Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹37.5 L
EMD Value
₹74,900
Closing Date
4 Dec 2026, 11:00 am
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
56 conditions · 11 needing a document upload
The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. . Necessary documents to this effect as applicable,
Electrical License as per tender conditions.
In case of other than company/proprietary firm , annexure V (A) shall also be submitted by each member of a partnership firm/ Joint Venture(JV)/Hindu United Family (HUF)/ Limited liability partnership(LLP) etc., as the case maybe. Non submission of above certificate(s) by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document
Power of attorney duly stamped and authenticated by a Notary Public or by Magistrate as per Tender conditions.
The tenderers are advised to download and carefully read the Tender Document attached with this Notice Inviting tender.
Tenderers are advised to submit all the documents required to be uploaded by them in Kannada/Hindi/English. Documents uploaded in any other language shall be translated to Kannada/Hindi/English and attested copy may be uploaded for better appreciation of the tender.
Mandatory documents that are to be uploaded without which the bid will be summarily rejected are mentioned in Chapter II of the Tender Document attached with this Notice Inviting Tender
CORRIGENDUM NOTICE ON IREPS: Railway may modify the tender document by issuing online corrigendum through "www.ireps.gov.in" 15 days prior to the tender closing date. For the purpose of CORRIGENDUM in the tender, NIT period is split as under: (a) ADVERTISEMENT PERIOD: The time during which all information pertaining to tender shall be available but offers cannot be submitted (b) OFFER SUBMISSION PERIOD: 15 days prior to closing of tender, during which tenderers can submit their offer
The tenderers are advised to carefully read this tender Document (Chapter I to IV) in conjunction with Indian Railways Standard General Conditions of Contract- April 2022 with latest amendments and correction slips before participating in this Tender.
The rates quoted for the relevant supply items of work shall include the cost of materials and their accessories. Similarly, for fixing/installation/erection/ Testing and Commissioning item of work shall include the cost of labour, together with the cost of providing the necessary tools and tackles etc., so as to ensure that the work carried out forms a complete supply, installation,Testing, commissioning of item work to the satisfaction of the Engineer-in-charge.
The prices quoted shall be net including all taxes and duties etc.
Documents to be Submitted Along with Tender (i)The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / HUF etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case maybe. (ii)Following documents shall be submitted by the tenderer: (a)Sole Proprietorship Firm:
Following documents shall be submitted by the tenderer: if HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF.
Following documents shall be submitted by the tenderer: if Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. Note: Mandatory only for whom it is applicable.
Following documents shall be submitted by the tenderer: if LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract.
Following documents shall be submitted by the tenderer: if Registered Society & Registered Trust: The tenderer shall submit: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society. Note: Mandatory only for whom it is applicable.
The following documents shall be submitted by the partnership firm, with the tender: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract. Note: Mandatory only for whom it is applicable.
The tenderers are advised to upload all required documents mentioned in this Notice Inviting Tender as well as in the Tender Document (Tender forms)(Chapter I to IV) along with the bid.
The schedule given in this NIT shall be read in conjunction with technical specifications/ explanatory notes and drawings given in the Tender document attached with this Tender
Upload duly filled & signed copy of "NEFT Declaration form". (please download the format from attached documents)
Partnership Deeds, Power Of Attorney Etc.: The tenderer shall clearly specify whether the tender is submitted on his/her own or on behalf of a partnership concern. If the tender is submitted on behalf of a partnership concern, he/she should upload the certified copy of partnership deed along with the tender and authorization to sign the tender documents on behalf of partnership firm. The Railway will not be bound by any power of attorney granted by the tenderer or by changes in the composition of the firm made subsequent to the execution of the contract. It may, however, recognize such power of attorney and changes after obtaining proper legal advice, the cost of which will be chargeable to the contractor. Note: Mandatory only for whom it is applicable.
The tenderer whether sole proprietor, a limited company or a partnership firm if they want to act through agent or individual partner s should submit along with the tender , a power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/she/they be partner(s) of the firm or any other person specifically authorizing him/her/them to submit the tender and other tender related activities till completion of the work including signing No Claim Certificate and refer all or any disputes to arbitration. Note: Mandatory only for whom it is applicable.
The tenderer whether sole proprietor, a limited company or a partnership firm if they want to act through agent or individual partner s shall submit a power of attorney at a later stage duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner s of the firm or any other person specifically authorizing him/them to sign the agreement, witness measurements, sign measurement books, to sign contract correspondence, signing the bills etc. the GPA shall be accepted after obtaining Legal advise from LAW branch/ Hubballi division. Note: Mandatory only for whom it is applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Upload the CLEAR COPY of GST Registration particulars
Electrical arrangements to Provision of New Running Room at Kudgi with 24 rooms/48 beds.
HE-14-2026-27SL01~SWR
HE-14-2026-27SL01
Open
Works - General
6 Months
Dharwad, Karnataka
₹0
₹74,900
11 Nov 2026
11 Nov 2026
20 Nov 2026
139 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 37,45,092.2 | ||
| — | 300.00 | — | — | ||
| Excavation in trenches in any kind of soil of required width for LT/HT UG cables, foundations, including excavation for joints, and dressing of sides, ramming of bottoms, depth up to 1.5 m as directed at site, including getting out the excavated soil, and then returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing off surplus excavated soil as directed, within a lead of 50 mtrs from the starting point. | — | — | — | 60,564 | |
| — | 1000.00 | — | — | ||
| Supply of high density polyethylene pipe (HDPE pipe) of size50 mm (nominal dia) category of PE-80, PN-6 along withaccessories (T joint / straight coupler etc.), ISI marked fordrawing LT cables all as per specification. | — | — | — | 54,970 | |
| — | 1000.00 | — | — | ||
| Laying of high density polyethylene pipe (HDPE pipe) of size 50 mm (nominal dia) category of PE-80, PN-6 along with accessories (T joint / straight coupler etc.), ISI marked and drawing LT cables all as per specification. | — | — | — | 6,100 | |
| — | 1000.00 | — | — | ||
| Transportation, Laying, testing and commissioning of LTUG cable 4cx16 / 4cx25 / 4cx35 / 4cx50 sqmm as per specification. Note:- LT UG cable will be issued by Railways. The contractor will be responsible for collection of cables from the Elect Maintenance / Works Depot including loading, unloading, transportation and return of un-used cables back at Depot. Costs of these provisions are deemed to be included in the quoted rates. | — | — | — | 17,300 | |
| — | 6.00 | — | — | ||
| Supply and making end termination with brass compression gland and aluminium lugs for 4 x 50 sqmm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as specified and directed. | — | — | — | 2,508 | |
| — | 10.00 | — | — | ||
| Supply and making water / moisture proof end termination with brass compression gland and aluminium lugs for 25 Sqmm size, 4 core of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as specified and directed. | — | — | — | 3,150 | |
| — | 16.00 | — | — | ||
| Supply and making water / moisture proof end termination with brass compression gland and aluminium lugs for 16 Sqmm size, 4 core PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as specified and directed. | — | — | — | 4,944 | |
| — | 1.00 | — | — | ||
| Design, fabrication, supply, fixing, connecting, testing and commissioning of LT Control Panel, cubical type, 250 A, 3 phase 4 wire system with copper bus bars of size 30 x 10 mm, outdoor opening from both front and rear sides, separate compartments for each control gear, cable alley and provision of knock out type entry plates suitable up to 185 sqmm size cables, panel made out of 2 mm thick CRCA sheet, epoxy powder coated with grey matt finish , including base frame made out of 50 x 50 x 6 mm angle iron sections, embedded in PCC 1:3:6 foundation, consisting of the following switchgears and metering devivces:- (i) MCCB 250 A, 4P, 36 KA, with electronic microprocessor release - 01 No (ii) MCCB 100 A, 4P, 36 KA, with electronic microprocessor release - 02 Nos (iii) MCB 63 A, TPN, 10 KA, - 06 Nos (iv) MCB 5-32A, DP, 10 KA - 06 Nos (iv) On Load COS 250A -01 No. Multi-function 3 phase meters reading V, I, W, KVA, PFHz etc, including CTs, pilot lamps complete all as specified and directed. | — | — | — | 1,63,264 | |
| — | 4.00 | — | — | ||
| Fabrication, supply and erection of 6 Mtrs long hot dip galvanized octogonal pole with BSEN 10025 grade S355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, backelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for 6 m pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom 130 mm, top 70 mm with 3 mm thick suitable base plate and 4 Nos foundation bolts, necessary excavation for foundation and refilling all as specified and directed (excluding PCC foundation). | — | — | — | 47,200 | |
| — | 4.00 | — | — | ||
| Supply and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts, clamps etc., complete-Double Arm Bracket with 1500 mm Standard 40/50 mm dia. | — | — | — | 6,800 | |
| — | 8.00 | — | — | ||
| Supply and fixing of 70 W, LED flood light fitting on walls/pillars including all necessary fixing arrangements such as clamps, nuts, bolts etc; as per site requirement and as per detailed tender / SWR specification. | — | — | — | 47,936 | |
| — | 1.50 | — | — | ||
| Providing and making steel pole foundation / collar with cement concrete (1:3:6) with stone aggregate 20 mm nominal size in foundations of specified size and shape including form work, plastering if required, curing etc as required. (Volume of pole /pipe not to be deducted). | — | — | — | 12,202.5 | |
| — | 6.00 | — | — | ||
| Supply and embedding 40 mm dia GI pipe, medium class, in pole collar / foundation (During casting) for cable entry including bending the pipe to the required shape complete as required. | — | — | — | 3,534 | |
| — | 30.00 | — | — | ||
| Supply and drawing 3 x 1.5 sq mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ PVC conduit as required. | — | — | — | 4,110 | |
| — | 6.00 | — | — | ||
| Material and labour for earthing with GI earth plate 600mm x 600 mm x 6 mm thick including accessories, and providing msonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc with charcoal / coke and salt as required all as specified and directed. | — | — | — | 44,832 | |
| — | 120.00 | — | — | ||
| Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc as required. | — | — | — | 29,280 | |
| — | 3.00 | — | — | ||
| Supply and fixing of 6 way (4 + 18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. | — | — | — | 14,922 | |
| — | 12.00 | — | — | ||
| Supply and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. | — | — | — | 27,780 | |
| — | 3.00 | — | — | ||
| Supply and fixing 50 A to 63 A rating, 415 V, 10 kA, "C" curve, TPN miniature circuit breaker suitable for inductive load of in the existing MCB DB complete with connections, testing and commissioning etc. as required. | — | — | — | 9,264 | |
| — | 3.00 | — | — | ||
| Supply and fixing 63 A, triple pole and neutral 415 V, residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. | — | — | — | 8,616 | |
| — | 69.00 | — | — | ||
| Supply and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, Double pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | — | — | — | 45,264 | |
| — | 48.00 | — | — | ||
| Supply and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, Single pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | — | — | — | 12,288 | |
| — | 1300.00 | — | — | ||
| Wiring for circuit/ submain wiring alongwith earth wire with the size of 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit including all necessary connected works such as cutting chases, drilling holes on wall / ceiling etc including plastering / making good the disturbed surfaces all as specified and as directed. | — | — | — | 3,57,500 | |
| — | 700.00 | — | — | ||
| Wiring for circuit/ submain wiring alongwith earth wire with the size of 2 X 4 sq. mm + 1 X 4 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit including all necessary connected works such as cutting chases, drilling holes on wall / ceiling etc including plastering / making good the disturbed surfaces all as specified and as directed. | — | — | — | 2,33,800 | |
| — | 600.00 | — | — | ||
| Wiring for circuit/ submain wiring alongwith earth wire with the size of 2 X 6 sq. mm + 1 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit including all necessary connected works such as cutting chases, drilling holes on wall / ceiling etc including plastering / making good the disturbed surfaces all as specified and as directed. | — | — | — | 2,63,400 | |
| — | 363.00 | — | — | ||
| Material and labour for point wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required including all necessary connected works such as cutting chases, drilling holes on wall / ceiling etc including plastering / making good the disturbed urfaces all as specified and as directed. Note: Surface wiring shall be opted only where recessed wiring is not feasible and as per the direction / approval of the Engr-In- Charge. | — | — | — | 3,68,445 | |
| — | 70.00 | — | — | ||
| Supply of 20/22 W LED Batten fitting, 240 V AC with diffuser and driver including all connected materials all as per detailed tender / SWR specification. | — | — | — | 48,300 | |
| — | 50.00 | — | — | ||
| Supply only indoor type LED modular down light 25/30 W, 1 foot x 1 foot, recess/surface mounted, all as per detailed tender / SWR technical specifications. | — | — | — | 1,84,600 | |
| — | 25.00 | — | — | ||
| Supply only indoor type LED modular down light 36 W, 2 feet x 2 feet Recess/Surface mounted all as per detailed tender / SWR technical specifications. | — | — | — | 1,13,825 | |
| — | 28.00 | — | — | ||
| Supply only 6 W LED mirror light fitting and with driver suitable for 230 V, 50 Hz AC, of approved make all as per detailed tender / SWR specification. | — | — | — | 38,478.16 | |
| — | 24.00 | — | — | ||
| Supply only 3 W LED Decorative night light fitting with lence and driver suitable use on 230 V, 50 Hz ACall as per detailed tender / SWR specification. | — | — | — | 33,642.48 | |
| — | 48.00 | — | — | ||
| Supply only 3 W LED reading light fitting with flexible rod for up & down with switch suitable use on 230 V, 50 Hz AC supply all as per detailed tender / SWR specification. | — | — | — | 41,317.92 | |
| — | 24.00 | — | — | ||
| Supply only 3 Modular LED Foot lamp suitable for 230 V, 50 Hz AC all as per detailed tender / SWR specification. | — | — | — | 8,080.32 | |
| — | 269.00 | — | — | ||
| Fixing all types and all capacities of LED fittings indoor on the wall / ceiling /rafters/girders using twin twisted PVC insulated copper wires, required number of round blocks and clamps all as specified and directed. | — | — | — | 32,818 | |
| — | 150.00 | — | — | ||
| Supply, fixing & testing of LED Strip Light IP 64 warm/white, 8W/mtr including supply and fixing of driver unit, aluminium profile with cover and all connecting accessories and labour etc. | — | — | — | 77,700 | |
| — | 36.00 | — | — | ||
| Supply only BLDC ceiling fans, working on 230 V AC, 50 Hz of Sweep size 1200 MM all as per detailed technical specification and all as directed. | — | — | — | 96,372 | |
| — | 36.00 | — | — | ||
| Fixing only BLDC ceiling fans, working on 230 V AC, 50 Hz of Sweep size1200 MM all as per detailed technical specification including provision of necessary fan hooks, down rods of required length, canopies, clamps and connection with PVC insulated twin twisted wire of approved quality etc as required at site all as directed. | — | — | — | 11,340 | |
| — | 28.00 | — | — | ||
| Supply only BLDC Exhaust fan 200 mm sweep, single phase AC 230 V, 50 Hz modular type complete with all accessories such as frame with louvers, all as per detailed tender specifications and as directed. | — | — | — | 51,685.2 | |
| — | 28.00 | — | — | ||
| Fixing of BLDC Exhaust fan 200 mm sweep, single phase AC 230 V, 50 Hz modular type complete with all accessories such as frame with louvers, necessary mounting arrangements, nuts bolts, fasteners including making suitable openings on walls, making good and finishing the disturbed wall surfaces etc all as per detailed tender specifications and as directed. | — | — | — | 5,742.8 | |
| — | 24.00 | — | — | ||
| Supply and fixing of Electronics bulbul bell bird chime Call bell similar to anchor model No.8432 including provision 2 Module GI box with cover plate with frame including connection fixing of call bell with all connected materials and works. | — | — | — | 9,132.96 | |
| — | 6.00 | — | — | ||
| Supply of 70 W, LED flood light fitting on walls / pillars including all necessary fixing arrangements such as clamps, nuts, bolts etc, as per site requirement and as per detailed specification. | — | — | — | 40,608 | |
| — | 6.00 | — | — | ||
| Fixing LED flood light fitting over existing pole / wall, ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | — | — | — | 972 | |
| — | 363.00 | — | — | ||
| Supply & fixing 3 pin 5A ceiling rose on the existing junction box / wooden block including connections etc, as required. | — | — | — | 31,581 | |
| — | 40.00 | — | — | ||
| Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | — | — | — | 19,080 | |
| — | 110.00 | — | — | ||
| Supply and fixing 3 pin 5/6 A modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc as required. | — | — | — | 13,420 | |
| — | 110.00 | — | — | ||
| Supply and fixing 5/6 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc as required. | — | — | — | 11,330 | |
| — | 30.00 | — | — | ||
| Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | — | — | — | 17,580 | |
| — | 30.00 | — | — | ||
| Supply and fixing 6 pin 15/16 A modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc as required. | — | — | — | 5,910 | |
| — | 30.00 | — | — | ||
| Supply and fixing 15/16 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc as required. | — | — | — | 4,680 | |
| — | 30.00 | — | — | ||
| Supply & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB "C" curve including connections, painting etc as required. | — | — | — | 21,810 | |
| — | 28.00 | — | — | ||
| Fixing only split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 Ton split type A/C. Note:- Split type Air conditioners will be issued by Railways from the store Depot of SSE/E/Works/UBL. Collection and transportation to site is the responsibility of contractor. Cost of this provision is deemed to be included in the quoted rates. | — | — | — | 88,900 | |
| — | 84.00 | — | — | ||
| Supply and fixing of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube. | — | — | — | 1,30,116 | |
| — | 28.00 | — | — | ||
| Supply and fixing of voltage stabilizer suitable for 1 /1.5 Ton AC, Working voltage : 170 V to 270 V, 12 Amps, Time delay : ITDS 3 Min+ 20 sec with thermal overload protection and high voltage cut-off all as per detailed technical specifications. | — | — | — | 57,349.04 | |
| — | 26.00 | — | — | ||
| Supply only Electric Water heater 25 Ltrs Cap Sationary type ( 5 Star ), 2 KW Closed / Vented type Geyser with all connected materials and works all as per detailed tender specifications. | — | — | — | 2,66,292 | |
| — | 26.00 | — | — | ||
| Fixing including electrical & water connections and testing of 25 ltrs capacity wall mounting type electric geysers using suitable fastener bolts including necessary connection cord with 15A 3 pin top. | — | — | — | 17,264 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of 500 LPD capacity solar water Heating system comprising of all fittings and fixtures all as per detailed tender specifications. | — | — | — | 1,31,670 | |
| — | 6.00 | — | — | ||
| Supply and fixing of LED Bollard light fitting of 8 W, 1 mtr height with pressure die cast aluminium housing body for optimal thermal dissipation with all connecting materials and works as specified in the tender document. | — | — | — | 27,173.7 | |
| — | 12.00 | — | — | ||
| Supply and fixing 32 A security and energy saving DP switch with key tag suitable to operate on 230 V 50 Hz AC supply & completely wired on existing box. | — | — | — | 7,752 | |
| — | 2.00 | — | — | ||
| Supply and provision of Water cooler (Non CFC Refrigerant) Energy Efficient, Compressor, 80 Ltrs /Hrs cooling Cap, Type - storage Cap. 150 Ltrs. Rate of Max. Energy comsuption Watts- 1000, with all connected materials and works all as per detailed tender specifications. | — | — | — | 1,16,000 | |
| — | 2.00 | — | — | ||
| Supply & fixing LED, 230 V AC, 25 W pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr Compatible for pole mounting with outer dia of 40 mm to 65 mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598 all as specified and as directed. | — | — | — | 13,844 | |
| — | 2.00 | — | — | ||
| Supply of Electrically driven bore well submersible pump set of 1) capacity :5 HP/3.7 KW 2) Phase3 phase, 415 V 3) Bore size : 150 mm 4) Stage: 12 5) Water discharge : minimum 90 LPm at 110 Mtrs head, 6) Input/Out put GI pipe 50 (2") mm 7) Rating :- 5 star 8) warranty :- Minimum 1 year 9) Approved make:- MBH, kirloskar, V-guard, Lubi, Texmo, aquatex,l waterman, Polad PSG, CRI only. | — | — | — | 56,089.46 | |
| — | 30.00 | — | — | ||
| Supply & Erection of High tensile heavy duty 50 mm dia UPVC pipe for submersible pump suitable for 20 Kg/sqcm capacity of 3 mtr length each. | — | — | — | 24,622.2 | |
| — | 2.00 | — | — | ||
| Supply of Cast iron adopter set suitable for 50 dia submersible column pipe. Make: ashirwad. | — | — | — | 2,647.86 | |
| — | 1.00 | — | — | ||
| Out door type DOL starter control panel for 5 HP submersible pump set as per detailed tender specification. | — | — | — | 14,554.77 | |
| — | 150.00 | — | — | ||
| Supply of 2.5 sq.mm PVC Sheathed industrial 3 core flat submersible cable for submersible pump motors with voltage grade upto 1100 Volts as per IS:694 Make:- poly cab, Finolex, V-guard or similar. | — | — | — | 7,068 | |
| — | 1.00 | — | — | ||
| Supply of GM non return valve heavy duty 50 MM dia, 4 inch long, ISI marked all as per detailed tender specifications. | — | — | — | 2,595.09 | |
| — | 1.00 | — | — | ||
| Supply of GM sluice valve heavy duty, 50 mm size with ISI mark all as perdetailed tender specifications. | — | — | — | 2,542.33 | |
| — | 1.00 | — | — | ||
| Supply and fixing of all misc items like 1) MS bore clamp of 12 mm thickness suitable for 50 MM GI pipe =2 Nos 2) GI Bend -50 MM dia =1 No. 3) Bore well Cover | — | — | — | 1,217.45 | |
| — | 1.00 | — | — | ||
| Labour and T&P required for erection, testing and commissiong of submersible pump set, electrical & water connection, control panel including transportation of Pumping machinery complete all as specified and directed. | — | — | — | 7,414.96 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
JPOforcablecuttings1.pdf
ATTACHMENT
NEFTForm.pdf
ATTACHMENT
ANNEXURE-VAFFIDAVIT.pdf
ATTACHMENT
2018_CE-I_CT_9Date04_06_2018LOCLETTEROFCREDIT.pdf
ATTACHMENT
Advancecorrectionslip1to11.pdf
ATTACHMENT
AdvanceCorrectionSlipNo12toGCC2022.pdf
ATTACHMENT
Tenderform-Works.pdf
ATTACHMENT
DECLARATIONONRETIREDRAILWAYOFFICERS.pdf
ATTACHMENT
N_6599_1794394973597.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .