Garrison Engineer Gwalior
Garrison Engineer Morar Cantt Gwalior
8703/GWL/E8 REPAIR/REPLACEMENT OF VARIOUS SIZE OF LT UG CABLE, MCCB AND COMPREHENSIVE MAINT OF E/M SERVICES AT MORAR CANTT GWALIOR
2021_MES_471885_1
8703/GWL/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
Garrison Engineer Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹90,000
Yes
29 Dec 2021
31 Aug 2021
4 Nov 2021
31 Aug 2021
28 Oct 2021
14 Oct 2021
Amount
Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed.
Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed.
Taking down unserviceable Sheet metal box & MCB DB SPN with MCB's of any make/capacity, complete, all as specified and directed by Engr-In-Charge.
M&L, concealed point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH confirming to IS 694:2010 having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area (ISI marked with valid CML No) drawn in and including concealed non metallic rigid PVC conduit medium grade( ISI marked with valid CML No) not less than 20 mm dia with all fitting and fixing accessories and 1.5 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to common earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes factory made for mounting switch, regulators etc with and including 2.8 mm thick plastic laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches. sockets etc complete for the following:-
One light point controlled by one switch.
One Ceiling fan point controlled by one switch.
One Bell/Buzzer point controlled by one way 5 Amp push button switch.
One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch.
One 3 pin/5 pin switch socket outlet, 5 Amps on independent board.
For one light point controlled by 2- two way switch
Description all as per item No 4 here in before but point wiring with 2.5 sqmm FRLSH confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire.
Description All as per item No. 04 above but surface wiring drawn in and including PVC casing caping not less than 20 mm wide complete all as specified and directed for the followings:-
One light point controlled by one switch.
One Ceiling fan point controlled by one switch.
One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch.
One 3 pin/5 pin switch socket outlet, 5 Amps on independent board.
Description all as per item No 4 here in before but point wiring with 2.5 sqmm FRLSH confirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire.
S&F switch piano, flush button, PVC/Polycarbonate, single pole one way 5 Amp complete all as specified and directed.
S&F socket out let, PVC/Polycarbonate, multipurpose, 2 in 1 5 pin, 5 Amp complete all as specified and directed.
S&F switch piano, flush button, PVC/Polycarbonate, single pole one way 15 Amp complete all as specified and directed.
S&F socket out let, PVC/Polycarbonate, multipurpose flush type, 2 in 1 6 Pin 5/15 amps complete all as specified and directed.
S&F switch piano, flush button, PVC/Polycarbonate, single pole two way 5 Amp complete all as specified and directed.
S&F bell push flush type, PVC/Polycarbonate, 5 Amps complete all as specified and directed.
S&F of buzzer Ding Dong, AC, 230 Volts, single pole complete all as specified and directed.
S&F ceiling rose surface bakelite, PVC/Polycarbonate, three terminal complete all as specified and directed.
S&F electronic step rotary type 2 module fan regulator, PVC/Polycarbonate, of two module capacity 80 to 100 Watt, 240 volts, AC 50Hz complete all as specified and directed.
S&F Lamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings non ISI Marked complete.
S&F LED Lamp 09/10 watt complete.
M&L, sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
Description all as per item No. above but for 2.5 sqmm two single core PVC insulated unsheathed FRLSH wire drawn in and including 20 mm dia PVC concealed conduit medium grade including one run single core PVC insulated unsheathed 2.5 Sqmm FRLSH earth continuty wire complete all as specified and directed.
M&L, sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC Casing Caping medium grade (ISI marked with valid CML No) not less than 25 mm in width with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor and Casing Caping shall be measured and paid as one unit .
Description all as per item No. above but for 2.5 sqmm two single core PVC insulated unsheathed FRLSH wire drawn in and including 20 mm dia PVC Casing Caping medium grade including one run single core PVC insulated unsheathed 2.5 Sqmm FRLSH earth continuty wire complete all as specified and directed.
S&F MCB DB, sheet metal enclosures double door TPN 4 way with bus bar 415 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F MCB DB, sheet metal enclosures double door SPN 12 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F MCB DB, sheet metal enclosures double door SPN 8 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F Sheet metal enclosures single pole and neutral with a two pin and earth plug and socket with and including one single pole MCB 20 amps, 240 volts, 10 KA complete all as specified and directed.
S&F in repairs MCB TPN 63 Amps, 415 volts 'C' series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed.
S&F in repairs MCB SPN 63 Amps, 240 volts 'C' series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed.
S&F in repairs MCB SP 240 volts, 63 Amps, 'C' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed.
S&F in repairs, MCB SP 240 volts, 6 to 40 Amps, 'C' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed.
Supply and Fixing in Repairs S&F Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 6500K, 50000 burning hrs fitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed.
S &F unique slimmest recess com surface panel, (Porch Light) solution to provide variable cutout size for installation in recess/ceiling mounted decorative down light square fitting with PC cover suitable and with LED 1x15 watt, 6500K complete all as specified and directed.
S&F LED luminaire 600 mm x 600 mm 36 watt 6500K, 50000 burning hrs, 220 Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling incluing connecting upto drive with reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection to connector of LED fitting including testing on completion all as specified and directed.
S & F in repairs security light fittings better optics for uniform distribution IP 65 protection LED of 30 watt, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of 40 x 5 mm FI, 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqd length of 1.5 Sqmm PVC multistranded BIS marked, 03 core copper conductor for connection from ceiling rose to light fittings incl testing on completion all as specified and directed.
Supply & Fix in repair/ replacement, of Modular Switch 6 Amp one way complete.
Supply& Fix in repair/ replacement, of Modular Switch 16 Amp one way complete.
Supply & Fix in repair/ replacement, of Modular Switch 6 Amp two way complete.
Supply& Fix in repair/ replacement, of Modular bell push 6 Amp one way complete.
Supply & Fix in repair/ replacement, of Modular socket 6 Amp 3pin complete.
Supply & Fix in repair/ replacement, of Modular socket 6/16 Amp 3pin complete.
Supply & Fix in repair/ replacement, of Modular Step fan Regulator 120 Watt complete.
Supply & Fix in repair/ replacement, of Modular white colour plate with frame 2 module complete.
Supply & Fix in repair/ replacement, of Modular white colour plate with frame 3 module complete.
Supply & Fix in repair/ replacement, of Modular white colour plate with frame 4 module complete.
Supply & Fix in repair/ replacement, of Modular white colour plate with frame 6 module complete.
Supply & Fix in repair/ replacement, of Modular white colour plate with frame 8/10/12 module complete.
Supply & Fix in repair/ replacement, of Modular metal flush box 1 & 2 module complete.
Supply& Fix in repair/ replacement, of Modular metal flush box 3 module complete.
Supply & Fix in repair/ replacement, of Modular metal flush box 4 module complete.
Supply & Fix in repair/ replacement, of Modular metal flush box 6 module complete.
Supply & Fix in repair/ replacement, of Modular metal flush box 8 to 12 module complete.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm 4 Core complete all as specified and directed.
All as per item No 52 but of size 35 Sqmm 3.5 Core
All as per item No 52 but of size 50 Sqmm 3.5 Core
S&F tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed.
Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete.
Bricks, old size sub class `B' laid in trenches with width wise along the alignment of the cable as protection complete.
Excavation in trenches n exc. 1.5 m wide and n' exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete.
S&F 4 Pole MCCB 350 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified.
S&F 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified.
S&F 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified.
M&L for in repairs, servicing including replacement of any defective parts of Three Phase input supply, three phase output, PWM technology IGBT based, ON_LINE UPS with back up support time of 30 minutes on full load, inclusive of standard maintenance free(SMF) batteries bank with features of feather touch buttons switches and By Pass arrangement facility for emergency operation, with auto change over and protection in case of High and Low voltage, Single phasing etc of capacity 5 KVA including replacement of old burnt MCB of 32 Amps SPN complete all as specified and directed.
M & L for servicing of Diesel driven Engine & water pump of 60 HP capacity including replacement of all consumable parts i.e engine oil, spinion lube oild filter, Fuel filter element primary, fuel filter element secondary, primary element for KFA- 01-7221, Coolent premix in 10 Ltr cane and all other essential parts required such as fuel level indicator, lub oil pressure sensor, temperature sensor, overload sensor and all other sensors and gauges with soft touch buttons at site, replacement of unsv leads required for battery, complete checking and replacing (if unsv) any other parts of Diesel driven Pump set as and when required or as per direction of Engr-in-Charge. .
M & L for Dismantling / taking down of electric motor of centrifugal pump 60 HP, AC, 3 phase, 415 volts from site after disconnecting from pump & electric connection for rewinding, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, and reassembling after repairs and replacement of parts as required, end plates, coupler pulley, cooling fan and terminal blocks etc and refixing the same at site incl. electric connections , install, testing and commissioning for satisfatory function as and when required or as directed by Engineer - in - charge.
M & L for Dismantling / taking down of electric motor of jockey pump of 15 HP, AC, 3 phase, 415 volts from site after disconnecting from pump & electric connection for rewinding, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, and reassembling after repairs and replacement of parts as required, end plates, coupler pulley, cooling fan and terminal blocks etc and refixing the same at site incl. electric connections , install, testing and commissioning for satisfatory function as and when required or as directed by Engineer - in - charge.
S & F in repairs of any type and capacity of unsv starter (as per sample and installed in Fire pump house/water supply pump house) in existing LT Panel including making necessary electrical connection and testing on completion incl taking down old unsv one as and when required or as directed by Engr-in-Charge.
S&F Battery 12 V, 150 AH for UPS complete all as per specified.
S&F Battery 12 V, 180 AH for Diesel Engine 60HP complete all as per specified.
M&L for in repairs/ Maintenance & servicing including replacement of any defective parts of Shadow Less Light and its controller switchs, installed at MH OT complete all as specified and directed by Engineer in Charge.
M&L for in repairs/ Maintenance & servicing & Over Hauling, including replacement of any defective parts of Medical Gas Controller complete all as specified and directed by Engineer in Charge.
M&L for Shifting & repairs/ Maintenance & servicing including replacement of any defective parts of Split AC Upto 2 TR, including Gas filling (If required), installed at MH & MDC area complete all as specified and directed by Engineer in Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in 'D' shape 500 mm legth grouted in wall complete 01 x 6 mm multistrand PVC insulated copper conductor ( Green Colour) to be provided from test point to DB through 20 mm dia concealed non metallic conduit complete all as specified and directed.
Supply & Fix in replacement of old unserviceable Fire Fighting Hose Pipe as per existing size and dia complete all as Specified and directed.
Supply & Fix in replacement of old unserviceable Fire direction light as per existing size and type complete all as Specified and directed.
Supply & Fix in replacement of old unserviceable Smoke detector as per existing size and type complete all as Specified and directed.
Supply & Fix in replacement of old unserviceable Photo control sensor switch for automatic security light control out door type, 220 volts, 10 amps capacity complete all as specified and directed.
Comprehensive maintenance including repairs and routine maintenance of microprocesser controlled VVV frequency drive electric driven passenger lift - 02 Nos of 884kg carrying 13 passenger with ARD facility from ground plus two floors consisting of examing, adjusting, lubricating, greasing the parts including replacement of minor parts such as relays, Rectifier and Indication display, Main Contactor transformer, Brake liner and Gear oil, Motor Oil and servicing, Gate lock switches Gate levers, Gate beaks, Gate track rollers, contact switches and limit switches, Floor level indication switch and oscillator switch, Car counter weight shoes and door and Gate Shoes, Pit switch and safety switches, landing floor indicator, car bush buttons and switches and Car indicators, Emergency Alarm Buttons, Up & down indicator cards, Aluminium Brackets,OSG roller and lubrication, Guide lubrication, servicing of auto door, Track rollers, and linking rolls, Door locks contact, Door lubrication and oiling of OSG rope, OSG clips and ,Main rope clips, Rope tension spring, OSG safety switch, Door opening buzzer, stop button, door stopper, car & landing door, door opening and closing belt, Door limit switches all as specified by the Engr-inCharge to be replaced and if any connected items missing for satisfactory operation of lift will be assumed included as the rate quoted against this item rate. The schedule item operated all as specified and as directed by Engr-in-Charge. (Note :- 1. Necessary servicing of lift as per manufacturers instruction shall be carried out be contractor from authorised rep of manufacturer.) 2. The period will be start from 11 Nov 2021 to next 6 month).
Comprehensive maintenance including repairs and routine maintenance of microprocesser controlled VVV frequency drive electric driven passenger lift - of 1020kg carrying 15 passenger with ARD facility from ground plus two floors consisting of examing, adjusting, lubricating, greasing the parts including replacement of minor parts such as relays, Rectifier and Indication display, Main Contactor transformer, Brake liner and Gear oil, Motor Oil and servicing, Gate lock switches Gate levers, Gate beaks, Gate track rollers, contact switches and limit switches, Floor level indication switch and oscillator switch, Car counter weight shoes and door and Gate Shoes, Pit switch and safety switches, landing floor indicator, car bush buttons and switches and Car indicators, Emergency Alarm Buttons, Up & down indicator cards, Aluminium Brackets,OSG roller and lubrication, Guide lubrication, servicing of auto door, Track rollers, and linking rolls, Door locks contact, Door lubrication and oiling of OSG rope, OSG clips and ,Main rope clips, Rope tension spring, OSG safety switch, Door opening buzzer, stop button, door stopper, car & landing door, door opening and closing belt, Door limit switches all as specified by the Engr-inCharge to be replaced and if any connected items missing for satisfactory operation of lift will be assumed included as the rate quoted against this item rate. The schedule item operated all as specified and as directed by Engr-in-Charge. (Note :- 1. Necessary servicing of lift as per manufacturers instruction shall be carried out be contractor from authorised rep of manufacturer.) 2. The period will be start from 11 Nov 2021 to next 6 month).
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
M&L for sand cushioning in trenches for cable protection including consolidation complete all as directed.
M&L for Sub class 'B' bricks laid dry width wise across the line of cable in treanchs as cable protection complete all as specified and directed by engr in charge.
M & L in replacement of MCCBs 125 Amps, 415 volts, 3 pole rupturing capacity 16 KA in existing panel including making existing electrical connection as per existing system all as specified and directed.
M & L in replacement of MCCBs 160 Amps, 415 volts, 3 pole rupturing capacity 25 KA in existing panel including making existing electrical connection as per existing system all as specified and directed.
M & L in replacement of MCCBs 200 Amps, 415 volts, 3 pole rupturing capacity 25 KA in existing panel including making existing electrical connection as per existing system all as specified and directed.
M & L for GI Pipe light grade complete with fittings laid in floor/ trenches/ wall as cable protection of 100 mm dia all as specified and directed.
All as per item No 87 but size 80 mm dia.
Supply, laying, jointing and testing, XLPE insulated, armoured,heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade, of size 3.5 core 120 Sqmm
All as per item No 89 but 95 Sqmm 3.5 core.
All as per item No 89 but 70 Sqmm 3.5 core.
All as per item No 89 but 50 Sqmm 3.5 core.
All as per item No 89 but 35 Sqmm 3.5 core.
All as per item No 89 but 25 Sqmm 4 core.
Boring of holes under road, pavement, hard standing by trenches technology using ultra sound technique and necessary machine including HDPE pipe of 100mm dia suitable for 0.4 mpa working pressure.
Taking down existing old US XLPE UG cable of size upto 25 Sqmm x 4 Core.
Taking down old unserviceable street light fitting from pole alongwith accessories and deposited to MES Yard all as specified and as directed by Engr-in-Charge.
Supply and fixing XLPE insulated heavy duty Aerial bunched cable aluminium conductor as per IS 7098 PT-2/IEC-60502/IS-14255 with necessary crimping arrangement with existing pole of size 3 x 25 + 1 x 16 + 1 x 16 Core.
Supply and fixing dead end clamp suitable for hanging AB conductor.
Supply and fixing suspension clamp, eye hook and pole clamp suitable for hanging AB conductor.
Supply and fixing insulation puncturing of conductor suitable for AB Conductor.
Supply and fixing LED street light fittings of 72 watt made out of die cast Al housing with high power LED having IP 66 protection with optical compartment with heat resistant toughned glass and control gear shal be die cast Al cover for safety. LEDs used in street lights should be 5700K and CRI of 50000 hrs with clear lenses and driver suitable to operate input voltage range between 150 volt to 270 volts with min 3 KV surge protoction and PF should be greater than .95 including required size and length of Copper multistranded conductor for electrical connection and required size of GI bracket all as specified and directed.
M&L for reinforced concrete pipes of dia 150mm , class NP2 laid and jointed complete with collars all as specified and directed by Engr-in-charge.
S & F Junction box for mounting on tublar pole including FI clamps, nut, bolt & washers mtrl etc complete all as specified and directed.
S&F aluminium tube terminal heavy duty-BS-4579 for following sizes :
tanay enterprises
M/s. Varinder Kumar Sharma
M/s Tirupati construction
mahamaya constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .