| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 38 NEW MARKET RAWATBHATA CHITTORGARH RAJASTHAN 323305 | CHITTORGARH | RAJASTHAN | 323305 | ₹1.4 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.9 Cr+₹45.7 L (32.3%)Rejected-Finance OPP SUBHADRA HOTEL KAIGA ROAD KURNIPETH KARWAR UTTAR KANNADA 581400 | UTTARA KANNADA | KARNATAKA | 581400 | ₹1.9 Cr+₹45.7 L (32.3%) | L2 | Rejected-Finance Being L2 |
| 3 | Rejected-Technical 355 85 GALI NO 16 ASHOK VIHAR PHASE II BHIM GARH KHERI ASHOK VIHAR PHASE II GURGAON GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | - | - | Rejected-Technical Not Meeting PQ Criteria i.e. 1.1(Work experience), 2.1(Annual turnover), 2.2(Solvency or Networth), 3(EPF), 4(PAN), 5(ESI), 6.1(Electrical license), 7(b)(Appendix 3-Appendix 10), 7(c)(GST), 7(d)(Format 5), 7(e)(Appendix 4) and 7(f)(Format 4). |
| 4 | Rejected-Technical 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | - | - | Rejected-Technical Not Meeting PQ Criteria i.e. 1.1(Work experience), 2.1(Annual turnover), 2.2(Solvency or Networth), 3(EPF), 4(PAN), 5(ESI), 6.1(Electrical license), 7(b) (Appendix 3-Appendix 10), 7(c)(GST), 7(d)(Format 5), 7(f)(Format 4) and 7(g)(Appendix- 12) |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
7 Oct 2024, 5:00 pmClosed
ACE -RE
NPCIL Kaiga 5-6, Karnataka - 581 400
Supply, installation, commissioning and maintenance of Air Conditioning Systems in Construction office building at Kaiga 5-6 sites.
2024_NPCIL_207937_1
CPPP/2024/051
Open Tender
Electrical Works
Item Rate
913 days
Kaiga 5-6
Refer PQ Criteria of Tender Document
4 documents required · 4 mandatory
₹0
₹3.0 L
Office of Head CTC Kaiga Site
25 Mar 2025
16 Sept 2024
9 Oct 2024
16 Sept 2024
7 Oct 2024
27 Sept 2024
16 Sept 2024 - 24 Sept 2024
26 Sept 2024
Amount
Part-A Providing following capacity Top & side discharge (Cooling Only) Variable Refrigerant Flow (VRV/VRF) type outdoor air-conditioning system. All as per technical specifications.
Part-A 16 HP - Out door units (Top Discharge)
Part-A 28 HP - Out door units (Top Discharge)
Part-A 30 HP - Out door units (Top Discharge)
Part-A 10 HP - Out door units (Side Discharge)
Part-A Providing following capacity Ceiling suspended/ Mounted 4-way Cassette (VRF) type units. All as per technical specifications.
Part-A 1.0 TR Mini Cassette (Compact) Unit
Part-A 1.6 TR Cassette Unit
Part-A 2.0 TR Cassette Unit
Part-A 2.5 TR Cassette Unit
Part-A 3.2 TR Cassette Unit
Part-A 4.0 TR Cassette Unit
Part-A Providing VRF Hi-wall Mounted Split Type Indoor unit Capacity 2.5 Tr. All as per technical specifications.
Part-A Providing following capacity Ceiling suspended/Mounted MID STATIC ductable type unit-VRF Type. All as per technical specifications.
Part-A 2.0 TR Ductable Unit
Part-A 2.5 TR Ductable Unit
Part-A 3.2 TR Ductable Unit
Part-A Providing Refrigerant "Y" / "T" joints with insulation, suitable for the combination of indoor and outdoor machines. All as per technical specifications.
Part-A Providing DX type 2.5 TR Air-cooled Inverter driven Split type Hi-Wall AC units with ODU & IDU. All as per technical specifications.
Part-A Providing 8.5 TR Air-cooled, ducted AC unit - CSU, comprising of inverter driven compressor with ductable type indoor unit. All as per technical specifications.
Part-A Providing 34 TR capacity Double Skin Air Handling Unit for First floor lounge. All as per technical specifications.
Part-A Providing 8.5 TR condensing unit with single scroll compressor suitable for item no.8.0. Scope of work includes providing control cum starter panel including AHU kit (Expantion Valve) for AHU and condensing unit with all necessaory interlocks. All as per technical specifications.
Part-A Providing receiver kit with cordless remote hand set for ductable unit
Part-A Providing suitable following size Hard drawn liquid pipe with 19 or 13 mm thick insulation inclusive of supporting arrangment (as per system requirement). All as per technical specifications.
Part-A 6.4mm Dia, 0.8mm Thick, 21G Hard Copper Pipe (insulation 13 mm thick)
Part-A 9.5mm Dia, 0.8mm Thick, 21G Hard Copper Pipe (insulation 13 mm thick)
Part-A 12.7mm Dia, 0.8mm Thick, 21G Hard Copper Pipe (insulation 13 mm thick)
Part-A 15.9mm Dia, 1.0mm Thick, 19G Hard Copper Pipe (insulation 19 mm thick)
Part-A 19.1mm Dia, 1.0mm Thick, 19G Hard Copper Pipe (insulation 19 mm thick)
Part-A 22.2mm Dia, 1.0mm Thick, 19G Hard Copper Pipe (insulation 19 mm thick)
Part-A 25.4mm Dia, 1.0mm Thick, 19G Hard Copper Pipe (insulation 19 mm thick)
Part-A 28.6mm Dia, 1.1mm Thick, 19G Hard Copper Pipe (insulation 19 mm thick)
Part-A 31.8mm Dia, 1.1mm Thick, 19G Hard Copper Pipe (insulation 19 mm thick)
Part-A 34.9mm Dia, 1.1mm Thick, 19G Hard Copper Pipe (insulation 19 mm thick)
Part-A 38.1mm Dia, 1.35mm Thick, 19G Hard Copper Pipe (insulation 19 mm thick)
Part-A 41.3 mm Dia, 1.35mm Thick, 19G Hard Copper Pipe (insulation 19 mm thick)
Part-A Providing following size CPVC drain pipe insulated with 9mm nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest toilet drain /pantry drain/ HVAC shaft available as per site conditions and as directed by Engineer in charge.
Part-A 25 mm Dia
Part-A 32 mm Dia
Part-A 40 mm Dia
Part-A Providing 25 mm dia heavy duty, rigid PVC Conduit in the brick wall surface/roof slab by chipping the wall / concrete surface. Wherever conduit is laid (surface conduiting) over struss/ pipe to be clamped by aluminium clamp and GI nut bolt at an interval of 600mm. The scope includes supply and providing PVC moulded conduit accessories like bends, couplers, elbow, Tee, junction/ pulling boxes etc. The job shall be completed in all respect, as directed by EIC.
Part-A Providing 3 Core, 2.5 sq mm, flexible multi stranded copper Power cable for all indoor unit from power DB. All as per technical specifications.
Part-A Providing Communication cabling from Indoor unit to outdoor unit by providing PVC Conduite. All as per technical specifications.
Part-A Pressure testing, vaccumising, entire system testing and commissioning of Complete Air Conditioning of office building. All as per technical specifications.
Part-A Providing environment friendly refrigerant gas for additional top up as per system requirement. The scope shall include the cost towrads pressure testing with nitrogen Gas, Vaccumising including all consumables for all systems. All as per technical specifications.
Part-A Providing following size, 1.2 mm thick hot dip galvanized perforated Cable tray in standard length of 2500 mm with top cover. All as per technical specifications.
Part-A 300(W) X 100mm (D)
Part-A 150(W) X 100mm (D)
Part-A Providing following size GI factory fabricated and also site fabricated completely finished ducting as per site requirement. The GI ducting shall be erected at site as per drawing by providing threaded rod supports with asscociated accessories such as angle flanges, anchor fastners, GI bolts & nuts etc., All as per technical specifications.
Part-A 24G. Ducting
Part-A 22G. Ducting
Part-A 20G. Ducting
Part-A Providing 10mm thick Class "1" type, Acoustic insulation for ducts, fire retardant and moisture resistant open cell elastomeric acoustic insulation with density not less than 140 kg / m3. All as per technical specifications.
Part-A Providing 13 mm thick thermal insulation for the sheet metal duct with closed cell elastomeric insulation of Class 'O' material with density of 40 - 55 kg/cum. All as per technical specifications.
Part-A Providing collar damper - opposed blade type constructed out of extruded aluminum alloy with multiple blade of oppose blade type. Shall be used for the supply air diffuser & grilles as per the drawings & specifications.
Part-A Providing Aluminum Extruded powder coated grilles (Higher grade) with blade deflection of 0 & 15 deg. as per technical specifications.
Part-A Providing fire damper with opposed blade (Fusible Link type)- Extended Sleeve type - with 450 mm sleeve constructed with 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS. And with necessary flanges for connection as per specifications and drawings.
Part-A Providing following Rectangular duct inline fan with all accessories like fan, motor, 10 micron washable filter with frame (50mm Thick), flanges including nrcessary cabling. All as per technical specifications.
Part-A 1000 CFM, 20 mm wc.
Part-A 800 CFM, 20 mm wc.
Part-A Providing 100mm dia round flexible ducts with insulation to connect the rigid ductwork with the Terminal box diffuser without any joints. All as per technical specifications.
Part-A Supply, balancing and commissioning of factory designed and manufactured Nanosox fabric ducting and fabric shall be inherant & permanant FIRE retardant. The Nanosox Fabric Air Dispersion Systems shall be provided with ACD (Air Flow Control Device) & PAD (Air Pressure Adjustment Device) as to achieve the desired performance of the AC System. Fabric Duct Section shall be connected with each other with HEAVY duty industrial ZIPPERS & will be covered with Fabric Sleeve. All as per technical specifications.
Part-A Supply & Installation of canvas cloth for connection of ductable unit & AHU unit (1200 L x 200 H).
Part-B COMPREHNSIVE MAINTENANCE OF above Air Conditioning System (installed at Part-A) at Kaiga 5&6 office buiding:The preventive & break down maintenance of above Air Conditioning System shall be carried out for a period of 2 years by continous engaging manpower with support of requisite spares. The equipment has to be kept healthy & working condition during entire contract period by daily condition monitoring. The preventive maintenances shall be carried out once in three months & same will be considered as one operation. And break downs if any shall be attended during the entire contract period on priority. The necessay check lists for PM/BM/CM shall be arranged by the bidder. The duly filled check lists shall be submitted to the EIC/his authorised representative for verification. All as per technical specifications.
SHANMUKH ELECTRICAL WORKS (BID ID -753635)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .