceable steel tubing and connections, complete all as specified, of size as under 50mm bore NOTE Excavation and earthwork, will be measured and paid for separately under respective item. | 90 | RM | werty@123 | 90 |
| 7 | Steel tubes medium grade ISI marked galvanized with all fittings laid in trenches including taking up or down existing | Steel tubes medium grade, ISI marked, galvanized with all fittings, laid in trenches including taking up or down existing unserviceable steel tubing and connections, complete all as specified, of size as under 80 mm bore NOTE. Excavation and earthwork, will be measured and paid for separately under respective item. | 20 | RM | werty@123 | 90 |
| 8 | Steel tubes medium grade ISI marked galvanized with all fittings laid in trenches including taking up or down | Steel tubes medium grade, ISI marked, galvanized with all fittings, laid in trenches including taking up or down existing unserviceable steel tubing and connections, complete all as specified, of size as under. 100 mm bore NOTE. Excavation and earthwork, will be measured and paid for separately under respective item. | 80 | RM | werty@123 | 90 |
| 9 | Disinfection agent for water treatment | Disinfection agent for water treatment | 1,500 | Kg | werty@123 | 90 |
| 10 | Cutting the existing CI DI pipes in position for inserting new pipe attachment tees or for making new branches etc | Cutting the existing CI/DI pipes in position for inserting new pipe attachment/ tees or for making new branches etc. with joint & jointing material, including necessary excavation & earth work complete all as specified. 80 mm bore NOTE. Fitting will be measured and paid for separately under respective item. | 2 | Each Job | werty@123 | 90 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3795087.pdf
GEM_BID
wtr-pl_2022-09-15-19-47-18_6a21dbc966f9434d82af1a2bccf1111a.pdf
BOQ
ws-exl_2022-09-15-19-47-18_f99cee9a921f19101ca8dcf18755a92f.csv
BOQ
gtc.pdf
OTHER
Download all tender documents and submit your bid