Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC NA | NA | NA | 121004 | ₹16.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹16.1 LRejected-Finance | ₹16.1 L | L2 | Rejected-Finance L2 |
| 3 | L3₹16.3 LRejected-Finance 1200 HOUSING BOARD COLONY SEC 15 HISAR | HISAR | HISAR | HARYANA | ₹16.3 L | L3 | Rejected-Finance L3 |
| 4 | L4₹16.3 LRejected-Finance | ₹16.3 L | L4 | Rejected-Finance L4 |
| 5 | L5₹17.2 LRejected-Finance C 46 OPP SECTOR 4 SURYA VIHAR GURUGRAM HARYANA | 2025 | ₹17.2 L | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | kunwar electricals L3 | Mandeep Singh L2 | Sudhir Gahlawat Contractor L4 | A S ELECTRIC WORKS L1 | THE DAT GREENS COOPERATIVE L AND C SOCIETY LIMITED L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | UPPLY OF 150 WATTAGE LED LIGHTS WITH 5
YEARS WARRANTY | 36 | EACH | 6,535 ₹2.4 L | 8,200 ₹3.0 L | 6,989 ₹2.5 L | 8,400 ₹3.0 L | 4,455 ₹1.6 L |
Tender Value
₹19.1 L
EMD Value
₹38,220
Closing Date
5 Feb 2026, 5:00 pmClosed
ANKIT VASHISHT
Municipal Council Rewari
Providing and fixing of 6 nos High Mast light in Sector 4, MC Rewari
2026_HRY_499542_1
20268B397C10 3A69 41E3 8686 CCAD533C05CD295ULB
Open Tender
Civil Works
75 days
Rewari
2 documents required · 2 mandatory
₹1,000
₹38,220
Yes
18 Feb 2026
29 Jan 2026
6 Feb 2026
29 Jan 2026
5 Feb 2026
29 Jan 2026
UPPLY OF 150 WATTAGE LED LIGHTS WITH 5 YEARS WARRANTY
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
HSR Item 23.22.1.9-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA HSR Rate(Rs.) 6130.00 Through Rate
HSR Item 24.5.2.4-MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia HSR Rate(Rs.) 161.00 Through Rate
HSR Item 24.1.16-EARTHING AND LIGHTENING ARRESTOR 16. Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers. HSR Rate(Rs.) 898.00 Through Rate
HSR Item 24.1.2-EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. HSR Rate(Rs.) 652.00 Through Rate
HSR Item 23.22.1.3-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.3. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in- charge of the work. TRIPLE POLE MCCB 16 to 100 Amp, 25 KA HSR Rate(Rs.) 4635.00 Through Rate
HSR Item 23.5.6.8-COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.8. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 run of Size 4 Sqmm(1/2.24mm) HSR Rate(Rs.) 234.00 Through Rate
HSR Item 24.2.4.2-LT CABLE 4.2. Laying of underground cable in pipe /existing open/closed trench etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core HSR Rate(Rs.) 13.00 Through Rate
HSR Item 24.1.1-EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. HSR Rate(Rs.) 2721.00 Through Rate
HSR Item 24.14.24-LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) HSR Rate(Rs.) 189.00 Through Rate
HSR Item 23.22.5.1-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HSR Rate(Rs.) 145.00 Through Rate
HSR Item 24.2.8.4-LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm HSR Rate(Rs.) 8.00 Through Rate
HSR Item 23.5.6.7-COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.7. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 2 run of Size 2.50 Sqmm(1.1.80mm) HSR Rate(Rs.) 168.00 Through Rate
HSR Item 23.27.5-Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 5. M.S. pedestal of size 1200 mm wide ,1500 mm high ,450 mm deep and bottom totally open , duly embeded in cement concrete block of size 1350 mm x 600 mm x 200 mm above ground level , having a base of size 1500 mm x 750 mm x 250 mm below ground level . 0 0 HSR Rate(Rs.) 12357.00 Through Rate
HSR Item 23.22.8.2-MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.2. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 100 amp 415 volts HSR Rate(Rs.) 8071.00 Through Rate
HSR Item 24.1.8-EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. HSR Rate(Rs.) 96.00 Through Rate
HSR Item 24.1.6-EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. HSR Rate(Rs.) 47.00 Through Rate
HSR Item 24.1.13-EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. HSR Rate(Rs.) 21.00 Through Rate
HSR Item 24.4.15.1-STREET LIGHT 15.1. B.S.E.N. 10025 High Masts "Supply, installation, testing and commissioning of 12.5 mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip, galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 6 nos. luminaire loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 nos. steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete in all respect upto entire satisfaction of Engineer -in-Charge Thickness of Top and Bottom Section = 3 mm (minimum) Top Dia = 150 mm and Bottom Dia = 360mm Thickness of Galvanization - Top = 65 micron (minimum) and Bottom = 85 micron (minimum)" HSR Rate(Rs.) 130343.00 Through Rate
HSR Item 24.9.1-RCC FOUNDATIONS FOR HIGH MAST OCTAGONAL POLES 1. Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 75 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for high mast octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 12.5 m high mast pole HSR Rate(Rs.) 38739.00 Through Rate
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_578125.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid