Loading…
Loading…
Tender Value
₹8.1 Cr
EMD Value
₹5.6 L
Closing Date
27 Mar 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
14 conditions · 2 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity.
Defination of Similar Work :- 1.Laying of OFC or Quad cable and supply & provision of indoor equipments like SDH or PDMUX or both. OR 2.Supply & Provision of Indoor equipments like SDH or PDMUX or both.
7 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
TENDER FORM (First Sheet) Annexure-I
ANNEXURE-V
ANNEXURE V-A
Annexure-VIB
Audited Balance Sheets duly certified by the Charted Accountant along with Annexure VI-B
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be.
Provision of Integrated Access Device (IAD) and Optic Fibre Cable (OFC) from OFC hut to Switching stations in left over areas of TP-TPJ-TJ-TVR-KIK & VM-KPD sections over TPJ Division.
T-SG-36-I-40-2025-2026
T-SG-36-I-40-2025-2026
Open
Works - General
9 Months
Chennai, Tamil Nadu
₹0
₹5.6 L
27 Mar 2026
3 Mar 2026
13 Mar 2026
30 items across 1 schedule · ₹2,35,07,864.42 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Preparation of circuits, location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall be p r e p a r e d i n A 3 / A 2 / U s i z e as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully and submit one copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways.c)Preparation of soft copy in AUTO CADD from U size hard copy | Sheet | 222.00 | 1,548.45 | 3,43,755.9 |
| 2 | Supply of Underground jelly filled 6 QUAD, 0.9MM Dia as per spec IRS:TC 30-05 with amd 5 or latest | Metre | 1000.00 | 301.05 | 3,01,050 |
| 3 | Supply o f 4 8 Fibre armoured O F C cable as per RDSO Specification RDSO/SPN/TC/110/2020 Rev. 0 or latest | Metre | 73850.00 | 126.32 | 93,28,732 |
| 4 | "Supply of OFC Patch cord (FC-PC/SC-PC/LC- PC t o FC-PC/SC-PC/LC-PC s o a s t o suit for switches and FMS supplied)" | Metre | 250.00 | 374.03 | 93,507.5 |
| 5 | Supply of UTP Cable /CAT6/6A cable ETL or UL or CE3P certified panduit or Systimax or R&M or AMP or Molex or Krone Or D-LinkMakes | Metre | 2500.00 | 34.73 | 86,825 |
| 6 | S u p p l y a n d provision o f n o r m a l j o i n t using T h e r m o s h r i n k jointing k i t ( R D S O s p e c s No TC/77/2012 ( Rev.3) with amendment No.1&2 or latest.& jointing kit to be inspected by RDSO) for 4/6 quad cable normal joint. The work includes excavation of joint pit of size 1mX1.5mX1.5m and closing the same after completion o f cable joint a s per t h e instruction o f Railway representative at site. | Numbers | 5.00 | 4,628.91 | 23,144.55 |
| 7 | Supply and installation of 48 fibre Joint enclosure f o r armoured optical fibre cable conforming to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1 or latest | Numbers | 44.00 | 20,060 | 8,82,640 |
| 8 | Supply of RCC cable markers (Supply of RCC cable markers as per drawing No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions o f Railway representative at site.) as per drawing enclosed | Numbers | 1277.00 | 262.65 | 3,35,404.05 |
| 9 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 63850.00 | 64.1 | 40,92,785 |
| 10 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming a n d consolidating i t a s p e r the instructions of Railway representative at site after l a y i n g of DWC/RCC pipes. During excavation o f trench, it has t o b e ensured that the excavated soil does not mix with the ballast available. T h e depth of 1 m trench shall b e from the bottom o f sleepers for track crossings. Laying o f cables a n d DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 500.00 | 385.45 | 1,92,725 |
| 11 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming a n d consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 500.00 | 501.03 | 2,50,515 |
| 12 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 500.00 | 208.54 | 1,04,270 |
| 13 | Fabrication and installation of MS clamps on Girder Bridges f o r t h e support o f G I pipes laid over the girder bridge | Numbers | 250.00 | 570.26 | 1,42,565 |
| 14 | Provision o f G I pipes (50/100mm dia ) for cable laying in hard rocky area with off sets at both ends duly supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall b e closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out a s per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre | 250.00 | 182.87 | 45,717.5 |
| 15 | L a y i n g o f signaling/power/ telecommunication c a b l e s a s p e r c a b l e plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f c a b l e s i s n o t included i n this schedule). | Metre | 1000.00 | 18.18 | 18,180 |
| 16 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, and consolidating t h e t r e n c h by ramming and levelling." | Metre | 63850.00 | 15.4 | 9,83,290 |
| 17 | "Digging of pit to a depth of 800mm of size 300mmX300mm, casting o f concrete foundation o f size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating i t b y ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits a n d 5 0 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing." | Numbers | 1277.00 | 123.35 | 1,57,517.95 |
| 18 | Excavation of cable coil pit to a size of 1.5mx1.5m a n d d e p t h a s i n s t r u c t e d by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. T h e work includes coiling t h e underground cables a n d placing closely o n e layer o f country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks o f size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 25.00 | 949.05 | 23,726.25 |
| 19 | " R o a d c r o s s i n g / T r a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 t o 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl of cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion o f HDPE /DWC pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe or any other combination as directed b y the site engineer) ( Supply o f HDPE pipe is not covered in this schedule)" | Metre | 1000.00 | 1,351.45 | 13,51,450 |
| 20 | Supply of Handheld True RMS Multi Meter, as per Technical specification | Numbers | 4.00 | 23,192.34 | 92,769.36 |
| 21 | Supply of Handheld True RMS clamp Meter, as per Technical specification | Numbers | 4.00 | 33,510.29 | 1,34,041.16 |
| 22 | Supply o f Handheld Digital Insulation Resistance Tester, as per Technical specification | Numbers | 4.00 | 51,165.02 | 2,04,660.08 |
| 23 | Supply of OTDR (mini) with standard accessories for 1310/1550nm with all standard accessories as per TEC specification GR/OTD-02/02 Jan 2005 or latest, ( this item should have valid TEC approval certificate) as per Technical specification | Numbers | 2.00 | 3,07,856.22 | 6,15,712.44 |
| 24 | Supply o f Laser source a n d Power meter with accessories as per Technical specification | Numbers | 4.00 | 40,710 | 1,62,840 |
| 25 | S u p p l y o f F u s i o n S p l i c i n g M a c h i n e with accessories as per Technical specification | Numbers | 2.00 | 2,95,000 | 5,90,000 |
| 26 | S u p p l y o f D o u b l e w a l l e d corrugated p i p e - 1 0 3 . 5 m m i n n e r d i a & 1 2 0 m m o u t e r dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as per Technical specification | Metre | 1000.00 | 365.19 | 3,65,190 |
| 27 | Supply of GI pipes - 50mm dia -3.65mm thick as per Technical specification | Metre | 1000.00 | 457.88 | 4,57,880 |
| 28 | Supply a n d Installation o f Wall/Rack mountable 4 8 Fibre management system (FMS) conforming to RDSO/SPN/TC- 37/2000(rev-3 amdt-1 o r latest similar to COMMSCOPE make o r better, suitable for splicing and front patching 48F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of Wooden Plank, L clamps and 4 nos of Patch cords of required length (All other materials required f o r splicing a r e to be supplied by contractor) | Numbers | 56.00 | 32,885.01 | 18,41,560.56 |
| 29 | Supply and Installation of covered 19inch Racks of size 1950mm x600mm x 600mm or higher (Make: HCL/ Vero/President/ Rittal/ Puncom or better) complete with all fittings including DC Fans (24V/48V)-2nos, separator sheet/ plate to keep testing equipment-1no and AC power distribution panel ( Horizontal fitting) with power sockets and fuse protection ( min 6 nos of 230V - 15/5A combined and other accessories | Numbers | 1.00 | 65,734.12 | 65,734.12 |
| 30 | "Excavation o f pit, casting concrete foundation and erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing one ' E ' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule). [Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required f o r t h e work shall be supplied by the Contractor]""" | Numbers | 25.00 | 8,787.04 | 2,19,676 |
| Schedule total | ₹2,35,07,864.42 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
LetterofCreditRBLr_1.pdf
ATTACHMENT
ProcedureforundertakingdiggingworkinvicinityofSignalingElectricalandTelecomcables.pdf
ATTACHMENT
NITCPROIADSNFOB_1.pdf
ATTACHMENT
40-TD-IAD-2_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .