| 1 | L1₹33.5 LAccepted-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.2 L+₹1.7 L (4.99%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance L2 | |
| 3 | L3₹36.3 L+₹1.8 L (5.18%)Rejected-Finance VILLAGE CHANNI POST OFFICE SATTANI DISTT UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance L3 | |
| 4 | L4₹36.3 L+₹1.8 L (5.33%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹39.0 L+₹4.5 L (13.1%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
13 Oct 2022, 6:00 pmClosed
GE AF UDHAMPUR
GE AF UDHAMPUR
SPECIAL REPAIR TO CERTAIN AIRMEN BILLETS AT AF STATION UDHAMPUR
2022_MES_552564_1
GE/AFU-43/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE AF Udhampur
as per tender documents
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹82,000
Yes
22 Nov 2022
17 Sept 2022
15 Oct 2022
17 Sept 2022
13 Oct 2022
1 Oct 2022
17 Sept 2022 - 17 Sept 2022
Amount
SCH A PART-I (E/MWORKS)
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and LT cable and getting out, , complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge
Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed by Engineer-in-Charge
Dry sand cushioning to under ground cable all as per clause 19.75 of SSR Part - I laid before and after laying of cable, complete all as specified and directed by Engineer-in-Charge
Sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable in repair , complete all as specified and directed by Engineer-in-Charge
Taking down carefully aluminum/copper point wiring (light/ fan/socket or power) complete with fittings such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCBs, Main switches from control board and making good disturbed surfaces of walls, floor to match with existing specificationscomplete all as specified and directed by Engineer-in-Charge
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Description all as per serial item No.1.07 here-in-before but 2 way point controlled by two switches complete all as specified and directed by Engineer-in-Charge
Description all as per serial item No.1.07 here-in-before but for one 6 Amps socket outlet on the same board complete all as specified and directed by Engineer-in-Charge
Description all as per serial item No.1.07 here-in-before but for one 6 Amps socket outlet on the Independent board complete all as specified and directed by Engineer-in-Charge
Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified and directed by Engineer-in-Charge Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Supply and fixing Switch piano type single pole , one way 6 Amps IS-3854 complete all as specified and directed by Engineer-in-Charge
Supply and fixing of Switch type 16 AMP,two way , one module conforming to IS-3854 complete all as specified and directed by Engineer-in-Charge
Suply and fixing of Switch socket combination 5 in 1, 16 Amp flush type universal type, conforming to IS-3854 complete all as specified and directed by Engineer-in-Charge.
Suply and fixing of Switch 16 Amp 2 Way flush type universal type, conforming to IS-3854 complete all as specified and directed by Engineer-in-Charge.
Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and directed by Engineer-in-Charge
Lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and directed by Engineer-in-Charge
supply and fixing of steped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. As requied complete all as specified and directed by Engineer-in-Charge.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and directed by Engineer-in-Charge. Note: Total three run cable measures as one run ie. Two runs each of one RM of 6.00 sqmm main cable and one RM of 6.00 sqmm cable earth wire together including conduit shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and directed by Engineer-in-Charge. Note: Total three run cable measures as one run ie. Two runs each of one RM of 10.00 sqmm main cable and one RM of 10.00 sqmm cable earth wire together including conduit shall be considered as 1 running metre for payment purpose.
Vertical three phase distribution board, TPN, 12 way 440 volts having HSNCODE 8537 protection, double door with provision for fixing of MCCBs as incomer and MCBs as outgoing complete after taking down existing unservicable main switch, busbar, GI box including accessories therein & disposing from site including taking down complete all as specified and directed by Engineer-in-Charge. Make:CAT PART NO:DHDLVSRWGOFO12 HAVELLS of Legrand or equavalent to / SIEMENS/Schneider
MCCB 4P 100 Amps, 415 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and directed by Engineer-in-Charge. Make:CAT PART NO:408683 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCB SPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and directed by Engineer-in-Charge. Make:CAT PART NO:408618 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
MCB SPN 40 Amps, 240 Volts, 240 Volts, having breaking capacity 10 kA 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and directed by Engineer-in-Charge.
MCB single pole, 6-20 Amp, 240 Volts, having breaking capacity 10 kA 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and directed by Engineer-in-Charge.
MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 12 way SPN with 200 Amp rated bus bar 230 volt AC supply including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and directed by Engineer-in-Charge.
Taking down carefully old serviceable/ unserviceable existing conventional light fittings such as T-5/ T-8/ box type /bulk head, 1x40 watt; 1x20 watt, ceiling panel lights etc from existing buildings and disposing off from site complete all as specified and directed by Engineer-in-Charge. Note : Existing serviceable LED luminaries will not be taken down / replaced.
S&F in repairs indoor decorative extruded aluminium anodised housing/CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink/aluminium housing for excellent heat dissipation; 4 feet (approx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 6000K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, 0 UV radiation light fitting long life burning hours 50000 hours with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed by Engineer-in-Charge. MAKE :CAT Part No:D532065 FOR Batten and rod-P08120 of Wipro or equavalent to Havells/Philips/Crompton Note :- The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.
S&F in replacement LED retrofit lamp with maximum wattage 9 watt (lumen output not less than 900 lumens) with B 22 holder base with thermal conductive engineering plastic white colour housing and aluninium heat sink with specially designed fins clear/cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation long life burning hours 50000 hours complete all as specified.(including taking down of existing serviceable /unserviceable lamps and disposing off as directed by Engineer-in-Charge).
Supply and fixing LED Building light of 35 watt, IP66 power coated pressure die cast aluminium compact high power LED buildimg light with heat resistant toughened glass complete with GI pipe bracket light grade 1.2m long of suitable bore fixed on wall with FI clamps, nuts and bolts of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing steel iron exhaust fan of 300mm sweep with louvers, single phase 240 volts, isuitable for throwing proper air of exhast fan, making good disturbed surface complete all as specified and directed by Engineer-in-Charge.
M&L inreplacement of LT panel Out door type cubical floor mounted type made out 3.15 mm thick MS Sheet duly powder coated complete bus bar 400 Amps rating made of Aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 Wire 415 volts 50HZ Power suply system suitable for and including the following:- (a) MCCB 415 Volts 400Amps 4 Pole with Reputing CAP 36KA Microprocessar based for over load short circuit protation : 01 Nos incoming (b) MCCB 415 Volts 150 Amps 4 Pole with Reputing CAP 36KA Microprocessar based for over load short circuit protation : 03 Nos (c) All acessories prewired with suitable size copper conductor cable/strip and suitable foundation as per manufactors remcomendation (d) Indicator set RYB 01 Set 3 pcs Led type
M&L inreplacement of LT panel Out door type cubical floor mounted type made out 3.15mm thick MS Sheet duly powder coated complete bus bar 200 Amps rating made of Aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 Wire 415 volts 50HZ Power suply system suitable for and including the following (a) MCCB 415 Volts 200Amps 4 Pole with Reputing CAP 36KA Microprocessar based for over load short circuit protation : 01 Nos incoming (b) MCCB 415 Volts 150 Amps 4 Pole with Reputing CAP 36KA Microprocessar based for over load short circuit protation : 01 Nos (c) All acessories prewired with suitable size copper conductor cable/strip and suitable foundation as per manufactors remcomendation (d) Indicator set RYB 01 Set 3 pcs Led type
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 70 Sqmm 3.5 core laid on walls/floors or in air with saddles and gutties complete all as specified and directed by Engineer-in-Charge. Note:- (i) The rate for passing of cable through road , wall , culvert , floor, drain etc and disturbed surfaces will be done as per exsisting are deemed to be included in the quoted rate and nothing extra shall be addmissible on thie account . Biddre are requested to quote their rate accordingly.
Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion complete all as specified and directed by Engineer-in-Charge.. Note : Upto 7.5 mtr length of pipe of 15 mm bore GI strip and GI wire including test point shall be deemed to be included in unit rate quoted by tenderer.
Supply and fixing of Earth continuity conductor or main 25x4 mm Galvanised iron streep strip or main earthing lead fixed to wall on battenor recess or chases including plastic type insulatoror buried inground or drawn in conduit/pipe orfixed to poles or any other indicatedsituation for loop earthing etc. all as required and including taking out old unsv up to building height .complete all as specified and directed by Engineer-in-Charge.
Taking down fan, ceiling cable end, dismantling blades and removing fan and blades to store complete all as specified and directed by Engineer-in-Charge.
M&L Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc including Hanging only ceiling fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge.
Rewinding of existing ceiling fan including of ball bearing Cutting of all copper coils & taking out burnt/damaged wire from sweep ceiling fan motor of any make and M&L for rewinding of ceiling fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing, assembling and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers , fastner complete including suitable hole cutting of walls making good plastering and fixing of properly E/fan all as specified and directed.
S&F in replacement LED retrofit lamp with maximum wattage 7 watt (lumen output not less than 500 lumens) with B 22 holder base with thermal conductive engineering plastic white colour housing and aluninium heat sink with specially designed fins clear/cool white, power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 volt to 285 volt AC at 50 Hz, glarefree, 0 UV radiation long life burning hours 50000 hours complete all as specified. (including taking down of existing serviceable/unserviceable lamps and disposing off as directed by Engineer-in-Charge).
Suppy and fixing of GI tube light grade of bore 80 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building height complete including taking down all as specified and directed by complete all as specified and directed by Engineer-in-Charge.
SCH A PART-II (B/R WORKS)
Taking down Chowkats or Frame (without taking off shutter from the frame) exc. 1.50 SQUARE METRE but n exc 4.00 Sqm each complete all as specified and directed by Engineer-in-Charge
Taking down Chowkats or Frame (without taking off shutter from the frame) n exc. 1.50 SQUARE METRE complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description but exc. 1 Sqm and n exc. 2 Sqm each complete all as specified and directed by Engineer-in-Charge
Refixing of shutters in same openning any description exc 1 Sqm but n exc 2 Sqm each complete all as specified and directed by Engineer-in-Charge
M & L for Pressed steel frames of size 125 X 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed by Engineer-in-Charge
All as per item No 5 above but frame size 105 X 60mm complete all as specified and directed by Engineer-in-Charge.
S & F 35 mm thick 2nd class hard wood plain framed shutter any number of parels) with panel of timber flat on both sides (Feather edges) or of veneered particle board medium density wood particle baord with commercial face veneers supply and fixed to chowkat complete all as specified and directed by Engineer-in-Charge
S/F 35 mm thick factory made 2nd class hard wood glazed and skelton door shutter open rebated and prepared to receive glass gauze etc (without shas bar) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of numbers of shutter as specified in SSR Pt I Section 8, clause 8.2 (a) complete all as specified and directed by Engineer-in-Charge.
M & L for Steel window 1.25 mm thick box type (primer coated )ERW hollow section of size 80X35 mm double rebated gauged, glazed skelton shutter ERW sec 50X20mm and 1mm thick with two openable leaf consisting two nos sash bar of T sec 20X3mm completed welded to frame with one vertical mullion of ERW box type T sec of size 30X25mm and 1.25mm thick including following fitting welded to framed shutters : (i) hold fast , 150mm long of 12mmX3 mm made of shape 04 Nos per window (ii)) handle of Z section 20mm to 25mm, 100mm long stope 1 No per leaf (iii) MS tower bolt 150mm long 02 no per leaf (iv) Z section 20mm X to 25mm , 100mm long stope 01 nos per leaf (v) cleat 65 mm long of hollow of size 15X20X63mm welded to hinge 01 nos per leaf (vi) fabrication & fixing. incl guard bars complete all as specified and directed by Engineer-in-Charge.
S/F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm thick coloured PVC sheet reinforced with MS square tube complete all as specified and directed by Engineer-in-Charge.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded coloured PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and coloured PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail: Panelling of coloured PVC sheet to be fitted in the M.S frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site complete all as specified & directed by Engineer-in-Charge
S & F Factory made fully glazed (frosted/ground/obscured)/fully gauged PVC window/ventilator shutter 30mm thick(Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC C Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top and bottom rail on either side and as gap inserted for top and bottom rail(rate incl glass panes/gauges) complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:2:4 type B-1 (20mm graded aggr) as in lintels up to 1.50m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing up to 60cm in height, copings kneelers, apex stones, bed plates, kerbs, water troughs and the like incl weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge.
M/L for treating small aricle such as stops, covers, gully, gratings and hold fast ends & post backs of chowkat etc area n exc 0.10 Sqm each complete all as specified and directed by Engineer-in-Charge.
S/F Galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm fitted with tinned tacles or galvanised wire staples complete all as specified and directed by Engineer-in-Charge.
Ditto all as per item No above but in repair complete all as specified and directed by Engineer-in-Charge.
S & F Sheet Glass, 3.0mm thick glazing with Beads or Oil Putty, not exc. 0.50 SQUARE METRE in Each Pane, complete all as specified and directed by Engineer-in-Charge.
Ditto all as per item above but pinheaded complete all as specified and directed by Engineer-in-Charge.
S/F 200 mm long Aluminium anodised barrel tower Bolt with bright bolt end fitted complete all as specified and directed by Engineer-in-Charge.
S/F 150 mm long Aluminium anodised barrel tower Bolt with bright bolt end fitted complete all as specified and directed by Engineer-in-Charge..
S & F 150 mm long Aluminium handles, cast type, anodised complete all as specified and directed by Engineer-in-Charge.
S/F 100 mm long Butt Hinges Medium Weight, Aluminium and fixed complete all as specified and directed by Engineer-in-Charge.
M & L for helical door spring 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge.
M/L appying two coats of synthetic enamel paint over a coat of pink primer on wooden surface any description over 10 cm in width or girth not otherwise described including preparation complete all as specified and directed by Engineer-in-Charge.
M & L Preparation of new steel and iron surfaces of any description over 10 CM width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of of any descriptions, in Ground floors (Floor Topping, Sub Base etc) not exc 150mm thick, above or below ground level complete all as specified and directed by Engineer-in-Charge.
Dismantling floor,hearth or wall tiling including cement mortar bedding(but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M & L machine cut Kota stone slab flooring 20-25mm thick laid over and incl 15mm thick cement screed base in cement mortar 1:6 ,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polshing complete all as specified and directed by Engineer-in-Charge.
Ditto all as per item No 33 above but on vertical surface as in riser of steps, skirting ,dado and pillar laid over cement screed abd jointed over 10mm thk rendering in CM 1:4. complete all as specified and directed by Engineer-in-Charge.
M & L for Non-Skid Coloured Tiles 300X300X7mm thick in Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Colour Cement to match, complete over 15mm thick screed bedding layer of cement mortar in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M & L glazed coloured ceramic tiles Standard economic class B-III a grade of size 350x250x7mm/450x350x7mm thick thick vertical surfaces such skirting ,dados, rises to stpes etc set and jointed in neat cement slurry and pointed in white or colour cement to match the surface incl 10mm thick rendering in cement mortar in 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for 50mm thk plain cement concrete type C-2 1:3:6 using 40mm graded Agg as in Plinth protection complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on Brick Walls, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, remove dust, debries/rubbish etc complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work, stone/boulder masonry built in CM complete all as specified and directed by Engineer-in-Charge.
M&L brick work with sub class B bricks straight or curved on plan exc 6m redius in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L brick work with sub class B bricks straight or curved on plan to any radious in half brick thick built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M & L for Rendering 15mm thick in cement mortar 1:6 on INTERNAL fair faces of Brick walls or on concrete surfaces, finished even and smooth W/O using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for Rendering 15mm thick in cement mortar 1:4 on EXTERNAL other than fair faces or Brick walls or on concrete surfaces plastered surfaces finished even and smooth without using extra cement with WPC as per manufactare instruction complete all as specified and directed by Engineer-in-Charge.
M\L 5mm thick rendering in cement mortar 1:3 on concrete surfaces, ceiling etc finished surface even and smooth, without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a 2/3mm coat of wall care putty chalk whitening preparatory to distempering including preparation of surface complete, all as specified and as directed by Engr-in-Charge
M&L for applying two coats of Acrylic Exterior Emulsion paint camouflage pattern on newly/old plastered surfaces of walls over a 2/3mm coat of wall care puttyand preparation of walls of any tint or colour complete all as specified and directed by Engr-in-Charge.
M & L Preparing New surfaces of ceiling and applying three coats of white wash, complete all as specified and directed by Engineer-in-Charge.
Supply only Liquid water proofing compound complete all as specified and directed by Engineer-in-Charge..
S & F in repair PVC Flushing Cistern 10 litre capacity low level valve less, symphonic action type white with inlet, ball valve, flaoat and handle including 32mm dia PVC Flush pipe a pair of cast iron brackets duly painted/erecting stand including cutting and pinning in ends, making good disturgbed surfaces in cement mortar 1:3 including taking down unserviceable flushing cistern complete all as specified and directed by Engineer-in-Charge.
S & F in repair PVC Conncetions 15mm size with PTMT Nuts of length 450mm and fixed including taking down unserviceable PVC Connections, complete all as specified and directed by Engineer-in-Charge.
S & F in repair angular value 15mm bore fancy type Chromium Plated, screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwdd and Fly-Nuts screwed for Iron Pipe or Brass Ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S/F in repair concealed stop cock 15mm bore fancy type Chromium Plated regular body with adjustable wall flange complete all as specified and directed by Engineer-in-Charge.
S & F in repair Vitreous china wash hand basin size 550x400mm (flat back or angle back type) including 32mm dia brass chromium plated waste fitting a pair if cast iron bracket duly painted / erecting stand including cutting and pinning in ends making good disturbed surfaces in CM 1:3 including taking down unserviceable wash hand basin and connected items of any description, complete all as specified and directed by Engineer-in-Charge.
S & F in repair pillar cock 15mm bore fancy type chromium plated, screwed down high pressure with or without lettered HOT or COLD with long screwed and fly-nuts screwed for iron pipe or brass ferrule and fixed in repair complete all as specified and directed by Engineer-in-Charge.
M &L HDPE waste pipe of 32mm dia pressure rating 6 Kgs/Sq cm fixed complete to walls floors etc complete all as specified and directed by Engineer-in-Charge..
S & F in repair looking mirror of size 600 x 450 , 6mm thick with bedding and 6mm thick commercial ply board complete all as specified and directed by Engineer-in-Charge. .
S & F in repair CP brass tubular towel rail 600mm long with hooks and 3 nos CP rod at top fixed to walls complete all as specified and directed by Engineer-in-Charge.
S & F in repair Chromium plated soap dish as approved by GE as fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S & F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
S & F in repair Bib taps cast copper alloy 15mm bore, fancy type Chromium Plated , screwed down high pressure with crutch or butterfly handle, screwdd both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in repair brass CP shower rose 125mm size with or without swivel joints, incl fixing to steel pipe or union fixing complete all as specified and directed by Engineer-in-Charge..
S & F in repair brass CP arm 15mm size shower arm , 195mm long with bend of 45 degree with flange fixed in repairs complete all as specified and directed by Engineer-in-Charge.
Taking down or up steel 20mm bore water tubing and connections including cleaning for re fixing or removal to store complete all as specified and directed by Engineer-in-Charge.
-Ditto- All as per item no above but 15mm dia bore complete all as specified and directed by Engineer-in-Charge.
M&L 20mm dia bore steel tubing medium grade galvanised with all fittings and fixed concealed in wall , ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
M&L 15mm dia bore steel tubing medium grade galvanised with all fittings and fixed concealed in wall , ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Harrison rails, mild steel, chromium plated with fixing brackets stops, rollers etc complete all as specified and directed by Engineer-in-Charge.
S & F in repair Vitreous china squatting Pan 'Orrisa" Pattern size 580 x 440 mm white with integral foot rest connecting flushing cistern and flush pipe in repair complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china urinal half stalled type white (excluding flushing ciestern) fixed complete all as specified and directed by Engineer-in-Charge.
Taking down eaves gutters and rain water pipes (any size or pattern),incl all fittings,heads,shoes,bends,swan-necks etc including cleaning or refixing complete all as specified and directed by Engineer-in-Charge.
M & L for PVC (SWR) 110mm bore (dia) soil, waste and ventilating pipe, Singe Socketed, in any length with Rubber Ring Joints fixed to Walls, complete all as specified and directed by Engineer-in-Charge.
M & L for PVC (SWR) 75mm bore (dia) soil, waste and ventilating pipe, Singe Socketed, in any length with Rubber Ring Joints fixed to Walls, complete all as specified and directed by Engineer-in-Charge.
M & L for PVC (SWR) 75mm bore (dia), Bends any type complete all as specified and directed by Engineer-in-Charge.
M & L for PVC (SWR) 110mm bore (dia), Bends any type, complete all as specified and directed by Engineer-in-Charge.
M&L RCC (nominal mix) type B1 (1:2:4) (20mm graded aggregate) in slabs supported on walls, bearms and columns in floors, roofs, landings, balconies, canopies, dech slabs and in shelves etc complete all as specified and directed by Engineer-in-Charge..
Form work to soffits of roof slabs, floor slabs, landings etc & similar work n.exc 200mm thick with rough flat finished surfaces of concrete horizontal or sloping complete all as specified and directed by Engineer-in-Charge.
M & L TMT bars 10mm dia and over, cut to length bent to shape required incl crancking , bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conf to TMt complete all as specified and directed by Engineer-in-Charge.
M&L 20 mm thick granite work (table rubbed and polished) for wall lining (veneering to wall) 15mm thick in CM 1:4 and pointing with white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over 10mm thick rendering complete all as specified and directed by Engineer-in-Charge..
M&L 20 mm thick granite work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in CM 1:3 and pointing with white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over 10mm thick rendering complete all as specified and directed by Engineer-in-Charge..
S & F PVC (SWR) vent cowl 75mm bore complete all as specified and directed by Engineer-in-Charge..
S & F in repair for PVC (SWR) floor/ nahani trap 75mm with gratings including Jointing to waste pipe with solvent cement complete all as specified and directed by Engineer-in-Charge. .
Demolition of cement concrete of any description and in have any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
M & L for mass concrete filling using PCC ( 1:5:10) type E2 in sunken floor complete all as specified and directed by Engineer-in-Charge..
M & L 20mm thick cement plaster in CM 1:4 mixed with water proofing compound @ 3% and applying water proffing treatment on sunken portion with acrylic based polymer modifed cementitious composit compound as specified and approved & cement slurry two layers, 1st layer @ 0.488 Kg/ Sqm mixed with composit compound @ 0.253 Kg/Sqm, & the second layer slurry @0.242 Kg/Sqm mixed 0.126 Kg of compound complete with min 4 hours allowed to air cure between these layers and applying 200 µ polyflim with adhesive complete all as specified and directed by Engineer-in-Charge..
M &L for Preparation of Old decorated Plastered or unplastered surfaces of wall and applying TWO coat of Oil Bound distemperd complete all as specified and directed by Engineer-in-Charge.
M &L for Preparation of Old decorated Plastered or unplastered surfaces of ceiling and applying one coat of white wash, complete all as specified and directed by Engineer-in-Charge.
M &L for Preparation of Old decorated Plastered or unplastered surfaces of wall and applying one coat of white wash on walls complete all as specified and directed by Engineer-in-Charge.
M &L for Preparation of Old decorated Plastered or unplastered surfaces of wall including cleaning brooming down or with steel wire brushing, scrapping down smooke soot, moulds, moss and efflorescent salts cleaning oil and geasy spots, trading oil, greasy spots etc and applying one coat of Acrylic Exterior Emulsion paint camouflange pattern complete all as specified and directed by Engineer-in-Charge.
M/L appying one coat synthetic enamel paint on old wooden surface of any description over 10 cm in width or girth not otherwise described including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for GI wire netting 0.90mm dia and12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and directed by Engineer-in-Charge.
ANIKET TRADERS
PARAS RAM ASGOTRA AND SONS
VISHWA MITTAR PACHYALA
SHIVAE CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .