Superintending Engineer PMGSY Konkan Region Thane
1sr floor in PWD Compound, Station road Thane west
ADB-RAI-10 A)SH 93 to Pedali Nawghar Road (LR-35, VR-15) Block -Sudhagad B) Gomashi to Fanaswadi Road (LR-67, VR-54)Block - Sudhagad C) SH 94 to Gomashi Balsai Road (LR-66, VR-28,138)Block - Sudhagad District- Raigad
2020_MMGSY_620937_3
MRRDA/MMGSY/SE/ADB/20-21/10/1
Open Tender
Civil Works
Item Rate
365 days
sudhagad
Please refer Tender documents.
7 documents required · 7 mandatory
₹11,200
₹1.7 L
22 Nov 2021
2 Nov 2020
24 Nov 2020
2 Nov 2020
23 Nov 2020
12 Nov 2020
2 Nov 2020 - 9 Nov 2020
Amount
A) Improvement & Maintanance of SH 93 to Pedali Nawghar Road (LR-35, VR-15), Ch. 0/000 to 2/150 Block - Sudhagad District:- Raigad
Bill No. 1 Site Clearance, Dismantling and Earth Works
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. Non Thorny Jungle
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201. Dia 300 to 600mm
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201. Dia 600 to 900mm
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. dia 600 to 900mm
Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
Excavation for roadway in ordinary rock by deploying a dozer D-50 including cutting and pushing the cut earth to site of embankment upto a distance of 100 m (average lead 50 m), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross-sections with lift upto 1.5 m.
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
Removal of telephone/electric poles with wires including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and upto a lead of 1000 m and stacking the serviceable and unserviceable material separately as per Technical Specification Clause 202.
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of subgrade surface if required etc. complete
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.
Providing and fixing in position TMT FE 500, 25mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete
Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel,edges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501(excluding dowel bars and Polythene sheet)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. By Mechanical means
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506 50mm thick using bitumen S-65 (60/70)
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level by Paver finisher to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. by Mechanical means - Bitumen (S-65) VG-30
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A , Type B (by Paver finisher) and Type C as per Technical Specification Clause 510. By Mechanical means Type A - Bitumen S65 (VG30)
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary Soil - upto 3m depth by mechanical means
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary Rock - upto 3m depth by mechanical means
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard Rock - blasting prohibited
Providing & Placing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. PCC M10 grade
Providing & Placing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. PCC M15 grade
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. PCC M15 grade
Supplying, fitting and placing TMT bar reinforcementf in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106dia 1000
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. dia 600
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 Hindi, English, Roman
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302. Stone/boulder
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 Ordinary KM stone
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703. 200M stone (Precast)
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. Boundary pillar
Project Information board - Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Log as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
MMGSY / PMGSY Citizen's Information board - Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed . Retro Reflective sheeting Class A
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. Retro Reflective sheeting Class A
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2
Direction and place indentification signs up to 0.9 sqm size board. - Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600 equilateral triangle
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600x450mm Rectangular
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 900 equilateral triangle
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600 Circular
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 900 x 600 mm Rectangular
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600x600 mm square
Providing and laying in trenches 80 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 8.57 kg/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
B) Improvement & Maintanance of Gomashi to Fanaswadi Road (LR-67, VR-54), Ch. 0/000 to 1/800 Block - Sudhagad District:- Raigad
Bill No. 1 Site Clearance, Dismantling and Earth Works
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. Non Thorny Jungle
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. Thorny Jungle
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201. Dia 300 to 600mm
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201. Dia 600 to 900mm
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. dia 600 to 900mm
Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
Excavation for roadway in ordinary rock by deploying a dozer D-50 including cutting and pushing the cut earth to site of embankment upto a distance of 100 m (average lead 50 m), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross-sections with lift upto 1.5 m.
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
Removal of telephone/electric poles with wires including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and upto a lead of 1000 m and stacking the serviceable and unserviceable material separately as per Technical Specification Clause 202.
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of subgrade surface if required etc. complete
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.
Providing and fixing in position TMT FE 500, 25mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete
Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel,edges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501(excluding dowel bars and Polythene sheet)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. By Mechanical means
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506 50mm thick using bitumen S-65 (60/70)
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level by Paver finisher to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. by Mechanical means - Bitumen (S-65) VG-30
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A , Type B (by Paver finisher) and Type C as per Technical Specification Clause 510. By Mechanical means Type A - Bitumen S65 (VG30)
Providing and laying in trenches 80 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 8.57 kg/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary Soil - upto 3m depth by mechanical means
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary Rock - upto 3m depth by mechanical means
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard Rock - blasting prohibited
Providing & Placing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. PCC M10 grade
Providing & Placing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. PCC M15 grade
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. PCC M15 grade
Supplying, fitting and placing TMT bar reinforcementf in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106dia 1000
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. dia 600
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. dia 600
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 Hindi, English, Roman
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302. Stone/boulder
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 Ordinary KM stone
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703. 200M stone (Precast)
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. Boundary pillar
Project Information board - Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Log as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
MMGSY / PMGSY Citizen's Information board - Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed . Retro Reflective sheeting Class A
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. Retro Reflective sheeting Class A
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2
Direction and place indentification signs up to 0.9 sqm size board. - Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600 equilateral triangle
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600x450mm Rectangular
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 900 equilateral triangle
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600 Circular
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 900 x 600 mm Rectangular
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600x600 mm square
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)""
C) Improvement & Maintanance of SH 94 to Gomashi Balsai Road (LR-66, VR-28,138), Ch. 0/000 to 1/300 Block - Sudhagad District:- Raigad
Bill No. 1 Site Clearance, Dismantling and Earth Works
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. Non Thorny Jungle
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. Thorny Jungle
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201. Dia 300 to 600mm
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201. Dia 600 to 900mm
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. dia 600 to 900mm
Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
Excavation for roadway in ordinary rock by deploying a dozer D-50 including cutting and pushing the cut earth to site of embankment upto a distance of 100 m (average lead 50 m), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross-sections with lift upto 1.5 m.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and crosssections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5
Excavation for roadway in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and crosssections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
Removal of telephone/electric poles with wires including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and upto a lead of 1000 m and stacking the serviceable and unserviceable material separately as per Technical Specification Clause 202.
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. By Mechanical means
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506 50mm thick using bitumen S-65 (60/70)
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level by Paver finisher to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. by Mechanical means - Bitumen (S-65) VG-30
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A , Type B (by Paver finisher) and Type C as per Technical Specification Clause 510. By Mechanical means Type A - Bitumen S65 (VG30)
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary Soil - upto 3m depth by mechanical means
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary Rock - upto 3m depth by mechanical means
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard Rock - requireing blasting
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Hard Rock - blasting prohibited
Providing & Placing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. PCC M10 grade
Providing & Placing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. PCC M15 grade
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. PCC M15 grade
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204. RCC M20 grade
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. RCC M25 grade
Providing and laying cement concrete wearing course M 30 grade excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing Tar paper bearing of approved quality in proper size etc. complete (Rate as per PWD CSR 2020-21 BR Item no.13.02 Pg no 11
Expansion joint with 25 mm thich bitumenous pad/compressible rubber pad Rate as per PWD CSR for 2018-19) BR 43B Item no.14.33 pg no.123
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106dia 1000
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. dia 600
Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. dia 600
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701 Hindi, English, Roman
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302. Stone/boulder
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 Ordinary KM stone
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703. 200M stone (Precast)
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704. Boundary pillar
Project Information board - Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Log as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
MMGSY / PMGSY Citizen's Information board - Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed . Retro Reflective sheeting Class A
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor. Retro Reflective sheeting Class A
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2
Direction and place indentification signs up to 0.9 sqm size board. - Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600 equilateral triangle
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600x450mm Rectangular
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 900 equilateral triangle
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600 Circular
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 900 x 600 mm Rectangular
Semi Reflective Traffic Signs - Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 600x600 mm square
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to the line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.
Rameshwar Construction
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .