Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC 2 FLAT NO 2 B GEETHANJALI CLASSIK APARTMENT 9TH CROSS KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹45.7 L+₹1.8 L (4.13%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
24 Jul 2021, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS TO KITCHEN TOILETS PLASTERING AND INTERNAL WIRING ELECTRICAL FITTINGS FIXTURES IN MARRIED ACCOMMODATION BUILDINGS OF MEG AREA UNDER GE NORTH BANGALORE
2021_MES_455382_1
8239
Open Tender
Civil Works
Item Rate
150 days
MEG AND CENTRE
Class D Category a(i)
5 documents required · 5 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹80,000
Yes
23 Aug 2021
28 Jun 2021
26 Jul 2021
28 Jun 2021
24 Jul 2021
12 Jul 2021
28 Jun 2021 - 10 Jul 2021
Amount
PART I (B/R WORKS)
Taking down chowkat (without taking off shutter from the frame) area not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 type B0 or CM 1:3 all as specified and as directed.
All as per Sl Item No 1.001 above, but area exc. 1.50 sqm and not exc. 4.00 sqm each.
Taking down shutters of any description area exc. 1 Sqm but not exc. 2 Sqm each all as specified and as directed.
Box type Steel windows/ventilators double side shutters (windows side hung type, ventilators top hung type) pressed steel frames made out CRC Sheet of 80x60x1.25mm double rebated, shutters box type made out of CRC Sheet of 40x20x1.0mm, windows & ventilator shutters shall be of glass and gauge type, fixed with box type hinges, aluminium die cast handles for glass shutters, Iron flat type handles for mesh shutters, telescopic stays, etc complete all as specified including 12mm square guard bars/grill welded with steel frame (100c/c horizontically) all as specified and directed by Engineer-in-Charge. NOTE: (i) Payment under this item will be make combined for steel frames, steel shutters and Guard bard/Grill, However unit rate quoted shall deemed to include cost of beading, fittings such as handles, hinges,Telescopic stays, locking arrangements. (ii) 4 mm thick sheet glass and wire mesh be measured and paid separately. (iii) Weight of Grill/Guard Bars, handle,hinges and locking arrangements shall not be accounted for payment purpose . (iv) All Windows/Vent design as per CECZ TD drg No 539.
Hacking out old broken glass (any thickness, size, quality or description) from wooden surface, concrete or brick surrounds, glazed with putty or fixed with beads all as specified and as directed.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainles steel wire stapel etc complete all as secified and as directed
All as per Sl Item No.1.006 above but fixed in repairs.
4.00 mm thick sheet glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in wooden frames in squares not exceeding 0.5 sqm in each pane all as directed.
4.00 mm thick figured glass, pin headed type and glazing with oil putty in square not exc 0.50 sqm each panes complete all as specified and as directed.
Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid rounded or chambered, put together with glue pinned at joints complete all as specified and directed.
Factory made flush door shutters 35mm thick, as per IS:2202 (Part-I 1999) solid core construction, with block board core with decorative face veneer both faces with lipping/frame to match as per drawing fixed to chowkats all as speified and directed.
Factory made second class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as specified in SSR Part-1, Section 8, clause 8.24 (a), kiln seasoned and chemically pressure treated complete all as specified and as directed.
Rolled Mild steel framed work as in doors or gates of angle or other sections with gusset plates, rails braces, etc complete drilled for fixing of steel sheeting or other covering, doors etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering, running rails and guides) and hanging ; also fastening and fixing complete including painted with one shop coat of zinc chromate primer paint (including preparation of surface) at contractors workshop/factory before fabrication complete all as specied and directed.
Preparation of new or previously untreated wooden surfaces of any description not other wise described over 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
PVC solid door frame, single rebated of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete as sepecified and directed. NOTE:- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.
Factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm plain colour PVC sheet on back face etc. complete all as specified and as directed.
Mild steel butt hinges, medium weight, cold rolled, 100mm long and fixed to door frame and shutters duly welded/screwed complete all as specified and as directed.
Stainless steel butt hinges, medium weight, cold rolled, 100mm long and fixed to door frame and shutters duly welded/screwed complete all as specified and as directed.
Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed.
Aluminium anodised tower bolt 150 mm long of extruded section etc complete all as specified and as directed.
Aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed.
150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed.
150 mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floors etc., complete all as specified and as directed.
300mm long, mild steel ordinary rat tail rod pattern springs including roller and roller plate etc., complete all as specified and as directed.
Mild steel chromium plated curtain rod 20mm dia with fixing brackets fixed in repairs complete all as specified and as directed.
Taking up or down 15 mm existing steel tubing and connections all as specified and as directed.
Taking up or down 20 mm existing steel tubing and connections all as specified and as directed.
Taking up or down 25 mm existing steel tubing and connections all as specified and as directed.
20mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
25mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
Galvanised iron pipe of 20mm dia, medium grade, laid in floors / fixed to wall with all fittings such as socket, bends, elbow, union etc., complete all as specified and as directed.
Galvanised iron pipe of 25mm dia, medium grade, laid in floors / fixed to wall with all fittings such as socket, bends, elbow, union etc., complete all as specified and as directed.
Dismantling water tanks of any type and removing to store, capacity exc. 250 litres and not exc. 500 litres all as directed.
Dismantling water tanks of any type and removing to store, capacity exc. 500 litres and not exc. 1000 litres all as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs complete all as specified and as directed.
All as per Sl Item No 1.035 above but except tanks. NOTE:- Serviceable tanks as obtained from Sl Item No. 1.033 above shall be reused.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 1000 ltrs complete all as specified and as directed.
All as per Sl Item No 1.037 above but except tanks. NOTE:- Serviceable tanks as obtained from Sl Item No. 1.034 above shall be reused.
20mm dia Ball float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed inrepairs (min weight 20mm-210 gms) all as specified and as directed.
Gun metal gate or globe valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Gun metal gate or globe valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and directed
Providing and laying water proofing treatment to sunken portion of WCs, bathroom and kitchen etc by applying cement slurry mixed with two component elastomeric acrylic based polymer modified cementitious composite compound coating of make as approved in TI 5/2003 including demolition and removal of existing treatment of any type with the following procedure in sequence all as specified and as directed:- (i) Demolition of existing treatment of any type including cleaning and removal of debris from site. (ii) First layer of cement slurry @ 0.488 kg/sqm of cement mixed with acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm, the layer will be allowed to air cure for 4 hours. (iii) Second layer of cement slurry @ 0.242 kg/sqm of cement mixed with with acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm, the layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (iv) 20mm thick screed in cement mortar (1:3) mixed with including supply of liquid water proofing compound as per manufacturers instructions. Contd.. 1.043
Contd.. from 1.042 (v) Ponding the treated portion atleast 48 hours, if any leakage / seepage observed the entire procedures will be repeated without any extra cost. (vi) Provide 40mm dia light grade GI spout at the lowest point with 30cm projection beyond the out face of the wall. (vii) Sunken portion shall be filled with lean cement concrete(1:5:10), type E-2 using 40mm graded stone aggregate. NOTE :- (i) The sunken slab sloped towards outer face to drain the water in to GI spout pipe. (ii) Coving shall be provided at the junction of slab with the wall. (iii) Nahni trap shall be 10mm below finished floor level and drain pipe dia is larger than the nahni trap size. (iv) The outer end of the spout should be chamfered.
Vitreous china wash basin white, flat back, size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopper but including brackets, 32 mm bore waste stainless steel coupling and LDPE pipe of 600 mm long complete all as specified and directed.
Vitreous china wash down water closet pan (Pedestal Pan), coloured, including fixing bolts, flush pipe anti syphonage pipe, plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device etc complete of cera model cat pt no. 2008 complete all as specified and as directed.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including PVC SWR P trap connecting to flush pipe and to anti syphonage pipe, etc. complete including making good to floor, fixed in repairs complete all as specified and directed.
Kitchen sink with drain board overall size 915x460mm, bowl size 410x330x160mm made out of stainless steel 1mm thick kitchen or laboratary sink with plugs, washers and waste including bedding in mortar on to dwarf wall, fixing cantilever brackets and connecting union pipes complete in repairs including taking down the existing sink complete all as specified and as directed.
Stainless steel plate rack made out of of 0.63mm thick stainless steel sheet, over all size 800mm x 600mm with shape, capacity of utensiles and pattern fixed in repairs complete all as specified and as directed.
PVC valveless, syphonic action type, flushing cistern, duo flush,10ltr capacity, low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, fixed in repairs complete all as specified and directed. (MAKE:- Cat No-502 of Prayag or equivalent in any approved make as specified in PS)
15mm bore pillar taps, fancy type, cast copper alloy, with long swan neck, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe all as per Prayag Cat No PIS-14H Neptune series or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Brass chromium plated overhead shower rose 100 mm size with or without swivel joints, any size, including fixing to steel pipe or union all as per Prayag Cat No BS-67 Marcus series or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
15mm dia angle cock CP cast copper alloy screwed down high pressure with capstan head handle screwed both ends or for unions etc., all as per Prayag Cat No PIS-10H Neptune series or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Bib cock 2 way, double handle with chromium plated cast copper alloy, with CP flange all as per Prayag Cat No PIS-12H Neptune series or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Bib taps 15mm dia, cast copper alloy chromium plated, long body, with CP flange all as per Prayag Cat No PIS-08H Neptune series or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Health faucet, brass body, chromium plated with 1mtr long SS braided tube & wall hook all as per Prayag Cat No-BEA-41/BEA-85 or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Towel rail, stainless steel glossy finish all as per Prayag Cat No-BA10S or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Soap dish chromium plated brass all as per Prayag Cat No-BA-45 or techno commercially equivalent makes specified in PS fixed in repairs complete all as specified and as directed.
Peg set of six all as per Cat No BEA 30 of Prayag or equivalent fixed in repairs as on walls all as per manufacturers instructions complete all as specified and as directed.
PVC connections 15mm dia with PTMT nuts of length of 450 mm long fixed in repairs complete all as specfied and as directed.
32 mm dia waste fittings, brass, chromium plated for sinks, basins, etc with long screwed shanks and flynuts,flange end fixed in repairs complete all as specified and as directed.
32mm dia, 800mm long corrugated waste pipe fixed in repairs complete all as specified and as directed.
75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement fixed in repairs complete all as specified and as directed.
Grating doom 100mm dia of PTMT (Minimum weight 25gms) fixed in repairs complete all as specified and as directed.
Bib taps standard of PTMT, any colour screwed for iron pipe suitable for 15mm dia fixed in repairs all as directed.
15mm dia Pillar tap PTMT fancy type any colour screwed, for iron pipe and fixed in repairs complete all as specified and as directed.
15mm dia angle stop valve of PTMT any colour pressed screwed, for iron pipe and fixed in repairs complete all as specified and as directed.
PTMT body health faucet with 1.50 mtr long braided rubber hose pipe and wall hook, fixed in repairs all as per Cat No. 188 of Prayag or techno commerical equivalent models in Essco / Parryware / Hindware complete all as specified and as directed.
75 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings fixed in repairs complete all as specified and as directed.
110 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings fixed in repairs complete all as specified and as directed.
75mm bore PVC (SWR) bends, any radius, type 'B' with access door complete all as specified and as directed.
110mm bore PVC (SWR) bends, any radius, type 'B' with access door complete all as specified and as directed.
75 mm bore PVC (SWR) junction single (single T), type 'B' equal or unequal complete all as specified and as directed.
110mm bore PVC (SWR) junction single (single T), type 'B' equal or unequal complete all as specified and as directed.
110mm bore PVC (SWR) junction single (single Y), type 'B' equal or unequal complete all as specified and as directed.
75mm bore PVC (SWR) junction single (single Y), type 'B' equal or unequal complete all as specified and as directed.
PVC (SWR) branch piece, type 'B' double (double Y) equal or unequal 110mm dia, type 'B' with access door fixed in repairs complete all as specified and as directed.
PVC (SWR) branch piece, type 'B' double (double Y) equal or unequal 75mm dia, type 'B' with access door fixed in repairs complete all as specified and as directed.
PVC (SWR) vent cowl 75 mm dia, type 'B' all as specified and as directed.
PVC (SWR) vent cowl 110 mm dia, type 'B' all as specified and as directed.
Demolition of cement concrete and pavings not exc. 15 cm thick (below or above ground level) complete all as specified and as directed.
Demolition of Reinforced cement concrete (reinforcement cut as required to facilitate demolition) in roof, floors (other than ground floors), beams, staircase, landing, chajjas and similar suspended work complete all as specified and as directed.
Demolition of brick work /stone masonry/PCC block masonry built in cement mortar of any description all as specified and as directed.
Taking down cement plaster of any description including raking out joints, hacking for key and disposing of debris complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off from premises complete all as specifeid and as directed.
Plain Cement Concrete (1:2:4), type B-0 using 12.5mm graded stone aggregate as in floors, 25mm thick finished even and smooth with out using extra cement complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Glazed coloured ceramic tiles as in vertical surfaces / dado 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including backing coat 10mm thick in CM (1:3) on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Vitrified coloured ceramic tiles 8 to 10mm thick (square/rectangular) polished, area of each tile not exc. 0.36sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6) for layaing floor finishes complete all as specified and as directed.
Vitrified ceramic light coloured tiles 8-10mm thick (square/rectangular) polished, area of each tiles not exc 0.36sqm as in vertical surfaces such as skirting / dados, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including backing coat 10mm thick in CM (1:3) on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Pre-polished Machine cut Granite stone slab 18-20mm thick with edge rounded one side laid over 15mm thick cement mortar 1:4 screed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Dismantling single layer Mangalore pattern or similar tiles in roofing complete all as specified and directed.
Allll as per Sl Item No. 1.092 above but portions bedded in cement mortar.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
Dismantling of AC Sheets of any description as in roof covering including ridge, wind tie etc., complete all as specified and directed.
Dismantling timber scantlings 40 sq.cm and over in section, in any position in unframed work all as specified and as directed.
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spaced exc. 15 cm complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
Rolled mild steel work as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connected plates conforming to Fe-410W (Gde E-250) complete all as specified and directed.
Rolled Mild steel work as in hand rails, half round or other stock section or core for wooden hand rail straight portion, drilled and counter shunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-410W (Gde E-250) complete all as specified and directed
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specifed and as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tenisile strenth of 550 Mpa as in roof covering cladding to wall, pre fixed with self taping screwes as specified and as directed.
False ceiling with grid suspended system of size 600 x 600mm with standard sections consisting of main runner 29 x 24.7 x 0.8mm, cross tee 29 x 24.7 x 0.8mm and wall angle 22.2 x 22.2 x0.65mm, ceiling suspended with 3mm dia GI wire hanger fixed with steel dash fastner, butter fly clips, hold down clips etc (main runner, cross tee & wall angle of MS galvanised with PPPCGS) including 4mm thick HPSC self textured design pre primered non asbestos fibre cement building boards fixed to false ceiling including one coat of distemper complete including taking down old existing ceiling of any description complete.
Precast cement concrete block masonry with solid blocks exc. 10 cm in width and setting in cement mortar (1:6) type C1 1:3:6 ( using 20 mm graded aggregate) complete all as specified and as directed.
Precast cement concrete block masonry with solid blocks not exc. 10 cm in width and setting in cement mortar (1:4) type C1 1:3:6 ( using 20 mm graded aggregate) complete all as specified and as directed.
Reinforced cement concrete Type A1 (1:11/2:3) using 20mm graded stone aggregate (nominal mix) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc rough finished the concrete surface in flat complete all as specified and directed
TMT steel bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
TMT steel bars 8mm dia, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips for stirrups, spacers and binders etc complete all as specified and directed.
Plain Cement Concrete type B0, (1:2:4), using 12.5mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges in chajjas etc complete all as specified and directed.
15mm thick rendering on brick or concrete surface in cement mortar (1:6) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in CM(1:4) mixed with water proofing compound as per manufacturers instructions finishing the surfaces even and smooth without using extra cement including necessary scaffolding complete all as specified and directed. NOTE:- WPC will be measured and paid separately under reelvent items.
Supply only integral liquide water proofing compound all as specified and as directed.
Rendering 5 mm thick on ceiling /RCC surfaces in cement mortar (1:3), finished plastered surface even and smooth without using extra cement
Plain Cement Concrete(1:4:8), type D2, using 40mm graded stone aggregate 100mm thick as in sub bases complete all as specified and directed.
Plain cement concrete type (1:3:6) type C-1, using 20 mm graded crushed stone aggregate, 75mm thick as in plinth protection, laid in alternate bays, area not exceeding 2 sqm each, finished the concrete surface even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight all as specified and as directed.
Chequerred cement concrete tiles 300x300x25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigments to match the colour of tiles over 20mm thick screed bed in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M-sand as approved as in cushioning material laid and spread in floors complete all as specified and directed.
Machine pressed (rubber moulded) precast concrete interlocking paver blocks of any shape and size conforming to IS 15658-2006 of 60mm thickness, of M-35 grade with grey cement and pigment complete all as specified and as directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
Preparation of new plaster surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of oil bound emulsion distemper of approved tint over a coat of alkali reistant primer on wall complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer all as specified and as directed.
Prepartation of new or previously un treated ceiling surfaces of any description and applying three coats white wash complete all as specified and as directed.
Demolition of existing roof treatment of any type including cement plaster 10 mm thick and PCC 25mm thick and providing screed bed/rendering 10mm thick in CM (1:4) mixed with and including supply of approved water proofing compound as per manufacturers instructions over and including 25mm thick (average) PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) by removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and providing 50mm x 50mm coving at the corners with PMC mortar as above, and applying APP modified water prrofing membrane as per IS 1654-2017/IS 16352-2017 mineral finish, 3mm thick and weighing not less than 3.60kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litr/Sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sqm complete all as specified and directed.
PART II (E/M WORKS)
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan,call bell socket or power circuits) including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., complete and making good the disturbed surface of walls, ceiling etc., including painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete concealed with 1.5 sq.mm single core PVC insulated unsheathed 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked including accessories concealed in walls including MS terminal boxes fabricated with 1.6 mm thick MS sheet, concealed on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for one light point controlled by one switch.
All as per Sl Item No. 2.002 here in before but for one fan point controlled by one switch/regulator.
All as per Sl Item No. 2.002 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.002 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.002 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.002 here in before but for one 3 pin socket out let 5 Amps on same board.
Point wiring complete surface type with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including PVC Casing & Caping ISI marked with accessories surface type wiring including 1.6 mm thick MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed one light point controlled by one switch.
All as per Sl Item No. 2.008 here in before but for one fan point controlled by one switch/regulator.
All as per Sl Item No. 2.008 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.008 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.008 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.008 here in before but for one 3 pin socket out let 5 A on same board.
Point wiring concealed complete with 2.5 sq.mm single core PVC insulated unsheathed 1100 volts grade multi stranded FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium density ISI marked with accessories concealed type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet, concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete surface type with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and incl non-metalicPVC casing caping ISI marked with accessories concealed wiring incl GI/ MS branded sunken boxes of suitable moodule concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. NOTE FOR Sl ITEM NO. 2.002 to 2.015 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) The cost of cutting the existing wall of any type for laying of PVC conduit and its accessories, fixing of MS/GI sunken boxes and making good the disturbed surface of walls, ceiling etc shall be deemed to be included in the quoted rate.
LED batten suitable for indoor applications 18/20 Watts,4 feet with polycarbonate housing and integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No.830192 18W CDL/ Havells Cat No: LHEXAPP7IN1W020 / C&S Cat no: LTTB4F20W LED EW BATTEN complete all as specified and as directed.
LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No.830206 10W CDL/ Havells Cat No: LHEXACP5IN1W010 of Havells / C&S Cat No:LTTB2F 10WLEDW BATEN all as specified and as directed.
Bulk head fittings of 10 watt, IP -65 type luminaries complete with all accessories including taking out old fittings all as per Bajaj Cat No: BIPWP 10 W LED of BAJAJ or or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Slim surface mounted round LED down lighter of 12 watt aluminium die cast body with premium diffuser to ensure glare free and even distribution of light all as per Bajaj Cat No: BGSLO SLEEK SURFACE 12 W WH RD or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Switch piano flush button single pole two way 5 Amps with ISI marked complete all as specified and as directed.
Angle holder PVC/polycarbonate type all as specified and as directed.
Switch Piano, flush type, 5 Amps, 240 Volts single pole with ISI marked complete all as specified and as directed.
Switch socket combination 3 & 2 pin, 5 Amps, 240 Volts, flush type multipurpose controlled by one switch all as specified and as directed.
Switch socket combination 2 in 1, 3 pin and 2 pin, 5 and 15 Amps flush type, universal complete all as specified and as directed
Socket outlet 2 in 1, 3 & 2 pin 5 Amps all as specified and as directed
Bell push flush type, one way 5 Amps all as specified and as directed.
MCB single pole and neutral 240 Volts, 40 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB single pole 240 Volts, 6 to 32 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB TPN 415 volts 32 to 63 Amps including taking down the existing complete as specified and as directed.
MCB DB SPN 4 way 240 volts, double door, with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
MCB DB SPN 8 way 240 volts, double door, with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
Stepped type electronic fan regulator flush socket type including taking down the existing complete as specified and as directed.
Ding dong bell AC 230 volts single pole including taking down the existing complete as specified and as directed.
Sub main wiring power/circuit using FRLS PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 6 sq.mm, earth continuity conductor of size 6 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade concealed in walls/roof/floors complete all as directed. NOTE:- Two wires of 6 sq.mm and one wire of 6 sq.mm and one run of PVC conduit shall be measured as one unit.
Sub main wiring power/circuit using FRLS PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 4 sq.mm, earth continuity conductor of size 4 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade concealed in walls/roof/floors complete all as directed. NOTE:- Two wires of 4 sq.mm and one wire of 4 sq.mm and one run of PVC conduit shall be measured as one unit.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing, heat resistant complete with driver, lamp bracket with impact and corrosion resistant, thermal management in multiple optics including taking out old fittings all asper Bajaj, Cat No.:- BREP 25 W LED WH C&S Cat No. LTESS36WlED/LS or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Brackets made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc., applying two coats of aluminum paint over a coat of red oxide primer before fixing including removing the old existing GI bracket from building complete all as specified and as directed.
DESTINY BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .