Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹87.9 LAccepted-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹87.9 L | L1 | Accepted-Finance Not being L1 |
| 2 | L2₹90.8 L+₹2.9 L (3.34%)Accepted-Finance 0 SHOP NO 48 BHAGAT SINGH COMPLEX VYAPAR VIHAR ROAD CAR PLANET VYAPAR VIHAR BILASPUR BILASPUR CHHATTISGARH 495001 | BILASPUR | CHHATTISGARH | 495001 | ₹90.8 L+₹2.9 L (3.34%) | L2 | Accepted-Finance Being L1 |
| 3 | L3₹96.9 L+₹9.0 L (10.2%)Accepted-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | ₹96.9 L+₹9.0 L (10.2%) | L3 | Accepted-Finance Not being L1 |
| 4 | Rejected-Technical NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | - | - | Rejected-Technical Due to not enlisted in Cat a(ii)/c(i) |
| Sl No | Description | Qty | Unit | national engineering L1 | SUMEET TRADING CORPORATION L3 | Sona Enterprises L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation ,commissioning and testing of Central heating plant with glycol based Hot water generator of minimum capacity 2.0 lakh K Cal/hr using kerosene/HSD oil complete with combustion chamber and equiped complete with automatic monoblock burner assembly fire tubes, control panel with sequence controller, photo cell for flame failure, HT transfer electrodes, blower assembly, electric panel, mounting frame, pressure gauges at inlet and outlet suitable for operation on 50 Hz, 3 phase 440 volts AC supply complete all as specified and directed
Make: Thermax, Ecoflame, Western, Rapidtherm, Alphatherm
(a)Heater unit:-Heat exchanger ,consisting of closely wound, helical concentric coils, arranged to give adequate no. of passes on flue gas side & made out of ERW tubes confirming to IS 3059 Pt-I suitable for high temperature all as per manufacturer design and of required head and capacity .
(b) Pressure jet burner:-Suitable for light oil firing with stepless modulation mechanism all as per manufacturer design and of required head and capacity. (c) Combustion air fan with drive motor assembly all as per manufacturer design and of required head and capacity. (d) Control Panel : Dust protected pre-wired unit mounted air cooled control panel housing a burner management system , switchgear consisting of contactors, overload relays, fuses and MCB etc.all as per manufacturer design and of required capacity.
Note :- (I) The boiler shall be installed in system of (1W+1S) (II) The tenderer should get the plant installed by any of the original equipment manufacturer with recommended makes of compatible components of items.
(III) The boiler minimum specification should be as under :- (i) The boiler inner shell be made from carbon steel with dished ends (curved type) with thickness as per boiler design of OEM. (ii)Outer shell be made from carbon steel with thickness as per boiler design of OEM. iii) Boiler tube shall be seamless MS tube for quality commensurate with the boiler requirement .
(iv) The front door shall be openable lined with high grade insulation and refactory (v)High efficient, low noise imported monoblock burner (Benton/Rello) (vi)The boiler shall be insulated with 50mm thick resin bonded fibre glass wool and cladded with 22 guage GI sheet (epoxy pointed) or any other thermal insulation as per OEM design.
(vii)Pre wired control panel (made from 18 guage CRC sheet ) Main incomer, MCB in/out temperature controller (digital)fault indicating light for water high temp, burner trip,flue temp, with alarm, hour meter for maint schedule etc.
(viii) 1 set of oil piping from unit to burner . (ix) It includes suitable concrete foundation for Boiler . | 2 | Each Job | 21,50,000 ₹43,00,000 | 22,30,000 ₹44,60,000 | 19,90,000 ₹39,80,000 Lowest |
| 1.01(B) FLUE GAS CHIMNEY : Supply and installation of mild steel flue gas chimney made out of 3 mm thick mild steel sheet, minimum 1.20 m above the highest point of the plant room including connection to independent boiler -02 Nos. (separate for each Boiler) (C) Day Oil Storage Tank Supply, installation, testing and commissioning of Kerosene/HSD oil day storage tank rectangular insulated mild steel (IS 2062) construction with capacity of 990 litres complete with inlet, outlet, over flow drain and vent with flame arrestor. Tank shall be made out of 4mm thick mild steel sheet and will be provided with supports made out of minimum 50 mm dia medium grade pipe to keep tank base at minimum 1000 mm above finished floor level, service the tank shall be provided with level switches for ON-OFF operation of transfer pump. The tank shall be provided with level switches for on-off operation of transfer pump. Extra high level and extra low level alarm shall be provided. Tank and structure shall be painted with synthetic enamelled paint of approved colour as decided by the GE over two coats of red oxide paint, complete all as specified-02 nos and directed. (D) Glycol Expansion Tank Supply and installation of overhead Glycol expansion tank of size 990 Ltr made out of 5 mm thick mild steel cylindrical tank complete covered with 13mm closed cell elastometric insulation complete with removable lid, in/out/drain/overflows system mounting arrangement making connections etc complete all as specified and directed. ( E) Thermic Fluid ( Glycol) Makeup tank Supply and installation of 2000 ltr capacity MS tank madeout of 5 mm thick mild steel cylindrical/ rectangular with removable lid, in/out/drain/overflows system mounting arrangement making connections etc complete all as specified and directed ISI marked. NOTE :-( i) Anything missed out above, but required for smooth opertation of central heating system is deemed to be inclded in the quoted rate. (ii) The capacity of boiler given are minimum estimated, however on detailed calculation if the capacity needs to be enhanced for achieving the desired climating condition mentioned in the contract, is deemed to be included in the quoted rate and accordingly contrator is advised to quote their rate. NO DO in this regard in future shall be admissible. | ||||||
| 2.00 | Transfer gear oil pump fuel (Self priming): Supply installation testing and commissiong of self priming rotary gear transfer pumps of capacity minimum 15 LPM at minimum 10 mtr Head for Kerosene or HSD oil complete with base mounting frame. PCC foundation including holding down bolts, coupling guard and TEFC flame proof motor 2 HP and other accessories required for commissioning etc complete all as specified and directed. | 2 | Each | 40,000 ₹80,000 | 11,500 ₹23,000 Lowest | 18,000 ₹36,000 |
| 3.00 | THERMIC FLUID/ EHYLE GLYCOL CHARGE
Supplying and filling of mono ethylene glycol/ Thermic Fluid concentrate alongwith the necessary additives and inhibitor as per IS- 5759- 2006 in cognition and sealed in barrels. The freezing temperature shall be below (-) 25OC, all specified. However the mode of payment and operations involved for this item shall be as under:-
Notes:
(a) Mono ethylene Glycol in concentrated form shall only be measured and paid under this item.
(b) Material and labour for filling including first filling required for operation of CHS plant
(c) Any other additives and inhibitors as per the requirement laid down in relevant IS shall be also deemed to included in quoted rates.
(d) Empty barrels shall be property of MES. | 5,000 | Ltrs | 150 ₹7,50,000 Lowest | 170 ₹8,50,000 | 150 ₹7,50,000 Lowest |
| 4.00 | Hot liquid Pumping System
Supply, Installing, testing and commissioning of pumping system consisting of horizontal suction and delivery Hot/Chilled liquid pump sets capable of delivering minimum 10 LPS of water against minimum 25 meter head at outlet 1500 RPM including primemover squirrel cage induction motor with TEFC enclosure of 5.0 horse power to drive the pump efficently with class 'F' insulation, 1500 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply.( 01 working + 01 standby)-02 Nos and complete as per specification. The system shall comprise of the following:
(ii) XLPE insulation of suitable thickness duly cladded by aluminum sheets of 0.5mm thickness and properly clamped to pumpsets as per specifications and required -01 Lot.
(iii) Mounting frame with Antivibration pads for 2 Nos of Pumpsets -01 Lot
(iv) Interconnecting piping with valves duly insulated for 2 Nos of Pumpsets -01 Lot
(v) RCC cement concrete foundation for the pumping unit as per OEM for 2 Nos of Pumpsets -01 Lot. | 3 | Each Job | 1,00,000 ₹3,00,000 | 75,000 ₹2,25,000 | 72,000 ₹2,16,000 Lowest |
| 5.00 | Hot glycol/ Thermic fluid based Circuit Piping
Supply, Installation, testing and commissioning of "C"class mild steel hot water piping conforming to IS: 1239 (Part-I) 2004 with all necessary fittings like bends, tees, reducers, flanges, supports and duly insulated with Closed Cell FR-XLPE thickness.including jointing material such as solvent, adhesive , tape insulation, polyglass tape and epoxy resin+ hardener two coats as per manufacturer complete all as specified and directed. The joints shall be sealed with 50 mm X 1 mm thick self adhesive tape complete as per specifications.
Note: (a) Pipe outside the building shall have cladding of 0.5 mm thick aluminium sheets over 50 mm fiber glass insulation and as per specification. (5.1) 50 mm NB with 50 mm thick fiber glass insulation | 350 | Running Metre | 1,500 ₹5,25,000 | 850 ₹2,97,500 | 450 ₹1,57,500 Lowest |
| 6.00 | (5.2) 20 mm NB with 50 mm thick fiber glass insulation. | 90 | Running Metre | 850 ₹76,500 | 700 ₹63,000 | 225 ₹20,250 Lowest |
| 7.00 | Valves
Supply, installation, testing and commissioning of following PN-1.6 valves, strainers gauges in the water piping duly insulated to the same specifications as the connecting piping and adequately supported as per specification and drawings . The water circuit with all fittings and insulation with cladding as per the drawings and specifications. (7.1) Butterfly valve of size 50 mm dia. | 6 | Each | 8,000 ₹48,000 | 8,500 ₹51,000 | 6,600 ₹39,600 Lowest |
| 8.00 | (7.2) Ditto all as per above description 7.00, Check Valve of size 50 mm dia. | 10 | Each | 7,500 ₹75,000 | 8,000 ₹80,000 | 6,600 ₹66,000 Lowest |
| 9.00 | (7.3) Ditto all as per above description 7.00, Y-Strainer of size 50 mm dia. | 3 | Each | 9,000 ₹27,000 Lowest | 9,900 ₹29,700 | 9,900 ₹29,700 |
Tender Value
₹97 L
EMD Value
₹1.7 L
Closing Date
9 Jul 2026, 6:00 pmClosed
HQ CWE AF Leh
HQ CWE AF Leh
SPECIAL REAPIR FOR REPACEMENT OF BER CHS, SPACE HEATER ALONGWITH CONNECTED WORK AT AF STN LEH
2026_MES_768695_1
81248/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF)Leh
As per NIT
9 documents required · 9 mandatory
₹1,000
GE(AF) Leh
₹1.7 L
Yes
10 Aug 2026
30 May 2026
11 Jul 2026
30 May 2026
9 Jul 2026
22 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation ,commissioning and testing of Central heating plant with glycol based Hot water generator of minimum capacity 2.0 lakh K Cal/hr using kerosene/HSD oil complete with combustion chamber and equiped complete with automatic monoblock burner assembly fire tubes, control panel with sequence controller, photo cell for flame failure, HT transfer electrodes, blower assembly, electric panel, mounting frame, pressure gauges at inlet and outlet suitable for operation on 50 Hz, 3 phase 440 volts AC supply complete all as specified and directed
Make: Thermax, Ecoflame, Western, Rapidtherm, Alphatherm
(a)Heater unit:-Heat exchanger ,consisting of closely wound, helical concentric coils, arranged to give adequate no. of passes on flue gas side & made out of ERW tubes confirming to IS 3059 Pt-I suitable for high temperature all as per manufacturer design and of required head and capacity .
(b) Pressure jet burner:-Suitable for light oil firing with stepless modulation mechanism all as per manufacturer design and of required head and capacity. (c) Combustion air fan with drive motor assembly all as per manufacturer design and of required head and capacity. (d) Control Panel : Dust protected pre-wired unit mounted air cooled control panel housing a burner management system , switchgear consisting of contactors, overload relays, fuses and MCB etc.all as per manufacturer design and of required capacity.
Note :- (I) The boiler shall be installed in system of (1W+1S) (II) The tenderer should get the plant installed by any of the original equipment manufacturer with recommended makes of compatible components of items.
(III) The boiler minimum specification should be as under :- (i) The boiler inner shell be made from carbon steel with dished ends (curved type) with thickness as per boiler design of OEM. (ii)Outer shell be made from carbon steel with thickness as per boiler design of OEM. iii) Boiler tube shall be seamless MS tube for quality commensurate with the boiler requirement .
(iv) The front door shall be openable lined with high grade insulation and refactory (v)High efficient, low noise imported monoblock burner (Benton/Rello) (vi)The boiler shall be insulated with 50mm thick resin bonded fibre glass wool and cladded with 22 guage GI sheet (epoxy pointed) or any other thermal insulation as per OEM design.
(vii)Pre wired control panel (made from 18 guage CRC sheet ) Main incomer, MCB in/out temperature controller (digital)fault indicating light for water high temp, burner trip,flue temp, with alarm, hour meter for maint schedule etc.
(viii) 1 set of oil piping from unit to burner . (ix) It includes suitable concrete foundation for Boiler . | 2 | Each Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_860838.xls
BOQ • 0.51 MB
tenderdocuments3.pdf
Tender Documents • 1.27 MB
changenameofworkinBOQ.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .