Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC | L1 | Accepted-AOC Bidder is L1 | |
| 2 | L2₹28.5 L+₹1.1 L (4.12%)Rejected-AOC 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L2 | Rejected-AOC Bidder is L2 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
28 Dec 2023, 6:00 pmClosed
CWE Jalandhar Cantt
HQ CWE Nalwa Road Jalandhar Cantt PIN-144005
Please refer tender documents
2023_MES_628591_1
8323/47/E8
Open Tender
Civil Works - Water Works
Item Rate
334 days
Jalandhar Cantt
Class D Category a(ii) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
AGE (I) Suranussi
₹70,000
Yes
2 Sept 2024
16 Nov 2023
4 Jan 2024
16 Nov 2023
28 Dec 2023
16 Dec 2023
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying CI/GI pipe lines compete all as specified and directed by Engineer-in-Charge.
Returing, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layers compete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Taking up or down CI /GI tubing along with connections and fittings and keeping in safe coustody the serviceable items for reuse and removal of unserviceable items from site of work for following size :-
150mm bore
100 mm bore
80 mm bore
50 mm bore
40 mm bore
20/25 mm bore
Relaying only CI/GI pipes any grade in trenches removed from Sl item No. 4 :-
150mm bore
100 mm bore
80 mm bore
50 mm bore
40 mm bore
25 mm bore
Supply and lay in trenches DI pipe with all fittings complete for following size :- Make : As per appendix 'B'
150mm mm bore
100mm mm bore
80mm mm bore
Supply and lay in trenches medium grade steel water tubing galvanised with all fittings complete :- Make : As per appendix 'B'
50 mm bore
40 mm bore
25 mm bore
20 mm bore
Supply and fixing in cast iron sluice valve PN 1.6 150 mm bore with flanged ends ISI mark with Gun metal spindle CI gate with brass ring and iron wheel handle with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S sluice valve complete all as specified. Make : As per appendix 'B'
All as per item ser No 8 above here in before but 100 mm bore
All as per item ser No 8 above here in before but 80 mm bore
Supplying, fixing, testing and commissioning flanged type 150 mm dia cast Iron swing check type reflux ( Non Return ) valve single door pattern conforming to IS : 5312 ( part – I ) – 1969, duly drilled holes for fixing nuts and bolts including rubber gasket, nuts, bolts and washers and rubber insertion sheet etc including taking out old U/S NRV complete all as specified. Make : As per appendix 'B'
Supplying, fixing, testing and commissioning flanged type 100 mm dia cast Iron swing check type reflux ( Non Return ) valve single door pattern conforming to IS : 5312 ( part – I ) – 1969, duly drilled holes for fixing nuts and bolts including rubber gasket, nuts, bolts and washers and rubber insertion sheet etc including taking out old U/S NRV complete all as specified. Make : As per appendix 'B'
Material and Labour for lead joint suitable for CI pipe 150 mm bore complete all as specified.
All as per item ser No 13 above here in before but 100 mm bore.
All as per item ser No 13 above here in before but 80 mm bore.
Material and Labour required for earth work in trenches / pit and bailing out water to rectifying leaking joint of CI pipe spigot and socket type 150 mm bore as required cocking and levelling the excavated material after rectifying the leakage complete all as specified.
All as per item ser No 16 above here in before but 80/100 mm bore.
Material and Labour cutting of existing CI pipe lines and connecting with new laid CI pipe line 150 mm bore complete including dewatering & excavation all as specified. (Note :- CI fitting and lead joint shall be measured and paid for separtely)
All as per item No 18 here in before but 100 mm bore
M &L for carrying out Repair to existing valve pits of any size & location, taking out loose cover, removing vegetable, small plants inside and outside of chamber, dismantling brick wall as per follows works/items applying two coats of white wash on newly plastered surfaces internally and applying a coat of synthetic enamel paint over a coat of red oxide zinc chrome primer all over to newly chamber cover and frame work complete all as specified and directed (New brick wall, Plaster, PCC in coping, frame work for cover & cover shall be measured and paid separately under respective items of BOQ) :-
M&L for brick work using sub class 'B' in CM 1:4.
M&L for rendering 15mm thick in CM 1:4 finishing even and fair.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) as in coping.
Supply, fabricating and fix valve chamber cover with handle made out of MS plain sheet of thickness 1.6 mm as per IS 2062 complete as specified and directed.
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of chamber cover and similar work conforming to Fe.290.Gde-E-165.
Supply only orthotolidine reagenet for chlorine test in 500 ml bottle of all as specified and as directed. Make :- glaxo / SDS / Ran baxy
Attending complaints by deploying sufficient labour (Plumber (skilled) & helper (unskilled) for repair to leakage/blockage of underground water carrying pipes, size 25 to 150 mm bore of any description such as AC/GI/CI/DI, at any location including necessary excavation & earth work, cutting existing pipe lines, dewatering etc complete all as specified. Note:- (i) Complaint shall be notified to contractor on telephone, therefore it is mandatory for the contractor to mention his ‘Mobile Number’ while quoting the tender. (ii) Complaint shall be notified to contractor at any time between 0600 hrs to 2000 hrs and the same shall be immediately attended and defects rectified within six hrs from notification of complaint to the contractor. (iii) Confirmation of attendance & rectification of complaint shall be given in writing by the contractor and same shall be recorded in the ‘Register’ maintained for the purpose. The ‘Register’ shall be produced to this office along with RAR/Final Bill. (iv) In case the contractor fails to attend complaints within stipulated time (i.e. 6 hrs), a penalty shall be imposed @ Rs 300/- per complaint. (iv) Rates quoted by the contractor shall be deemed included the cost of necessary T& P required. (v) Pipes and cost of jointing shall be measured and paid separately under respective items.
Supply only Pig Lead.
Supply only Lead wool.
Supply only Red or white lead cement.
Supply only Spun Yarn.
Supply and fixing On load change over switch front handle operated 400 Amp open execution Four pole 415 volt Cat No. IHCNFO0400 (Havells) including complete connection as specified and directed. Make : As per appendix 'B'
Material and Labour for replacement on load change over Rotary type 4 pole 415 volt 200 Amp Cat No. IHCNFO0200 including complete connection as specified and directed. Make : As per appendix 'B'
All as per ser item No 33 here in - before but 100 Amp. Make : As per appendix 'B'
Supply & Fixing in replacement MCCB micro processor in built earth fault 400 Amp 4 pole 36 KA 415 Volt complete all as specified and directed. Make : As per appendix 'B'
Supply & Fixing in replacement MCCB micro processor in built earth fault 200 Amp 4 pole 35 KA 415 Volt complete all as specified and directed. Make : As per appendix 'B'
Supply & Fixing in replacement MCCB micro processor in built earth fault 100 Amp 4 pole 36 KA 415 Volt complete all as specified and directed. Make : As per appendix 'B'
Supply & Fixing in repair cast iron fitting such as bend any type radius and angle taper any type straight bends, increasing decreasing tee pieces single branch,Y junction coller ,cap and plug with spigot/socket end flange upto 150 mm bore including taking out old material all as directed.
Material and Labour for disconnecting electric connection and pipe connection and taking out subermisible pump & motor of capacity 25 to 35 HP from bore well and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same gauge and weight to existing including replacement of motor bush, thrust plate coupling complete with key and reassembling the motor with pump and taking back to site, lowering it into bore well making it functional and testing complete all as specified.
All as per ser item No 39 here in-before but 15 to 20 HP complete all as specified and directed.
Repair/replacement of unserviceable part of submersible pump capacity 25 to 30 HP such as gun metal bush impellor assembly shaft locking key and MS nuts & bolts of existing size and reassembling the pump with motor and making it functional all as specified.
All as per ser item No. 41 here n before but 15 to 20 HP.
Disconnecting the electrical connection & taking down the burnt out motor from capacity 5 HP any location and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as per existing gauge including replacement of bearings & correcting minor defects, reassembling, transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified & directed.
Supply and fix contractor ML-2 with 220 Volt coil. AC-03 rating 32 Amp 440 Volt parts No SS90701 complete all as specified and directed. Make :- As per appendix 'B'
All as per item No.44 but with 415 Volt 50 Amp coil. Make :- As per appendix 'B'
Supply only Battery 12 volts 180AH. Make : As per appendix 'B'
Supply and fix in replacment of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 20 mm bore complete all as specified and directed. Make : As per appendix 'B'
All as per item ser No 47 above here in before but 25 mm bore. Make : As per appendix 'B'
All as per item ser No 47 above here in before but 40 mm bore. Make : As per appendix 'B'
All as per item ser No 47 above here in before but 50 mm bore. Make :- As per appendix 'B'
Supply & Fixing Pressure switch Universal type complete all as specified and directed.
Supply & Fixing PVC insulated submersible cable three core flat 1100 Volt AC Supply multistranded stranded copper conductor of size 10 sqmm in replacement of old U/S cable complete all as specified and directed. Make:- As per appendix 'B'
Same as per item No 52 but of size 16 sqmm. Make:- As per appendix 'B'
Same as per item No 52 but of size 25 sqmm. Make : As per appendix 'B'
Supply & Fixing GI coloumn pipe 100mm dia heavy duty 'C' class with flanged ends drill 3 meter including joining to exising main pipe line complete all as specified and directed (the cost of nuts bolts washers packing materials and pressure gauge shall be deemed to include in unit rate quoted by the contractor. Make : Jindal/Tata/ Ravindera.
Supply only Calcium based granular disinfectant for water treatment more stable than chlorine gas and stronger than bleaching powder (calcium Hypochloride) with following specifications Chemical. Name : Calcium Hypochloride Common Name : Stable Bleaching Powder/High strenth Bleaching Powder Apperance : Dry free flowing and free from lumps. Toxic & Undersirabe substance : Should not induce substance beyond acceptance limit as given in IS:10500(2012) in treated and disinfected water. Packing : 20-25 Kg bags/40-45 Kg drums. Packing in drums is preferable to reduce fire hazard in places of high ambient temperature. Available Chlorine : 65 % to 70 % my mass (min). Stability : 1/15 Loss of Choride on basis of available chloride (max). Particle size (Passing through 1.70 mm IS Sieve) : 99.59 % by masss (min). Water insoluble matter : 6%(max). Calcium Hydroxide : 4%(Max). Sodium Chloride : 5 %(Max) Make : SREE Rayalaseema Hi strength Hypo limited / Puricloro / Techno Aqua Tech Pvt. Ltd or Equivalent approved make of E-in-C's Branch
Supply, installation, commissioning & testing Chlorine Pressure Feed, high pressure Single Head Gear Motorised adjustable Dozing Pump with Accessories including Lead Tubing, Conecting Nuts, Injection Check Valves, Clay Weight and Ferrules including taking out/ removal of old unserviceable one, complete all as specified and as directed. Make :- Idex India Pvt Ltd / Prominent Fluid Control /Grundfos India Pvt Ltd / Milton Roy India Pvt Ltd
Supply, installation, commissioning & testing Liquid Chlorine Dozing System consisting of 40 Litre-100 Litre PE/FRP Tank with lid and level guage along with agitator with shaft and blade in SS-316 (FRP/Epoxy coated )/ Plastic mounted on Tank including taking out/ removal of old unserviceable one complete all as specified and as directed. Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro
Supply, installation, commissioning & testing Dosing Mixture Motor, Single Phase, 230 Volts, 50 Hz with Current consumption 0.4 Amps, Power 120 Watts, 4 Pole Induction Non-synchronous 920 RPM (approx) under Load Motor Shaft dia 15mm, length 50mm Motor is Flange mounted 4 Nos. of 7mm dia holes at PCD 150mm including taking out/ removal of old unserviceable one, complete all as specified and as directed. Make :- Grundfos/ M&P/KSB
Supply and fixing Agitator Shaft in the Dosing Tank made out of Poly-propylene Rigid of dia 32mm, length 500mm with Two Bladed Pitched Blade Turbine Impeller with 3 Nos. Blades are welded to the Shaft including taking out/ removal of old unserviceable one, complete all as specified and as directed. Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro
M & L for two coat of super enamelled painting to CI/DI pipe line in vertical/ horizantal of RCC overhead Tank of any size and height/staging including colouring of connected Sluice valve or any valves The contractor to quote the including for arrange lader or stage arrangement for painting to vertical pipe line and making painting down ward and upward direction white paint for inlet and out pipe line all specified and directed by Engr in charge. Note : Painting for RCC overhead tank Inlet pipe line,Delivery line, Overflow line and Washout line will be carried out as per Colour Code(type of Colour) as directed by Engineer-in Charge.
S& F Electric shock treatment chart printed on AO size paper duly plastic laminated and fixed inside a wooden/PVC photo franm of 50 mm width with 3 mm sheet glass and 6 mm plywood backing and suitable hanging arrangement to wall with hooks/steel chain etc.including taking down old unserviceable one complete all as psecified and directed.
S& F First aid chart printed on AO size pepr duly plastic laminated and fixed inside a wooden/PVC photo franm of 50 mm width with 3 mm sheet glass and 6 mm plywood backing and suitable hanging arrangement to wall with hooks/steel chain etc.including taking down old unserviceable one complete all as specified and directed.
Supply ony chequered rubber mats of size 2.0 mm x 1.0 mm x 12.5 mm thick (ISI marked)as replacement of old unserviceable mats complete all as specified and as directed.
Development of existing bore well by flushing out with compresser air at presser 10 Kgs/Sqcm approx for removing of sand and silt for obtaining portable water including disconnectiong all electric and water connection on three phase AC supply and taking out carefully 50/80 mm dia GI pipe with submersible cable from borewell and dismantling of each length carefully to bring out the submersible motor and relowering complete after development of borewell and refixing this same motor and pump set including necessary welding and connections complete all as specified and directed. Note :- (i) Unservicaeble/rusted GI pipe of suitable size given in items as :supply only'of this Schedule. (ii) Flushing of bore should not less than 12 hrs for each bore
S&F chlorine testing KIT with colored sample complete with all testing fitment and OT solution in rexine finish box. Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro
S&F chloroscope (Chlorine & PH test kit) for estimation of residual chlorine in water comprises of Plastic box, two tube,Droper and colour filter for colour estimation. Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro
S&F Water Quality TDS tester with ATC,Digital and Pocket type, Range : TDS 0-999 PPM(Mg/L) Model No :- ATDS0016. Make :- Techno Aqua Tech Pvt. Ltd./ Ion Exchange India/ Thermax/ Wipro
M& L water testing of raw water and treated water taking from pump houses(Biological,Physical and Chemical test)/testing of water for iron, PH value.TDS colour.Total alkainity,Total Hardness,trubidity.chloride chlorine,Fluoride,Nitrate Copper,Total Coliform Faecal Coliform arsinic test,Pesticide residual test and submitting the test report from Delhi Test House or reputed laboratory complete all as specified and directed by Engineer-in-charge. Note :- Testing shall be carried out Every Six month as directed by Engineer-in-charge
Material and labour for maintaining of potable /Fresh water to achieve chlorine level by keeping concentrated efforts as per standard water quality specifications of maintaining PPM,PH,TDS levels by checking time to time with standard testing equiptments/lab test items if any daily before pumping of water to users from OHTs to building OH tanks through raising mains etc by adding chlorination granaulas chlorine gas etc.as required for disinfection of water as per standard at site as under :- (a) PPM at OHT to building OH tank -2 PPM. (b) PH value-6.5 to 8.5,TDS-300 ppm. (c) Ensurig water is to be free from E.coli and thermotoerant coliform bacteria and it shall not be detectable in any 100 ml of sample water. Notes :- The item rate is inclusive of the following :- (a) The contractor or his rep is responsible for maintaining quality of drinking water as specified above and to adopt latest standard of water treatment for providing specified potable water. (b) Contractor or his rep has to attend daily at all pump hoses once in a day to check all the water parameters and sign in the register being maintained with pump house staff. (c) Register should be maintained daily and daily record of the same should be endorsed from users/MES rep at pump house,concerned Engineer-in-charge/JE E&M as well as concerned medical team of respective unit daily. (d) Lab test shall be carried out once in a month from locally available Govt approved lab for:- (i) PPM. (ii) TDS. (iii) PH value and E-Coil or thermotolerent Coliform bacteria.test report be rendered and a record of the same to be submitted to department once in a month or whenever required or directed by the users and department depend upon the situation quality of water.
(e) The rate quoted is deemed to be inclusive of adding required chemicals like soda ash etc.to maintain pH value and TDS as and when required. (f) Required quantity of chlorine gas/chlorine granuals/bleaching powder required to be used at pump houses regularly and superchlorination to be done and the same shall be measured and paid seperately under relevant items of schedule.The amout/quantity of mixing chemicals, gas etc. would be very as per the quality of receiving water from time to time to bring the required ppm once checked before pumping the water from sump to OHT of user building.The necessary mixing up of granular/bleaching powder and for maintaning standard water and for super chlorination the existing staff/manpower at pump houses shall be utilized if necessary. The above specified job shall be carried out at each pump house as under :- (a) ME Line. (b) Married acommodation. (c) Pump House NO 2 ABOD. (d) Main Gate Pump House ABOD. (e) Parameter Pump House. (f) Barrier Gate Pump House.
M& L masonary valve chamber of size 900X900x900 mm (internal dimensions) and including necessary excavation and earth work in any type of soil,100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement morter 1:6 plastering internal and pointing flush externally in cm (1:4) as the work proceeds, 50mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) coping 50x50x6 mm thick MS angle iron 5 mm thick MS plate cover with locking arragement, painting exposed steel surfaces with two coats of synthetic enamel paint over a coat of zinc chrome primer including dismantling unserviceable complete all as specified and directed by Engr-in-Charge.
All as per sl item No 72 above but of size 1200X1200x1200 mm (Internal dimensions).
Material and labour for cleaning of RCC equilisation tank of approx size 5.5m x8.0m x5.5 m of STP by bailing out the accumulated raw water at the bottom and removing to complete slit/sludge dirt from the tank and dispositing away exc.1.5 KM and n.exc 5.0 KM from site as directed scrapping tha tank inner walls and bottom with wire brush and cleaning the tank inner walls and bottom by applying anti-bacterial spray completely including applying one coat of white wash to entire tank externally complete all as directed by Engineer-in-charge. Note :- (a) The rate deemed to be inclusive of T&P and transportation required for disposal of sludge/dirt away from the site. (b) The cleaning of tank shall be performed once in two months as per manufactures recommendations.
All as per Sl item No 74 above but for treated water tank of size 8.0mx6.0mx3.5m
M&L for carrying out chemical analysis BOD,COD,TSS.pH & O&G,NO2, HCL,FC test and all other parameter of treated sewer water of STP from Govt authorised laboratory all as per CPCB Norms complete all as directed by Engineer-in charge. Note :- The rate quoted is deemed to be inclusive of testing and collection of water samples in sealed PVC container at STPs
Removing old filter media complete of size 1/8 to 1/16.1/16 to 1/32 inch sizes complete in layers of sludge drying beds of size 4x2.50x1.4m scrapping the internal surfaces of sludge drying beds with wire brush and cleaning with bleaching powder slurry,cleaning with fresh water including applying one coat of white wash on external surface of sludge drying bed and refiling up with new filter media in layers all as per manufactures/ reommendations/ existing including testing and commissioning etc. complete all as directed.
Supply only aggregate filter media for STP(as per existing ) complete of size 1/8 to 1/16.1/16 to 1/32 inch size complete in layers as per existing complete all as specified and as directed.
Supply & filling in specially developed Virgin PP FMR MBBR filter media in MBBR tank suitable for STP of capacity .25/1 MLD as per specification given below draining out 04 Nos MBBR tank complete and taking out unserviceable MBBR media 02 CUM. Makes : ION Echange/Thermax Ltd/Optimus Enviropro Colour : Black Size : 16x22 mm Effective specific : surface Area of Media :- 400 M2/M3 MOC of Media : UV stablized Structure : Cylindrical with External FINS Type of Media : Fluided BIO Media PSA/TSA Ratio (%) : 75 Specific weight (Kg/M2) Surface Area : 0.37 Specific Gravity : 0.90-0.95 Gms/CM3 Max Continuous Operating Temp : 80 Degree C VOLTAGE : > 98 % DENSITY (GM/CC) : 0.93 Media fill Rate Range % Fill of V : 25-55
S&F for two single core PVC insulated unsheathed cable 2.5 sqmm(Nominal area) with multistranded copper conductor cable, 1100 volts grade drawn into PVC casing capping/conduit single core PVC insulated unsheathed cable 2.5 sqmm (nominal area) with multistranded copper conductor (green) 1100 volts grade for sub main wiring including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and as directed.
S& F in repair of Gun Metal Spindle complete with all jointing items suitable for CI sluice valve 1.6 PN size 150 mm dia all as specified and directed.
Same as per item No 81 but suitable for size 100 dia.
Same as per item No 81 but suitable for size 80 dia.
S&F in repair of iron wheel handle with jonting material suitable for CI sluice valve Type PN 1.6 Size 150 mm dia all as specified and directed.
Same as per item No 84 but suitable for size 100 dia.
Same as per item No 84 but suitable for size 80 dia.
Material and labour for Repair/Maint/Replacement of existing Bore hole caps including suitable size of Material as per sample including all necessary arrangement and items all as specified by Engineer-in-charge.
Supply & fixing in replacement of sludge canvas bag as per sample and existing specification and material all as specified and directed by Engineer-in-charge.
M&L for cleaning of over head tanks of capacity 50000 Gallens at 60 feet height through drain out pipe accumulated water in bottom and removing the complete silt from the tanks and disposing of the same, as directed, cleaning and scrubbing the walls and bottom of the tank with bleaching powder and rectification of functionalty check of the water level indicators complete with minimum disturbance of water supply including white washing inside and one coat of cement based paint on out side surface of tanks and painting the date of cleaning and the capccity on the tank and including arresting of leakages by making lead joints for pipe line up to bottom of the tanks complete all as specified and directed by Engineer-in-Charge.
M&L for removing of soil and debris from static tank of 3.6 mtr dia and 3.6 mtr depth by removing of debris upto a depth of 3.6 mtr feet from top level and removing debries from bottom of the well including dewatering by using deisel pump set cleaning with bleaching powder and wire brush after scrapping the walls and bottom of the sump complete including repair of wall /bottom with PCC/Plastering work , white washing inside and one coat of cement based paint on out side surface of walls of static tank and painting the date of cleaning and the capccity on the tank all as directed by Engineer-in-Charge all as specified and as directed.
J.K & Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .