Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.4 LAccepted-Finance | ₹51.4 L | L1 | Accepted-Finance QUALIFIED FINANCIAL SUMMARY |
| 2 | L2₹53.1 L+₹1.7 L (3.32%)Accepted-Finance | ₹53.1 L+₹1.7 L (3.32%) | L2 | Accepted-Finance QUALIFIED FINANCIAL SUMMARY |
| 3 | L3₹53.5 L+₹2.1 L (4.18%)Accepted-Finance | ₹53.5 L+₹2.1 L (4.18%) | L3 | Accepted-Finance QUALIFIED FINANCIAL SUMMARY |
| Sl No | Description | Qty | Unit | pawan shakti enter prises L1 | SHREE BALAJI MAHARAJ L2 | M/s ANSHIKA ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00STRENGTHENING OF 11 KV LINE WORK | ||||||
| 1.01Safe Carriage of Following line materials for 11 KV Line from Store Center to the actual site of work including measuring, weighing,Safe loading, unloading at both ends and proper stacking at site.(ALL DECENTRALISED MATERIAL (SUCH AS AL. LUGS, GROUTING MATERIAL, FENCING MATERIAL)WILL BE ARRANGED AND PROVIDED BY THE CONTRACTOR. | ||||||
| 1.02 | 11 KV VCB (OUT GOING) 200/100/5A 350 MVA | 11 | Nos. | 5,000 ₹55,000 Lowest | 5,000 ₹55,000 Lowest | 5,000 ₹55,000 Lowest |
| 1.03 | 3X185 MM2 XLPE 11 KV | 255 | meter | 5 ₹1,275 Lowest | 5 ₹1,275 Lowest | 5 ₹1,275 Lowest |
| 1.04 | 3*185 MM2 OUT DOOR EPOXY TYPE | 19 | Nos. | 5 ₹95 Lowest | 5 ₹95 Lowest | 5 ₹95 Lowest |
| 1.05 | 11 KV VCB (IN COMING) 600/300/5A 350 MVA, 24 VOLT (1250AMP) | 4 | Nos. | 5,500 ₹22,000 Lowest | 5,500 ₹22,000 Lowest | 5,500 ₹22,000 Lowest |
| 1.06 | 33 KV CTR PANNEL DOUBLE T/F CONTROL | 3 | Nos. | 5,500 ₹16,500 Lowest | 5,500 ₹16,500 Lowest | 5,500 ₹16,500 Lowest |
| 1.07 | 33 KV PT OUTDOOR | 3 | Nos. | 500 ₹1,500 Lowest | 500 ₹1,500 Lowest | 500 ₹1,500 Lowest |
| 1.08 | 33 KV VCB 1250 AMP | 5 | meter | 5,500 ₹27,500 Lowest | 5,500 ₹27,500 Lowest | 5,500 ₹27,500 Lowest |
| 1.09 | 33 KV CT_400-200/1-1 AMP | 12 | Nos. | 500 ₹6,000 Lowest | 500 ₹6,000 Lowest | 500 ₹6,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹52,700
Closing Date
9 Jun 2026, 10:00 amClosed
SHAHJAHANPUR
krishna nagar jail road shahjahanpur
For the work of electric system strengthening under the head Business Plane-2026-2027 under Distribution Division-Tilhar, District shahjahanpur
2026_MVVNL_1154209_1
08(W)/EDCS/2026-27
Open Tender
Miscellaneous Works
Item Rate
45 days
SHAHJAHANPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
SE EDC
₹52,700
Yes
10 Jun 2026
26 May 2026
9 Jun 2026
26 May 2026
9 Jun 2026
26 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1STRENGTHENING OF 11 KV LINE WORK | |||||
| 1.01 | Safe Carriage of Following line materials for 11 KV Line from Store Center to the actual site of work including measuring, weighing,Safe loading, unloading at both ends and proper stacking at site.(ALL DECENTRALISED MATERIAL (SUCH AS AL. LUGS, GROUTING MATERIAL, FENCING MATERIAL)WILL BE ARRANGED AND PROVIDED BY THE CONTRACTOR. | - | - | - | - |
| 1.02 | 11 KV VCB (OUT GOING) 200/100/5A 350 MVA | 11 | Nos. | - | - |
| 1.03 | 3X185 MM2 XLPE 11 KV | 255 | meter | - | - |
| 1.04 | 3*185 MM2 OUT DOOR EPOXY TYPE | 19 | Nos. | - | - |
| 1.05 | 11 KV VCB (IN COMING) 600/300/5A 350 MVA, 24 VOLT (1250AMP) | 4 | Nos. | - | - |
| 1.06 | 33 KV CTR PANNEL DOUBLE T/F CONTROL | 3 | Nos. | - | - |
| 1.07 | 33 KV PT OUTDOOR | 3 | Nos. | - | - |
| 1.08 | 33 KV VCB 1250 AMP | 5 | meter | - | - |
| 1.09 | 33 KV CT_400-200/1-1 AMP | 12 | Nos. | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.53 MB
TENDERFORM_08_2026-2027.pdf
Tender Documents • 1.38 MB
BOQ_2162121.xls
BOQ • 0.26 MB
extension0606.pdf
PDF • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .