Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC VILLAGE POST PATHOLI AGRA UTTAR PRADESH INDIA | L1 | Accepted-AOC Being lowest | |
| 2 | l2₹17.2 L+₹32,546 (1.92%)Rejected-Finance 208 L MODEL TOWN LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | l2 | Rejected-Finance Other than lowest | |
| 3 | L3₹17.4 L+₹49,292 (2.91%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹18.3 L+₹1.4 L (8.07%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹18.5 L+₹1.6 L (9.53%)Rejected-Finance HNO 52B LAXMI PLACE PHASE II DEORI ROAD NEAR MOHANDEV SCHOOL UKHARA ROAD AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Aug 2022, 6:00 pmClosed
Maj Vijay Kumar Sharma
Garrison Engineer West 62 Station Road Agra Cantt
REPAIRS TO LEAKAGE/SEEPAGE, ROOF TREATMENT, ETC UNDER AGE B/R-II (W) OF GE (W) AGRA
2022_MES_531921_2
8012/903/E8
Open Tender
Civil Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹60,000
25 Aug 2022
27 Jul 2022
22 Aug 2022
27 Jul 2022
19 Aug 2022
4 Aug 2022
Amount
Dismantling brick tiles in roof top laid bedded & pointed in any mortar and rubbish removing from site complete all as specified and directed.
M&L for desmantling damaged APP modified water proofing membrane and cleaning the surface by wire brush and water and removing from the site complete all as specified and directed.
Demolition of cement concrete (unreinforced) in any position n.exc 15cm thickness (below or above ground level) including removing the rubbish outside MD land complete all as specified and directed.
Dismantling of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed. Note: Removing of rubbish will be measured & paid separately.
Removing of demolished soil/materials exc 1.50 km but not exc 5 km and depositing where directed complete all as specified and directed
Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with CM 1:3 or PCC 1:2:4 type B-0 (Using 12.5mm gradedgregate) complete all as specified and directed.
M&L for cement concrete 1:2:4, type B-1 (Using 20 mm graded stone aggregate) in padding / leveling courece and similer works complete all as specified and directed.
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in coping, roof kerbs, mud stop etc and similar work including all necessary use & waste of form work complete all as specified & as directed.
M & L for water proofing treatment of roof slab complete all specified and directed. Water proofing treatment shall comprising the following : - (a) Preparation of roof surfaces by brushing, cleaning and applying a priming coat with bitumen primer @ 0.5 ltr/Sqm. (b) Applying a hot blown bitumen grade 85/25 @ 1.2 Kg/sqm (c) Laying APP modified water proofing membrane )weighing not less than 3 Kg/Sqm), 3 mm thick, reinforced with polystar non wore fabric (wt not less than 150 gms / sqm) over applied bitumen. (d) Applying a tack coat of hot bitumen grade 85/25 @ 1.2 Kg/Sqm and (e) Dusting/ blinding with sand, confirming to Zone II in dry condition @1.00 Kg/Sqm over the bitumenous teck coat.
M&L cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed.
M&L brick tiles 40 mm thick laid over 15 mm thick screed bed in CM 1:3 and jointed in CM 1:3 with linced oil @ 5% by weight of cement complete all as specified and directed.
M&L brick tiles 40 mm thick (EXCEPT BRICK TILES) laid over 15 mm thick screed bed in CM 1:3 and jointed in CM 1:3 with linced oil @ 5% by weight of cement complete all as specified and directed. Note: Old serviceable tiles recovered from item No 1 will be re-used.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed
M&L for brick work with sub class ‘B’ bricks old size (EXCEPT BRICKS), straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed but except brick. Note:- Bricks obtained from item No 13 shall be reused after cleaning.
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and smooth complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface with water proofing compound as per manufacturer's instructions by weight of cement finished fair complete all as specified and directed. Note : Water proofing compound will be measured and paid seperately under respective item of Sch ‘A’.
M & L for rendering 10mm thick in CM 1:3 on ceiling surface finished even and fair without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces and applying three coats of white wash on walls complete all as specified and directed.
M&L for preparation of new plastered or un-plastered surfaces of wall and applying two coats of cement base paint over a coat of priming paint complete all as specified and directed. (Primer & cement base to be applied by air less spray machine (mechanical means)
M & L cutting holes into or through brick wall built in cement mortar superfacial area n'exc 150 Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
Cutting the roots of trees from the brick walls/stone wall made in CM exc half and not exc one brick thick and making good the disturbed surfaces including coating of paving hot bitumen to arrest further growth to the roots including repair existing surfaces with CM 1:3 or PCC 1:2:4 complete all as specified and directed.
S & F in repair 110mm bore PVC (SWR) pipes, type 'A' single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in positionin 500 ltrs capacity hoisted and fixed in position complete all as specified & directed.
Taking up or down 20mm bore steel tubing and connection complete all as specified and directed.
S&F 20mm bore steel water tubing galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
Refixing old steel water tubing 20 mm dia with and including new GI fittings and connected to new or old positions of walls, ceilings, floors etc complete all as specified and directed.
S&F in repairs 20mm gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
S&F in repairs 500 ltrs capacity rotational moulded polyethylene water storage tank tripple layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified & directed.
S&F 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight - 210 gm) complete all as specified and directed.
S&F in repairs 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight - 210 gm) complete all as specified and directed.
Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
S&F mild steel joist, channel, angle or tee sections fixed independently with out connecting plates etcof grade fe-290 (gde E-165) complete all as specified and directed..
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed.
S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed.
M/s S. K. Construction Co.
M/S OMKAR SINGH YADAV
MESSARS JAI AMBEY BUILDERS
SHRI RADHAYSHYAM JHA
SahaDevSingh Constructions
3Krishna Enterprises
deva engineers
Asha Construction
SHANTI CONSTRUCTIONS
M/S A GUPTA AND ASSOCIATES
CREATIVE CONSTRUCTION
M/s Ram Naresh Construction Co.
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .